首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
A sturdy home-built sheathless CE/ESI-QTOF-MS system was developed and optimized for carbohydrate analysis. The interface and employed methodology provided a simple analytical solution to laborious CE/MS interfacing methods and to problems in characterization of complex carbohydrate mixtures that require high-resolution separation of the components. The CE/ESI interface, feasible in any MS laboratory, consists of a one-piece CE column having the CE terminus in-laboratory shaped as a microsprayer and coated with copper. The CE microsprayer was inserted into an in-house made stainless steel clenching device and the whole assembly was mounted onto a quadrupole TOF mass spectrometer. The analytical potential of the interface in terms of suitability, microsprayer performance, copper coat durability, ionization efficiency, spray stability, and sensitivity was tested first on a simple mixture of standard saccharides, which were separated, resolved, and detected with high separation efficiency. The approach was next assessed for the screening of a biological sample, a complex mixture of O-glycosylated sialylated amino acids from urine of a patient suffering from Schindler disease. Preliminary data allow this method to be considered as one of general applicability in structural glycobiology and glycomics and easy to be implemented for proteomic surveys as well.  相似文献   

2.
In this study, an open‐tubular capillary electrochromatography (OT‐CEC) column with a monolithic layer of molecularly imprinted polymer (MIP) based on methacrylic acid, ethylene glycol dimethacrylate, and 4‐styrenesulfonic acid was utilized for the simultaneous separation and characterization of phospholipid (PL) molecular structures by interfacing with electrospray ionization‐tandem mass spectrometry (ESI‐MS‐MS). Introducing an MIP‐based monolith along with charged species at the OT column made it possible to separate PL molecules based on differences in head groups and acyl chain lengths in CEC. For the interface of OT‐CEC with ESI‐MS‐MS, a simple nanospray interface utilizing a sheath flow was developed and the resulting OT‐CEC‐ESI‐MS‐MS was able to separate PL standards (phosphatidylserines, phosphatidylethanolamines, phosphatidylglycerols, phosphatidic acid, and lysophosphatidylglycerols). The developed method was applied to human urinary lipid extracts, and resulted in the separation and structural identification of 18 molecules by data‐dependent collision‐induced dissociation.  相似文献   

3.
宋凤瑞  刘子阳 《分析化学》1998,26(7):865-867
建立了麻醉痛药物的电子轰击/串联质谱分析方法,得到了电子轰击/串联质谱(EI/MS/MS)条件下16种麻醉镇痛药物标准品的碰撞诱导解离(CID0-子离子谱,适合于复杂基质中这类化合物的定性分析,并利用所建方法对一肌注度冷丁者的尿样进行了检测。  相似文献   

4.
The online coupling of microchip electrophoresis (ME) as a fast, highly efficient, and low-cost miniaturized separation technique to mass spectrometry (MS) as an information-rich and sensitive characterization technique results in ME–MS an attractive tool for various applications. In this paper, we review the basic concepts and latest advances in technology for ME coupled to MS during the period of 2016–2021, covering microchip materials, structures, fabrication techniques, and interfacing to electrospray ionization (ESI)–MS and matrix-assisted laser desorption/ionization–MS. Two critical issues in coupling ME and ESI–MS include the electrical connection used to define the electrophoretic field strength along the separation channel and the generation of the electrospray for MS detection, as well as, a miniaturized ESI-tip. The recent commercialization of ME–MS in zone electrophoresis and isoelectric focusing modes has led to the widespread application of these techniques in academia and industry. Here we summarize recent applications of ME–MS for the separation and detection of antibodies, proteins, peptides, carbohydrates, metabolites, and so on. Throughout the paper these applications are discussed in the context of benefits and limitations of ME–MS in comparison to alternative techniques.  相似文献   

5.
Top‐down multidimensional mass spectrometry, interfacing electrospray ionization (ESI) with ion mobility mass spectrometry (IM‐MS), and energy resolved (gradient) tandem mass spectrometry (gMS2) are employed to characterize the stoichiometries, architectures, and intrinsic stabilities of coordinatively bound supramolecular polymers containing terpyridine functionalized ligands. As a soft ionization method, ESI prevents or minimizes unwanted assembly destruction. The IM dimension affords separation of the supramolecular ions by charge and collision cross‐section (a function of size and shape). The mobility separated ions are subsequently identified by their mass‐to‐charge‐ratios and isotope patterns in the orthogonal MS dimension. Finally, the gMS2 dimension reveals bond breaking proclivities and disintegration pathways of the assemblies. The described methodology does not require high sample purity due to the dispersive nature of the IM and MS steps. Its utility is demonstrated with the comprehensive analysis of bisterpyridine‐based metallomacrocycle mixtures and a tristerpyridine based complex with 3‐D nanosphere‐like architecture.

  相似文献   


6.
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.  相似文献   

7.
Summary Considerable progress has been made in the coupling of liquid chromatography and mass spectrometry over the past ten years. Three interfaces tend to dominate the LC/MS market: transport systems, direct liquid introduction, and the thermospray interface. In this paper the developments in direct liquid introduction interfacing for LC/MS will be reviewed. The paper will be published in two parts. Mass spectrometry and applications will be discussed in the second part. This first part of the review concentrates on the various instrumental aspects of direct liquid introduction, such as the design of vacuum systems, the interface probes and the desolvation chambers.  相似文献   

8.
Summary The coupling liquid chromatography and mass spectrometry is still growing in popularity. Direct liquid introduction has become one of the most important interfaces in LC/MS coupling. The various aspects of the interface have been investigated by several groups. This paper is the second part of a review of the developments in direct liquid introduction. Instrumental aspects of direct liquid introduction interfacing were discussed in the first part. This part will deal with the mass spectrometric aspects, i.e. chemical ionization and the influence of the various experimental conditions on the spectra. The applications of direct liquid introduction will also be reviewed briefly.  相似文献   

9.
付新梅  张蓉  吴祖望 《色谱》2014,32(11):1172-1180
基于多年运用液相色谱-二极管阵列检测/质谱(HPLC-DAD/MS)联用技术分析活性染料的实验积累,总结了HPLC-DAD/MS联用方法在商品活性染料结构鉴定中的重要应用。商品染料不需要纯化即可通过单次进样达到复杂组分的分离并得到光谱和质谱信息;结合衍生物质量差值法可推定染料的活性基种类和数目;采用二极管阵列检测器的全光谱扫描功能可以得到染料的发色体类别等有用的信息。HPLC-DAD/MS联用方法简便、快速、准确,尤其适用于多组分拼混的商品染料的结构鉴定,有较大的实用价值。通过对多组分商品染料活性灰、活性深黑、海洋蓝中关键组分的结构分析实例,介绍了HPLC-DAD/MS联用分析技术在未知商品活性染料结构分析中的应用。  相似文献   

10.
Elijah N.MCCOOL  孙良亮 《色谱》2019,37(8):878-886
自顶向下蛋白质组学的一个重要难题是缺乏与质谱可以在线连用并且可以提供高效蛋白质分离的液相分离技术。毛细管区带电泳与纳升反相色谱都可以与质谱在线连用,并且在复杂蛋白质样品分析方面也都有了显著的提升。在这里,我们首次比较了先进的纳升反相色谱-串联质谱与毛细管区带电泳-串联质谱平台用于自顶向下蛋白质组学分析。相对于纳升反相色谱-质谱而言,毛细管区带电泳-质谱可以将标准蛋白质样品的消耗量降低10倍,而且保持与纳升反相色谱-质谱相当的蛋白质信号强度。有意思的是,与毛细管区带电泳-质谱相比,纳升反相色谱-质谱可以获得更高的蛋白质分子的气相价态。这个现象可能是由于反相流动相中的高浓度乙腈使得蛋白质变性的更加充分。从1微克的大肠杆菌蛋白质样品中,毛细管区带电泳-串联质谱可以鉴定到159个蛋白质和513个蛋白质变体,而纳升反相色谱-串联质谱仅鉴定到105个蛋白质和277个蛋白质变体。当将大肠杆菌蛋白质的上样量提高到8微克时,纳升反相色谱-串联质谱可以鉴定到245个蛋白质和1004个蛋白质变体。由于纳升反相色谱-串联质谱具有比毛细管区带电泳-串联质谱更高的上样量与更宽的分离窗口,当蛋白质样品量不受限制时,纳升反相色谱-串联质谱具有明显的优势。但是,在痕量样品分析方面,毛细管区带电泳-串联质谱具有更大的潜力。  相似文献   

11.
Their characteristics as persistent organic pollutant and their toxicity (2,3,7,8-TCDD is named as a known human carcinogen) make the dioxins and related compounds a focus of interest in environmental analytical chemistry. In view of the widespread distribution of dioxins in the environment, these compounds must be monitored in several matrices, such as air, effluents, soil, sludge and biological samples. The analytical methodologies are especially difficult owing to the complexity of the mixtures of congeners (210 PCDD/Fs and 209 PCBs) and to the low detection limits required (ppb to ppq). Moreover, time-consuming sample preparation steps are needed owing to the presence of a large number of interfering compounds. The different toxicity of each congener requires the development of congener specific methods. This review of trace dioxin determination by mass spectrometry (MS) includes sample preparation and chromatographic separation. In this Special Feature, the use of different MS techniques such as low-resolution MS (LRMS) and high-resolution MS (HRMS) is discussed in terms of selectivity and sensitivity. The performances of other MS techniques, such as tandem MS (MS/MS) and time-of-flight MS (ToFMS), are compared. Quantification techniques, especially the isotopic dilution method, are also discussed. Conclusions and future perspectives are outlined.  相似文献   

12.
气相色谱-质谱方法检测磺酸类阴离子表面活性剂   总被引:5,自引:0,他引:5  
袁慧娟  宋国新  胡耀铭 《分析化学》2006,34(11):1629-1632
使用K I/DMF/(CF3CO)2O还原衍生方法,结合气相色谱-质谱(GC/MS)联用技术对磺酸类化合物进行了结构鉴定和成分分析。实验结果表明,这种新的还原衍生方法不仅方便快速、条件易控,而且产物稳定,具有良好的气相色谱-质谱行为,可以很好地解决磺酸类阴离子表面活性剂有效成分分析鉴定的难题。  相似文献   

13.
A procedure for identification of malting barley varieties using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) of ethanol‐soluble barley proteins (hordeins) is described. The hordeins were first extracted from milled barley grains by several extraction protocols (using different extraction agents and conditions). Hordein extracts were then analyzed directly via MALDI‐TOF MS without any preliminary purification or separation step, and the protein profiles of analyzed hordein extracts were compared in order to find out the most suitable extraction procedure for mass spectrometric analysis. The optimized procedure was successfully applied to identification of 13 malting barley varieties. Our results revealed that the proposed mass spectrometry‐based approach provides characteristic mass patterns of extracted hordeins, which can be advantageously used for barley variety identification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Profiling and imaging of tissues by imaging ion mobility-mass spectrometry   总被引:1,自引:0,他引:1  
Molecular profiling and imaging mass spectrometry (IMS) of tissues can often result in complex spectra that are difficult to interpret without additional information about specific signals. This report describes increasing data dimensionality in IMS by combining two-dimensional separations at each spatial location on the basis of imaging ion mobility-mass spectrometry (IM-MS). Analyte ions are separated on the basis of both ion-neutral collision cross section and m/z, which provides rapid separation of isobaric, but structurally distinct ions. The advantages of imaging using ion mobility prior to MS analysis are demonstrated for profiling of human glioma and selective lipid imaging from rat brain.  相似文献   

15.
Mass spectrometry has evolved to a key technology in the areas of metabolomics and proteomics. Centralized facilities generate vast amount of data, which frequently need to be processed off‐site. Therefore, the distribution of data and software, as well as the training of personnel in the analysis of mass spectrometry data, becomes increasingly important. Thus, we created a comprehensive collection of mass spectrometry software which can be run directly from different media such as DVD or USB without local installation. MASSyPup is based on a Linux Live distribution and was complemented with programs for conversion, visualization and analysis of mass spectrometry (MS) data. A special emphasis was put on protein analysis and proteomics, encompassing the measurement of complete proteins, the identification of proteins based on Peptide Mass Fingerprints (PMF) or LC‐MS/MS data, and de novo sequencing. Another focus was directed to the study of metabolites and metabolomics, covering the detection, identification and quantification of compounds, as well as subsequent statistical analyses. Additionally, we added software for Mass Spectrometry Imaging (MSI), including hardware support for self‐made MSI devices. MASSyPup represents a ‘ready to work’ system for teaching or MS data analysis, but also represents an ideal platform for the distribution of MS data and the development of related software. The current Live DVD version can be downloaded free of charge from http://www.bioprocess.org/massypup . Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Chip electrospray mass spectrometry for carbohydrate analysis   总被引:1,自引:0,他引:1  
Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.  相似文献   

17.
Ion mobility spectrometry (IMS) is a widespread separation technique used in various research fields. It can be coupled to liquid chromatography–mass spectrometry (LC–MS/MS) methods providing an additional separation dimension. During IMS, ions are subjected to multiple collisions with buffer gas, which may cause significant ion heating. The present project addresses this phenomenon from the bottom-up proteomics point of view. We performed LC–MS/MS measurements on a cyclic ion mobility mass spectrometer with varied collision energy (CE) settings both with and without IMS. We investigated the CE dependence of identification score, using Byonic search engine, for more than 1000 tryptic peptides from HeLa digest standard. We determined the optimal CE values—giving the highest identification score—for both setups (i.e., with and without IMS). Results show that lower CE is advantageous when IMS separation is applied, by 6.3 V on average. This value belongs to the one-cycle separation configuration, and multiple cycles may supposedly have even larger impact. The effect of IMS is also reflected in the trends of optimal CE values versus m/z functions. The parameters suggested by the manufacturer were found to be almost optimal for the setup without IMS; on the other hand, they are obviously too high with IMS. Practical consideration on setting up a mass spectrometric platform hyphenated to IMS is also presented. Furthermore, the two CID (collision induced dissociation) fragmentation cells of the instrument—located before and after the IMS cell—were also compared, and we found that CE adjustment is needed when the trap cell is used for activation instead of the transfer cell. Data have been deposited in the MassIVE repository (MSV000090944).  相似文献   

18.
Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation.The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A significant improvement in accuracy using this procedure was achieved. Applicability of the method was demonstrated in the analysis of amino acids using FIA as well as HPLC/MS. After an achiral separation of leucine and isoleucine, chiral mass spectrometric detection was successfully used for enantiomeric recognition.  相似文献   

19.
The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be combined, thus enabling a deeper understanding of the constituents of volatile samples on a molecular level. Although electron ionization is the most popular ionization method employed in GC/MS analysis, the need for softer ionization methods has led to the utilization of atmospheric pressure ionization sources. The last arrival to this family is the atmospheric pressure photoionization (APPI), which was originally developed for liquid chromatography / mass spectrometry (LC/MS). With a newly developed commercial GC‐APPI interface, it is possible to extend the characterization of unknown compounds. Here, first results about the capabilities of the GC/MS instrument under high or low energy EI or APPI are reported on a volatile gas condensate. The use of different ionization energies helps matching the low abundant molecular ions to the structurally important fragment ions. A broad range of compounds from polar to medium polar were successfully detected and complementary information regarding the analyte was obtained.  相似文献   

20.
In this study, we utilized a multidimensional peptide separation strategy combined with tandem mass spectrometry (MS/MS) for the identification of proteins in human serum. After enzymatically digesting serum with trypsin, the peptides were fractionated using liquid-phase isoelectric focusing (IEF) in a novel ampholyte-free format. Twenty IEF fractions were collected and analyzed by reversed-phase microcapillary liquid chromatography (microLC)-MS/MS. Bioinformatic analysis of the raw MS/MS spectra resulted in the identification of 844 unique peptides, corresponding to 437 proteins. This study demonstrates the efficacy of ampholyte-free peptide autofocusing, which alleviates peptide losses in ampholyte removal strategies. The results show that the separation strategy is effective for high-throughput characterization of proteins from complex proteomic mixtures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号