首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
Mesoporous TiO2 nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO2 powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO2 fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L−1) and wide linearity (5–5000 ng L−1) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.  相似文献   

2.
An approach to the synthesis of hydroxyl-terminated polymethylphenylsiloxane (PMPS-OH) was proposed and the synthesized PMPS-OH was successfully applied as a precursor to prepare a novel coating for solid-phase microextraction (SPME) via the sol-gel process. The thickness and length of the prepared coating was 70 μm and 1.5 cm, respectively. The extraction efficiency of the PMPS-coated fiber for selected pesticides was higher than that of commercial fibers including 100 μm polydimethylsiloxane (PDMS), 85 μm polyacrylate (PA) and 65 μm polydimethylsiloxane/divinylbenzene (PDMS/DVB). The influence of the extraction process, extraction temperature, extraction time, stirring rate, ionic strength, GC inlet conditions, desorption temperature and time for PMPS-coated fiber application was studied and optimized. Several experiments were carried out to evaluate the analytical characteristics of the proposed SPME-GC-ECD method under optimized conditions. The linearity was from 0.5 to 100 ng g−1 for p,p′-DDE, p,p′-DDD and bifenthrin, and from 2 to 100 ng g−1 for o,p′-DDT, p,p′-DDT, fenpropathrin, beta-cyfluthrin and cyhalothrin. The detection limits of these pesticides were between 0.13 and 1.45 ng g−1. The recovery of the pesticides spiked in various vegetables at 4 ng g−1 ranged from 42.9% to 105.3%, and the relative standard deviations were less than 16.2%.  相似文献   

3.
Metal-organic frameworks (MOFs) have received great attention as novel sorbents due to their fascinating structures and intriguing potential applications in various fields. In this work, a MIL-101(Cr)-coated solid-phase microextraction (SPME) fiber was fabricated by a simple direct coating method and applied to the determination of volatile compounds (BTEX, benzene, toluene, ethylbenzene, m-xylene and o-xylene) and semi-volatile compounds (PAHs, polycyclic aromatic hydrocarbons) from water samples. The extraction and desorption conditions of headspace SPME (HS-SPME) were optimized. Under the optimized conditions, the established methods exhibited excellent extraction performance. Good precision (<7.7%) and low detection limits (0.32–1.7 ng L−1 and 0.12–2.1 ng L−1 for BTEX and PAHs, respectively) were achieved. In addition, the MIL-101(Cr)-coated fiber possessed good thermal stability, and the fiber can be reused over 150 times. The fiber was successfully applied to the analysis of BTEX and PAHs in river water by coupling with gas chromatography–mass spectrometry (GC–MS). The analytes at low concentrations (1.7 and 10 ng L−1) were detected, and the recoveries obtained with the spiked river water samples were in the range of 80.0–113% and 84.8–106% for BTEX and PAHs, respectively, which demonstrated the applicability of the self-made fiber.  相似文献   

4.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

5.
The monodisperse microporous carbon nanospheres (MMCNSs) were applied in solid phase microextraction for the first time. The MMCNSs-fiber was prepared by sol–gel technique and good repeatability and reproducibility were obtained, due to the excellent monodispersity of the MMCNSs. The sol–gel-MMCNSs fiber exhibited superior extraction ability for polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs), compared with the commercial polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber and the fiber prepared with its precursor, the monodisperse microporous polystyrene nanospheres (MMPNSs). Moreover, the fiber has good thermostability and strong acid/base durability. The sol–gel-MMCNSs fiber was then employed to detect PAHs and OCPs in aqueous samples by combining with gas chromatography–mass spectrometer (GC–MS). Under the optimized conditions, the detection limits of the proposed method ranged from 0.10 to 5.5 ng L−1. Furthermore, the method was successfully utilized for the analysis of PAHs and OCPs in real samples, with satisfactory recoveries in the range of 81.0–120% for the Pearl River water samples and 72.8–118% for the coking wastewater samples.  相似文献   

6.
Periodic mesoporous organosilica based on alkylimidazolium ionic liquid (PMO-IL) was prepared and used as a highly porous fiber coating material for solid-phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless steel wire for fabrication of the SPME fiber. The fiber was evaluated for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions in combination with gas chromatography–mass spectrometry (GC–MS). A one at-the-time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. In optimum conditions, the repeatability for one fiber (n = 3), expressed as relative standard deviation (R.S.D.%), was between 4.3% and 9.7% for the test compounds. The detection limits for the studied compounds were between 4 and 9 pg mL−1. The developed method offers the advantage of being simple to use, with shorter analysis time, lower cost of equipment, thermal stability of fiber and high relative recovery in comparison to conventional methods of analysis.  相似文献   

7.
A superior solid-phase microextraction (SPME) fiber-coating material, IRMOF-3@ILs/PDMS, was prepared by the in situ growth of IRMOF-3 onto stainless-steel wires and protection with ionic liquids (ILs) and polydimethylsiloxane (PDMS). The ILs can efficiently prevent the substantial cracking of IRMOF-3 caused by moisture, and a thin PDMS film can protect the IRMOF-3@ILs material to achieve a much better extraction efficiency as well as excellent resistance to high temperature and high humidity. This IRMOF-3@ILs/PDMS coating possessed a porous structure, a rough surface and an increased lifespan (by at least 100 times) compared with that of IRMOF-3. The coating was evaluated by analyzing four polycyclic aromatic hydrocarbons (PAHs) in water, and good precision (<7.7%), low detection limits (12.0–15.4 ng L−1), and wide linearity (50–20,000 ng L−1) were achieved under the optimized conditions. The fiber was successfully applied to the sensitive analysis of PAHs in rainwater by coupling it with gas chromatography–mass spectrometry (GC–MS).  相似文献   

8.
A solid-phase microextraction (SPME) method for the determination of five amphetamine type stimulants (ATSs) in water and urine samples is presented. Analytes were simultaneously derivatized with iso-butyl chloroformate (iBCF) in the aqueous sample while being extracted, improving in this way the extractability of ATSs and permitting their determination by gas chromatography–mass spectrometry (GC–MS). The SPME procedure was carefully optimized in order to achieve adequate limits of detection (LODs) for environmental concentrations. Hence, different operational parameters were considered: type of SPME coating, ionic strength, basic catalyzer and derivatizing agent amount, extraction time and temperature. The final SPME procedure consists into the extraction of 100 mL of sample containing 2 g of dipotassium monohydrogen phosphate trihydrate and 100 μL of iBCF (1:1 in acetonitrile), for 40 min at 60 °C with a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. Under these conditions, LODs in wastewater ranged from 0.4 to 2 ng L−1, relative recoveries in the 84–114% range and relative standard deviations (RSD) lower than 15% were obtained. The application of the method to wastewater and river water samples showed the ecstasy ATS, 3,4-methylenedioxymethamphetamine (MDMA), as the most frequently detected, followed by methamphetamine, in concentrations around 20 ng L−1. Finally, the method was downscaled and also validated with urine samples, proving its good performance with this matrix too: RSD < 11%, recoveries in the 98–110% range and LODs lower than 0.1 μg L−1.  相似文献   

9.
Natalia Campillo 《Talanta》2007,71(3):1417-1423
A direct immersion solid-phase microextraction (SPME) procedure was used in combination with capillary gas chromatography with atomic emission detection (GC-AED) for the determination of 10 pesticides (organochlorines, organophosphorus compounds and pyrethrins) in herbal and tea infusions. Ionic strength, sample dilution and time and temperature of the absorption and desorption stages were some of the parameters investigated in order to select the optimum conditions for SPME with a 100 μm PDMS fiber-coating. Element-specific detection and quantification was carried out by monitoring the chlorine (479 nm) and bromine (478 nm) emission lines, which provided nearly specific chromatograms. Calibration was carried out by using a spiked sample infusion. The detection limits varied between 11.9 ng ml−1 for deltamethrin and 0.03 ng ml−1 for p,p′-DDE and p,p′-DDD. The recoveries ranged from 73.5% for deltamethrin to 108.3% for p,p′-DDT in a spiked white tea infusion. Two of the eight samples analyzed contained low levels of some the pesticides considered.  相似文献   

10.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

11.
A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography–selected ion monitoring–mass spectrometry (GC–SIM–MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80 °C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L−1, respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n = 3). The linear range was 0.1–10 μg L−1 with r ≥ 0.96 and the fiber-to-fiber reproducibility showed RSD ≤ 18.6% (n = 5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME.  相似文献   

12.
In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p′-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p′-DDT and its chiral degradation product, o,p′-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC × GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p′-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p′-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC–TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p′-isomers from the complex sample chromatogram, 1D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p′-DDT and o,p′-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by 1D GC–TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC × GC–TOFMS using the same enantioselective column, this time as the first dimension of separation.  相似文献   

13.
A new method for the determination of aflatoxins B1, B2, G1, and G2 (AFB1, AFB2, AFG1, AFG2) in cereal flours based on solid-phase microextraction (SPME) coupled with high performance liquid chromatography with post-column photochemical derivatization and fluorescence detection (SPME–HPLC–PD–FD) has been developed. Aflatoxins were extracted from cereal flour samples by a methanol:phosphate buffer (pH 5.8, I = 0.1) (80:20, v/v) solution, followed by a SPME step. Different SPME and HPLC–PD–FD parameters (fiber polarity, temperature, pH, ionic strength, adsorption and desorption time, mobile phase) have been investigated and optimized. This method, which was assessed for the analysis of different cereal flours, showed interesting results in terms of LOD (from 0.035 to 0.2 ng g−1), LOQ (from 0.1 to 0.63 ng g−1, respectively), within and inter-day repeatability (2.27% and 5.38%, respectively) linear ranges (up to 20 ng g−1 for AFB1 and AFG1 and 6 ng g−1 for AFB2 and AFG2), and total raw extraction efficiency (in the range 55–59% at concentrations in the range 0.3–1 ng g−1 and 49–52% at concentrations in the range 1–10 ng g−1). The results were also compared with the purification step carried out by conventional immunoaffinity columns.  相似文献   

14.
The organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control in certain areas of South Africa. The strict Stockholm Convention on Persistent Organic Pollutants (POPs) allows spraying on the inside of traditional dwellings with DDT. In rural villages contaminated dust presents an additional pathway for exposure to DDT. We present a new method for the determination of DDT in indoor air where separate vapour and particulate samples are collected in a single step with a denuder configuration of a multi-channel open tubular silicone rubber (polydimethylsiloxane (PDMS)) trap combined with a micro quartz fibre filter. The multi-channel PDMS trap section of the denuder concentrates vapour phase insecticide whereas particle associated insecticide is transferred downstream where it is collected on a micro-fibre filter followed by a second multi-channel PDMS trap to capture the blow-off from the filter. The multi-channel PDMS trap and filter combination are designed to fit a commercial thermal desorber for direct introduction of samples into a GC–MS. The technique is solvent-free. Analyte extraction and sample clean-up is not required. Two fractions, vapour phase and particulate phase p,p′-DDT, o,p′-DDT; p,p′-DDD, o,p′-DDD; p,p′-DDE and o,p′-DDE in 4 L contaminated indoor air, were each quantitatively analysed by GC–MS using isotopically labelled ring substituted 13C12p,p′-DDT as an internal standard. Limits of detection were 0.07–0.35 ng m−3 for p,p′-DDT, o,p′-DDT, p,p′-DDD, o,p′-DDD, p,p′-DDE and o,p′-DDE. Ratios of airborne p,p′-DDD/p,p′-DDT and of o,p′-DDT/p,p′-DDT are unusual and do not match the ideal certified ingredient composition required of commercial DDT. Results suggest that the DDT products used for indoor residual spraying (IRS) prior to, and during 2007, may have been compromised with regards to insecticidal efficacy, demonstrating the power of this new environmental forensics tool.  相似文献   

15.
A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)–liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME–LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30 s. And injection was completed in 20 s. About 10–20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1 mL min−1 for 2 min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL−1 range. The linear ranges were from 0.1 to 100 ng mL−1. The new SPME–LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.  相似文献   

16.
A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography–mass spectrometry detection (GC–MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol–gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature, extraction time, and desorption conditions were investigated and optimized. The developed method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. Under the optimized conditions, the detection limit of the method was 5 ng L−1 using selected ion monitoring (SIM) mode. The inter-day and intra-day precisions of the developed method under optimized conditions were below 10%, and the method shows linearity in the range of 20 ng L−1 to 500 μg L−1with the correlation coefficient of >0.99. The optimized method was applied to the sampling of phenol from some biologics production areas. The compared results obtained using current and standard methods were shown to be satisfactory.  相似文献   

17.
A new concept of liquid–liquid–liquid microextraction (LLLME) was introduced based on applying two immiscible organic solvents in lumen and wall pores of hollow fiber (HF). With this methodology, analytes of interest can be extracted from aqueous sample, into a thin layer of organic solvent (dodecane) sustained in the pores of a porous hollow fiber, and further into a μL volume of organic acceptor (acetonitrile or methanol) located inside the lumen of the hollow fiber. Some chlorophenols (CPs) were selected as model compounds for developing and evaluating of the method performance. The analysis was performed by gas chromatography–electron capture detection (GC–ECD) without derivatization. The factors affecting the HF-LLLME of target compounds were investigated and the optimal extraction conditions were established. Under the optimum conditions, preconcentration factors in a range of 208–895 were obtained. The performance of the proposed method was studied in terms of linear dynamic ranges (LDRs from 0.02 to 100 ng mL−1), linearity (R2 ≥ 0.995), precision (RSD % ≤ 8.1) and limits of detection (LODs in the range of 0.006–0.2 ng mL−1). In addition to preconcentration, HF-LLLME also served as a technique for sample clean-up.  相似文献   

18.
A procedure based on QuEChERS extraction and a simultaneous liquid–liquid partition clean-up was developed. The procedure involved extraction of hydrated soil samples using acetonitrile and clean-up by liquid–liquid partition into n-hexane. The hexane extracts produced were clean and suitable for determination using gas chromatography–tandem mass spectrometry (GC–MS/MS). The method was validated by analysis of soil samples, spiked at five levels between 1 and 200 μg kg−1. The recovery values were generally between 70 and 100% and the relative standard deviation values (%RSDs) were at or below 20%. The procedure was validated for determination of 19 organochlorine (OC) pesticides. These were hexachlorobenzene (HCB), α-HCH, β-HCH, γ-HCH, heptachlor, heptachlor epoxide (trans), aldrin, dieldrin, chlordane (trans), chlordane (cis), oxychlordane, α-endosulfan, β-endosulfan, endosulfan sulfate, endrin, p,p′-DDT, o,p′-DDT, p,p′-DDD and p,p′-DDE. The method achieved low limits of detection (LOD; typically 0.3 μg kg−1) and low limits of quantification (LOQ; typically 1.0 μg kg−1). The method performance was also assessed using five fortified soil samples with different physico-chemical properties and the method performance was consistent for the different types of soil samples. The proposed method was compared with an established procedure based on Soxtec extraction. This comparison was carried out using six soil samples collected from regions of Pakistan with a history of intensive pesticide use. The results of this comparison showed that the two procedures produced results with good agreement. The proposed method produced cleaner extracts and therefore led to lower limits of quantification. The proposed method was less time consuming and safer to use. The six samples tested during this comparison showed that soils from cotton growing regions contained a number of persistent OC residues at relatively low levels (<10 μg kg−1). These residues were α-HCH, γ-HCH, heptachlor, chlordane (trans), p,p′-DDT, o,p′-DDT, p,p′-DDD, p,p′-DDE, β-endosulfan and endosulfan sulfate.  相似文献   

19.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

20.
A high-throughput solid-phase microextraction (SPME) on 96-well plate together with gas chromatography–mass spectrometry (GC–MS) was developed for the determination of some selected pesticides in cucumber samples. Pieces with the length of 1.0 cm of silicon tubing were precisely prepared and then coated on the end part of stainless steel wires. The prepared fibers were positioned in a home-made polytetrafluoroethylene (PTFE)-based constructed ninety-six holes block to have the possibility of simultaneous immersion of the SPME fibers into the center of individual wells. Pesticides such as diazinon, penconazol, tebuconazol, bitertanol, malathion, phosalone and chlorpyrifos-methyl were selected for their highly application in cucumber field. The performances of the SPME fibers, such as intra and inter-fibers reproducibility, were evaluated and the results showed a good similarity in extraction yields. A volume of 1 mL of the aquatic supernatant of the cucumber samples was transferred into the 96-well plate and the array of SPME fibers was applied for the extraction of the selected pesticides. The important parameters influencing the whole extraction process including, organic solvent percent, salt addition, dilution factor, stirring rate and extraction time were optimized. The inter- and intra-day RSD% were found to be less than 15.4%. Limits of detection (LOD) and limits of quantification (LOQ) were below 60 and 180 μg kg−1, respectively. The coefficient of determination was satisfactory (r2 > 0.99) for all the studied analytes. The developed method was successfully applied to the monitoring of several samples gathered from local markets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号