首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 64 毫秒
1.
The detection of human bone morphogenic protein-7 (BMP-7) was achieved using a sequential injection immunoassay (SIIA) system. The SIIA system is based on the binding between BMP-7 and anti-human BMP-7 (AbBMP7)–CdSe/ZnS quantum dot (QD) conjugates immobilized onto a glass disk or an optical fiber, using fluorescence detection at excitation and emission wavelengths of 470 nm and 580 nm, respectively. The AbBMP7–QD conjugates were prepared by conjugating anti-human BMP-7 antibody (AbBMP7) to hydrophilic CdSe/ZnS core/shell quantum dots (QDs). The SIIA system was fully automated using software written in the LabVIEW™ development environment. The analytical performance of the SIIA system was characterized with a number of variables such as carrier flow rate and elution buffer. Under partially optimized operating conditions, the SIIA system had a linear calibration graph at up to 10.0 ng mL−1 BMP-7 (R2 ≥ 0.975) and a sample frequency of two samples per hour. The SIIA system with an optical fiber immunosensor was used to detect and quantify BMP-7 in spiked real samples obtained from a biological process with recoveries in the range of 95–102%.  相似文献   

2.
The aim of this paper was to demonstrate a fluorescence measurement method for rapid detection of two bacterial count by using water-soluble quantum dots (QDs) as a fluorescence marker, and spectrofluorometer acted as detection apparatus, while Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) were as detection target bacteria. Highly luminescent water-soluble CdSe QDs were first prepared by using thioglycolic acid (TGA) as a ligand, and were then covalently coupled with target bacteria. The bacterial cell images were obtained using fluorescence microscopy. Our results showed that CdSe QDs prepared in water phase were highly luminescent, stable, and successfully conjugated with E. coli and S. aureus. The fluorescence method could detect 102-107 CFU/mL total count of E. coli and S. aureus in 1-2 h and the low detection limit is 102 CFU/mL. A linear relationship of the fluorescence peak intensity and log total count of E. coli and S. aureus have been established using the equation Y = 118.68X − 141.75 (r = 0.9907).  相似文献   

3.
This paper reports a facile and general method for preparing an imprinted polymer thin shell with Mn-doped ZnS quantum dots (QDs) at the surface of silica nanoparticles by stepwise precipitation polymerization to form the highly-controllable core–shell nanoparticles (MIPs@SiO2–ZnS:Mn QDs) and sensitively recognize the target 2,4-dichlorophenol (2,4-DCP). Acrylamide (AM) and ethyl glycol dimethacrylate (EGDMA) were used as the functional monomer and the cross-linker, respectively. The MIPs@SiO2–ZnS:Mn QDs had a controllable shell thickness and a high density of effective recognition sites, and the thickness of uniform core–shell 2,4-DCP-imprinted nanoparticles was controlled by the total amounts of monomers. The MIPs@SiO2–ZnS:Mn QDs with a shell thickness of 45 nm exhibited the largest quenching efficiency to 2,4-DCP by using the spectrofluorometer. After the experimental conditions were optimized, a linear relationship was obtained covering the linear range of 1.0–84 μmol L−1 with a correlation coefficient of 0.9981 and the detection limit (3σ/k) was 0.15 μmol L−1. The feasibility of the developed method was successfully evaluated through the determination of 2,4-DCP in real samples. This study provides a general strategy to fabricate highly-controllable core–shell imprinted polymer-contained QDs with highly selective recognition ability.  相似文献   

4.
Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L−1. The lineal range was between 10–5 × 103 ng L−1. RSD values in the range of 71–102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence.  相似文献   

5.
A sensitive luminescent bioassay for the simultaneous detection of Salmonella Typhimurium and Staphylococcus aureus was developed using aptamer-conjugated magnetic nanoparticles (MNPs) for both recognition and concentration elements and using upconversion nanoparticles (UCNPs) as highly sensitive dual-color labels. The bioassay system was fabricated by immobilizing aptamer 1 and aptamer 2 onto the surface of MNPs, which were employed to capture and concentrate S. Typhimurium and S. aureus. NaY0.78F4:Yb0.2,Tm0.02 UCNPs modified aptamer 1 and NaY0.28F4:Yb0.70,Er0.02 UCNPs modified aptamer 2 further were bond onto the captured bacteria surface to form sandwich-type complexes. Under optimal conditions, the correlation between the concentration of S. Typhimurium and the luminescent signal was found to be linear within the range of 101–105 cfu mL−1 (R2 = 0.9964), and the signal was in the range of 101–105 cfu mL−1 (R2 = 0.9936) for S. aureus. The limits of detection of the developed method were found to be 5 and 8 cfu mL−1 for S. Typhimurium and S. aureus, respectively. The ability of the bioassay to detect S. Typhimurium and S. aureus in real water samples was also investigated, and the results were compared to the experimental results from the plate-counting methods. Improved by the magnetic separation and concentration effect of MNPs, the high sensitivity of UCNPs, and the different emission lines of Yb/Er- and Yb/Tm-doped NaYF4 UCNPs excited by a 980 nm laser, the present method performs with both high sensitivity and selectivity for the two different types of bacteria.  相似文献   

6.
The development of a faradic impedimetric immunosensor based on electropolymerized polytyramine (Ptyr) films for the detection of S. typhimurium in milk is described for the first time. Polyclonal anti-Salmonella was cross-linked, in the presence of glutaraldehyde vapors, on Ptyr-modified gold electrodes. The dielectric behaviour of Ptyr films was evaluated with capacitance measurements, while their stability in neutral aqueous solutions was examined with impedimetric measurements. The effect of the concentration of tyramine in the forming solution on both the sensitivity and the dynamic range of the resulted immunosensors was also investigated. The alteration of the interfacial features of the electrodes due to different modification or recognition steps, was measured by faradic electrochemical impedance spectroscopy in the presence of a hexacyanoferrate(II)/(III) redox couple. At samples containing a low initial concentration of 10 cfu mL−1S. typhimurium, that actually defines the LOD of the immunosensors, signal changes of 33% and 88% were achieved after 3 and 10 h incubation, respectively. To achieve the working simplicity expected by a biosensor, immunoreaction was performed directly in cultures. This resulted in the elimination of various centrifugation and washing steps, which are used for the isolation of bacteria cells from the culture, thus making the proposed immunosensors promising candidates for on-site applications. Finally, the proposed immunosensors were successfully used for the detection of S. typhimurium in experimentally inoculated milk samples.  相似文献   

7.
Zhang F  Li C  Li X  Wang X  Wan Q  Xian Y  Jin L  Yamamoto K 《Talanta》2006,68(4):1353-1358
A reagentless amperometric uric acid biosensor based on zinc sulfide (ZnS) quantum dots (QDs) was firstly developed. It could detect uric acid without the presence of an electron mediator. The carboxyl group functionalized ZnS QDs were synthesized, and they were soluble biocompatible and conductive. ZnS QDs conjugates could provide increased enzyme binding sites, which may result in higher enzyme loading. Thus, the proposed uricase/ZnS QDs/l-cys biosensor exhibited higher amperometric response compared to the one without QDs (uricase/l-cys biosensor). In addition, there was little AA interference. It showed a linear dependence on the uric acid concentration ranging from 5.0 × 10−6 to 2.0 × 10−3 mol L−1 with a detection limit of 2.0 × 10−6 mol L−1 at 3σ.  相似文献   

8.
The discovery and development of photoelectrochemical sensors with novel principles are of great significance to realize sensitive and low-cost detection. In this paper, a new photoelectrochemial sensor based on the in situ formation of p–n junction was designed and used for the accurate determination of mercury(II) ions. Cysteine-capped ZnS quantum dots (QDs) was assembled on the surface of indium tin oxide (ITO) electrode based on the electrostatic interaction between Poly(diallyldimethylammonium chloride) (PDDA) and Cys-capped ZnS QDs. The in situ formation of HgS, a p-type semiconductor, on the surface of ZnS facilitated the charge carrier transport and promoted electron-hole separation, triggered an obviously enhanced anodic photocurrent of Cys-capped ZnS QDs. The formation of p–n junction was confirmed by P–N conductive type discriminator measurements and current–voltage (IV) curves. The photoelectrochemical method was used for the sensing of trace mercuric (II) ions with a linear concentration of 0.01 to 10.0 µM and a detection limit of 4.6 × 10−9 mol/L. It is expected that the present study can serve as a foundation to the application of p–n heterojunction to photoelectrochemical sensors and it might be easily extended to more exciting sensing systems by photoelectrochemistry.  相似文献   

9.
Wang X  Lv Y  Hou X 《Talanta》2011,84(2):382-386
The interaction between mercaptoacetic acid (MA)-capped CdTe QDs, MA-capped CdTe/ZnS QDs or glutathione (GSH)-capped CdTe QDs with As(III) was studied using fluorescence spectrometry. As (III) has a high-affinity to reduced-GSH to form As(SG)3, and the emission of the GSH-capped CdTe QDs (λem. = 612 nm) is quenched effectively. Thus, a novel fluorescence spectrometric method was developed for As (III) determination by using GSH-CdTe QDs. Under optimal conditions, the quenched fluorescence intensity (F0/F) increased linearly with the concentration of As (III) ranging from 5.0 × 10−6 to 25 × 10−5 mol L−1. The limit of detection (3σ) for As (III) was found to be 2 × 10−8 mol L−1. This method is potentially useful in visual detection of As (III) under irradiation of the ultraviolet light.  相似文献   

10.
In previous studies we have developed a simple electrokinetically-controlled lab-on-a-chip for heterogeneous immunoassay. In that method, all the sequential operations in an immunoassay, such as reagent loading and washing, were performed automatically by electrokinetically controlling the flow in an H-shaped microchannel. Here, we demonstrated further development of a high-throughput immunoassay microfluidic chip, and the application of the new immunoassay microfluidic chip in assaying human serum. The microfluidic immunoassay analyzed ten samples in parallel in 22 min. Bacterial antibodies in samples were captured by antigens pre-patterned on the bottom wall of a microchannel and then bound with TRITC-labeled detection antibodies to generate fluorescent signals. With optimized surface concentration of antigen, the assay detected Escherichia coli O157:H7 antibody and Helicobacter pylori antibody from buffer solutions in concentration ranges of 0.02-10 μg mL−1 and 0.1-50 μg mL−1, respectively. Human sera that were E. coli-positive or H. pylori-positive were accurately distinguished from respective negative controls. Moreover, the two antibodies, anti-E. coli and anti- H. pylori antibodies, could be simultaneously detected from human serum. This electrokinetically-controlled immunoassay shows an excellent potential for efficiently detecting multiple pathogenic infections in clinical environments.  相似文献   

11.
This work presented a novel method for specific detection of sulfate-reducing bacteria (SRB) based on the photocatalytic property of ZnS nanoparticles. ZnS semiconductor nanoparticles were synthesized by taking advantage of the characteristic bacterial metabolite, sulfide, and then ZnS nanomaterials were used as photocatalyst for methylene blue (MB) photodegradation. As the amount of ZnS photocatalyst synthesized from microbe metabolized sulfide was affected by initial bacterial concentration before cultivation, the photodegradation ratio of MB was highly related with initial SRB concentration. Under the optimized conditions, a linear relationship between the MB photodegradation ratio and the logarithm of SRB concentration was observed in the range of 1.0 × 103–1.0 × 108 cfu mL−1. Besides, this proposed method showed excellent specificity for SRB detection. To the best of our knowledge, this is the first example of using the photocatalytic property of microbial synthesized ZnS for bacterial detection.  相似文献   

12.
We report a turn-on phosphorescence probe for detection of histidine based on Co2+-adsorbed N-acetyl-l-cysteine (NAC) capped Mn: ZnS quantum dots (QDs) which is directly synthesized by the hydrothermal method. The phosphorescence of NAC-Mn: ZnS QDs is effectively quenched by Co2+ attributing to the adsorption of Co2+ onto the surface of QDs with a concomitant in suppressing the recombination process of hole and electron of QDs. The phosphorescence of Co2+-adsorbed NAC-Mn: ZnS QDs can be recovered by binding of Co2+ with histidine. The quenching and regeneration of the phosphorescence of NAC-Mn: ZnS QDs have been studied in detail. The as-prepared QDs-based probe is applied to determine histidine with a linear range of 1.25–30 μM and a detection limit of 0.74 μM. The relative standard deviation for eleven repeat detections of 20 μM histidine is 0.65%. Co2+-adsorbed NAC-Mn: ZnS QDs show high sensitivity and good selectivity to histidine over other amino acids, metal ions and co-existing substances. The proposed QDs probe has been successfully applied to determination of histidine in human urine samples with good recoveries of 98.5–103%.  相似文献   

13.
Present work demonstrates the utilization of surface modified polycarbonate (PC) membrane as solid phase and antibody conjugated CdSe/ZnS quantum dots (QDs) as fluorescent label for the sensitive and selective detection of Salmonella typhi (S. typhi) in water in a period of 2.5 h. PC membrane was surface modified with glycine and activated by EDC/NHS for immobilization of S. typhi specific IgG. Antibody immobilized porous PC membrane was incubated with bacteria contaminated water for immunocapturing of S. typhi. Antibody conjugated QDs were also prepared by using carbodiimide chemistry. Both modified PC membrane and quantum dots were characterized by using various modern analytical tools. It was estimated that 1.95 molecules of QDs were successfully bio-conjugated per unit of IgG. PC membrane with captured bacteria was incubated with prepared IgG conjugated QDs for the formation of sandwich complex. Analysis of the regions of interest (ROI) in fluorescent micrographs showed that newly developed method based on PC and fluorescent QDs has 100 times higher detection sensitivity (100 cells/mL) as compared with detection using conventional dye (FITC) based methods.  相似文献   

14.
Luminescent surface-modified CdSe semiconductor quantum dots (QDs), with nanoparticle (NP) size distribution in the order of 2-7 nm, have been synthesized for optical determination of cyanide ions. The nanoparticles have been functionalised with tert-butyl-N-(2-mercaptoethyl)-carbamate (BMC) groups and exhibit a strong fluorescent emission at about 580 nm with rather long fluorescence lifetimes (several hundred nanoseconds) in aerated methanolic solution. The observed luminescence emitted by the synthesized nanocrystals was tremendously increased by photo-activation under sunlight exposure. The functionalised QDs turned out to exhibit excellent long-term stability when stored in the dark (no significant changes in QDs luminescence emission intensity was observed even after two months from synthesis). The functionalisation of the NPs with carbamate ligand allowed a highly sensitive determination of free cyanide via analyte-induced changes in the photoluminescence (fluorescence quenching of intensity at 580 nm and lifetime changes) of the modified quantum dots (excited at 400 nm). A detection limit of 1.1 × 10−7 M (2.9 μg l−1) of cyanide ions was obtained, while the interfering effect of other inorganic anions (including NO3, Cl or SCN) was negligible even at 200-fold level concentrations in excess of cyanide.  相似文献   

15.
Practical applications of chemical and biological detections through surface-enhanced Raman scattering (SERS) require high reproducibility, sensitivity, and efficiency, along with low-cost, straightforward fabrication. In this work, we integrated a poly-(dimethylsiloxane) (PDMS) chip with quasi-3D gold plasmonic nanostructure arrays (Q3D-PNAs), which serve as SERS-active substrates, into an optofluidic microsystem for online sensitive and reproducible SERS detections. The Q3D-PNA PDMS chip was fabricated through soft lithography to ensure both precision and low-cost fabrication. The optimal dimension of the Q3D-PNA in PDMS was designed using finite-difference time-domain (FDTD) electromagnetic simulations with a simulated enhancement factor (EF) of 1.6 × 106. The real-time monitoring capability of the SERS-based optofluidic microsystem was investigated by kinetic on/off experiments through alternatively flowing Rhodamine 6G (R6G) and ethanol in the microfluidic channel. A switch-off time of ∼2 min at a flow rate of 0.3 mL min−1 was demonstrated. When applied to the detection of low concentration malathion, the SERS-based optofluidic microsystem with Q3D-PNAs showed high reproducibility, significantly improved efficiency and higher detection sensitivity via increasing the flow rate. The optofluidic microsystem presented in this paper offers a simple and low-cost approach for online, label-free chemical and biological analysis and sensing with high sensitivity, reproducibility, efficiency, and molecular specificity.  相似文献   

16.
Duan J  Jiang X  Ni S  Yang M  Zhan J 《Talanta》2011,85(4):1738-1743
This paper described an investigation of a novel eco-friendly fluorescence sensor for Hg2+ ions based on N-acetyl-l-cysteine (NAC)-capped ZnS quantum dots (QDs) in aqueous solution. By using safe and low-cost materials, ZnS QDs modified by NAC were easily synthesized in aqueous medium via a one-step method. The quantitative detection of Hg2+ ions was developed based on fluorescence quenching of ZnS QDs with high sensitivity and selectivity. Under optimal conditions, its response was linearly proportional to the concentration of Hg2+ ions in a range from 0 to 2.4 × 10−6 mol L−1 with a detection limit of 5.0 × 10−9 mol L−1. Most of common physiologically relevant cations and anions did not interfere with the detection of Hg2+. The proposed method was applied to the trace determination of Hg2+ ions in water samples. The possible quenching mechanism was also examined by fluorescence and UV-vis absorption spectra.  相似文献   

17.
Quantitation of trace levels of domoic acid (DA) in seawater samples usually requires labour-intensive protocols involving chemical derivatization with 9-fluorenylmethylchloroformate and liquid chromatography with fluorescence detection (FMOC–LC–FLD). Procedures based on LC–MS have been published, but time-consuming and costly solid-phase extraction pre-concentration steps are required to achieve suitable detection limits. This paper describes an alternative, simple and inexpensive LC method with ultraviolet detection (LC–UVD) for the routine analysis of trace levels of DA in seawater without the use of sample pre-concentration or derivatization steps. Qualitative confirmation of DA identity in dubious samples can be achieved by mass spectrometry (LC–MS) using the same chromatographic conditions. Addition of an ion-pairing/acidifying agent (0.15% trifluoroacetic acid) to sample extracts and the use of a gradient elution permitted the direct analysis of large sample volumes (100 μl), resulting in both high selectivity and sensitivity (limit of detection = 42 pg ml−1 by LC–UVD and 15 pg ml−1 by LC–MS). Same-day precision varied between 0.4 and 5%, depending on the detection method and DA concentration. Mean recoveries of spiked DA in seawater by LC–UVD were 98.8% at 0.1–10 ng ml−1 and 99.8% at 50–1000 ng ml−1. LC–UVD exhibited strong correlation with FMOC–LC–FLD during inter-laboratory analysis of Pseudo-nitzschia multiseries cultures containing 60–2000 ng DA ml−1 (r2 > 0.99), but more variable results were obtained by LC–MS (r2 = 0.85). This new technique was used to confirm the presence of trace DA levels in low-toxicity Pseudo-nitzschia spp. isolates (0.2–1.6 ng ml−1) and in whole-water field samples (0.3–5.8 ng ml−1), even in the absence of detectable Pseudo-nitzschia spp. cells in the water column.  相似文献   

18.
Wang J  Pumera M 《Talanta》2006,69(4):984-987
This paper reports on a microfluidic device for the flow-injection/electrochemistry analysis of nitroaromatic explosive. The response is very fast (150 assays/h), highly sensitive (detection limit 7.0 μg L−1), reproducible and stable (R.S.D. = 2.0%; n = 30) and linear (over 20-100 μg L−1 range). Relevant experimental parameters have been optimized. The new microsystem offers great promise for on-site monitoring of TNT, with significant advantages of speed/warning, sample size, efficiency and cost. Most favorable S/N characteristics were obtained at the Hg/Au-amalgam end-channel detector.  相似文献   

19.
A novel dual-function material was synthesized by anchoring a molecularly imprinted polymer (MIP) layer on CdTe/ZnS quantum dots (QDs) using a sol–gel with surface imprinting. The material exhibited highly selective and sensitive determination of ractopamine (RAC) through spectrofluorometry and solid-phase extraction (SPE) coupled with high performance liquid chromatography (HPLC). A series of adsorption experiments revealed that the material showed high selectivity, good adsorption capacity and a fast mass transfer rate. Fluorescence from the MIP-coated QDs was more strongly quenched by RAC than that of the non-imprinted polymer, which indicated that the MIP-coated QDs acted as a fluorescence sensing material could recognize RAC. In addition, the MIP-coated QDs as a sorbent was also shown to be promising for SPE coupled with HPLC for the determination of trace RAC in feeding stuffs and pork samples. Under optimal conditions, the spectrofluorometry and SPE-HPLC methods using the MIP-coated QDs had linear ranges of 5.00 × 10−10–3.55 × 10−7 and 1.50 × 10−10–8.90 × 10−8 mol L−1, respectively, with limits of detection of 1.47 × 10−10 and 8.30 × 10−11 mol L−1, the relative standard deviations for six repeat experiments of RAC (2.90 × 10−9 mol L−1) were below 2.83% and 7.11%.  相似文献   

20.
In this work, a new, label-free, homogeneous, highly sensitive, and selective fluorescent biosensor for DNA detection is developed by using rolling-circle amplification (RCA) based single-color quantum dots–ruthenium complex (QDs–Ru) assembling dyads. This strategy includes three steps: (1) the target DNA initiates RCA reaction and generates linear RCA products; (2) the complementary DNA hybridizes with the RCA products to form long double-strand DNA (dsDNA); (3) [Ru(phen)2(dppx)]2+ (dppx = 7,8-dimethyldipyrido [3,2-a:2′,3′-c] phenanthroline) intercalates into the long dsDNA with strong fluorescence emission. Due to its strong binding propensity with the long dsDNA, [Ru(phen)2(dppx)]2+ is removed from the surface of the QDs, resulting in restoring the fluorescence of the QDs, which has been quenched by [Ru(phen)2(dppx)]2+ through a photoinduced electron transfer process and is overlaid with the fluorescence of dsDNA bonded Ru(II) polypyridyl complex (Ru-dsDNA). Thus, high fluorescence intensity is observed, and is related to the concentration of target. This sensor exhibits not only high sensitivity for hepatitis B virus (HBV) ssDNA with a low detection limit (0.5 pM), but also excellent selectivity in the complex matrix. Moreover, this strategy applies QDs–Ru assembling dyads to the detection of single-strand DNA (ssDNA) without any functionalization and separation techniques.  相似文献   