首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The simultaneous separation and determination of arsenite As(III), arsenate As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) in rice samples have been carried out in one single anion‐exchange column run by high‐performance liquid chromatography with inductively coupled plasma mass spectrometry. To estimate the effect of variables on arsenic (As) speciation, the chromatographic conditions including type of competing anion, ionic strength, pH of elution buffer, and flow rate of mobile phase have been investigated by a univariate approach. Under the optimum chromatographic conditions, baseline separation of six As species has been achieved within 10 min by gradient elution program using 4 mM NH4HCO3 at pH 8.6 as mobile phase A and 4 mM NH4HCO3, 40 mM NH4NO3 at pH 8.6 as mobile phase B. The method detection limits for As(III), As(V), MMA, DMA, AsB, and AsC were 0.4, 0.9, 0.2, 0.4, 0.5, and 0.3 μg/kg, respectively. The proposed method has been applied to separation and quantification of As species in real rice samples collected from Hunan Province, China. The main As species detected in all samples were As(III), As(V) and DMA, with inorganic As accounting for over 80% of total As in these samples.  相似文献   

2.
Five arsenic species, trimethylarsine oxide, dimethylarsenic acid, monomethylarsonic acid, arsenobetaine and sodium arsenite, in urine were analysed by inductively coupled plasma mass spectrometry with ion chromatography (IC ICP MS). Since the toxicities of different arsenic compounds are different, speciation of arsenic compounds is very important in the investigation of metabolisms. In this paper, we applied ion chromatography (IC) as a separation device and inductively coupled plasma mass spectrometry (ICP MS) as a detection device. For separation of the five arsenic compounds, an anion-exchange column and, as mobile phase, tartaric acid were used. The eluent from the IC column was introduced directly into the nebulizer of the ICP MS and analysed at 75 amu. Detection limits were from 4 to 9 pg as arsenic.  相似文献   

3.
Anion-exchange chromatography with inductively coupled plasma mass spectrometry (ICP-MS) is often used for the speciation of arsenic (As). In this work, either He or H2 was introduced to the octopole collision/reaction cell to eliminate chloride (Cl) interferences during As speciation by ICP-MS. Polyatomic species, 40Ar35Cl and 38Ar37Cl, which are formed in high chloride matrices interfere with the ICP-MS detection of 75As. These interferences were reduced or eliminated by introducing He or H2 to the collision/reaction cell, with some loss in sensitivity when compared to the standard mode (no gas). For example, the sensitivity of As(V) was 30.4 and 17.7% of that observed in standard mode when introducing He and H2, respectively. Chloride interference was completely eliminated using a flow rate of 3.0 mL min− 1 with H2 as a reaction gas with detection limits in the range of 0.3-0.6 μg L− 1. The developed method was applied to determination of arsenic species in waters containing high concentrations of chloride by following a simple procedure and without modification of the ICP-MS instrument.  相似文献   

4.
Inductively coupled plasma mass spectrometry (ICP-MS) and electrospray ionization mass spectrometry (ESI-MS) were used as complementary techniques to provide element and molecular information for aminocarboxylic lead species including [Pb(NTA)]1−, [Pb(HEDTA)]1−, [Pb(EDTA)]2− and [Pb(DTPA)]3−. ESI-MS was used to initially confirm the formation of lead aminocarboxylic complexes in solution and subsequently anion-change chromatography coupled with ICP-MS was used to speciate these complexes using a mobile phase containing 30 mM NH4H2PO4 at pH of 8.0. However, [Pb(NTA)]1− was not observed during chromatographic separation due to its poor stability. The species [Pb(HEDTA)]1−, [Pb(EDTA)]2− and [Pb(DTPA)]3− were separated within 15 min with reasonable resolution and detection limits ranging from 0.05 to 0.2 μg L−1 with simple direct injection of sample. The proposed method was used to speciate aminocarboxylic lead complexes in soil solution.  相似文献   

5.
A method based on ion chromatography (IC) and inductively coupled plasma MS (ICP-MS) was developed for the speciation of arsenic in water and soil extracts. An anion-exchange column (G3154A/101) was used to separate As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) with excellent resolution. Various ammonium salts, including NH4H2PO4, (NH4)2HPO4, (NH4)2CO3, and NH4HCO3, were examined as eluents to reduce matrix interference from chloride and to solve clogging problems. The best arsenic speciation was obtained within 9 min with excellent resolution and without interference from high chloride concentrations using an eluent containing 7.5 mM (NH4)2HPO4 at pH 7.9. The detection limits for the target arsenic species ranged from 0.1 to 0.4 microg/L with direct injection of sample without matrix elimination. The proposed method was effectively demonstrated by determining arsenic species in contaminated waters and soils of Bangladesh.  相似文献   

6.
A microwave-assisted enzymatic extraction (MAEE) method was developed for the simultaneous extraction of arsenic (As) and selenium (Se) species in fish tissues. The extraction efficiency of total As and Se and the stability of As and Se species were evaluated by analyzing DOLT-3 (dogfish liver). Enzymatic extraction using pronase E/lipase mixture assisted by microwave energy was found to give satisfactory extraction recoveries for As and Se without promoting interspecies conversion. The optimum extraction conditions were found to be 0.2 g of sample, 20 mg pronase E and 5 mg lipase in 10 mL of 50 mM phosphate buffer, pH 7.25 at 37 °C. The total extraction time was 30 min. The speciation analysis was performed by ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS). The accuracy of the developed extraction procedure was verified by analyzing two reference materials, DOLT-3 and BCR-627. The extraction recoveries in those reference materials ranged between 82 and 94% for As and 57 and 97% for Se. The accuracy of arsenic species measurement was tested by the analysis of BCR 627. The proposed method was applied to determine As and Se species in fish tissues purchased from a local fish market. Arsenobetaine (AsB) and selenomethionine (SeMet) were the major species detected in fish tissues. In the analyzed fish extracts, the sum of As species detected was in good agreement with the total As extracted. However, for Se, the sum of its species was lower than the total Se extracted, revealing the presence of Se-containing peptides or proteins.  相似文献   

7.
A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice.  相似文献   

8.
微波辅助萃取-液质联用技术测底泥砷、硒的化学形态   总被引:3,自引:0,他引:3  
建立了用反相离子对色谱和电感耦合等离子体质谱的联用技术同时测定As(Ⅲ)、 As(Ⅴ)、 MMA、 DMA、 Se(Ⅳ)、 Se(Ⅵ)、 SeMet和SeCys的砷、硒化学形态分析方法. 分别从流动相pH值、离子对试剂的浓度、甲醇量和流速4个方面进行了分离测定条件的优化. 利用碰撞池技术(CCT)较好地解决了^40Ar^35Cl^+复合离子对^75As的干扰, 并使^80Se的测定成为可能, 有效地提高了灵敏度. 将该方法应用于上海市苏州河底泥样品的微波辅助萃取液的形态分析中, 砷和硒的检出限分别达到0.4~1.3 和0.5~1.9 μg/L.  相似文献   

9.
In this paper, carbon nanofibers (CNFs) as a novel solid phase extraction sorbent were developed for speciation preconcentration and separation of inorganic arsenic species As(III) and As(V) prior to determination by inductively coupled plasma mass spectrometry (ICP-MS). It was found that during all the steps of the separation, As(III) was selectively sorbed on the microcolumn packed with CNFs within a pH range of 1.0-3.0 in the presence of ammonium pyrroinedithiocarbamate (APDC), while As(V) was passed through the microcolumn without the retention. Various experimental parameters affecting the separation and determination of As(III) and As(V) have been investigated in detail. Under the optimized conditions, the detection limits of this method for As(III) were 0.0045 ng mL−1 with an enrichment factor of 33 and 0.24 ng mL−1 for As(V), and the relative standard deviations for As(III) and As(V) were 2.6% and 1.9% (n = 9, c = 1.0 ng mL−1), respectively. In order to verify the accuracy of the method, a certified reference of water sample was analyzed, and the results obtained were in good agreement with the certified values. The proposed method was applied for the analysis of inorganic arsenic species in groundwater and lake water with the recovery of 92-106%.  相似文献   

10.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

11.
A new analytical method was developed to determine the bioavailable arsenic species (arsenite, arsenate, monomethylarsonic acid, and dimethylarsonic acid) in soil samples using high‐performance liquid chromatography with inductively coupled plasma mass spectrometry. Bioavailable arsenic was extracted with ammonium phosphate buffer by a simplified one‐step solvent extraction procedure. To estimate the effect of variables on arsenic extraction, a two‐level Plackett–Burman factorial design was conducted to screen the significant factors that were further investigated by a separate univariate approach. The optimum conditions were confirmed by compromising the stability of arsenic species and the extraction efficiency. The concentration of arsenic species was determined in method blank and soil‐certified reference materials both spiked with standard solutions of arsenic species. All the target arsenic species were stable during the whole extraction procedure. Furthermore, the proposed method was applied to release bioavailable arsenic from contaminated soil samples, showing that the major arsenic species in soil samples were inorganic arsenic: arsenite and arsenate, of which the latter was dominant.  相似文献   

12.
A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min?1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L?1, 14.1 ng L?1 and 6.2 ng L?1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.  相似文献   

13.
Ion chromatography (IC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was systematically investigated for determining the speciation of chromium in environmental samples. Firstly, the stability of complexes formed by Cr(III) with various aminopolycarboxylic acids was studied by electrospray ionization mass spectrometry (ESI-MS). The results showed that [Cr(EDTA)] was stable in solution. Secondly, various mobile phases were examined to separate Cl from chromium species by IC to avoid Cl interference. The separation of [Cr(EDTA)] and Cr(VI) was achieved on a new anion-exchange column (G3154A/102) using a mobile phase containing 20 mM NH4NO3 and 10 mM NH4H2PO4 at pH 7.0 without Cl interference. Detection limits for chromium species were below 0.2 μg/L with a direct injection of sample and without prior removal of interferences from the matrix. Finally, the proposed method was used for the determination of chromium species in contaminated waters.  相似文献   

14.
Ion-pairing chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS) used for the speciation of phosphorus is limited as the mobile phase containing organic solvents changes in detection sensitivity and the carbon precipitates on torch and cones. To address this issue, anion-exchange chromatography with ICP-MS has been used for the speciation of glyphosate, phosphate and aminomethylphosphonic acid in soil extracts. The separation of the targets on a new column was achieved within 5 min using an eluent containing 20 mM NH4NO3 at pH 5.1. Furthermore, since the polyatomic ions such as 14N16O1H+ and 15N16O+ from a nitrogen-based ion-pairing reagent interfered with ICP-MS detection of 31P, an octopole reaction system was investigated to determine whether the polyatomic interferences could be reduced. The results show that addition of He to the cell can benefit analyses by reducing such interferences, but at the expense of reduced sensitivity. The detection limits in the range of 1.0-1.5 μg L−1 (expressed as P) was achieved when 50 μL was injected using He as the collusion gas.  相似文献   

15.
Daus B  Weiss H  Mattusch J  Wennrich R 《Talanta》2006,69(2):430-434
The preservation of arsenic species in water samples is an indispensable method to avoid their changes during storage, if it is not possible to analyse them immediately. The aim of this investigation was to demonstrate the limitations of the suggested method by using phosphoric acid as a preservation agent. The samples remain stable for 3 months, even if they show evidence of high concentrations of iron or manganese. Critical is an increasing pH > 3. Theoretically, a precipitation of strengite (Fe3(PO4)2) could occur, which should be avoided. Phosphoric acid with a final concentration of 10 mM is recommended as a preservation agent, combined with keeping the samples cool (6 °C) and dark. Filtration of samples before preservation may be carried out with respect to the analytical aim to distinguish between the total and soluble fraction (without colloids). It was shown that filtered and non-filtered samples can be preserved by utilising the above mentioned scheme.  相似文献   

16.
The determination of seven arsenic species in seafood was performed using ion exchange chromatography on an IonPac AS7 column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The effect of five parameters on arsenic extraction recoveries was evaluated in certified reference materials. The recoveries of total arsenic and of arsenic species with the two best extraction media (100% H2O and 80% aqueous MeOH) were generally similar in the five seafood certified reference materials considered. However, because MeOH co-elutes with arsenite, which would result in a positively biased arsenite concentration, the 100% H2O extraction conditions were selected for validation of the method. Figures of merit (linearity, LOQs (0.019-0.075 mg As kg−1), specificity, trueness (with recoveries between 82% (As(III)) and 104% (As(V) based on spikes or certified concentrations), repeatability (3-14%), and intermediate precision reproducibility (9-16%) of the proposed method were satisfactory for the determination of arsenite, monomethylarsonic acid, dimethylarsinic acid, arsenate, arsenobetaine and arsenocholine in fish and shellfish. The performance criteria for trimethylarsine oxide, however, were less satisfactory. The method was then applied to 65 different seafood samples. Arsenobetaine was the main species in all samples. The percentage of inorganic arsenic varied between 0.4-15.8% in shellfish and 0.5-1.9% at the utmost in fish. The main advantage of this method that uses only H2O as an extractant and nitric acid as gradient eluent is its great compatibility with the long-term stability of both IEC separation and ICP-MS detection.  相似文献   

17.
A simple and highly efficient interface to couple capillary electrophoresis with inductively coupled plasma mass spectrometry by a microflow polyfluoroalkoxy nebulizer and a quadruple ion deflector was developed in this study. By using this interface, six arsenic species, including arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, and arsenocholine, were baseline‐separated and determined in a single run within 11 min under the optimized separation conditions. The instrumental detection limit was in the range of 0.02–0.06 ng/mL for the six arsenic compounds. Repeatability expressed as the relative standard deviation (n = 5) of both migration time and peak area were better than 2.5 and 4.3% for six arsenic compounds. The proposed method, combined with a closed‐vessel microwave‐assisted extraction procedure, was successfully applied for the determination of arsenic species in the Solanum Lyratum Thunb samples from Anhui province in China with the relative standard deviations (n = 5) ≤4%, method detection limits of 0.2–0.6 ng As/g and a recovery of 98–104%. The experimental results showed that arsenobetaine was the main speciation of arsenic in the Solanum Lyratum Thunb samples from different provinces in China, with a concentration of 0.42–1.30 μg/g.  相似文献   

18.
采用阴(Hamilton PRP-X100柱)阳(Dionex Ionpac CS-10柱)离子交换色谱-电感耦合等离子体质谱联用技术,分别以pH 10.3的20 mmol/L NH4HCO3和pH 2.0的5 mmol/L吡啶溶液为流动相,建立了As(Ⅲ)、As(Ⅴ)、一甲基砷酸(MMA)、二甲基砷酸(DMA)、砷甜菜碱AsB、砷糖PO4、砷糖OH、砷糖SO3、砷糖SO4砷形态的分析方法。采用微波消解法和超声溶剂提取法对不同海域10种紫菜和海带产品进行前处理,对As含量及其化学形态进行分析。实验表明,样品总砷的质量分数为1.7~38.7 mg/kg,样品萃取物中,As糖PO4和As糖OH为As的主要形态,其含量分别占可提取As的6.5%~67.7%和12.9%~86.2%,海带样品萃取物中还有As糖SO3和DMA被检测,其含量分别占可提取As的13.0%~52.1%和5.9%~17.4%。在紫菜和海带海藻类产品中,含As的化合物主要是毒性较低的有机砷。  相似文献   

19.
Extraction of sediments with phosphoric acid (0.5 M) and hydroxylamine hydrochloride (0.1 M) allowed the measurement of labile arsenic species while preserving the two redox states of arsenic. The forms and concentrations of arsenic species were measured using HPLC-ICP-MS. A Hamilton PRP X-100 strong anion exchange column using a 20 mM ammonium phosphate buffer (pH 6 and 9.2) was used to separate arsenic species. Recoveries of sediments spiked with As(V) were quantitative whereas for sediments spiked with As(III) recoveries of between 89 and 104% were obtained from four oxic certified reference sediments and an anoxic sediment. Application of the method to sediment samples from the marine Lake Macquarie, NSW, Australia, indicate that anoxic sediments can contain high concentrations of As(III), and two arsenosugars (sulfonate-ribose and sulfate-ribose). Extraction efficiencies for arsenic ranged between 6 and 82%. The arsenic species measured in sediments are strongly depended on the extraction procedure used. As(III) and arsenosugar concentrations in sediments that were freeze dried and oxidised were much less than in sediments that were not freeze dried and when exposure to air was keep to a minimum. Corresponding, As(V) concentrations tended to be higher in samples that were exposed to air.  相似文献   

20.
A method was developed for speciation analysis of arsenic in chicken meat. Different procedures were optimized for the recovery of arsenic compounds without destroying the original compounds, and 2 anion-exchange liquid chromatography columns were compared for the separation of arsenic species prior to on-line detection by inductively coupled plasma-mass spectrometry. The 2 species found were dimethylarsinic acid (106 +/- 5 ng/g) and arsenobetaine (37 +/- 4 ng/g). The stability of arsenic species in a chicken meat candidate reference material for at least 12 months was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏