首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p′-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p′-DDT and its chiral degradation product, o,p′-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC × GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p′-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p′-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC–TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p′-isomers from the complex sample chromatogram, 1D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p′-DDT and o,p′-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by 1D GC–TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC × GC–TOFMS using the same enantioselective column, this time as the first dimension of separation.  相似文献   

2.
So far the majority of the measurements of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) were obtained from on-line high performance liquid chromatography–gas chromatography–flame ionization detection (on-line HPLC–GC–FID). Since this technique is not available in many laboratories, an alternative method with more easily available tools has been developed. Preseparation on a small conventional liquid chromatographic column was optimized to achieve robust separation between the MOSH and the MOAH, but also to keep out the wax esters from the MOAH fraction. This was achieved by mixing a small portion of silica gel with silver nitrate into highly activated silica gel and by adding toluene into the eluent for the MOAH. Toluene was also added to the MOSH fraction to facilitate reconcentration and to serve as a keeper preventing loss of volatiles during solvent evaporation. A 50 μl volume was injected on-column into GC–FID to achieve a detection limit for MOSH and MOAH below 1 mg/kg in most foods.  相似文献   

3.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

4.
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC–TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ2tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC × GC–TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, 2Wb, also impacts trilinearity, along with Δ2tR. The term trilinearity deviation ratio, TDR, which is Δ2tR normalized by 2Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC × GC–TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1–2 s range provides an optimized peak capacity for the first dimension separation (500–600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12–15), concurrent with an optimized two-dimensional peak capacity (6000–7500), combined with sufficiently low TDR values (0–0.05) to facilitate low quantitative errors with PARAFAC (0–0.5%). In contrast, use of a PM in the 5 s or greater range provides a higher peak capacity on the second dimension (30–35), concurrent with a lower peak capacity on the first dimension (100–150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000–4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence.  相似文献   

5.
In this work, a methodology to characterise the volatile and semi-volatile compounds from marine salt by headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC/TOFMS) was developed. Samples from two saltpans of Aveiro, in Portugal, with diverse locations, obtained over three years (2004, 2005, and 2007) were analysed. A 50/30 μm divinylbenzene/carboxen/polydimethylsiloxane SPME fibre was used. The volatiles present in the headspace of the solid salt samples (crystals) were equilibrated overnight at 60 °C and extracted for 60 min prior to injection in the GC × GC/TOFMS. 157 compounds, distributed over the chemical groups of hydrocarbons, aldehydes, esters, furans, haloalkanes, ketones, ethers, alcohols, terpenoids, C13 norisoprenoids, and lactones were detected across the samples. Furans, haloalkanes and ethers were identified for the first time in marine salt. The large number of co-elutions on the first column that were resolved by the GC × GC system revealed the complexity of marine salt volatile composition. The existence of a structured 2D chromatographic behaviour according to volatility, in the first dimension (1D), and primarily polarity, in the second dimension (2D), was demonstrated, allowing more reliable identifications. The resolution and sensitivity of GC × GC/TOFMS enabled the separation and identification of a higher number of volatile compounds compared to GC–qMS, allowing a deeper characterisation of this natural product.  相似文献   

6.
Comprehensive two-dimensional gas chromatography (GC × GC) offers an interesting tool for profiling bacterial fatty acids. Flow modulated GC × GC using a commercially available system was evaluated, different parameters such as column flows and modulation time were optimized. The method was tested on bacterial fatty acid methyl esters (BAMEs) from Stenotrophomonas maltophilia LMG 958T by using parallel flame ionization detector (FID)/mass spectrometry (MS). The results are compared to data obtained using a thermal modulated GC × GC system. The data show that flow modulated GC × GC-FID/MS method can be applied in a routine environment and offers interesting perspectives for chemotaxonomy of bacteria.  相似文献   

7.
Ha J  Seo D  Shin D 《Talanta》2011,85(1):252-258
Trans fatty acids (TFAs) are present in meat and dairy products as m ruminant animals and in vegetable fats due to partial hydrogenation. This study aimed to discriminate between natural (N-TFA) and hydrogenated trans fatty (H-TFA) acids by GC × GC-flame ionization detection (GC × GC-FID) and comprehensive GC × GC-time-of-flight mass spectrometry (GC × GC-TOFMS). The separation of two kinds of trans fats, vaccenic acid (18:1 trans-11) and elaidic acid (18:1 trans-9), was performed using GC × GC-FID and GC × GC-TOFMS. A 100 m × 0.25 mm I.D. × 0.2 μm (film thickness) SP-2560 (bis-cyanopropyl polysiloxane) fused capillary column (first separation dimension, 1D) was coupled to a 1.5 m × 0.18 mm I.D. × 0.18 μm (film thickness) RTX-5 (5% diphenyl/95% dimethyl polysiloxane) fused capillary column (second separation dimension, 2D). The RSD of the intra-day repeatability by both GC × GC-FID and GC × GC-TOFMS for elaidic and vaccenic acids was ≤9.56% and ≤9.97%, and the RSD of the inter-day repeatability was ≤8.49 and ≤9.06%, respectively. It was found that the V/E value (vaccenic acid to elaidic acid ratio) could be used to distinguish H-TFA from N-TFA and to evaluate the quality of the fatty foods.  相似文献   

8.
The objective of the present research is directed towards the optimized use of a 50 μm ID secondary column, in a comprehensive two-dimensional gas chromatography–quadrupole mass spectrometry (GC × GC–qMS) system. The analytical aim was achieved by exploiting a split-flow GC × GC approach, and a rapid-scanning qMS instrument. The stationary phase combination consisted of an apolar (silphenylene polymer) 30 m × 0.25 mm ID column, linked by means of a Y-union, to an MS-connected 1 m × 0.05 mm ID polar one [poly(ethyleneglycol)], and to a 0.20 m × 0.05 mm ID uncoated capillary segment; the latter was connected to a manually operated split-valve. It will be herein demonstrated that the split-flow GC × GC approach, successfully employed in previous H2-based, flame ionization detection experiments, provides equally satisfactory results using mass spectrometric detection and helium as carrier gas. An optimized split-flow GC × GC–qMS method was developed and exploited for the analysis of a perfume sample. The results attained were compared with those observed using the same analytical column combination, but with no flow-splitting. It was found that it is not convenient to employ a 50 μm ID secondary column in a conventional GC × GC–MS instrument. On the contrary, the use a 50 μm ID secondary column, in a split-flow, twin-oven system, provided a good performance. A recently developed comprehensive chromatography software was used for data processing.  相似文献   

9.
A novel selectable one-dimensional (1D) or two-dimensional (2D) gas chromatography–mass spectrometry (selectable 1D/2D GC–MS) system with selective detection was developed by using capillary flow technology and low thermal mass GC (LTM-GC). The main advantages of this system are the simple and fast selection of 1D GC–MS or 2D GC–MS operation without any instrumental set-up change (e.g.2D GC–MS can be run just after 1D GC–MS run), and simultaneous mass spectrometric and olfactometry or element-specific detection for both 1D and 2D separation to assure selection of a heart-cut region and correct identification of compounds of interest. The feasibility and benefit of the proposed system with selective detection, e.g. olfactometry, nitrogen phosphorus detection (NPD), and pulsed flame photometric detection (PFPD), was demonstrated with an identification of trace amounts of aroma components in beverages (beer and coffee). Using stir bar sorptive extraction (SBSE) and selectable 1D/2D GC–Olfactometry/MS on a beer sample, β-damascenone could be determined at 1.9 ng mL−1 (RSD 3.1%, n = 6) as a potent aroma compound. In a coffee sample, two odor active compounds were clearly resolved from a 4.2 s heart-cut and were assigned probable identifications as 4,5-dimethyl thiazole and dimethyl trisulfide based on a NIST library search, dual linear retention indices (dual LRI) and elemental information obtained by SBSE in combination with selectable 1D/2D GC–NPD/PFPD/MS.  相似文献   

10.
Two novel methodologies for quantification of C13 norisoprenoids in wines were developed. The first methodology, method A (reference method) was based on the headspace solid-phase microextraction combined with gas chromatography–quadrupole mass spectrometry operating in selected ion monitoring mode (HS-SPME–GC–qMS–SIM). This methodology allowed to select the GC conditions for an adequate chromatographic resolution of wine components. The second methodology, method B (rapid method) was based on the HS-SPME–GC–qMS–SIM, using GC conditions that allowed to obtain a C13 norisoprenoid volatile signature. In the later, the GC capillary column of 30 m at 220 °C was used acting as a transfer line of the components sorbed by the SPME coating fibre to the mass spectrometer, which acts as a sensor for m/z fragments 142 and 192. It does not require any pre-treatment of the sample, and the C13 norisoprenoid composition of the wine was evaluated based on the chromatographic profile and specific m/z fragments, without complete chromatographic separation of its components. For quantification purposes, external calibration curves were constructed with β-ionone chemical standard. Calibration curves with regression coefficient (r2) of 0.9940 and 0.9968, RSD of 1.08% and 12.51%, and detection limits of 1.10 and 1.57 μg L−1 were obtained for methods A and B, respectively. These methodologies were applied to seventeen white and red table wines. Two vitispirane isomers (158–1529 μg L−1) and 1,1,6-trimethyl-1,2-dihydronaphthalene (TDN) (6.42–39.45 μg L−1) were quantified. The data obtained for vitispirane isomers and TDN using the two methods were highly correlated (r2 of 0.9756 and 0.9630, respectively). Associated to the fast and robust character of the proposed rapid method B and considering the extraction time, it is important to focus its selectivity and potential applicability if specific m/z fragments would be established for new analytes.  相似文献   

11.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration.  相似文献   

12.
The application of comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) for the analysis of six anabolic agents (AAs) in doping control is investigated in this work. A non-polar–polar column configuration with 0.2 μm film thickness (df) second dimension (2D) column was employed, offering much better spread of the components on 2D when compared to the alternative 0.1 μm df2D column. The proposed method was tested on the “key” AA that the World Anti-Doping Agency (WADA) had listed at the low ng mL−1 levels (clenbuterol, 19-norandrosterone, epimethendiol, 17α-methyl-5α-androstane-3α,17β-diol, 17α-methyl-5β-androstane-3α,17β-diol and 3′-OH-stanozolol). The compounds were spiked in a blank urine extract obtained by solid-phase extraction, hydrolysis and liquid–liquid extraction; prior to analysis they were converted to the corresponding trimethylsilyl (TMS) derivatives. The limit of detection (LOD) was below or equal to the minimum required performance limit (MRPL) of 2 ng mL−1 defined by WADA, and the correlation coefficient was in the range from 0.995 to 0.999. The method allows choosing an ion from the full mass spectra which shows the least interference from the matrix and/or the best sensitivity; this can only be done if full scan mass spectral data are available. The advantage of GC × GC over classical one-dimensional GC (1D GC), in terms of separation efficiency and sensitivity, is demonstrated on a positive urine control sample at a concentration of 5 ng mL−1. The obtained similarity to the in-house created TOFMS spectra library at this level of concentration was in the range from 822 to 932 (on the scale from 0 to 999). Since full mass spectral information are recorded, the method allows the retro-search of non-target compounds or new “designer steroids”, which cannot be detected with established GC–MS methods that use selected ion monitoring (SIM) mode.  相似文献   

13.
The identification and quantification of complex mixtures of cis and trans octadecenoic (18:1) fatty acid isomers presents a major challenge for conventional one-dimensional GC/FID analysis of their methyl esters. We have compared the use of two methods to achieve optimized separations of positional and geometrical octadecenoic fatty acid isomers—comprehensive two-dimensional gas chromatography (GC × GC), and silver ion high performance liquid chromatography interfaced to atmospheric pressure photoionization (APPI) mass spectrometry. Nine isomers of octadecenoic acid methyl ester were well separated on a single silver ion column with a mobile phase of 0.018% acetonitrile and 0.18% isopropanol in hexane. Reproducible retention times were obtained with relative standard deviations of around 1% over 5 injections. The extra selectivity and reproducibility afforded by APPI-MS, together with the wide separation of cis and trans isomers by silver ion chromatography, resulted in a promising method for measurement of octadecenoic acid FAME. The GC × GC separation was performed using various column combinations, and optimal separation was obtained by coupling an ionic liquid column (Supelco SLB-IL100 [1,9-di(3-vinyl-imidazolium) nonane bis(trifluoromethyl) sulfonyl imidate]) in the first dimension with a SGE BPX50 (50% phenyl polysilphenylene-siloxane) in the second dimension. These methods have been applied to the analysis of octadecenoic acid in milk and beef fat.  相似文献   

14.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

15.
The present research is based on the full exploitation of the separation power of a 0.05 mm internal diameter (ID) capillary, as a comprehensive two-dimensional (2D) GC (GC × GC) secondary column, with the objective of attaining very high-resolution second dimension separations. The aim was achieved by using a split-flow system developed in previous research [P.Q. Tranchida, A. Casilli, P. Dugo, G. Dugo, L. Mondello, Anal. Chem. 79 (2007) 2266], and a dual-oven GC × GC instrument. The column combination employed consisted of a polar 30 m × 0.25 mm ID column connected, by means of a T union, to a detector-linked high-resolution 1.1 m × 0.05 mm ID apolar analytical column and to a 0.33 m × 0.05 mm ID retention gap; the latter was connected to a manually operated split valve. As previously demonstrated, the use of a split valve enables the regulation of gas flows through both analytical columns, generating the most appropriate gas linear velocities. Comprehensive 2D GC experiments were carried out on Arabica roasted coffee volatiles (previously extracted by means of solid-phase microextraction) with the split-valve closed (equal to what can be defined as conventional GC × GC) and with the split-valve opened at various degrees. The reasons why it is absolutely not effective to use a 0.05 mm ID column as second dimension in a conventional GC × GC instrument will be discussed and demonstrated. On the contrary, the use of a 0.05 mm ID column as second dimension, under ideal conditions in a split-flow, twin-oven system, will also be illustrated and discussed.  相似文献   

16.
The work compares two GC–MS methods for enantioselective separation of amino acids as suitable candidate for stereochemical analysis of chiral amino acids on board spacecrafts in space exploration missions of solar system body environments. Different derivatization reagents are used: a mixture of alkyl chloroformate–alcohol–pyridine to obtain the alkyl alkoxy carbonyl esters and a mixture of perfluorinated alcohols and anhydrides to form perfluoroacyl perfluoroalkyl esters. 20 proteinogenic amino acids were derivatized with the two procedures and submitted to GC–MS analysis on a Chirasil-l-Val stationary phase. The results were then compared in terms of the enantiomeric separation achieved and intensity of MS response. The combination of methyl chloroformate (MCF) and heptafluoro-1-butanol (HFB) allows separation of 14 enantiomeric pairs, five of which display a resolution (Rs ≥ 1.2) supposed to be sufficient to quantify the enantiomeric excess. Three mixtures of trifluoroacetic (TFAA) and heptafluorobutyric (HFBA) anhydrides were combined with the corresponding perfluorinated alcohols – TFE (2,2,2-trifluoro-1-ethanol) and HFB (2,2,3,3,4,4,4-heptafluoro-1-butanol) – to give three different reagents (TFAA–TFE, TFAA–HFB, HFBA–HFB): the derivatives obtained show separation of the same number of proteinogenic amino acids (14 of 20) at a temperature lower than column bleeding limit (200 °C) and 8 of them give a separation with Rs ≥ 1.2. Linearity study and limit of detection (XLOD) computation show that both methods are suitable for quantitative determination of several amino acid diastereomers at trace level (XLOD ≈ 0.5 nmol as derivatized quantity). Both the procedures were coupled with automatic data handling to increase their suitability for space analysis: the simplified data treatment is especially helpful to handle the low quality data recovered from space experiments and labor and time are saved, as imposed by the space experiments requiring a rapid delivery of the results. To achieve this aim, a chemometric approach based on the computation of the Autocovariance Function (ACVF) was applied to extract information on the enantiomeric pairs present in the sample and the enantioseparation achieved on the chiral column.  相似文献   

17.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

18.
An efficient analytical method for simultaneous determination of 12 SFEs in serum is described. The method involves solid-phase extraction to isolate of SFEs from interfering species, especially cholesteryl esters, conversion to trimethylsilyl (TMS) ether derivatives for the direct analysis by gas chromatography–mass spectrometry (GC–MS) using a high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. All SFEs as their TMS derivatives were well separated with excellent peak shapes within 12 min. Overall recoveries ranged from 88% to 119%, with a detection limits for SFEs ranged from 2 to 30 μg L−1. The linearity as correlation coefficient was higher than 0.99 except for pregnenolone-3-arachidate (r2 = 0.98) in the concentration range of 5–3000 μg L−1. Ten serum samples obtained from volunteers were also analyzed and quantitatively determined of DHEA-3-palmitate and pregnenolone-3-stearate in 1.8–1195.8 μg L−1 concentration. The devised high temperature GC–MS method could be useful for identification of SFEs in biological specimens including serum.  相似文献   

19.
A solid-phase extraction (SPE) using multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with gas chromatography–mass spectrometry (GC–MS) method was developed for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Several condition parameters, such as extraction adsorbents, elution solvents and volumes, and sample loading flow rate and volume were optimized to obtain high SPE recoveries and extraction efficiency. 150 mg MWCNTs as sorbent presented high extraction efficiency of 16 PAHs due to the large specific surface area and high adsorption capacity of MWCNTs compared with the commercial C18 column (250 mg/2 mL). The calibration curves of 16 PAHs extracted were linear in the range of 20–5000 ng L−1, with the correlation coefficients (r2) between 0.9848 and 0.9991. The method attained good precisions (relative standard deviation, RSD) from 1.2% to 12.1% for standard PAHs aqueous solutions; method recoveries ranged in 76.0–125.5%, 74.5–127.0%, and 70.0–122.0% for real spiked samples from river water, tap water and seawater, respectively. Limits of detection (LODs, S/N = 3) of the method were determined from 2.0 to 8.5 ng L−1. The optimized method was successfully applied to the determination of 16 PAHs in real environmental water samples.  相似文献   

20.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号