首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ferrer R  Beltrán JL  Guiteras J 《Talanta》1998,45(6):1073-1080
Synchronous fluorescence spectra of mixtures containing ten polycyclic aromatic hydrocarbons (anthracene, benz[a]anthracene, benzo[a]pyrene, chrysene, fluoranthene, fluorene, naphthalene, perylene, phenanthrene and pyrene) have been used for the determination of these compounds by Partial Least Squares Regression (PLSR), using both PLS-1 and PLS-2. Different procedures have been used for the pretreatment of the data in order to obtain better models, and the size of the calibration matrix has also been studied. The best models have been used for the determination of the above mentioned PAHs in spiked natural water samples at concentration levels between 4 and 20 ng ml−1. Recoveries ranged from 80 to 120% in most cases, although fluorene gave significantly lower results.  相似文献   

2.
Supercritical fluid extraction was applied to the determination of naturally contaminated polycyclic aromatic hydrocarbons (PAHs) in bird tissue by liquid chromatography with fluorescence detection (LC-FL). Recoveries (> 90%) and relative standard deviations (< or = 7.7%) were satisfactory. The levels of 10 PAHs were analyzed in 6 classes of tissues (heart, liver, intestine, muscle, lung, and kidney) of 10 buzzards and 2 tawny owls, predatory birds from the Galicia (northwest Spain). The PAHs found most abundantly were pyrene, fluoranthene, benzo[a]anthracene, and anthracene. Chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[ghi]perylene, and indeno[1,2,3-cd]pyrene were not detected. Intestine, kidney, and lung were more polluted than other tissues.  相似文献   

3.
张小涛  张丽  阮艺斌  王维维  姬厚伟  万强  林福呈  刘剑 《色谱》2017,35(10):1105-1110
建立了气相色谱-串联质谱同时检测卷烟滤嘴中15种多环芳烃的方法。卷烟滤嘴用二氯甲烷振荡萃取后,经0.22μm有机相滤膜过滤,采用DB-5MS色谱柱(30 m×0.25 mm,0.25μm)进行分离,电子轰击源、正离子模式下以多反应监测模式进行检测,内标法进行定量。15种多环芳烃(苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并[a]蒽、屈、苯并[b]荧蒽、苯并[k]荧蒽、苯并[a]芘、二苯并[a,h]蒽、苯并[g,h,i]苝和茚并[1,2,3-c,d]芘)的线性关系良好,相关系数(R~2)为0.991 4~0.999 9。15种多环芳烃在低、中、高3个添加水平下的平均回收率为81.6%~111.2%;除了芴在低添加水平时相对标准偏差为19.2%外,其他相对标准偏差均小于16%。15种多环芳烃的检出限为0.02~0.24 ng/滤嘴,定量限为0.04~0.80 ng/滤嘴。方法前处理简便,具有快速、准确、灵敏度高及重复性好的优点,适用于卷烟滤嘴中多环芳烃的分析。  相似文献   

4.
Länge K  Griffin G  Vo-Dinh T  Gauglitz G 《Talanta》2002,56(6):1153-1161
Antibodies of a polyclonal antiserum against benzo[a]pyrene were characterized by determining thermodynamic and kinetic constants of the antigen–antibody reaction. Label-free binding assays with optical detection based on reflectometric interference spectroscopy were performed to determine these constants. Different evaluation methods for kinetic measurements were compared. Also, cross-reactivity against two other polycyclic aromatic hydrocarbons, chrysene and pyrene, was checked. The affinity constant between the antibodies and benzo[a]pyrene in homogeneous phase was determined to be K=(5.3±0.3)×107 M−1 which was in the middle of the usual range of antibody affinities. The association rate constant for the reaction at the surface was determined to be (3.8±0.9)×105 M−1 s−1, the dissociation rate constant as (9.7±0.5)×10−3 s−1. Different evaluation methods applied to the kinetic measurements led to the same results. This antiserum would be suitable for the selective determination of benzo[a]pyrene in concentrated samples.  相似文献   

5.
The most suitable wavelength intervals were selected for the determination of 4 polycyclic aromatic hydrocarbons (PAHs; benzo[g,h,i]perylene, dibenzo[a,h]anthracene, pyrene, and triphenylene) in very complex mixtures of 11 PAHs: anthracene, benz[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[g,h,i]perylene, benzo[k]fluoranthene, chrysene, dibenz[a,h]anthracene, phenanthrene, pyrene, and triphenylene. The multiple linear regression algorithm was applied to measurements made in several wavelength intervals previously selected on the basis of sensitivity and minimum number of interfering compounds. Of the different models obtained, those displaying minimum error propagation in the analytical result were selected. By applying the models proposed in this study, we precisely and accurately determined benzo[g,h,i]perylene, dibenz[a,h]anthracene, pyrene, and triphenylene in complex mixtures--a feat that could not be achieved by the use of constant-wavelength spectrofluorimetry in combination with second-derivative techniques.  相似文献   

6.
This paper presents the characterization of polycyclic aromatic hydrocarbons (PAHs) in solid-surface fluorescence as the first step for obtaining new optical sensors for PAHs screening. The fluorescence properties of the EPA-PAHs (naphthalene, acenaphthene, acenaphthylene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[k]fluoranthene, benzo[b]fluoranthene, benzo[a]pyrene, indeno [1,2,3-cd]pyrene, benzo[g,h,i]perylene and dibenzo[a,h]anthracene) on five types of solid-surfaces were evaluated. The experimental variables (pH and percentage of organic solvent in samples) were studied, obtaining different possibilities for making individual sensors for some of these PAHs and the best conditions for developing sensors for PAH screening were also studied.  相似文献   

7.
The formation of polycyclic aromatic hydrocarbons (PAHs) during pyrolysis process of phenylalanine had been studied. Ten PAHs, including fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[k]fluoranthene, benzo[e]pyrene, and benzo[a]pyrene were analyzed by gas chromatography-mass spectrometry using selective ion monitoring mode. This technique offers the capability to analyze trace amounts of PAHs in phenylalanine pyrolyzates. The pyrolysis was carried out in a micro-furnace with quartz furnace liner. The injection was conducted with glass pelletizer syringe to avoid metal contamination. Qualitative results were obtained at 900 degrees C and quantitative analysis of 10 PAHs was done for 700 and 900 degrees C.  相似文献   

8.
戴雪伟  卫碧文  望秀丽  于文佳  徐永威 《色谱》2015,33(10):1059-1064
建立了一种超高效合相色谱-二极管阵列检测器快速分析塑料制品中萘、苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并(a)蒽、(屈艹) 、苯并(b)荧蒽、苯并(k)荧蒽、苯并(j)荧蒽、苯并(e)芘、苯并(a)芘、茚并(1,2,3-cd)芘、二苯并(a,h)蒽、苯并(g,h,i)苝(二萘嵌苯)的方法。以甲苯为溶剂,超声萃取实际塑料制品中的多环芳烃,经超高效合相色谱分析。采用Daicel IB-3手性色谱柱,以CO2为流动相,甲醇/乙腈(25:75, v/v)为流动相助溶剂,在柱温为40 ℃,背压为15.17 MPa的条件下,18种多环芳烃在8.5 min之内实现基线分离。18种多环芳烃的线性范围为0.05~50 mg/L(r≥0.9995),定量限(S/N> 10)为0.05 mg/L。加标回收率为78.3%~117.6%,相对标准偏差(RSD, n=5)小于5%。该方法具有分析速度快、分离效率高、节约有机溶剂的优点。  相似文献   

9.
Optimized separation of a mixture of 16 priority pollutant polycyclic aromatic hydrocarbons (PAHs) by high performance liquid chromatography (HPLC) using the sequential simplex optimization method was accomplished by varying the starting and ending compositions of acetonitrile and water, linear gradient time, mobile phase flow rate, column temperature and holding time of the final mobile phase composition. Focusing on the two sets of difficult-to-separate pairs (acenaphthene–fluorene and benzo[g,h,i]perylene–indeno[1,2,3-c,d]pyrene), analysis time was reduced by about ten percent through the use of an organic modifier (isopropanol or methanol), under both optimum and near-optimum conditions, while maintaining good separation of the remaining PAHs. High sensitivity for all of the 16 PAHs was achieved by wavelength programming during elution using five wavelengths (224, 235, 254 270 and 296 nm), depending upon the molar absorptivities of the individual compounds. Detection limits (DLs) ranging from 0.002 (benzo[a]pyrene) to 0.140 μg ml−1 (acenaphthene) were achieved for this set of 16 standard compounds.  相似文献   

10.
In the presented study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC?×?GC-TOFMS) was shown to be a powerful tool for the simultaneous determination of various groups of contaminants including 18 polychlorinated biphenyls (PCBs), seven polybrominated diphenyl ethers (PBDEs), and 16 polycyclic aromatic hydrocarbons (PAHs). Since different groups of analytes (traditionally analyzed separately) were included into one instrumental method, significant time savings were achieved. Following the development of an integrated sample preparation procedure for an effective and rapid isolation of several groups of contaminants from fish tissue, the GC?×?GC-TOFMS instrumental method was optimized to obtain the best chromatographic resolution and low quantification limits (LOQs) of all target analytes in a complex mixture. Using large-volume programmable temperature vaporization, the following LOQs were achieved-PCBs, 0.01-0.25 μg/kg; PBDEs, 0.025-5 μg/kg; PAHs 0.025-0.5 μg/kg. Furthermore, several capillary column combinations (BPX5, BPX50, and Rxi-17Sil-ms in the first dimension and BPX5, BPX50, Rt-LC35, and HT8 in the second dimension) were tested during the experiments, and the optimal separation of all target analytes even of critical groups of PAHs (group (a): benz[a]anthracene, cyclopenta[cd]pyrene and chrysene; group (b): benzo[b]fluoranthene, benzo[j]fluoranthene and benzo[k]fluoranthene; group (c): dibenz[ah]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was observed on BPX5?×?BPX50 column setup. Moreover, since the determination of target analytes was performed using TOFMS detector, further identification of other non-target compounds in real life samples was also feasible.  相似文献   

11.
Gas chromatography–mass spectrometry was used for the determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in surface soils from seventeen areas in Southeast Romania, including sites placed in the vicinity of Galati iron and steel plant and Lower Prut Meadow natural reserve in Galati County. The total concentration of PAHs (TPAHs) in the investigated soils ranges from 0.003 mg/kg to 38.524 mg/kg dry weight. According to Romanian legislation for trace organic compounds in soils of different uses, the amounts of PAHs in soils from the industrial zone exceed the normal values for the majority of individual PAHs. The lowest concentrations were found in soils sampled from the protected area of Lower Prut Meadow natural reserve and the highest near a zootechnique farm in the Prut River basin, where the alert levels exceeded for the less sensitive area in the case of TPAHs and benzo[b]fluoranthene and for the sensitive area in the case of chrysene, benz[a]anthracene, benzo[k]fluoranthene and benzo[g,h,i]perylene. The sources of PAH contaminating soils are complex, being of both pyrogenic and petrogenic origins.  相似文献   

12.
This paper presents the development of two optosensors for the determination of four polycyclic aromatic hydrocarbons (anthracene, benzo[a]pyrene, fluoranthene and benzo[b]fluoranthene) using a photomultiplier device and an intensified coupled charge device (ICCD) as optical transducers, respectively. These optosensors are based on the on-line immobilization of the analytes onto a non-ionic resin solid support (Amberlite XAD-4) in a continuous flow system, followed by the measurement of their native fluorescence. The determinations were performed using 15 mM H2PO4-/HPO42- buffer solution at pH 7 and 25% 1,4-dioxane. Detection limits were 6.4 and 9.3 for ANT, 3.3 and 2.5 for BbF, 1.4 and 13.2 for FLT, and 1.7 and 7.8 for BaP using optosensor 1 or 2, respectively. Relative standard deviations were 7.9 and 6.7 for ANT at 50 ng mL-1, 3.5 and 7.4 for BbF at 60 ng mL-1, 3.6 and 8.9 for FLT at 50 ng mL-1, and 6.7 and 11.6 for BaP at 50 ng mL-1 using optosensor 1 or 2, respectively. Finally, a critical comparison between the two configurations based on different transducers (photomultiplier and ICCD) for resolving and simultaneously determining mixtures of the polycyclic aromatic hydrocarbons under study in water samples (tap and mineral waters) were carried out.  相似文献   

13.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90-115%) and RSD % (< or =7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

14.
刘颖  陈玲  唐银健  黄清辉  赵建夫 《色谱》2007,25(3):356-361
建立了高效液相色谱-二极管阵列检测器(PDA)测定上海市黄浦江表层沉积物中16种多环芳烃(PAHs)的方法。在保留时间定性分析的基础上,利用PDA获取的紫外扫描光谱图对目标组分进行了准确的定性,并通过异构体紫外光谱图中特征峰的差异有效地识别了样品中的4种异构体,即苯并[b]荧蒽、 苯并[k]荧蒽、 苯并[a]芘和苯并[e]芘。通过检测波长的优化,减少了干扰物的影响,提高了检测灵敏度;针对分离度较差的两种目标组分(苯并[b]荧蒽和苯并[k]荧蒽)的定量进行了分析讨论。该方法对16种PAHs的检出限(以干基计)介于1.1~18.3 ng/g之间,具有较高的方法灵敏度。黄浦江表层沉积物测定结果表明,除二氢苊外的15种PAHs都被检出,含量为10.1~253.0 ng/g。  相似文献   

15.
A simple and rapid method for the highly sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in water was developed. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene in water were concentrated into sodium dodecyl sulfate (SDS)-alumina admicelles. The collection was performed by adding SDS and alumina particles into the sample solution at pH 2. After gentle mixing, the resulting suspension was passed through a membrane filter to collect the SDS admicelles containing highly concentrated PAHs. The filter was placed on a slide glass and then covered admicellar layer with a fused silica glass plate before setting in a fluorescence spectrometer. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene were selectively determined by the synchronous fluorescence scan (SFS) analysis with keeping wavelength intervals between excitation and emission to 98, 35, 29, and 45 nm, respectively. Because of the minimum spectral overlapping, 1-40 ng l−1 of benzo[a]pyrene, benzo[k]fluoranthene, and perylene as well as 10-150 ng l−1 of pyrene were selectively determined with eliminating the interferences of other 12 PAHs. The detection limits were 0.3 ng l−1 for benzo[a]pyrene, benzo[k]fluoranthene, and perylene, and 1 ng l−1 for pyrene. They were 2-3 orders of magnitude lower than the detection limits in normal aqueous micellar solutions. The application to water analysis was studied.  相似文献   

16.
This paper presents a trisolvent ultrasonic extraction and HPLC analysis method for the determination of 11 polycyclic aromatic hydrocarbons in air particulate collected on an air filter by a commercial high volume air sampler. A reverse phase column, Vydac 201 TP, and a gradient mobile phase, acetonitrile/water, were used. The 11 PAHs, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a, h]anthracene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene, and coronene were completely resolved under experimental conditions. All the PAHs except coronene were monitored by fluorescence with λex=270 nm, λem>389 nm. Coronene was monitored by UV with λ=300 nm. The methodology was evaluated by spiking SRM 1649 with a PAH standard and then going through different extraction procedures and analyzing the PAH concentrations without clean-up. An external standard method was used for quantitation. The recovery yields for fluoranthene, benz[a]anthracene, benzo[a]pyrene, benzo[ghi]perylene and indeno[l,2,3-cd]pyrene were above 90%. The detection limits of PAH with fluorescence at λex=270 nm, λem>389 nm ranged from 5.7 pg to 69.5 pg.  相似文献   

17.
Chinese ink stick has a long history and a special importance in Chinese culture. Its main components are soot (normally pine wood soot and lamp soot) and animal glue; however, additives were added from time to time for different purposes. In order to see whether the two types of soot can be differentiated and the other constituents in Chinese ink sticks can be identified or not by Pyrolysis-Gas Chromatography-Mass Spectrometry (Py-GC-MS) and GC-MS techniques, an initial study has been carried out. The main polycyclic aromatic hydrocarbons (PAHs) in soot could be identified, which are anthracene, fluoranthene, triphenylene and benz[e]acephenanthrylene. The main difference between those two types of soot is that the detectable amount of PAHs in lamp soot is much lower than in pine wood soot. In addition to this, the relative concentration of the main polycyclic aromatic hydrocarbons including anthracene, fluoranthene, pyrene, triphenylene and its isomer, benzo[k]fluoranthene and its isomers are different in the two types of soot. The relative content of benzo[k]fluoranthene is higher in pine soot than in lamp soot, which could be used to as a criterion to differentiate the two types of soot. Py-GC-MS technique is a very effective method to identify the main components of Chinese ink sticks, including the PAHs of soot, binding media and the additives of camphor and borneol in one analysis.  相似文献   

18.
Paolo Bruno  Maria Tutino 《Talanta》2007,72(4):1357-1361
The determination of polycyclic aromatic hydrocarbons (PAHs) contained in samples of particulate matter (PM), collected with low volume pumps, were carried out with an high sensitivity method that comes from several revisions of a previous method. The present work describes how, by using programmable temperature vaporization (PTV) and a mass selective detector with inert ionic source for the GC-MS analysis and the modifications of microwave-assisted extraction (MAE), the sensitivity of the method can be increased.The PAHs chosen for testing the method are: benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1,2,3-cd]pyrene (Ip) and dibenzo[a,h]anthracene (DbA). They, in fact, belong to that group of substances that are the most harmful for human health for their carcinogenicity.PAHs recoveries for spiked standard solutions at different concentrations were between 95 and 100% with relative standard deviation ranging from 1 to 3%. The revised method was validated using a 1649a urban dust standard reference material (SRM). The results obtained were in good agreement with certified values. The high sensitivity of the method allows to carry out analyses using only a half of the sampled filter (usually 47 mm diameter membranes). In this way, the other half can be used for the characterization of the other components of PM (heavy metals, organic carbon, ions, etc). The last step has been constituted by application of the optimized method on real samples collected in two cities located in Southern Italy (Bari and Taranto).  相似文献   

19.
In the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg?1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg?1.  相似文献   

20.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs) in human hair. Fifteen kinds of PAHs classified as priority pollutants by the US EPA were quantified with four perdeuterated PAHs as internal standards. After 50 mg hair samples were washed with n-hexane to remove external contamination of PAHs, the samples were digested in 2.5 M sodium hydroxide. The digests were extracted with n-hexane and then analyzed by HPLC. Eleven kinds of PAHs were identified in hair samples of 20 subjects, and 10 kinds of PAHs were eventually quantified using the internal standards. For anthracene, chrysene and benzo[k]fluoranthene, significant differences were observed between smokers and non-smokers. Although benzo[b]fluoranthene, dibenz[a,h]anthracene, benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were observed in the particulates of indoor and outdoor air, they were not detected in all hair samples. The analysis of PAHs in human hair should be useful as a new biomarker to evaluate the exposure to PAHs.  相似文献   