首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
In this work, a procedure for preconcentration of cobalt using dispersive liquid–liquid microextraction (DLLME) with the reagent Br-TAO as complexing reagent was developed. The procedure is based on a ternary system of solvents, where appropriate amounts of the extraction solvent, disperser solvent and the chelating agent Br-TAO are directly injected into an aqueous solution containing Co(II). A cloudy mixture is formed and the ions are extracted in the fine droplets of the extraction solvent. After extraction, the phase separation is performed with a rapid centrifugation, and cobalt is determined in the enriched phase by FAAS. Under the optimized conditions, the detection limit obtained was 0.9 µg L− 1. The enrichment factor and the consumptive index were 16 and 0.31 mL, respectively. The accuracy of the method was tested by the determination of cobalt in certified reference material of spinach leaves, NIST 1570a. The proposed procedure was successfully applied to the determination of cobalt in water samples.  相似文献   

2.
The supramolecular solvent system consists of tetrahydrofuran (THF) and 1-decanol, that was used as an extraction solvent for a microextraction procedure for the preconcentration and separation of Co(II). The proposed supramolecular-based procedure was combined with microsampling flame atomic absorption spectrometry for the determination of cobalt at trace levels in water samples. N-Benzoyl-N,N-diisobutylthiourea was used to chelate Co(II) in an aqueous solution. Quantitative extraction efficiency was obtained at pH 6.5. The effects of analytical parameters including pH, amount of ligand, type, ratio and volume of supramolecular solvent, sample volume and interfering ions were investigated for optimisation of the procedure. The proposed supramolecular solvent-based microextraction procedure (Ss-ME) exhibits a limit of detection (LOD) of 1.29 µg L?1 and a limit of quantification (LOQ) of 3.88 µg L?1. The procedure was validated by addition/recovery tests and by applying TMDA 64.2 and TMDA 53.3 water certified reference materials. The microextraction method was successfully applied for the preconcentration and determination of cobalt in water samples.  相似文献   

3.
We report on a new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni (II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on the injection of a ternary solvent system composed of appropriate quantities of extraction solvent (trichloroethylene), dispersive solvent (ethanol), and the chelating reagent 2-(2′-benzothiazolylazo)-p-cresol into the sample solution. The solution turns turbid immediately after injection, and the analytes are extracted into the droplets of the organic phase which was dried and dissolved in a mixture of Triton X-114, nitric acid, and ethanol. The metal ions in this mixture were quantified by ICP-OES. The detection limits under optimized conditions are 0.2, 0.3, 0.2 and 0.7?μg?L?1 for Cd(II), Co(II), Pb(II) and Ni(II), respectively. The enrichment factors were also calculated for Cd (13), Co (11), Pb (11) and Ni (8). The procedure was applied to the determination of cadmium, cobalt, lead and nickel in certified reference material (waterway sediment) and water samples.
Figure
A new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni(II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP OES) is presented. The procedure was applied to the determination of elements in samples of river and lake water.  相似文献   

4.
A simple and reliable method has been developed using chelating polymeric adsorbent (PSAHSB) to preconcentration of trace amount of Ni(II) ions from aqueous solutions under static loading conditions, and their determination by Ultraviolet and visible (UV–Vis) absorption spectroscopy. The influences of some analytical adsorption parameters, such as pH, temperature and contact time, the ionization constants of chelating groups in the adsorbent and desorption process were investigated. Maximum adsorption ≥98% was achieved at pH 3–7 after 20 min of contact time and the relative standard-deviation values were ≤5%. Adsorbed metal ions have been desorbed with 10 mL of 2 M HCl acid with the detection limit of 0.0157 μg m−1. The Langmuir and Freundlich isotherm equations were used to describe adsorption behavior of the system at different temperatures. Kinetic and thermodynamic behavior of the adsorbent for Ni(II) ion preconcentration was also studied. The possible adsorption mechanism of Ni (II) ions onto modified adsorbent is also discussed. This method was applied efficiently to remove Ni (II) ions from environmental water samples.  相似文献   

5.
A new method using a column packed with graphene as adsorbent was developed for the preconcentration of trace amounts of cobalt (Co) and nickel (Ni) prior to their determinations by flame atomic absorption spectrometry. Several factors influencing the extraction efficiency of Co and Ni and their subsequent determinations, such as pH, amounts of the chelating agent, flow rates of sample and eluent solution, eluent type and its volume, breakthrough volume, and adsorption capacity were established. Under the optimum conditions, the calibration graphs were linear in the range of 4.0‐200.0 μg L?1 and 5.0‐200.0 μg L?1 with detection limits of 0.36 μg L?1 and 0.51 μg L?1 for Co and Ni, respectively. Good relative standard deviations for ten determinations of 100.0 μg L?1 of Co and Ni were 3.2 and 3.6%, respectively. The results for determination of Co and Ni in tap water, river water, sea water, vegetable and spiked samples have demonstrated the accuracy and applicability of the proposed method. To validate the proposed method, three certified reference materials of environment water (GSBZ 50030‐94 and GSB 07‐1186‐2000) and tomato leaf (GSBZ 51001‐94) were analyzed, and the determined values were in good agreement with the certified values.  相似文献   

6.
《Microchemical Journal》2009,91(2):107-112
A simple and powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 mL of its aqueous sample in the pH = 6 as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) cationic complex into a 4 µL drop of nitrobenzene and ammonium tetraphenylborate as counter ion. In the drop, the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [Pd(c) + Pd(i)]. Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 390 and 78%, respectively. The calibration graph was linear in the range of 0.01–1 µg L 1 with correlation coefficient of 0.9952 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0065 µg L 1 and relative standard deviation (RSD) for eight replicate measurements of 0.1 µg L 1 and 0.4 µg L 1 cadmium was 6.4 and 5.8% respectively. The characteristic concentration was 0.0014 µg L 1 equivalent to a characteristic mass of 5.6 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.  相似文献   

7.
A new chelating sorbent has been developed using Amberlite XAD-2 resin anchored with pyrocatechol through –N=C– group. This sorbent, characterised by elemental analysis and infrared (IR) spectra, was used as packing for the minicolumn in an on-line system preconcentration system for cadmium, cobalt, copper and nickel determination. Metal ions were sorbed in the minicolumn, from which it could be eluted directly to the nebulizer–burner system of the flame atomic absorption spectrometer (FAAS). Elution of all metals from minicolumn can be made with 0.50 mol L 1 HCl or HNO3. The enrichment factors obtained were 16 (Cd), 24 (Co), 15 (Cu) and 19 (Ni), for 60 s preconcentration time, and 39 (Cd), 69 (Co), 36 (Cu) and 41 (Ni), if used 180 s preconcentration time. Under the optimum conditions, the proposed procedure allowed the determination of cadmium, cobalt, copper and nickel with detection limits of 0.31, 0.32, 0.39 and 1.64 μg L 1, respectively, when used preconcentration periods of 180 s. The accuracy of the developed procedure was sufficient and evaluated by the analysis of the certified reference materials NIST 1515 apple leaves and NIST 1570a spinach leaves. The method was applied to the analysis of food samples (spinach, black tea and rice flour).  相似文献   

8.
First, the extraction and preconcentration of ultratrace amounts of lead(II) ions was performed using microliter volumes of a task‐specific ionic liquid. The remarkable properties of ionic liquids were added to the advantages of microextraction procedure. The ionic liquid used was trioctylmethylammonium thiosalicylate, which formed a lead thiolate complex due to the chelating effect of the ortho‐positioned carboxylate relative to thiol functionality. So, trioctylmethylammonium thiosalicylate played the roles of both chelating agent and extraction solvent simultaneously. Hence, there is no need to use a ligand. The main parameters affecting the efficiency of the method were investigated and optimized. Under optimized conditions, this approach showed a linear range of 2.0–24.0 ng/mL with a detection limit of 0.0010 ng/mL. The proposed method was applied to the extraction and preconcentration of lead from red lipstick and pine leaves samples prior to electrothermal atomic absorption spectroscopic determination.  相似文献   

9.
A simple, sensitive and powerful on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system was developed as an alternative approach for on-line metal preconcentration and separation, using extraction solvent at microlitre volume. The potentials of this novel schema, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace copper and lead determination in water samples. The stream of methanol (disperser solvent) containing 2.0% (v/v) xylene (extraction solvent) and 0.3% (m/v) ammonium diethyldithiophosphate (chelating agent) was merged on-line with the stream of sample (aqueous phase), resulting a cloudy mixture, which was consisted of fine droplets of the extraction solvent dispersed entirely into the aqueous phase. By this continuous process, metal chelating complexes were formed and extracted into the fine droplets of the extraction solvent. The hydrophobic droplets of organic phase were retained into a microcolumn packed with PTFE-turnings. A portion of 300 μL isobutylmethylketone was used for quantitative elution of the analytes, which transported directly to the nebulizer of FAAS. All the critical parameters of the system such as type of extraction solvent, flow-rate of disperser and sample, extraction time as well as the chemical parameters were studied. Under the optimum conditions the enhancement factor for copper and lead was 560 and 265, respectively. For copper, the detection limit and the precision (R.S.D.) were 0.04 μg L−1 and 2.1% at 2.0 μg L−1 Cu(II), respectively, while for lead were 0.54 μg L−1 and 1.9% at 30.0 μg L−1 Pb(II), respectively. The developed method was evaluated by analyzing certified reference material and applied successfully to the analysis of environmental water samples.  相似文献   

10.
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L?1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.  相似文献   

11.
In this study, a simple and efficient method of ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) has been developed for simultaneous extraction, preconcentration and determination of manganese, cadmium, cobalt and nickel in water samples. In the proposed approach, tetrachloroethylene was selected as extraction solvent. The effect of important experimental factors such as volume of extraction solvent, pH, sonication time, salt concentration, and temperature was investigated by using a fractional factorial design (25?1) to identify important factors and their interactions. In the next step, a Box-Behnken design (BBD) was applied for optimisation of significant factors. The obtained optimal conditions were: 30?µL for extraction solvent, 12 for pH, 5?min for sonication time, and 5% w/v for salt concentration. The limits of detections (LODs) for Cd(II), Co(II), Mn(II) and Ni(II) were 0.20, 0.13, 0.21 and 0.28?µg?L?1, respectively. Relative standard deviations (RSD, C?=?200.0?µg?L?1, n?=?9) were between 3.4–7.5% and the calibration graphs were linear in the range of 0.25 to 1000.0?µg?L?1 for Mn, 0.5–1000.0?µg?L?1 for Co and Ni and 1.0–250.0?µg?L?1 for Cd. The determination coefficients (R 2) of the calibration curves for the analytes were in the range of 0.993 to 0.999. The proposed method was validated by using two certified reference materials, and also the method was applied successfully for the determination of heavy metals in different real water samples.  相似文献   

12.
A method was developed for the determination of silver ion (Ag) by combining dispersive liquid-liquid microextraction preconcentration with graphite furnace atomic absorption spectrometry. Diethyldithiocarbamate was used as a chelating agent, and carbon tetrachloride and methanol as extraction and dispersive solvent. Factors influencing the extraction efficiency of Ag and its subsequent determination were studied and optimized. The detection limit is 12 ng L?1 (3 s) with an enrichment factor of 132, and the relative standard deviation is 3.5% (n?=?7, at 1.0 ng mL?1). The method was successfully applied to the determination of trace amounts of Ag in water samples.  相似文献   

13.
A green, simple, rapid and efficient solventless temperature-assisted homogeneous liquid-liquid microextraction based on 8-hydroxyquinoline as complexing agent and extractant, followed by flame atomic absorption spectrometry was developed for the extraction, enrichment, and determination of trace amounts of nickel and cobalt in aqueous samples. For this purpose, first, a specified amount of 8-hydroxyquinoline is added to the analytes solution. Then the temperature of the solution is increased to melt 8-hydroxyquinoline and form a homogeneous solution. Then, it is cooled to room temperature and a cloudy solution is formed due to decreasing 8-hydroxyquinoline solubility. The solution is then centrifuged, and 8-hydroxyquinoline particles containing the produced complexes (8-hydroxyquinoline-cation) are collected at the bottom of the tube. They are removed and dissolved in a suitable solvent and injected to the detection system. The main parameters affecting the extraction efficiency, such as the amount of 8-hydroxyquinoline, solvent nature, pH, extraction temperature and heating time were investigated. Under optimum conditions, linear ranges for Co(II) and Ni(II) were 1–100 and 0.5–75 µg L?1, respectively. Relative standard deviations for intra- and inter-day precisions calculated from six repeated determinations at three different concentrations of Co(II) and Ni(II) were ≤5.2 %. Moreover, the obtained detection limits of the analytes were 0.35 and 0.20 µg L?1 for Co(II) and Ni(II), respectively. The accuracy of the developed procedure was checked by analysing SPS-WW2 Batch 108 water as a certified reference material. Finally, the developed method was successfully applied for the determination of the selected cations in water and fruit juice samples.  相似文献   

14.
Sereshti H  Khojeh V  Samadi S 《Talanta》2011,83(3):885-890
In this study, dispersive liquid-liquid microextraction (DLLME) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed for simultaneous preconcentration and trace determination of chromium, copper, nickel and zinc in water samples. Sodium diethyldithiocarbamate (Na-DDTC), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters of DLLME such as volume of extraction and disperser solvents, pH, concentration of salt and concentration of the chelating agent were studied by a (2f−1) fractional factorial design to identify the most important parameters and their interactions. The results showed that concentration of salt and volume of disperser solvent had no effect on the extraction efficiency. In the next step, central composite design was used to obtain optimum levels of effective parameters. The optimal conditions were: volume of extraction solvent, 113 μL; concentration of the chelating agent, 540 mg L−1; and pH, 6.70. The linear dynamic range for Cu, Ni and Zn was 1-1000 μg L−1 and for Cr was 1-750 μg L−1. The correlation coefficient (R2) was higher than 0.993. The limits of detection were 0.23-0.55 μg L−1. The relative standard deviations (RSDs, C = 200 μg L−1, n = 7) were in the range of 2.1-3.8%. The method was successfully applied to determination of Cr, Cu, Ni and Zn in the real water samples and satisfactory relative recoveries (90-99%) were achieved.  相似文献   

15.
A green and efficient sample preparation method using a deep eutectic solvent‐based ultrasounds‐assisted dispersive liquid–liquid microextraction with solidification of the aqueous phase followed by high performance liquid chromatography analysis was developed for preconcentration and determination of heavy metals in environmental samples. In the proposed method, a novel, low density deep eutectic solvent was prepared by mixing trihexyl(tetradecyl)phosphonium chloride and thiosalicylic acid at a molar ratio of 1:2 and used both as an extractant and complexing agent. Ultrasound was used to disperse the extractant in the aqueous phase of the sample. Then, the phases were separated by centrifugation, after which the aqueous phase was frozen and the surface extractant phase was dissolved in a small volume of acetonitrile and subjected to liquid chromatographic analysis. The proposed method provided precisions (relative standard deviation, n = 5) in the range of 2.6–4.7%. The limit of detection were 0.05, 0.13, 0.06, and 0.11 µg/L for Pb(II), Cd(II), Co(II), Ni(II), respectively. The enhancement factors were equal to 154, 159, 162, and 158 for lead(II), cadmium(II), cobalt(II), and nickel(II), respectively. The accuracy of the proposed method was evaluated using certified reference materials (CA011b – hard drinking water, NIST 1643e – trace elements in water, TMRAIN‐04 – simulated rain sample).  相似文献   

16.
The paper presents the preconcentration of trace elements via electrodeposition onto a (micro)aluminum cathode in the presence of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [BMIM][PF6] as a supporting electrolyte. The advantages of the proposed method include very simple instrumentation for the preconcentration of trace elements and low-cost reagents. The experiment showed that the use of ionic liquid in the electrodeposition process significantly improves sensitivity, recovery and detection limits for the determination of trace amounts of iron, cobalt, nickel and zinc. The preconcentrated metals were determined using X-ray fluorescence spectrometry. The optimum parameters for electrodeposition such as pH, the volume of the analyzed solution, the voltage and the deposition time were studied. Under the optimized conditions, the detection limits were 5, 2, 3 and 6 μg L 1 for iron, cobalt, nickel and zinc, respectively. The precision and recovery of the method were in the range of 3–5.5%, and 92–103%, respectively. The calibration was performed using aqueous standards of Fe(III), Co(II), Ni(II) and Zn(II) in the range 0.01–0.25 mg L 1. The method was applied successfully in water analysis.  相似文献   

17.
A dispersive liquid–liquid microextraction (DLLME) method for separation/preconcentration of ultra trace amounts of Co(II) and its determination with FAAS was developed. The DLLME behavior of Co(II) using Aliquat 336-chloride as ion pairing agent was systematically investigated. The factors influencing the ion pair formation and extraction by DLLME method were optimized. Under the optimized conditions for 150 µL of extraction solvent (carbon tetrachloride), 1.5 mL disperser solvent (acetonitrile) and 5 mL of sample, the enrichment factor was 30. The detection limit was 5.6 µg L?1 and the RSD for replicate measurements of 1 mg L?1 was 1.32 %. The calibration graph using the preconcentration system for cobalt was linear from 40 to 400 µg L?1 with a correlation coefficient of 0.999. The proposed method was successfully applied for determination of cobalt in black tea, paprika and marjoram real samples.  相似文献   

18.
A simple, fast and reliable spectrophotometric method for the determination and microextraction of trace amounts of uranium using chromotrope 2R as a chelating agent and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid (IL) was used as an extractant solvent. Influence variables such as pH, volume of ligand and IL were inspected by full factorial design. In the view of Pareto chart a contour plot was studied to examine the significant variables and their interactions. The detection limit and the preconcentration factor were found to be 0.87 and 50 μg L?1, respectively. The developed method was successfully applied to ore samples.  相似文献   

19.
A selective separation and preconcentration method for the determination of gold ions in water and ore samples has been developed using dispersive liquid–liquid microextraction, followed by flame atomic absorption spectrometry. 4-Ethyl-1(2-(4-(4-nitrophenyl)piperazin-1-yl)acetyl)thiosemicarbazide) (NPPTSC) has been used for the first time as new chelating reagent. A mixture of ethanol (dispersive solvent) and carbon tetrachloride (extraction solvent) was used. Some parameters affecting the extraction procedure including the type and volume of the extracting and dispersive solvents, HNO3 concentration, the chelating agent amount, volume of sample, and foreign ions have optimized. Also, the complex formation between gold ions and the ligand has been investigated in a methanol–water solution (1:1) using UV–visible spectrometry. The spectrophotometric titration data showed that of Au–NPPTSC complex composition was found to be 3:2. After optimizing the instrumental and experimental parameters, we achieved a detection limit of 1.5 µg L?1, a preconcentration factor of 50, and a linear dynamic range of 10.0–400.0 µg L?1. The relative standard deviation obtained 2.1% at 50 µg L?1 for gold ions (n = 10). The proposed method was successfully performed for the determination of gold in certified reference material, environmental water, and ore samples.  相似文献   

20.
In this paper, we report a new liquid–liquid microextraction procedure called “nanoparticles decorated with a Schiff's base for the microextraction of Cd, Pb, Ni, and Co in environmental samples”. The developed procedure was utilized for the extraction of Cd, Pb, Ni, and Co in environmental samples. The Schiff's base was formed by reacting salicylaldehyde with 3‐aminopropyltriethoxysilane‐functionalized iron oxide nanoparticles. Analyte extraction was conducted in a capillary column system loaded with modified nanoparticles and triton X‐114 as dispersion medium. 1‐Butyl‐3‐methylimidazolium hexafluorophosphate was employed as an extraction solvent. Acidified methanol in ultrasonic bath was used as desorption solvent, and elemental determination was carried out with flame atomic absorption spectrometer. Characterization of modified nanoparticles was performed with FTIR spectroscopy and transmission electron microscopy. Solution pH, nanoparticles amount, dispersant concentration, ionic liquid, and temperature were optimized for the extraction. Detection limits obtained for Cd, Pb, Ni, and Co were 0.183, 0.201, 0.241, and 0.192 μg L?1, respectively, and enhancement factors were 79.1, 86.4, 95.7, and 82.0, respectively. The reproducibility of the developed procedure was in the range of 3.98–5.10%. Validation was checked by applying the developed procedure on certified reference water samples. The microextraction based on nanoparticles decorated with Schiff's base was successfully applied for the extraction of Cd, Pb, Ni, and Co in real environmental water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号