1.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

2.
We report a magnetic-particle (MMP)-based chemiluminescence enzyme immunoassay (CLEIA) for free prostate-specific antigen (f-PSA) in human serum. In this method, the f-PSA is sandwiched between the anti-PSA antibody coated MMPs and alkaline phosphatase (ALP)-labeled anti-f-PSA antibody. The signal produced by the emitted photons from the chemiluminescent substrate (4-methoxy-4-(3-phosphatephenyl)-spiro-(1,2-dioxetane-3,2′-adamantane)) is directly proportional to the amount of f-PSA in a sample. The present MMP-based assay can detect f-PSA in the range of 0.1–30 ng mL−1 with the detection limit of 0.1 ng mL−1. The linear detection range could match the concentration range within the “diagnostic gray zone” of serum f-PSA levels (4–10 ng mL−1). The detection limit was sufficient for measuring clinically relevant f-PSA levels (>4 ng mL−1). Furthermore, the method was highly selective; it was unaffected by cross-reaction with human glandular kallikrein-2, a kallikrein-like serine protease that is 80% similar to f-PSA. The proposed method was finally applied to determine f-PSA in 40 samples of human sera. Results obtained using the method showed high correlation with those obtained using a commercially available microplate CLEIA kit (correlation coefficient, 0.9821). This strategy shows great potential application in the fabrication of diagnostic kits for determining f-PSA in serum.  相似文献   

3.
A new kind of signal amplification strategy based on ferrocene (Fc) incorporated polystyrene spheres (PS-Fc) was proposed. The synthesized PS-Fc displayed narrow size distribution and good stability. PS-Fc was applied as label to develop immunosensors for prostate specific antigen (PSA) after the typical sandwich immunoreaction by linking anti-PSA antibody (Ab2) onto PS-Fc. After the fabrication of the immunosensor, tetrahydrofuran (THF) was dropped to dissolve PS and release the contained Fc for the following stripping voltammetric detection. PS-Fc as a new electrochemical label prevented the leakage of Fc and greatly amplified the immunosensor signal. In addition, the good biocompatibility of PS could maintain the bioactivity of the antibodies. The response current was linear to the logarithm of PSA concentration in the range from 0.01 ng mL−1 to 20 ng mL−1 with a detection limit of 1 pg mL−1. The immunosensor results were validated through the detection of PSA in serum samples with satisfactory results.  相似文献   

4.
A surface plasmon resonance (SPR) biosensor has been developed for rapid immunoassay of procalcitonin (PCT) with high detection sensitivity and reproducibility. The 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC)-activated protein A (PrA), diluted in 1% (v/v) 3-aminopropyltriethoxysilane (APTES) was dispensed on a KOH-treated Au-coated SPR chip, resulting in the covalent binding of PrA in 30 min. This “single-step” PrA immobilization strategy led to the oriented binding of the anti-PCT antibody (Ab) on a PrA-functionalized gold (Au) chip. The leach-proof immobilization procedure is five-fold faster than conventional counterparts, enabling high detection specificity and reproducibility. The IA detects 4–324 ng mL−1 of PCT with a limit of detection (LOD) and a limit of quantification (LOQ) of 4.2 ng mL−1 and 9.2 ng mL−1, respectively. It was capable of detecting PCT in real sample matrices and patient samples with high precision. The Ab-bound SPR chips were stable for more than five weeks.  相似文献   

5.
Gold nanorods (AuNRs) integrated with ZnCdHgSe near-infrared quantum dots (AuNRs-ZnCdHgSe QDs) were successfully synthesized and characterized by transmission electron microscope, X-ray photoelectron spectroscopy, and X-ray diffraction. A glassy carbon electrode was decorated with the aforementioned AuNRs-ZnCdHgSe QDs nanocomposite, which provides a biocompatible interface for the subsequent immobilization of prostate specific antibody (anti-PSA). After being successively treated with glutaraldehyde vapor and bovine serum albumin solution, a photoelectrochemical immunosensing platform based on anti-PSA/AuNRs-ZnCdHgSe QDs/GCE was established. The photocurrent response of ZnCdHgSe QDs was tremendously improved by AuNRs due to the effect of resonance energy transfer which can be deduced from the dependence of the enhanced efficiency on the AuNRs with different length-to-diameter ratios and spectral absorption characteristics. A maximum photocurrent was obtained when the absorption spectrum of AuNRs matched well with the emission spectrum of ZnCdHgSe QDs. A photoelectrochemical immunosensor for prostate specific antigen (PSA) was achieved by monitoring the photocurrent variation. The photocurrent variation before and after being interacted with PSA solution exhibits a good linear relationship with the logarithm of its concentration (logcPSA) in the range from 1.0 pg mL−1 to 50.0 ng mL−1. The detection limit of this photoelectrochemical immunosensor is able to reach 0.1 pg mL−1 (S/N = 3). Determining PSA in clinical human serum was also demonstrated by using the developed anti-PSA(BSA)/AuNRs-ZnCdHgSe QDs/GCE electrode. The results were comparable with those obtained from an enzyme-linked immunosorbent assay method.  相似文献   

6.
The rapid simultaneous determination of cadmium, lead, copper, and mercury ions is performed by employing a disposable sensor modified with graphene oxide (GO) doped diaminoterthiophene (GO/DTT) for chronocoulometry (CC). The performances of CC with and without pre-deposition in two opposite potential step directions were compared with square wave anodic stripping voltammetry (SWASV) under various conditions. The surface of the GO/DTT modified screen print carbon electrode (SPCE) was characterized by SEM, EDXS, and electrochemical impedance spectroscopy (EIS). Experimental variables that affect the response signal such as the pH, deposition time, type of supporting electrolyte, concentration of DTT, content ratio of GO to DTT, and Nafion content were optimized. Interference effects due to other heavy metal ions were also investigated. The dynamic ranges of SWASV and CC were between 1 ng mL−1 and 2.5 μg mL−1 and between 1 ng mL−1 and 10 μg mL−1, respectively. The detection limits for Cd2+, Pb2+, Cu2+, Hg2+ ions were 1.9 ± 0.4 ng mL−1, 2.8 ± 0.6 ng mL−1, 0.8 ± 0.2 ng mL−1, and 2.6 ± 0.9 ng mL−1 for the CC stripping method; 2.6 ± 0.2 ng mL−1, 0.5 ± 0.1 ng mL−1, 1.8 ± 0.3 ng mL−1, and 3.2 ± 0.3 ng mL−1 for the CC deposition method; and 7.1 ± 0.9, 1.9 ± 0.3, 0.4 ± 0.1, and 0.7 ± 0.1 ng mL−1 for SWASV. The reliability of the method for point-of-analysis was evaluated by analyzing a urine standard reference material and some water samples.  相似文献   

7.
We established a simultaneous bioluminescent assay utilizing aequorin (Aq) and biotinylated firefly luciferase (b-Luc); furthermore, we developed a highly sensitive and rapid tandem bioluminescent immunoassay (BLIA) involving the Aq-labeled Fab fragment and b-Luc-streptavidin complex. Minimum detection limits of Aq and b-Luc were 9.4 × 10−21 mol assay−1 (blank + 3S.D.) and 3.6 × 10−19 mol assay−1 (blank + 3S.D.), respectively. Measurements of two luminescent proteins were completed in 4 s with a single assay medium. In this study, prostatic acid phosphatase (PAP) and prostate specific antigen (PSA), which served as analytes, were measured in the tandem BLIA. PAP and PSA were detected by the Aq-labeled anti-Dig Fab fragment and b-Luc-streptavidin complex, respectively. The measurable ranges of PAP and PSA were 0.04-100 and 0.2-200 ng mL−1, respectively. This technique was also applied to the simultaneous measurement of PSA and α-fetoprotein (AFP). Measurable ranges of PSA and AFP were 0.2-200 and 1.95-1000 ng mL−1, respectively. Levels of PAP and PSA or PSA and AFP in human serum could be accurately determined with the proposed BLIA. Satisfactory correlations were observed between results obtained from the proposed BLIA and those derived from commercial kits.  相似文献   

8.
We report on a disposable microdevice suitable for sandwich-type electrochemiluminescence (ECL) detection of prostate specific antigen (PSA). The method is making use of ZnO quantum dots dotted carbon nanotube (ZnO@CNT) and simply electrochemical reduced Pt/Au alloy. The latter was selected as immunosensing probe to modify screen-printed carbon electrode, due to its excellent electrical property. For further ultrasensitive, low-potential and stable ECL detection, ZnO@CNT composite was first synthesized using a facile solvothermal method, and employed as signal amplification label. In this work, two working electrodes in one device were used for one determination to obtain more exact results based on screen-print technique. Taking advantage of dual-amplification effects of the Pt/Au and ZnO@CNT, this immunosensor could detect the PSA quantitatively, in the range of 0.001–500 ng mL−1, with a low detection limit of 0.61 pg mL−1. The resulting versatile immunosensor possesses high sensitivity, satisfactory reproducibility and regeneration. This simple and specific strategy has vast potential to be used in other biological assays.  相似文献   

9.
A novel electrochemical immunosensor based on double signal amplification of enzyme-encapsulated liposomes and biocatalytic metal deposition was developed for the detection of human prostate specific antigen (PSA). Alkaline phosphatase (ALP)-encapsulated and detection antibody-functionalized liposomes were first prepared and used as the detection reagent. In the sandwich immunoassay, the model analyte PSA was first captured by anti-PSA capture antibody immobilized on the electrode and then sandwiched with the functionalized liposomes. The bound liposomes were then lysed with surfactant to release the encapsulated ALP, which served as secondary signal amplification means. ALP on the electrode surface initiated the hydrolysis of ascorbic acid 2-phosphate (AA-p) to produce ascorbic acid. The latter, in turn, reduced silver ions on the electrode surface, leading to deposition of the metal silver on the electrode surface. Linear sweep voltammetry (LSV) was chosen to detect the amount of the deposited silver. The results showed that the anodic stripping peak current was linearly dependent on the PSA concentration in the range of 0.01-100 ng mL−1, and a detection limit as low as 0.007 ng mL−1 can be obtained. Since the cut-off value of human PSA is 4 ng mL−1, the proposed electrochemical immunosensor would be expected to gain widespread applications for the detection of PSA in clinical diagnosis.  相似文献   

10.
A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB1 was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB1 were 2.69 and 0.35 ng mL−1, respectively, with a linear range of 0.93–7.73 ng mL−1. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL−1, and the IC50 was 0.89 ± 0.09 ng mL−1 with a linear range of 0.29–2.68 ng mL−1. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB1 contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems.  相似文献   

11.
In this work, a sandwich-type electrochemical immunosensor for simultaneous sensitive detection of prostate specific antigen (PSA) and free prostate specific antigen (fPSA) is fabricated. Gold nanoparticles (AuNPs) modified Prussian blue and nickel hexacyanoferrates nanoparticles were firstly prepared, respectively, and then decorated onion-like mesoporous graphene sheets (denoted as Au@PBNPs/O-GS and Au@NiNPs/O-GS) as distinguishable signal tags to label different detection antibodies. Subsequently, streptavidin and biotinylated alkaline phosphatase (bio-AP) were employed to block the possible remaining active sites. With the employment of the as prepared nanohybrids, the dual catalysis amplification can be achieved by catalysis of the ascorbic acid 2-phosphate to in situ produce AA in the presence of bio-AP, and then AA was further catalyzed by Au@PBNPs/O-GS and Au@NiNPs/O-GS nanohybrids, respectively, to obtain the higher signal responses. The experiment results show that the linear range of the proposed immunosensor for simultaneous determination of fPSA is from 0.02 to 10 ng mL−1 with a detection limit of 6.7 pg mL−1 and PSA is from 0.01 to 50 ng mL−1 with a detection limit of 3.4 pg mL−1 (S/N = 3). Importantly, the proposed method offers promise for rapid, simple and cost-effective analysis of biological samples.  相似文献   

12.
This paper presents a novel approach to electrochemically determine enzymatically active PSA using ferrocene-functionalized helix peptide (CHSSLKQK). The principle of electrochemical measurement is based on the specific proteolytic cleavage events of the FC-peptide on the gold electrode surface in the presence of PSA, resulting the change of the current signal of the electrode. The percentage of the decreased current is linear with the concentration of active PSA at the range of 0.5–40 ng mL?1 with a detection limit of 0.2 ng mL?1. The direct transduction of peptide cleavage events into an electrical signal provides a simple, sensitive method for detecting the enzymatic activity of PSA and determining the active PSA concentration.  相似文献   

13.
Nitrogen-doped carbon quantum dots (N-CQDs) with an average diameter of 2 nm were synthesized by carbonization of diethylene triamine pentacetate acid (DTPA). The simple prepared N-CQDs showed excellent electrochemiluminescence (ECL) property and were used as luminophors to fabricate a sandwich-type ECL immunosensor. Aminated graphene (NH2-G) was also synthesized and used as a label of secondary antibody. The labeled NH2-G could effectively quench the ECL of N-CQDs modified on electrodes due to ECL resonance energy transfer (ERET). Immunological recognition which induced ECL quenching enabled the quantitative determination of biomarkers. Alpha fetoprotein (AFP) was selected as a model analyte to investigate the analytical performance of the proposed immunosensor. Under optimal conditions, a good linear relationship between ECL intensity and the logarithm of AFP concentration was obtained in the range of 0.01–100 ng mL−1 with the detection limit of 3.3 pg mL−1. The proposed ECL immunosensor showed good stability, acceptable selectivity and reproducibility.  相似文献   

14.
Three-dimensional macroporous gold nanoparticles/graphene composites (3D-AuNPs/GN) were synthesized through a simple two-step process, and were used to modify working electrode sensing platform, based on which a facile electrochemical immunoassay for sensitive detection of carcinoembryonic antigen (CEA) in human serum was developed. In the proposed 3D-AuNPs/GN, AuNPs were distributed not just on the surface, but also on the inside of graphene. And this distribution property increased the area of sensing surface, resulting in capturing more primary antibodies as well as improving the electronic transmission rate. In the presence of CEA, a sandwich-type immune composite was formed on the sensing platform, and the horseradish peroxidase-labeled anti-CEA antibody (HRP-Ab2)/thionine/nanoporous silver (HRP-Ab2/TH/NPS) signal label was captured. Under optimal conditions, the electrochemical immunosensor exhibited excellent analytical performance: the detection range of CEA is from 0.001 to 10 ng mL−1 with low detection limit of 0.35 pg mL−1 and low limit of quantitation (LOQ) of 0.85 pg mL−1. The electrochemical immunosensor showed good precision, acceptable stability and reproducibility, and could be used for the detection of CEA in real samples. The proposed method provides a promising platform of clinical immunoassay for other biomolecules  相似文献   

15.
Gao X  Zhang Y  Wu Q  Chen H  Chen Z  Lin X 《Talanta》2011,85(4):1980-1985
A simple and controllable one-step electrodeposition method for the preparation of a chitosan-carbon nanotubes-gold nanoparticles (CS-CNTs-GNPs) nanocomposite film was used to fabricate an immunosensor for detection of carcinoembryonic antigen (CEA). The porous three-dimensional CS-CNTs-GNPs nanocomposite film, which offered a large specific surface area for immobilization of antibodies, exhibited improved conductivity, high stability and good biocompatibility. The morphology of the formed nanocomposite film was investigated by scanning electron microscopy (SEM), and the electrochemical behaviors of the immunosensor were characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Under the optimal conditions, the proposed immunosensor could detect CEA in two linear ranges from 0.1 to 2.0 ng mL−1 and from 2.0 to 200.0 ng mL−1, with a detection limit of 0.04 ng mL−1. The immunosensor based on CS-CNTs-GNPs nanocomposite film as the antibody immobilization matrix could exhibit good sensitivity, stability, and reproducibility for the determination of CEA.  相似文献   

16.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed.  相似文献   

17.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

18.
Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for human health. An analytical method based on direct injection of 5 μL urine into an ultra performance liquid chromatography system coupled to a time-of-flight mass spectrometry has been developed and validated to monitor exposure to organophosphate triesters through their respective dialkyl and diaryl phosphate metabolites (DAPs). The targeted analytes were: di-n-butyl phosphate (DNBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP) and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Separation was achieved in less than 3 min on a short column with narrow diameter and small particle size (50 mm × 2.1 mm × 1.7 μm). Different mobile phases were explored to obtain optimal sensitivity. Acetonitrile/water buffered with 5 mM of ammonium hydroxide/ammonium formate (pH 9.2) was the preferred mobile phase. Quantification of DAPs was performed using deuterated analogues as internal standards in synthetic urine (averaged DAP accuracy was 101%; RSD 3%). Low method limits of quantification (MLQ) were obtained for DNBP (0.40 ng mL−1), DPHP (0.10 ng mL−1), BDCIPP (0.40 ng mL−1) and BBOEP (0.60 ng mL−1), but not for the most polar DAPs, BCEP (∼12 ng mL−1) and BCPP (∼25 ng mL−1). The feasibility of the method was tested on 84 morning urine samples from 42 mother and child pairs. Only DPHP was found above the MLQ in the urine samples with geometric mean (GM) concentrations of 1.1 ng mL−1 and 0.57 ng mL−1 for mothers and children respectively. BDCIPP was however, detected above the method limit of detection (MLD) with GM of 0.13 ng mL−1 and 0.20 ng mL−1. While occasionally detected, the GM of DNBP and BBOEP were below MLD in both groups.  相似文献   

19.
Su AK  Chang YS  Lin CH 《Talanta》2004,64(4):970-974
A simple, inexpensive and reliable method for the routine analysis of riboflavin in beer by capillary electrophoresis-light emitting diode (CE-LED) induced fluorescence detection is described. A simple and straightforward sample preparation is involved and the method is based on an inexpensive blue LED as the light source combined with an on-line sample concentration technique. For this detection system, using a normal micellar electrokinetic chromatography (MEKC), stacking-MEKC and dynamic pH junction techniques, the detection limits were found to be 480, 20 and 1 ng mL−1, respectively. In addition, the number of theoretical plates for riboflavin was determined to be 3.8×104 by means of a dynamic pH junction and this was improved to 3.2×106 when the dynamic pH junction-sweeping mode was applied. The concentrations of riboflavin in 12 samples of different types of commercial beer were found to be in the range of 130-280 ng mL−1.  相似文献   

20.
The carbon nanotubes (CNTs) assisted strategy has been proposed for insulin sensing and insulin proteolysis analysis. Experiments demonstrated that this strategy could be used for trace insulin determination with a low detection limit 7.75 ng mL−1 (S/N = 3) and a detection range from 20 ng mL−1 to 400 ng mL−1. Both biocompatibility and intrinsic conductivity of pristine CNTs enabled them to act an excellent biosensing platform for the realization of direct electrochemistry and electrocatalysis of insulin. Compared with the present methods, the proposed strategy could realize the trace insulin detection without electrode modifications. It is more convenient and simpler than those based on the chemically modified electrodes. This method also made the CNTs as the indicator for insulin proteolysis analysis so that the biological process could be studied by electron microscope, electrochemical methods and digital camera. CNTs obtained after the proteolysis showed the same capabilities as the pristine ones in electrochemical signal enhancement and could participate in the bio-circle repeatedly.  相似文献   