首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A novel electrochemical immunoassay was developed based on the signal amplification strategy of silver deposition directed by gold nanorods (AuNRs), which was in-situ assembled on the sandwich immunocomplex. The superstructure formed by the self-assembly of AuNRs provided abundant active sites for the nucleation of silver nanoparticles. In this pathway, the stripping current of silver was greatly enhanced. Using human immunoglobulin G (HIgG) as a model analyte, the ultrasensitive immunoassay showed a wide linear range of six orders of magnitude from 0.1 fg mL−1 to 100 pg mL−1, with the low detection limit down to 0.08 fg mL−1. The practicality of this electrochemical immunoassay for detection of HIgG in serum was validated with the average recovery of 93.9%. In addition, this enzyme-free immunoassay also has the advantages of acceptable reproducibility and specificity, and thus this immunosensing protocol can be extended to the detection of other low-abundant protein biomarkers.  相似文献   

2.
A novel electrochemical redox-active nanocomposite was synthesized by a one-pot method using N,N′-diphenyl-p-phenylediamine as monomer, and HAuCl4 and K2PtCl4 as co-oxidizing agents. The as-prepared poly(N,N′-diphenyl-p-phenylediamine)-Au/Pt exhibited admirable electrochemical redox activity at 0.15 V, excellent H2O2 electrocatalytic ability and favorable electron transfer ability. Based on these, the evaluation of the composite as sensing substrate for label-free electrochemical immunosensing to the sensitive detection of carbohydrate antigen 199 was described. This technique proved to be a prospective detection tool with a wide liner range from 0.001 U mL−1 to 40 U mL−1, and a low detection limit of 2.3 × 10−4 U mL−1 (S/N = 3). In addition, this method was used for the analysis of human serum sample, and good agreement was obtained between the values and those of enzyme-linked immunosorbent assay, implying the potential application in clinical research. Importantly, the strategy of the present substrate could be extended to other polymer-based nanocomposites such as polypyrrole derivatives or polythiophene derivatives, and this could be of great significance for the electrochemical immunoassay.  相似文献   

3.
A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB1 was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB1 were 2.69 and 0.35 ng mL−1, respectively, with a linear range of 0.93–7.73 ng mL−1. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL−1, and the IC50 was 0.89 ± 0.09 ng mL−1 with a linear range of 0.29–2.68 ng mL−1. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB1 contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems.  相似文献   

4.
In this paper, gold nanoparticles coated with palladium dots (Pd@Au) bimetallic nanostructures have been reported to have a peroxidase like activity which is not found in their monometallic counterparts. Based on this finding, we have developed an immunoassay in which antibody-modified Pd@Au nanostructure catalyzes the dimerization of a fluorogenic substrate for peroxidase, 3-(4-dihydroxy phenyl) propionic acid (HPPA), to generate high fluorescence signal. Specific antibodies against bensulfuron-methyl were generated by using a well characterized bensulfuron–protein conjugate as an immunogen, and the assay was performed in a competitive immunoassay format where Pd@Au nanostructure was bound to secondary antibody to show the peroxidase like activity. The developed immunoassay exhibited an excellent sensitivity showing a dynamic response range from 0.001 to 100 ng mL−1 for herbicide bensulfuron-methyl with a detection limit of 0.01 ng mL−1 (n = 3). The newly synthesized bimetallic nanostructure shows the advantages of low cost, easy synthesis and tunable catalytic activity, making it a promising substitution of enzyme peroxidase in different applications.  相似文献   

5.
Silver nanoclusters and graphene oxide nanocomposite (AgNCs/GRO) is synthesized and functionalized with detection antibody for highly sensitive electrochemical sensing of carcinoembryonic antigen (CEA), a model tumor marker involved in many cancers. AgNCs with large surface area and abundant amount of low-coordinated sites are synthesized with DNA as template and exhibit high catalytic activity towards the electrochemical reduction of H2O2. GRO is employed to assemble with AgNCs because it has large specific surface area, super electronic conductivity and strong π-π stacking interaction with the hydrophobic bases of DNA, which can further improve the catalytic ability of the AgNCs. Using AgNCs/GRO as signal amplification tag, an enzyme-free electrochemical immunosensing protocol is designed for the highly sensitive detection of CEA on the capture antibody functionalized immunosensing interface. Under optimal conditions, the designed immunosensor exhibits a wide linear range from 0.1 pg mL−1 to 100 ng mL−1 and a low limit of detection of 0.037 pg mL−1. Practical sample analysis reveals the sensor has good accuracy and reproducibility, indicating the great application prospective of the AgNCs/GRO in fabricating highly sensitive immunosensors, which can be extended to the detection of various kinds of low abundance disease related proteins.  相似文献   

6.
Methods based on immunoassays have been developed for cardiac biomarkers, but most involve the low sensitivity and are unsuitable for early disease diagnosis. Herein we design an electrochemical immunoassay for sensitive detection of myoglobin (a cardiac biomarker for acute myocardial infarction) by using nanogold-penetrated poly(amidoamine) dendrimer (AuNP-PAMAM) for signal amplification without the need of natural enzymes. The assay was carried out on the monoclonal mouse anti-myoglobin (capture) antibody-anchored glassy carbon electrode using polyclonal rabbit anti-myoglobin (detection) antibody-labeled AuNP-PAMAM as the signal tag. In the presence of target myoglobin, the sandwiched immunocomplex could be formed between capture antibody and detection antibody. Accompanying AuNP-PAMAM, the carried gold nanoparticles could be directly determined via stripping voltammetric method under acidic conditions. Under optimal conditions, the detectable electrochemical signal increased with the increasing target myoglobin in the sample within a dynamic working range from 0.01 to 500 ng mL−1 with a detection limit of 3.8 pg mL−1. The electrochemical immunoassay also exhibited high specificity and good precision toward target myoglobin. Importantly, our strategy could be applied for quantitative monitoring of myoglobin in human serum specimens, giving well matched results with those obtained from commercialized enzyme-linked immunosorbent assay (ELISA) method.  相似文献   

7.
Here we designed a new electrochemical immunoassay protocol for determination of carcinoembryonic antigen (CEA) using nanoplatinum-enclosed gold nanocores (Pt@Au) as catalytically promoted nanolabels on the carbon nanospheres and graphene-modified immunosensor. The Pt@Au nanolabels were synthesized and functionalized with monoclonal anti-CEA antibodies and glucose oxidase (GOx). Using the functional Pt@Au nanolabels as molecular tags, the assay was implemented relative to glucose–hydroquinone system with a sandwich-type immunoassay. Initially, the added glucose was oxidized to gluconolactone and H2O2 by the labeled GOx, and then the generated H2O2 was reduced with the help of platinum nanoparticles, leading to the production of oxygen. The self-produced oxygen could promote the re-oxidation of the glucose, thus resulting in the dual amplification of the electrochemical signal. Several nanolabels, such as multiarmed star-like platinum nanowires, hollow platinum nanospheres and Pt@Au nanostructures, were investigated for CEA detection and improved analytical features were obtained with the Pt@Au nanostructures. Under optimal conditions, the Pt@Au-based immunoassay displayed a wide working range from 0.001 to 120 ng mL−1 with a low detection limit of 0.5 pg mL−1 CEA at 3sB. Intra- and inter-assay coefficients of variation were <10.9%. The system was evaluated with 10 clinical serum samples, receiving good accordance with results from enzyme-linked immunosorbent assay method.  相似文献   

8.
The present study described a novel fluorescence enzyme-linked immunosorbent assay (ELISA) used to detect ochratoxin A (OTA) by using the glucose oxidase (GOx)-mediated fluorescence quenching of mercaptopropionic acid-capped CdTe quantum dots (MPA-QDs), in which GOx was used as an alternative to horseradish peroxidase (HRP) for the oxidization of glucose into hydrogen peroxide (H2O2) and gluconic acid. The MPA-QDs were used as a fluorescent signal output, whose fluorescence variation was extremely sensitive to the presence of H2O2 or hydrogen ions in the solution. Under the optimized conditions, the proposed fluorescence ELISA demonstrated a good linear detection of OTA in corn extract from 2.4 pg mL−1 to 625 pg mL−1 with a limit of detection of 2.2 pg mL−1, which was approximately 15-fold lower than that of conventional HRP-based ELISA. Our developed fluorescence immunoassay was also similar to HRP-based ELISA in terms of selectivity, accuracy, and reproducibility. In summary, this study was the first to use the GOx-mediated fluorescence quenching of QDs in immunoassay to detect OTA, offering a new possibility for the analysis of other mycotoxins and biomolecules.  相似文献   

9.
Methods based on nanomaterial labels have been developed for electrochemical immunosensors and immunoassays, but most involved low sensitivity. Herein a novel class of molecular tags, nanogold–polyaniline–nanogold microspheres (GPGs), was first synthesized and functionalized with horseradish peroxidase-conjugated thyroid-stimulating hormone antibody (HRP-Ab2) for sensitive electrochemical immunoassay of thyroid-stimulating hormone (TSH). X-ray diffraction, confocal Raman spectroscopy, scanning electron microscope and transmission electron microscope were employed to characterize the prepared GPGs. Based on a sandwich-type immunoassay format, the assay was performed in pH 5.0 acetate buffer containing 6.0 mmol L−1 H2O2 by using GPG-labeled HRP-Ab2 as molecular tags. Compared with pure polyaniline nanospheres and gold nanoparticles alone, the GPG hybrid nanostructures increased the surface area of the nanomaterials, and enhanced the immobilized amount of HRP-Ab2. Several labeling protocols comprising HRP-Ab2, nanogold particle-labeled HRP-Ab2, and polyaniline nanospheres-labeled HRP-Ab2, were also investigated for determination of TSH and improved analytical features were obtained by using the GPG-labeled HRP-Ab2. With the GPG labeling method, the effects of incubation time and pH of acetate buffer on the current responses of the immunosensors were also studied. The strong attachment of HRP-Ab2 to the GPGs resulted in a good repeatability and intermediate precision down to 7%. The dynamic concentration range spanned from 0.01 to 20 μIU mL−1 with a detection limit (LOD) of 0.005 μIU mL−1 TSH at the 3sB criterion. Significantly, no significant differences at the 0.05 significance level were encountered in the analysis of 15 spiking serum samples between the developed electrochemical immunoassay and the commercially available enzyme-linked immunosorbent assay (ELISA) method for determination of TSH.  相似文献   

10.
A novel class of redox-active molecular tags, poly(o-phenylenediamine)-carried nanogold particles (GPPDs), was first synthesized and functionalized with horseradish peroxidase-anti-prolactin conjugates (HRP-anti-PRL). Thereafter, a specific sandwich-type electrochemical immunoassay was designed for determination of prolactin (PRL) by using GPPD-labeled HRP-anti-PRL conjugates as molecular tags on anti-PRL antibody-modified glassy carbon electrode. Compared with pure gold nanoparticles and poly(o-phenylenediamine) microspheres, the as-prepared GPPDs increased the surface coverage of the nanostructures, and enhanced the immobilization amount of biomolecules. Several labeling protocols compromising GPPD-labeled HRP-anti-PRL, nanogold particles-labeled HRP-anti-PRL and poly(o-phenylenediamine) microspheres-labeled HRP-anti-PRL, were investigated for detection of PRL, and improved analytical features were obtained with the GPPD-based strategy. With the GPPD labeling method, dependence of the electrochemical signals on the incubation time and pH of the assay solution were also studied. The strong attachment of HRP-anti-PRL to the GPPDs resulted in a good repeatability and intermediate reproducibility down to 9.8%. The dynamic concentration range spanned from 0.5 to 180 ng mL−1 PRL with a detection limit of 0.1 ng mL−1 at the 3Sblank level. No significant differences at the 95% confidence level were encountered in the analysis of 10 spiked blank cattle serum samples between the developed immunoassay and enzyme-linked immunosorbent assay method for determination of PRL.  相似文献   

11.
Caifeng Ding  Fei Zhao  Jin-Ming Lin 《Talanta》2009,78(3):1148-4751
A novel and effective electrochemical immunosensor for the rapid determination of α-fetoprotein (AFP) based on carbon paste electrode (CPE) consisting of room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) and graphite. The surface of the CPE was modified with gold nanoparticles for the immobilization of the α-fetoprotein antibody (anti-AFP). By sandwiching the antigen between anti-AFP on the CPE modified with gold nanoparticles and the secondary antibody, polyclonal anti-human-AFP labeled with horseradish peroxidase (HRP-labeled anti-AFP), the immunoassay was established. The concentration of AFP was determined based on differential pulse voltammetry (DPV) signal, which was generated in the reaction between O-aminophenol (OAP) and H2O2 catalyzed by HRP labeled on the sandwich immunosensor. AFP concentration could be measured in a linear range of 0.50-80.00 ng mL−1 with a detection limit of 0.25 ng mL−1. The immunosensor exhibited high sensitivity and good stability, and would be valuable for clinical assay of AFP.  相似文献   

12.
A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to functionalize the plate surface with amino groups for covalent linkage to small molecular hapten with carboxyl groups. The modified plates showed significantly high antibody binding in comparison to plates coated with hapten-carrier protein conjugates and presented excellent stability as a function of the buffer pH and reaction time. The developed assay employing direct hapten coated plates and using affinity purified atrazine and 2,4-D antibodies demonstrated very high sensitivity, IC50 values for atrazine and 2,4-D equal to 0.8 ng mL−1 and 7 ng mL−1, respectively. The assay could detect atrazine and 2,4-D levels in standard water samples even at a very low concentration upto 0.02 and 0.7 ng mL−1 respectively in the optimum working range between 0.01 and 1000 ng mL−1 with good signal reproducibility (p values: 0.091 and 0.224 for atrazine and 2,4-D, respectively). The developed immunoassay format could be used as convenient quantitative tool for the sensitive screening of pesticides in samples.  相似文献   

13.
A new and disposable electrochemical immunosensor was designed for detection of alpha-fetoprotein (AFP), as a model analyte, with sensitivity enhancement based on enzyme-catalyzed silver deposition onto irregular-shaped gold nanoparticles (ISGNPs). The assay was carried out with a sandwich-type immunoassay protocol by using ISGNP-labeled anti-AFP antibodies conjugated with alkaline phosphatase (ALP–Ab2) as detection antibodies. The enzymatically catalytic deposition of silver on the electrode could be measured by stripping analysis in KCl solution due to the Ag/AgCl solid-state voltammetric process. Several labeling protocols including spherical gold nanoparticle-labeled ALP–Ab2 and ISGNP-labeled ALP–Ab2 were investigated for determination of AFP, and improved analytical properties were achieved with the ISGNP labeling. With the ISGNP labeling method, the effects of incubation time and incubation temperature for antigen-antibody reaction, and deposition time of silver on the current responses of the electrochemical immunosensors were also monitored. Under optimal conditions, the electrochemical immunosensor exhibited a wide dynamic range from 0.01 ng mL−1 to 200 ng mL−1 with a detection limit of 5.0 pg mL−1 AFP. The immunosensor displayed a good stability and acceptable reproducibility and accuracy. No significant differences at the 95% confidence level were encountered in the analysis of 10 clinical serum samples between the developed immunoassay and the commercially available electrochemiluminescent method for determination of AFP.  相似文献   

14.
Nanoporous gold (NPG) has recently received considerable attention in analytical electrochemistry because of its good conductivity and large specific surface area. A facile layer-by-layer assembly technique fabricated NPG was used to construct an electrochemical immunosensor for carcinoembryonic antigen (CEA). NPG was fabricated on glassy carbon (GC) electrode by alternatively assembling gold nanoparticles (AuNPs) and silver nanoparticles (AgNPs) using 1,4-benzenedimethanethiol as a cross-linker, and then AgNPs were dissolved with HNO3. The thionine was absorbed into the NPG and then gold nanostructure was electrodeposited on the surface through the electrochemical reduction of gold chloride tetrahydrate (HAuCl4). The anti-CEA was directly adsorbed on gold nanostructure fixed on the GC electrode. The linear range of the immunosensor was from 10 pg mL−1 to 100 ng mL−1 with a detection limit of 3 pg mL−1 (S/N = 3). The proposed immunosensor has high sensitivity, wide linear range, low detection limit, and good selectivity. The present method could be widely applied to construct other immunosensors.  相似文献   

15.
A simple and sensitive electrochemical immunoassay protocol was developed for the detection of carcinoembryonic antigen (CEA) using nanosilver-doped DNA polyion complex membrane (PIC) as sensing interface. To construct such an immunosensor, double-stranded DNA was initially assembled onto the surface of thionine/Nafion-modified screen-printed carbon electrode to adsorb silver ions with positive charges, then silver ions were reduced to nanosilver particles with the aid of NaBH4, and then anti-CEA antibodies were immobilized on the nanosilver surface. Gold nanoparticles conjugated with horseradish peroxidase-labeled anti-CEA were employed as signal antibodies for the detection of CEA with a sandwich-type assay format. Under optimal conditions, the immunosensor exhibited a dynamic range of 0.03-32 ng mL−1 with a low detection limit of 10 pg mL−1 CEA. Intra- and inter-assay imprecision (CVs) were <9.5% and 6.5%, respectively. The response could remain 90.1% of the original current at 30th day. 50 real samples were evaluated using the immunosensor and the enzyme-linked immunosorbent assay, respectively, and received in accordance with those two methods.  相似文献   

16.
In this study, using mycotoxin deoxynivalenol (DON) as a model hapten, we developed a nanobody-based environmental friendly immunoassay for sensitive detection of DON. Two nanobodies (N-28 and N-31) which bind to anti-DON monoclonal antibody (MAb) were isolated from a naive phage display library. These nanobodies are clonable, thermally stable and mycotoxin-free products and can be served as coating antigen mimetics in heterologous immunoassay. The half inhibition concentration (IC50) of the immunoassay developed with N-28 and N-31 was 8.77 ± 0.41 ng mL−1 and 19.97 ± 0.84 ng mL−1, respectively, which were 18- and 8-fold more sensitive than the conventional coating antigen (DON-BSA) based immunoassay. In order to better understand the molecular mechanism of antigen mimicry by nanobody, the 3D structure of “nanobody (N-28) - anti-DON MAb” complex was presented and verified by molecular modeling and alanine-scanning mutagenesis. The results showed that hydrogen bond and hydrophobic interaction formed between Thr 102 – Ser 106 of N-28 and CDR H3 residues of anti-DON antibody may contribute to their binding. This novel concept of enhancing sensitivity of immunoassay for DON based on nanobody may provide potential applications in a general method for immunoassay of various food chemical contaminants.  相似文献   

17.
Three-dimensional macroporous gold nanoparticles/graphene composites (3D-AuNPs/GN) were synthesized through a simple two-step process, and were used to modify working electrode sensing platform, based on which a facile electrochemical immunoassay for sensitive detection of carcinoembryonic antigen (CEA) in human serum was developed. In the proposed 3D-AuNPs/GN, AuNPs were distributed not just on the surface, but also on the inside of graphene. And this distribution property increased the area of sensing surface, resulting in capturing more primary antibodies as well as improving the electronic transmission rate. In the presence of CEA, a sandwich-type immune composite was formed on the sensing platform, and the horseradish peroxidase-labeled anti-CEA antibody (HRP-Ab2)/thionine/nanoporous silver (HRP-Ab2/TH/NPS) signal label was captured. Under optimal conditions, the electrochemical immunosensor exhibited excellent analytical performance: the detection range of CEA is from 0.001 to 10 ng mL−1 with low detection limit of 0.35 pg mL−1 and low limit of quantitation (LOQ) of 0.85 pg mL−1. The electrochemical immunosensor showed good precision, acceptable stability and reproducibility, and could be used for the detection of CEA in real samples. The proposed method provides a promising platform of clinical immunoassay for other biomolecules  相似文献   

18.
A new strategy was introduced for ssDNA immobilization on a modified glassy carbon electrode. The electrode surface was modified using polyaniline and chemically reduced graphene oxide decorated cerium oxide nanoparticles (CeO2NPs-RGO). A single-stranded DNA (ssDNA) probe was immobilized on the modified electrode surface. Fast Fourier transform square wave voltammetry (FFT-SWV) was applied as detection technique and [Ru(bpy)3]2+/3+ redox signal was used as electrochemical marker. The hybridization of ssDNA with its complementary target caused a dramatic decrease in [Ru(bpy)3]2+/3+ FFT-SW signal. The proposed electrochemical biosensor was able to detect Aeromonas hydrophila DNA oligonucleotide sequence encoding aerolysin protein. Under optimal conditions, the biosensor showed excellent selectivity toward complementary sequence in comparison with noncomplementary and two-base mismatch sequences. The dynamic linear range of this electrochemical DNA biosensor for detecting 20-mer oligonucleotide sequence of A. hydrophila was from 1 × 10−15 to 1 × 10−8 mol L−1. The proposed biosensor was successfully applied for the detection of DNA extracted from A. hydrophila in fish pond water up to 0.01 μg mL−1 with RSD of 5%. Besides, molecular docking was applied to consider the [Ru(bpy)3]2+/3+ interaction with ssDNA before and after hybridization.  相似文献   

19.
An amperometric immunoassay for the determination of tumor necrosis factor alpha (TNFα) protein biomarker in human serum based on the use of magnetic microbeads (MBs) and disposable screen-printed carbon electrodes (SPCEs) has been developed. The specifically modified microbeads were magnetically captured on the working electrode surface and the amperometric responses were measured at −0.20 V (vs. Ag pseudo-reference electrode), upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. After a thorough optimization of the assay, extremely low limits of detection were achieved: 2.0 pg mL−1 (36 fM) and 5.8 pg mL−1 (105 fM) for standard solutions and spiked human serum, respectively. The simplicity, robustness and this clinically interesting LOD proved the developed TNFα immunoassay as a good contender for real clinical application.  相似文献   

20.
The paper reports a highly sensitive enzyme free electrochemical immunoassay (EFEIA) for the detection of herbicide chlorsulfuron. The assay is based upon oxidative gold nanoparticle (GNP) dissolution in an acidic solution. The consequent release of large amounts of gold (Au) metal ions after dissolution of gold nanoparticles tagged to antibody leads to the development of sensitive stripping voltammetry based immunoassay. The detection is made possible by the reduction of Au3 + ions at the screen printed electrode surface followed by metal analysis by using the square wave voltammetry technique. The sensitivity of chlorsulfuron detection by competitive assay procedure was 6.7 pg mL− 1 for EFEIA in marked contrast to optical detection using Standard ELISA procedure that gives a sensitivity of 4.97 ng mL− 1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号