首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method for the analysis of chlorinated and brominated polycyclic aromatic hydrocarbon (Cl-/Br-PAHs) congeners in environmental samples, such as a soil extract, by comprehensive two-dimensional gas chromatography coupled to a high resolution time-of-flight mass spectrometry (GC×GC-HRTOF-MS) is described. The GC×GC-HRTOF-MS method allowed highly selective group type analysis in the two-dimensional (2D) mass chromatograms with a very narrow mass window (e.g. 0.02Da), accurate mass measurements for the full mass range (m/z 35-600) in GC×GC mode, and the calculation of the elemental composition for the detected Cl-/Br-PAH congeners in the real-world sample. Thirty Cl-/Br-PAHs including higher chlorinated 10 PAHs (e.g. penta, hexa and hepta substitution) and ClBr-PAHs (without analytical standards) were identified with high probability in the soil extract. To our knowledge, highly chlorinated PAHs, such as C(14)H(3)Cl(7) and C(16)H(3)Cl(7), and ClBr-PAHs, such as C(14)H(7)Cl(2)Br and C(16)H(8)ClBr, were found in the environmental samples for the first time. Other organohalogen compounds; e.g. polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs), and polychlorinated dibenzofurans (PCDFs) were also detected. This technique provides exhaustive analysis and powerful identification for the unknown and unconfirmed Cl-/Br-PAH congeners in environmental samples.  相似文献   

2.
A stir bar microextraction (SBSE) procedure for the determination of seven strobilurin fungicides in fruit samples using liquid chromatography (LC) and diode array detection (DAD) has been developed. The samples were sonicated in the presence of ethanol before submitting the extracts to SBSE. The incorporation of drazoxolon as an internal standard before SBSE allowed calibration without the need to use the standard additions method. Under the optimized conditions, detection limits were in the 0.3–2 ng g−1 range, corresponding to trifloxystrobin and metominostrobin, respectively. The SBSE–LC–DAD procedure showed good repeatability (RSD below 11% in all cases) and provided recoveries of 80–105% from spiked samples. The method was applied to fifteen fruit samples, and low levels of pyraclostrobin and trifloxystrobin were found in two of them.  相似文献   

3.
A method was developed to calculate the second dimension retention index of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) data using n-alkanes as reference compounds. The retention times of the C(7)-C(31) alkanes acquired during 24 isothermal experiments cover the 0-6s retention time area in the second dimension retention time space, which makes it possible to calculate the retention indices of target compounds from the corresponding retention time values without the extension of the retention space of the reference compounds. An empirical function was proposed to show the relationship among the second dimension retention time, the temperature of the second dimension column, and the carbon number of the n-alkanes. The proposed function is able to extend the second dimension retention time beyond the reference n-alkanes by increasing the carbon number. The extension of carbon numbers in reference n-alkanes up to two more carbon atoms introduces <10 retention index units (iu) of deviation. The effectiveness of using the proposed method was demonstrated by analyzing a mixture of compound standards in temperature programmed experiments using 6 different initial column temperatures. The standard deviation of the calculated retention index values of the compound standards fluctuated from 1 to 12 iu with a mean standard deviation of 5 iu.  相似文献   

4.
In this work the higher peak capacity and resolution of comprehensive two-dimensional gas chromatography (GCxGC) has been successfully applied, for the first time, to tentatively identify several polar organic compounds of organic extracts of aqueous phases resulting from microwave demulsification process of water-in-crude oil emulsions. Results have shown that higher temperatures and longer exposure time to microwave irradiation produced water phases with a wider variety of polar organic compounds. The microwave process showed to be suitable for the extraction of several polar compounds classes of petroleum. The proposed microwave extraction method and GCxGC identification of polar compounds of petroleum samples are of practical interest for the petrochemical industry due to corrosion and related problems associated with these polar compounds in refinery equipments. The GCxGC/time-of-flight MS technique shows to be very important in the total separation of different classes of compounds and allows the identification of many compounds in these classes.  相似文献   

5.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

6.
A method for the trace analysis of methylmercury (MeHg) and Hg(II) in water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ alkylation with sodium tetraethylborate and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The limits of quantification of MeHg and Hg(II) are 20 and 10 ng L−1 (Hg), respectively. The method shows good linearity and the correlation coefficients are higher than 0.999. The average recoveries of MeHg and Hg(II) in tap or river water sample are 102.1-104.3% (R.S.D.: 7.0-8.9%) and 105.3-106.2% (R.S.D.: 7.4-8.5%), respectively. This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of MeHg and Hg(II) in tap and river water samples.  相似文献   

7.
Polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) are listed as persistent organic pollutants (POPs) under the Stockholm Convention. Because they have similar physical and chemical properties, they are coeluted and are usually analyzed separately by different gas chromatography high-resolution mass spectrometry (GC-HRMS) methods. In this study, a novel method was developed for simultaneous analysis of six indicator PCBs, 12 dioxin-like PCBs, and 16 PCNs using isotope dilution comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HRTOF-MS). The method parameters, including the type of GC column, oven temperature program, and modulation period, were systematically optimized. Complete separation of all target analytes and the matrix was achieved with a DB-XLB column in the first dimension and a BPX-70 column in the second dimension. The isotope dilution method was used for quantification of the PCBs and PCNs by GC × GC-HRTOF-MS. The method showed good linearity from 5 to 500 pg μL−1 for all the target compounds. The instrumental limit of detection ranged from 0.03 to 0.3 pg μL−1 for the 18 PCB congeners and from 0.09 to 0.6 pg μL−1 for the 16 PCN congeners. Repeatability for triplicate injections was always lower than 20%. The method was successfully applied to the determination of 18 PCBs present at 0.9–2054 pg g−1 and 16 PCNs present at 0.2–15.7 pg g−1 in three species of fish. The GC × GC-HRTOF-MS results agreed with those obtained by GC-HRMS. The GC × GC-HRTOF-MS method proved to be a sensitive and accurate technique for simultaneous analysis of the selected PCBs and PCNs. With the excellent chromatographic separation offered by GC × GC and accurate mass measurements offered by HRTOF-MS, this method allowed identification of non-target contaminants in the fish samples, including organochlorine pesticides and polycyclic aromatic hydrocarbons.  相似文献   

8.
The applicability of comprehensive two-dimensional gas chromatography (GC×GC) for flavonoids analysis was investigated by separation and identification of flavonoids in standards, and a complex matrix natural sample. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of flavonoids was compared on two complementary column sets. Whilst the BPX5/BPX50 (NP/P) column set offers better overall separation, BPX50/BPX5 (P/NP) provides better peak shape and sensitivity. Comparison of the identification power of GC×GC-TOFMS against both the NIST05 MS library and a laboratory (created in-house) TOFMS library was carried out on a flavonoid mixture. The basic retention index information on high-performance capillary columns with a non-polar stationary phase was established and database of mass spectra of trimethylsilyl derivatives of flavonoids was compiled. TOFMS coupled to GC×GC enabled satisfactory identification of flavonoids in complex matrix samples at their LOD over a range of 0.5-10 μg/mL. Detection of all compounds was based on full-scan mass spectra and for each compound a characteristic ion was chosen for further quantification. This study shows that GC×GC-TOFMS yields high specificity for flavonoids derived from real natural samples, dark chocolate, propolis, and chrysanthemum.  相似文献   

9.
牛鲁娜  刘泽龙  周建  蔡新恒  田松柏 《色谱》2014,32(11):1236-1241
建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析柴油馏分中饱和烃的分子组成的方法。结合谱库检索、质谱图解析、沸点与分子结构关系和全二维谱图特征,定性(或归类)了焦化柴油饱和烃组分中1057个化合物单体,其中正构烷烃排列规律性最强,一环~三环环烷烃按照极性和沸点的差异呈瓦片状分布在其上方。另外,还准确区分了在一维气相色谱上共流出的正构烷基环己烷和正构烷基环戊烷,以及正构 α 单烯烃。根据质谱采集的总离子流色谱图,采用峰面积归一化法得到了饱和烃组分的碳数分布结果,并将该方法应用于研究不同类型柴油馏分饱和烃的分子组成特点。结果表明,催化裂化和焦化柴油馏分饱和烃组分的化合物类型和分布各不相同。分子组成分析能为油品加工工艺机理的研究提供方法支持。  相似文献   

10.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

11.
Guo K  Zhou J  Liu Z 《色谱》2012,30(2):128-134
通过对升温速度、二维补偿温度、调制周期等关键实验参数的优化,建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析重馏分油中芳烃组分的方法,得到了重馏分油芳烃组分按环数分布的二维点阵图。根据谱库检索、标准化合物对照及文献报道,对重馏分油芳烃组分中菲、甲基菲及芘、苯并蒽等常见多环芳烃(PAH)进行了准确定性,并将该方法应用到重馏分油加氢处理工艺研究中,对菲、芘的加氢处理产物进行了定性分析。该研究为重馏分油芳烃组分的准确定性提供了新的技术手段,为加深对油品加氢规律的认识提供了技术支持。全二维气相色谱与普通一维色谱对比,在重馏分油的芳烃组分分析上体现了极大优势。  相似文献   

12.
A direct, simple and solvent‐free method based on headspace stir bar sorptive extraction and thermal desorption gas chromatography with mass spectroscopy was developed to determine 13 musk fragrances (six polycyclic musks, three nitro musks and four macrocyclic musks) in sludge without sample treatment. The optimal headspace stir bar sorptive extraction conditions were achieved when a polydimethylsiloxane stir bar was exposed for 45 min in the headspace of a 10 mL vial filled with 100 mg of sludge mixed with 0.2 mL of water stirred at 750 rpm at 80°C. The stir bar was then desorbed in the thermal desorption gas chromatography and mass spectrometry system, obtaining limits of detection between 5 and 30 ng/g. The method applicability was tested with sewage sludge from two urban wastewater treatment plants and from a potable water treatment plant. Results showed galaxolide and tonalide to be the most abundant musk fragrances found in wastewater treatment plants with maximal concentrations of 9240 and 7500 ng/g, respectively. Maximum concentration levels between 35 and 635 ng/g were found for musk ketone, musk moskene, traseolide, phantolide and celestolide in this kind of samples. Concentrations below the limits of quantitation of phantolide, galaxolide, tonalide and musk ketone were found in sludge from a potable water treatment plant.  相似文献   

13.
Future understanding of differences in the composition and sensory attributes of wines require improved analytical methods which allow the monitoring of a large number of volatiles including those present at low concentrations. This study presents the optimization and application of a headspace solid-phase microextraction (HS-SPME) method for analysis of wine volatiles by comprehensive two-dimensional gas chromatography (GC×GC) time-of-flight mass spectrometry (TOFMS). This study demonstrates an important advancement in wine volatile analysis as the method allows for the simultaneous analysis of a significantly larger number of compounds found in the wine headspace compared to other current single dimensional GC-MS methodologies. The methodology allowed for the simultaneous analysis of over 350 different tentatively identified volatile and semi-volatile compounds found in the wine headspace. These included potent aroma compound classes such as monoterpenes, norisoprenoids, sesquiterpenes, and alkyl-methoxypyrazines which have been documented to contribute to wine aroma. It is intended that wine aroma research and wine sensory research will utilize this non-targeted method to assess compositional differences in the wine volatile profile.  相似文献   

14.
A methodology to analyze organochlorine pesticides (OCPs) in water samples has been accomplished by using headspace stir bar sorptive extraction (HS-SBSE). The bars were in house coated with a thick film of PDMS in order to properly work in the headspace mode. Sampling was done by a novel HS-SBSE system whereas the analysis was performed by capillary GC coupled mass spectrometric detection (HS-SBSE-GC-MS). The extraction optimization, using different experimental parameters has been established by a standard equilibrium time of 120 min at 85 degrees C. A mixture of ACN/toluene as back extraction solvent promoted a good performance to remove the OCPs sorbed in the bar. Reproducibility between 2.1 and 14.8% and linearity between 0.96 and 1.0 were obtained for pesticides spiked in a linear range between 5 and 17 ng/g in water samples during the bar evaluation.  相似文献   

15.
The present investigation is focused on a simple flow modulator (FM), for comprehensive two-dimensional gas chromatography (GC×GC). The interface is stable at high temperatures, and consists of a metallic disc (located inside the GC oven) with seven ports, which are connected to an auxiliary pressure source via two branches, to the first and second dimension, to a waste branch (linked to a needle valve) and to an exchangeable modulation loop (2 ports). The ports are connected via micro-channels, etched on one of the inner surfaces of the disc. Modulation is achieved using a two-way electrovalve, connected on one side to the additional pressure source, and to the two metal branches, on the other. An FM enantio-GC×polar-GC method (using a flame ionization detector) was optimized (a 40-μL loop was employed), for the analysis of essential oils. As an example, an application on spearmint oil is shown; the method herein proposed was subjected to validation. Finally, an FM GC×GC diesel experiment was carried out, using an apolar-polar column combination, to demonstrate the effectiveness of the modulator in the analysis of a totally different sample-type.  相似文献   

16.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

17.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.  相似文献   

18.
This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL−1, when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement of fluoxetine in typical and trace concentration levels.  相似文献   

19.
A simple and highly sensitive method called thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 4-nonylphenol (NP) and 4-tert.-octylphenol (OP) in water samples, is described. NP and OP in samples are extracted from water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 °C) in a headspace vial. Then the extract is high sensitively analyzed by TD-GC-MS without any derivatization step. The optimum SBSE conditions are realized at an extraction time of 60 min. The detection limits are 0.02 ng ml−1 for NP and 0.002 ng ml−1 for OP. The method shows good linearity over the concentration range of 0.1-10 ng ml−1 for NP and 0.01-10 ng ml−1 for OP, and the correlation coefficients are higher than 0.999. The average recoveries of NP and OP are higher than 97% (R.S.D.: 3.6-6.2%) with correction using the added surrogate standards, 4-(1-methyl) octylphenol-d5 and deuterium 4-tert.-octylphenol. This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of NP and OP in tap and river water samples.  相似文献   

20.
A novel method called thermal desorption (TD) with in tube silylation followed by gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of alkylphenols (APs) in river water samples, is described. APs are extracted from river water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. The stir bar coated with polydimethylsiloxane (PDMS) is added to 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 degrees C) in the vial. Then, the PDMS stir bar is subjected to TD with in tube silylation followed by GC-MS. The detection limit is of the sub pg ml(-1) (ppt) level. The method shows good linearity and the correlation coefficients are higher than 0.99 for all analytes. The average recoveries of APs are higher than 90% (R.S.D.: 3.6-14.8%, n=6). This simple and sensitive analytical method may be used in the determination of trace amounts of APs in river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号