首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 443 毫秒
1.
A new method for the determination of the hydroxymetabolites of vitamin D(3) (24,25-(OH)(2)-D(3), 1,25-(OH)(2)-D(3) and 25-OH-D(3)) in plasma is reported. The method is based on the integration of three subsystems: continuous cleanup/preconcentration, HPL separation and post-column fluorimetric derivatisation. The derivatising subsystem is based on the dehydration reaction undergone by the secosteriod molecules in a strong-acid medium. The calibration graphs were run between 0.1 pg ml(-1) and 100 ng ml(-1) for each analyte with excellent regression coefficients (>/=0.9933) in all cases. The precision at two concentration levels was established with acceptable RSDs (%) in all instances (values between 2.1 and 5.2%). The method was also checked by applying it to human plasma samples spiked with the target analytes and the recoveries ranged between 86 and 106%.  相似文献   

2.
A liquid chromatography/electrospray ionization–tandem mass spectrometry‐based method was developed for the identification of the conjugation positions of the monoglucuronides of 25‐hydroxyvitamin D3 [25(OH)D3] and 24,25‐dihydroxyvitamin D3 [24,25(OH)2D3] in human urine. The method employed derivatization with 4‐(4‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione to convert the glucuronides into fragmentable derivatives, which provided useful product ions for identifying the conjugation positions during the MS/MS. The derivatization also enhanced the assay sensitivity and specificity for urine sample analysis. The positional isomeric monoglucuronides, 25(OH)D3‐3‐ and ‐25‐glucuronides, or 24,25(OH)2D3‐3‐, ‐24‐ and ‐25‐glucuronides, were completely separated from each other under the optimized LC conditions. Using this method, the conjugation positions were successfully determined to be the C3 and C24 positions for the glucuronidated 25(OH)D3 and 24,25(OH)2D3, respectively. The 3‐glucuronide was not present for 24,25(OH)2D3, unlike 25(OH)D3, thus we found that selective glucuronidation occurs at the C24‐hydroxy group for 24,25(OH)2D3.  相似文献   

3.
Vitamin D is an important determinant of bone health at all ages. The plasma concentrations of 25-hydroxy vitamin D (25-OH D) and other metabolites are used as biomarkers for vitamin sufficiency and function. To allow for the simultaneous determination of five vitamin D metabolites, 25-OH D3, 25-OH D2, 24,25-(OH)2 D3, 1,25-(OH)2 D3, and 1,25-(OH)2 D2, in low volumes of human plasma, an assay using ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) was established. Plasma samples were spiked with isotope-labeled internal standards and pretreated using protein precipitation, solid-phase extraction (SPE) and a Diels–Alder derivatization step with 4-phenyl-1,2,4-triazoline-3,5-dione. The SPE recovery rates ranged from 55% to 85%, depending on the vitamin D metabolite; the total sample run time was <5 min. Mass spectrometry was conducted using positive ion electrospray ionization in the multiple reaction monitoring mode on a quadrupole–quadrupole-linear ion trap instrument after pre-column addition of methylamine to increase the ionization efficiency. The intra- and inter-day relative standard deviations were 1.6–4.1% and 3.7–6.8%, respectively. The limit of quantitation for these compounds was determined to be between 10 and 20 pg/mL. The 25-OH D results were compared with values obtained for reference materials (DEQAS). In addition, plasma samples were analyzed with two additional Diasorin antibody assays. All comparisons with conventional methods showed excellent correlations (r 2 = 0.9738) for DEQAS samples, demonstrating the high degree of comparability of the new UHPLC-MS/MS technique to existing methods.  相似文献   

4.
A semi-automatic procedure for the continuous clean-up and concentration of several fat-soluble vitamins prior to their separation by HPLC and UV detection is reported. The procedure is based on the use of a minicolumn packed with aminopropylsilica as sorbent located prior to the chromatographic detection system. The overall process was developed and applied to the main liposoluble vitamins (A, D2, D3, E, K1, K3) and several hydroxy metabolites of vitamin D3 [25-(OH)-D3,24,25-(OH)2-D3 and 1,25-(OH)2-D3]. All the analytes were monitored at a compromise wavelength of 270 nm. Calibration graphs were constructed between 0.01 and 100 ng ml-1 for vitamin D2 and D3 and their hydroxy metabolites, between 0.1 and 100 ng ml-1 for vitamin A, K1 and K3 and between 1 and 100 ng ml-1 for vitamin E, with excellent regression coefficients (> or = 0.9901) in all cases. The precision was established at two concentration levels with acceptable RSDs in all instances (between 3.6 and 8.7%). The method was appropriate for the determination of vitamin D2, D3, K1 and K3 and the 24,25-dihydroxy and 25-hydroxy metabolites of vitamin D3 in human plasma. The method was applied to plasma samples spiked with the target analytes and the recoveries ranged between 78 and 109%.  相似文献   

5.
建立了一种高通量液相色谱-串联质谱技术检测干血点(DBS)样本中25-羟基维生素D2[25(OH)D2]和25-羟基维生素D3[25(OH)D3]的方法.以DBS为样本,以4-苯基-1,2,4-三唑啉-3,5-二酮(PTAD)为试剂进行分析物衍生化,所需样本量仅约相当于6μL全血当量的DBS样本;使用甲醇直接超声提取分析物,避开了通常情况下DBS样本前处理中的全血复溶和蛋白质沉淀等繁琐步骤;整个前处理过程使用自动化液体处理平台实现自动化操作和高检测通量;以25(OH)D2-D6和25(OH)D3-D3为同位素内标,消除基质效应的影响.前处理后的样本进行LC-MS/MS分析,使用C18柱进行分离,流动相为甲醇(含5 mmol/L甲酸铵)-水(含5 mmol/L甲酸铵)(75:25,V/V),洗脱时间为4 min,使用多反应监测模式(MRM)定量.结果表明:25(OH)D2和25(OH)D3的检出限为0.12 ng/mL(S/N=3),定量限为0.94 ng/mL(S/N=10).25(OH)D2和25(OH)D3在0.94~120.00 ng/mL范围内线性关系良好,日内相对标准偏差(RSD)分别为1.4%~8.6%和3.7%~15.5%,日间RSD分别为4.0%~5.3%和3.8%~14.9%,平均回收率分别为91.7%±7.9%~108.5%±6.5%和94.8%±6.8%~101.3%±2.9%.DBS样本在不同温度(-20℃,22℃,37℃)下储存不同时间(0,1,2,3,5,7,14天)后的稳定性实验显示样本总体RSD°15%.以25(OH)D参考物质NIST SRM 972a中的Level 3制备标准DBS样本,25(OH)D2和25(OH)D3的回收率分别为110.3%和103.0%.  相似文献   

6.
A rapid and sensitive liquid chromatography–isotope dilution tandem mass spectrometry method was developed and validated for quantification of itraconazole (ITZ) and its active metabolite hydroxyitraconazole (OH‐ITZ ) in human plasma. The plasma samples were extracted with tert‐butyl methyl ether and two isotope‐labeled internal standards (D5‐itraconazole and D5‐hydroxyitraconazole) were used. The chromatographic separation was performed on a Capcell Pak C18 MG III (100 × 2 mm, 5 µm, Shiseido). The protonated ions of analytes were detected in positive ionization in multiple reaction monitoring mode. The plasma method has a lower limit of quantification of 1 ng/mL with a linearity range of 1–500 ng/mL for ITZ and OH‐ITZ using 100 µL of plasma. The recoveries of the method were found to be 69.47–71.98% for ITZ and 75.68–82.52% for OH‐ITZ. The intra‐ and inter‐batch precision was less than 11% for all quality control samples at concentrations of 2.5, 200 and 400 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity.The validated method was successfully applied to analysis of human plasma samples in pharmacokinetics study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
The direct determination of dialkyl phosphates (DAPs) in water by strong anion-exchange (SAX) liquid chromatography/atmospheric pressure chemical ionization (APCI) mass spectrometry was investigated. The SAX high-performance liquid chromatography (HPLC) column was eluted with methanol/water gradients containing ammonium formate (AF) separating the DAPs which included six dimethyl- and diethyl-substituted phosphates, thiophosphates, and dithiophosphates. The high buffer concentrations required for separation were compatible with -ve APCI, but in +ve APCI the DAPs were unstable giving anomalous ions such as [M+15]+ and [M+29]+. These ions are believed to result from ion molecule reactions with CH3OH2+ in the plasma. DAPs are very stable in -ve APCI being detected as abundant [M-H](-) ions, even with 200 mM AF. At higher AF concentration formate clusters ([M+45](-) and [M+91](-)) were seen. Fragmentation by collision-activated dissociation (CAD) was more efficient for deprotonated ethyl-substituted DAPs which lost ethylene followed by ethanol. APCI instrument detection limits were in the low ng/mL range and the response was highly linear. Isotope dilution quantitation using d10-diethyl dithiophosphate (DEDTP) as an internal standard produced an instrument detection limit of 2 ng DEDTP/mL and method detection limit (MDL) of 9.3 ng/mL with accuracy of 99% (spike concentration, 25 ng/mL). DAP mixtures required storage in cold, dry conditions and alcohol solvents should be avoided because of solvolysis reactions.  相似文献   

8.
A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method has been developed to determine 1, 2-[bis(1,2-benzisoselenazolone-3(2H)-ketone)]-ethane (BBSKE), a novel antineoplastic agent, in rat plasma. The analytes were separated on a C18 column with a mobile phase of methanol-water (75:25, v/v) and detected using a triple-quadrupole mass spectrometer in positive mode with the selective reaction monitoring. The characteristic ion dissociation transitions were m/z 603.0 --> 448.9 for derivatized BBSKE and m/z 631.0 --> 476.8 for derivatized internal standard. The assay was linear over a range of 1-1000 ng/mL with a lower limit of quantification of 1 ng/mL. Intra- and inter-day precisions were less than 9.6 and 5.0%, respectively, and the accuracy ranged from -5.2 to 4.0%. The validated method was successfully applied to the characterization of pharmacokinetic profile of BBSKE after oral administration in rats. Cop  相似文献   

9.
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of trantinterol enantiomers in rat plasma. Diphenhydramine was employed as the internal standard. The plasma samples were prepared using liquid-liquid extraction with n-hexane-dichloromethane-isopropanol (20:10:1, v/v/v) as the extractant. Trantinterol enantiomers after pre-column derivatization using diacetyl-l-tartaric anhydride (DATAAN) were separated on a C18 column using a gradient solvent programme. The mobile phase was composed of 3 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curve for each enantiomer was obtained in the concentration range of 1-80 ng/mL, with limit of quantification (LOQ) of 1 ng/mL. The intra- and inter- precision (R.S.D.) values were below 9.6% and accuracy (R.E.) was from −2.4 to 6.2% at all quality control (QC) levels. The developed method was applied to the enantioselective pharmacokinetic study of trantinterol in rats.  相似文献   

10.
The determination of the urinary vitamin D3 metabolites might prove helpful in the assessment of the vitamin D status. We developed a method for the determination of trace vitamin D3 metabolites, 25-hydroxyvitamin D3 [25(OH)D3] and 24,25-dihydroxyvitamin D3 [24,25(OH)2D3], in urine using liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) combined with derivatization using an ESI-enhancing reagent, 4-(4′-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD), and its isotope-coded analogue, 2H4-DAPTAD (d-DAPTAD). The urine samples were treated with β-glucuronidase, purified with an Oasis® hydrophilic–lipophilic balanced (HLB) cartridge, and then subjected to the derivatization. The DAPTAD derivatization enabled the highly sensitive detection (detection limit, 0.25 fmol on the column), and the use of d-DAPTAD significantly improved the assay precision [the intra- (n?=?5) and inter-assay (n?=?3) relative standard deviations did not exceed 9.5 %]. The method was successfully applied to urine sample analyses and detected the increases of the urinary 25(OH)D3 and 24,25(OH)2D3 levels due to vitamin D3 administration. Graphical Abstract
Scheme of procedure for urinary vitamin D3 metabolite analysis based on LC/MS/MS with ESI-enhancing and isotope-coded derivatization.  相似文献   

11.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

12.
With the rapid shift to an aging society in Japan, age-related diseases, such as osteoporosis, dementia and cancer, are sharply increasing. The measurement of steroids related to these diseases in biological fluids and tissues is useful for elucidation of the nature, diagnosis and treatment of such diseases. LC/MS is considered to be the most promising method for this purpose due to its specificity and versatility, but it sometimes does not demonstrate the required sensitivity for trace amounts of steroids, because steroids have a rather low response using either electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI). To overcome this problem, the author developed detection-oriented derivatization procedures for steroids in LC/MS. For ESI-MS, introduction of a permanently charged moiety is effective. Based on this, 2-hydrazino-1-methylpyridine was developed and used in monitoring prostatic 5alpha-dihydrotestosterone, a good index for the follow-up of patients affected by prostate cancer under androgen deprivation therapy and salivary dehydroepiandrosterone, which is now often designated as an anti-aging hormone. A proton-affinitive Cookson-type reagent, 4-[2-(6,7-dimethoxy-4-methyl-3-oxo-3,4-dihydroquinoxalyl)ethyl]-1,2,4-triazoline-3,5-dione, was used for the determination of 1alpha-hydroxyvitamin D3 [1alpha(OH)D3], a synthetic prodrug of the active form of vitamin D3, in human plasma, and this new LC/positive-APCI-MS method enabled the pharmacokinetic study of 1alpha(OH)D3 in humans. Electron-capture APCI-MS based on derivatization with 2-nitro-4-trifluoromethylphenylhydrazine was used for the analysis of neurosteroids, which affect brain excitability through action at the neurotransmitter receptors. With this method, the stress-induced rapid biosynthesis of pregnane-type neurosteroids in rat brains was demonstrated.  相似文献   

13.
Five new 2D coordination polymers, [Co(nip)(CuL)(H(2)O)]·CH(3)OH (1), [Mn(ip)(NiL)]·0.63H(2)O (2), [Cu(ip)(CuL)] (3), [Mn(6)(CuL)(6)(btc)(4)(H(2)O)(4)]·7H(2)O (4), and [Cu(CuL)(Hbtc)(H(2)O)] (5)(ML, H(2)L = 2,3-dioxo-5,6,14,15-dibenzo-1,4,8,12-tetraazacyclo-pentadeca-7,13-diene; H(2)nip = 5-nitroisophthalic acid; H(2)ip = m-isophthalic acid; H(3)btc = 1,3,5-benzenetricarboxylic acid) have been synthesized by a solvothermal method and characterized by single-crystal X-ray diffraction. Complexes 1-5 exhibit different 2D layered structures formed by Co(2)Cu(2) (1), Mn(2)Ni(2) (2), Cu(4) (3), Mn(3)Ni(3) (4), Cu(4) (5) units, respectively, via the oxamide and diverse carboxylic acid bridges. Compounds 1, 2, 3 and 5 are uninodal 4-connected (4, 4)-grids topology, while complex 4 possesses a 2D network with (3, 4)-connected (4(2).8)(4)(4(3).6(2).8)(3) topology. The results of magnetic determination show pronounced antiferromagnetic interactions in 1-4.  相似文献   

14.
A reaction of trans-[Ir(4-C(5)NF(4))(η(2)-C(2)H(4))(PiPr(3))(2)] (1) with an excess of water in THF at room temperature affords the hydrido hydroxo complex trans-[Ir(4-C(5)NF(4))(H)(OH)(PiPr(3))(2)] (2). Treatment of 2 with CO furnishes trans-[Ir(4-C(5)NF(4))(H)(OH)(CO)(PiPr(3))(2)] (3). Reductive elimination of water from 3 leads to the formation of the iridium(I) carbonyl complex trans-[Ir(4-C(5)NF(4))(CO)(PiPr(3))(2)] (4). The insertion of CO(2) into the Ir-O bond of 2 forms the hydrido hydrogencarbonato complex trans-[Ir(4-C(5)NF(4))(H)(κ(2)-(O,O)-O(2)COH)(PiPr(3))(2)] (5). Treatment of 2 with NH(3) in C(6)D(6) yields trans-[Ir(4-C(5)NF(4))(H)(OH)(NH(3))(PiPr(3))(2)] (6). Storage of the reaction mixture at room temperature reveals the formation of the N-H activation product [Ir(4-C(5)NF(4))(H)(μ-NH(2))(NH(3))(PiPr(3))](2) (7).  相似文献   

15.
[8+12]-metallamacrocycle-based 3D frameworks {[Cu(4)(pbt)(2)(SO(4))(2)(DMF)(2)(CH(3)OH)]·7H(2)O·DMF}(n) (1) and [12]-macrocycle 3D {[Cu(2)(pbt)(SO(4))(DMSO)(CH(3)OH)(2)]·5H(2)O·CH(3)OH}(n) (2) have been obtained. Both complexes display antiferromagnetic couplings and high catalytic activity in the oxidative coupling reaction of 1-ethynylbenzene and oxazolidin-2-one.  相似文献   

16.
丘忠丽  林缨  熊志立  谢剑炜 《色谱》2014,32(7):779-783
建立了大鼠血浆中内源性胍丁胺的同位素稀释-气相色谱-负化学电离质谱定量分析方法。大鼠血浆样品经蛋白沉淀并蒸干后,用六氟乙酰丙酮衍生化,采用Florisil固相萃取柱净化,以稳定同位素标记的d8-胍丁胺为内标,在气相色谱-质谱仪上采用负化学电离方式电离,选择离子模式检测。胍丁胺标准溶液的检出限为0.0057 ng/mL。血浆中添加的胍丁胺在1.14~57.0 ng/mL范围内呈良好的线性关系(r=0.997),方法回收率介于92.3%~109.8%之间,日内和日间精密度均小于15%。大鼠血浆中胍丁胺平均含量水平为(22±9)ng/mL,雌、雄大鼠血浆中的胍丁胺水平未见显著性差异(p>0.05)。该方法特异性好、灵敏度高,为生物体内胍丁胺的生理功能研究提供了高灵敏的分析方法。  相似文献   

17.
Utilizing 3,5-bis(x-pyridyl)-1,2,4-triazole (x-Hpytz, x = 3; x = 4) as multidentate ligands, six novel coordination polymers with Zn(II) or Cd(II) metal ions were prepared: [Zn(3-pytz)(0.5)(OH)(0.5)Cl](n) (1, 1D ladder), {[Zn(3-Hpytz)(H(2)O)(4)] [Zn(3-Hpytz)(H(2)O)(3)·SO(4)]SO(4)·5H(2)O}(n) (2·5H(2)O, 1D chain), [Cd(3-Hpytz)(SO(4))](n) (3, 3D framework), {[Cd(3-Hyptz)SO(4)·3H(2)O]·2H(2)O}(n) (4·2H(2)O, 1D chain), [Zn(4-pytz)Cl](n) (5, 3D framework) and [Zn(2)(4-pytz)(SO(4))(OH)](n) (6, 3D framework). All compounds were obtained from hydrothermal reactions, with the exception of compound 4 which was obtained by solvent diffusion at room temperature. All compounds were characterized by FTIR, elemental analysis and TGA analysis and their structures were determined by X-ray diffraction. All compounds exhibited substantial thermal stability and showed photofluorescent properties that resulted from ligand π-π* transition.  相似文献   

18.
A highly sensitive and convenient gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of 5-fluorouracil in the presence of 2'-deoxy-5-fluorouridine (which breaks down into 5-fluorouracil during ordinary GC derivatization) in biological samples such as plasma and urine. After extraction with ethyl acetate, 5-fluorouracil and 5-chlorouracil, the latter being used as an internal standard, were converted into their tert.-butyldimethylsilyl derivatives by allowing the mixture to stand for 30 min at room temperature and were assayed by electron-impact ionization GC-MS. Under these conditions, 2'-deoxy-5-fluorouridine did not decompose or interfere with the determination of 5-fluorouracil. The assay method, including the extraction and tert.-butyldimethylsilyl derivatization of 5-fluorouracil, showed good linearity in the range 0-100 ng/ml for 5-fluorouracil in plasma (detection limit 0.5 ng/ml) and urine (detection limit 1 ng/ml). The usefulness of this method was demonstrated by determining plasma concentrations of 5-fluorouracil in rats treated intravenously with 5-fluorouracil and 2'-deoxy-5-fluorouridine.  相似文献   

19.
The lipoxygenase mimic [Fe(III)(PY5)(OH)](CF3SO3)2 is synthesized from the reaction of [Fe(II)(PY5)(MeCN)](CF3SO3)2 with iodosobenzene, with low-temperature studies suggesting the possible intermediacy of an Fe(IV) oxo species. The Fe(III)-OH complex is isolated and identified by a combination of solution and solid-state methods, including EPR and IR spectroscopy. [Fe(III)(PY5)(OH)](2+) reacts with weak X-H bonds in a manner consistent with hydrogen-atom abstraction. The composition of this complex allows meaningful comparisons to be made with previously reported Mn(III)-OH and Fe(III)-OMe lipoxygenase mimics. The bond dissociation energy (BDE) of the O-H bond formed upon reduction to [Fe(II)(PY5)(H2O)]2+ is estimated to be 80 kcal mol(-1), 2 kcal mol(-1) lower than that in the structurally analogous [Mn(II)(PY5)(H2O)]2+ complex, supporting the generally accepted idea that Mn(III) is the thermodynamically superior oxidant at parity of coordination sphere. The identity of the metal has a large influence on the entropy of activation for the reaction with 9,10-dihydroanthracene; [Mn(III)(PY5)(OH)]2+ has a 10 eu more negative DeltaS++ value than either [Fe(III)(PY5)(OH)]2+ or [Fe(III)(PY5)(OMe)]2+, presumably because of the increased structural reorganization that occurs upon reduction to [Mn(II)(PY5)(H2O)]2+. The greater enthalpic driving force for the reduction of Mn(III) correlates with [Mn(III)(PY5)(OH)]2+ reacting more quickly than [Fe(III)(PY5)(OH)]2+. Curiously, [Fe(III)(PY5)(OMe)]2+ reacts with substrates only about twice as fast as [Fe(III)(PY5)(OH)]2+, despite a 4 kcal mol(-1) greater enthalpic driving force for the methoxide complex.  相似文献   

20.
The syntheses, crystal structures, and magnetochemical characterization are reported for three new mixed-valent Mn clusters [Mn(8)O(3)(OH)(OMe)(O(2)CPh)7(edte)(edteH(2))](2)CPh) (1), [Mn(12)O(4)(OH)(2)(edte)(4)C(l6)(H(2)O)(2)] (2), and [Mn(20)O(8)(OH)(4)(O(2)CMe)(6)(edte)(6)](ClO(4))(2) (3) (edteH(4) = (HOCH(2)CH(2))(2)NCH(2)CH(2)N(CH(2)CH(2)OH)(2) = N,N,N',N'-tetrakis(2-hydroxyethyl)ethylenediamine). The reaction of edteH(4) with Mn(O(2)CPh)(2), MnCl(2), or Mn(O(2)CMe)(2) gives 1, 2, and 3, respectively, which all possess unprecedented core topologies. The core of 1 comprises two edge-sharing [Mn(4)O(4)] cubanes connected to an additional Mn ion by a micro(3)-OH- ion and two alkoxide arms of edteH(22-). The core of 2 consists of a [Mn(12)(micro(4-)O)(4)](24+) unit with S4 symmetry. The core of 3 consists of six fused [Mn(4)O(4)] cubanes in a 3 x 2 arrangement and linked to three additional Mn atoms at both ends. Variable-temperature, solid-state dc and ac magnetization (M) studies were carried out on complexes 1-3 in the 5.0-300 K range. Fitting of the obtained M/Nmicro(B) vs H/T data by matrix diagonalization and including only axial zero-field splitting (ZFS) gave ground-state spin (S) and axial ZFS parameter (D) of S = 8, D = -0.30 cm-1 for 1, S = 7, D = -0.16 cm-1 for 2, and S = 8, D = -0.16 cm-1 for 3. The combined work demonstrates that four hydroxyethyl arms on an ethylenediamine backbone can generate novel Mn structural types not accessible with other alcohol-based ligands.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏