首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper reports an electroanalytical method developed for determining the antioxidant tert-butylhydroquinone (TBHQ) in biodiesel, based on the enhancement effect of cetyltrimethylammonium bromide (CTAB). In pH 6.5 Britton–Robinson buffer, a poorly defined oxidation peak was observed for TBHQ at a carbon paste electrode (CPE). In the presence of low concentrations of CTAB, however, the oxidation peak current was markedly increased. Several parameters were studied and optimized for the development of this methodology, and under optimal conditions the oxidation peak current was proportional to TBHQ concentration in the range of (1.05–10.15) × 10−6 mol L−1, with limits of detection and quantification of 7.11 × 10−8 mol L−1 and 2.37 × 10−7 mol L−1, respectively, by linear sweep voltammetry (LSV). The method was applied to TBHQ determination in soybean biodiesel samples. The results were satisfactory in comparison with those obtained using high-performance liquid chromatography (HPLC).  相似文献   

2.
A novel procedure for trace methylmercury determinations by anodic stripping voltammetry at a gold film electrode is presented. Measurements were performed in a flow system. For selective determination of methylmercury, the Hg2+ ions were masked by complexation with DTPA. Hg-DTPA complex is not reduced at the gold film electrode at the potential of methylmercury reduction to the metallic state. The calibration graph was linear from 5 × 10−9 to 1 × 10−7 mol L−1 for an accumulation time 600 s. A detection limit (based on 3σ criterion) for methylmercury was 2.3 × 10−9 mol L−1. The validation of the proposed procedure was made by analyses of human hair certified reference material.  相似文献   

3.
A new noncovalent approach for the dissolution of MWNTs in water by azocarmine B (ACB) is reported. Through a simple electro-polymerization procedure, a novel electrochemical NO sensor based on water-soluble MWNTs and polyazocarmine B (PACB) nanofilm electrode was prepared, which showed excellent electrocatalytic activity towards the oxidation of nitric oxide (NO). The oxidation current linearly increased with the nitric oxide concentration in the range of 2.2 × 10−7–1.2 × 10−4 mol L−1 with a low detection limit of 2.8 × 10−8 mol L−1. The sensor has the merit of good stability, reproducibility, high sensitivity and selectivity, and it can be used to monitor NO released from rat liver cells effectively.  相似文献   

4.
This work reports on a novel chitosan–hematite nanotubes composite film on a gold foil by a simple one-step electrodeposition method. The hybrid chitosan–hematite nanotubes (Chi–HeNTs) film exhibits strong electrocatalytic reduction activity for H2O2. Interestingly, two electrocatalytic reduction peaks are observed at −0.24 and −0.56 V (vs SCE), respectively, one controlled by surface wave and the other controlled by diffusion process. The Chi–HeNTs/Au electrode shows a linear response to H2O2 concentration ranging from 1 × 10−6 to 1.6 × 10−5 mol L−1 with a detection limit of 5 × 10−8 mol L−1 and a sensitivity as high as 1859 μA μM−1 cm−2.  相似文献   

5.
A thionine modified aligned carbon nanotubes (ACNTs) electrode was fabricated and was used to electrochemically determine nitrite. The thionine modified ACNTs electrode exhibited enhanced electrocatalytic behavior to the oxidation of nitrite. The electrochemical mechanism of the thionine/ACNTs electrode towards the oxidation of nitrite was discussed. The thionine modified ACNTs electrode exhibited fast response towards nitrite with a detection limit of 1.12 × 10−6 mol  L−1 and a linear range of 3 × 10−6 – 5 × 10−4 mol  L−1. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   

6.
Active surface-enhanced Raman scattering (SERS) silver nanoparticles substrate was prepared by multiple depositions of Ag nanoparticles on glass slides. The substrate is based on five depositions of Ag nanoparticles on 3-aminopropyl-trimetoxisilane (APTMS) modified glass slides, using APTMS sol–gel as linker molecules between silver layers. The SERS performance of the substrate was investigated using 4-aminobenzenethiol (4-ABT) as Raman probe molecule. The spectral analyses reveal a 4-ABT Raman signal enhancement of band intensities, which allow the detection of this compound in different solutions. The average SERS intensity decreases significantly in 4-ABT diluted solutions (from 10−4 to 10−6 mol L−1), but the compound may still be detected with high signal/noise ratio. The obtained results demonstrate that the Ag nanoparticles sensor has a great potential as SERS substrate.  相似文献   

7.
A simple silver particle-modified carbon paste electrode is proposed for the determination of low concentration levels of nitrite ions. The electrode consists of a carbon powder decorated with silver sub-micrometre particles (AgPs) and a hydrophobic ionic liquid trihexyltetradecylphosphonium chloride as a binder. It has been shown that AgPs exhibit a strong electrocatalytic effect on the nitrite oxidation. For optimal electroanalytical performance the electrode was conditioned via silver oxidation/reduction cycle. The electrode revealed a linear square-wave voltammetric response in a wide examined concentration range of 0.05 to 1.0 mmol L 1, limit of detection (LOD) of 3 μmol L 1 and excellent repeatability with RSD of 0.3%.  相似文献   

8.
The kinetics of the diazotization reaction of procaine in the presence of anionic micelles of sodium dodecyl sulfate (SDS) and cationic micelles of cetyltrimethyl ammonium bromide (CTAB), dodecyltrimethyl ammonium bromide (DDTAB) and tetradecyltrimethyl ammonium bromide (TDTAB) were carried out spectrophotometrically at λmax = 289 nm. The values of the pseudo first order rate constant were found to be linearly dependent upon the [NaNO2] in the concentration range of 1.0 × 10−3 mol dm−3 to 12.0 × 10−3 mol dm−3 in the presence of 2.0 × 10−2 mol dm−3 acetic acid. The concentration of procaine was kept constant at 6.50 × 10−5 mol dm−3. The addition of the cationic surfactants increased the reaction rate and gave plateau like curve. The addition of SDS micelles to the reactants initially increased the rate of reaction and gave maximum like curve. The maximum value of the rate constant was found to be 9.44 × 10−3 s−1 at 2.00 × 10−3 mol dm−3 SDS concentration. The azo coupling of diazonium ion with β-naphthol (at λmax = 488) nm was found to linearly dependent upon [ProcN2+] in the presence of both the cationic micelles (CTAB, DDTAB and TDTAB) and anionic micelles (SDS). Both the cationic and anionic micelles inhibited the rate of reactions. The kinetic results in the presence of micelles are explained using the Berezin pseudophase model. This model was also used to determine the kinetic parameters e.g. km, Ks from the observed results of the variation of rate constant at different [surfactants].  相似文献   

9.
The degradation of aqueous 2,3-dihydroxynaphthaline (2,3-DHN) under the influence of γ-ray was investigated under various experimental conditions. Using 2.5×10−5 mol L−1 2,3-DHN in aerated media (pH=6–6.8) an initial degradation yield, Gi-(2,3-DHN)=0.32 was obtained, whereas in solutions saturated with N2O the yield come to Gi-(2,3-DHN)=0.50.In airfree media the substrate decomposition was negligible. Possible reaction mechanisms are presented.Further, the rate constant, k(OH+2,3-DHN)=2.14×1010 L mol−1 s−1 was determined by competition reactions with PNDA.  相似文献   

10.
This paper presents the optimization of instrumental and solution parameters for determination of tamoxifen in urine and plasma and formulation by fast Fourier transform square wave voltammetry (SWV) using a gold microelectrode in flow-injection system. The samples are subjected by the same buffer solution and are injected in the flow-injection apparatus. By applying a novel square wave voltammetry method to perform as a sensitive method the voltamograms are recorded. The method used for determination of tamoxifen by measuring the changes in admittance voltammogram of a gold ultramicroelectrode (in 0.05 mol L?1 H3PO4 solution) caused by adsorption of the tamoxifen on the electrode surface. The best sensitivity was achieved using a frequency of 600 Hz and a medium composed of 0.05 mol L?1 phosphate buffers at pH 2.0. The best performance was obtained with the pH value of 2, pulse amplitude 25 mV, frequency 600 Hz, accumulation potential of ?100 mV and accumulation time of 0.5 s. Furthermore, signal-to-noise ratio has significantly increased by application of discrete fast Fourier transform (FFT) method, background subtraction and two-dimensional integration of the electrode response over a selected potential range and time window. Calibration plots are given for solutions containing 1.0 × 10?11 to 3.0 × 10?6 mol L?1 of tamoxifen. The detection limit is calculated to be 3.0 × 10?12 mol L?1 (~2 pg mL?1). The relative standard deviation at concentration 2.0 × 10?8 M is 6.1% for five reported measurements.  相似文献   

11.
A novel electrochemical platform was designed and prepared for simultaneous determination of p-acetaminophen (AMP) and p-aminophenol (AP) by combining the excellent conductivity and electrocatalytic activities of tetraaminophenyl porphyrin functionalized multi-walled carbon nanotubes (CNTs-CONH-TAPP) and gold nanoparticles (AuNPs). The as-synthesized CNTs-CONH-TAPP composites were characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and scanning electron microscope. The incisive oxidation current responses of AMP and AP at the modified electrode promised a sensitive and selective simultaneous determination of AMP and AP. Under optimized conditions, the peak currents were directly proportional to the concentrations of AMP and AP over the ranges of 4.5–500 μmol L−1 and 0.08–60 μmol L−1, respectively, and the limits of detection were 0.44 μmol L−1 for AMP and 0.025 μmol L−1 for AP(S/N = 3) respectively. The proposed modified electrode showed excellent selectivity, reproducibility and long-term stability and could be applied in simultaneous determination of p-acetaminophen and p-aminophenol in real samples.  相似文献   

12.
A new PVC membrane based strontium(II) ion-selective electrode has been constructed using acetophenone semicarbazone as a neutral carrier. The sensor exhibits a Nerstian response for strontium(II) ion over a wide concentration range 1.0 × 10−2–1.0 × 10−7 M with the slope of 29.4 mV/per decade. The limit of detection was 2.7 × 10−8 M. It was relatively fast response time (<10 s for concentration ⩾1.0 × 10−3 and <15 s for concentration of ⩾1.0 × 10−6 M) and can be used for 8 months without any considerable divergence in potentials. The proposed sensor revealed relatively good selectivity and high sensitivity for strontium(II) over a mono, di, trivalent cation and can be used in a pH range of 2.5–10.5. It was also successfully used as an indicator electrode in potentiometer titration and in the analysis of concentration in various real samples.  相似文献   

13.
A novel poly(p-xylenolsulfonephthalein) modified glassy carbon electrode was prepared for the simultaneous determination of ascorbic acid (AA), epinephrine (EP) and uric acid (UA). Cyclic voltammetric, chronoamperometric, and differential pulse voltammetric methods were used to investigate the modified electrode for the electrocatalytic oxidation of EP, AA, and UA in aqueous solutions. The separation of the oxidation peak potentials for AA–EP and EP–UA was about 200 and 130 mV, respectively. The calibration curves obtained for AA, EP, and UA were in the ranges of 10–1343, 2–390, and 0.1–560 μmol L−1, respectively. The detection limits (S/N = 3) were 4, 0.1, and 0.08 μmol L−1 for AA, EP and UA, respectively. The diffusion coefficient and the catalytic rate constant for the oxidation of EP at the modified electrode were calculated as 1.40(±0.10) × 10−4 cm2 s−1 and 1.06 × 103 mol−1 L s−1, respectively. The present method was applied to the determination of EP in pharmaceutical and urine samples, AA in commercially available vitamin C tablet, and EP plus UA in urine samples.  相似文献   

14.
A novel chitosan-carboxylated multiwall carbon nanotube modified glassy carbon electrode (MC/GCE) was developed to investigate the oxidation behavior of nitrite using cyclic voltammetry and differential pulse voltammetry modes. The electrochemical mechanism of the MC/GCE towards nitrite was discussed. The MC/GCE exhibited fast response towards nitrite with a detection limit of 1 × 10−7 mol l−1 and a linear range of 5 × 10−7–1 × 10−4 mol l−1. The possible interference from several common ions was tested. The proposed method was successfully applied in the detection of nitrite in real samples.  相似文献   

15.
The potentiometric response characteristics of zinc ion selective PVC-based membrane electrode employing 1,12,14-triaza-5,8-dioxo-3(4),9(10)-dibenzoyl-1,12,14-triene as an inophore was investigated. The proposed electrode exhibits a Nernstian behavior with a slope of 29.2 ± 0.4 mV per decade with a working concentration range of 1.3 × 10?7–1.0 × 10?1 mol L?1 and a detection limit of 1.0 × 10?8 mol L?1. The membrane having the composition as TDODBCPT:O-NPOE:PVC:OA; 7:57:30:6 wt.% exhibits the best results. It has a fast response time of 7 s and can be used for at least 100 days without any considerable divergence in potential. The proposed electrode show good discrimination of Zn2+ ion from diverse ions. The potential response remains constant over a pH range of 3.5–9.2. The electrode found well work under laboratory conditions. The proposed sensor directly used for determination of zinc ions in human hair sample, wastewater and an indicator electrode with EDTA titration.  相似文献   

16.
A sensitive electrochemical method for H2O2 determination was proposed with carboxyl functionalized graphene oxide (GO-COOH) as mimetic peroxidase and 3,3′,5,5′-tetramethylbenzidine (TMB) as substrate. GO-COOH exhibited intrinsic peroxidase-like activity that could catalyze the oxidation of TMB with H2O2. The generated product exhibited a sensitive second order derivative linear sweep voltammetric reduction peak at − 0.93 V (vs. Ag/AgCl) in Britton–Robinson buffer. Under the optimal conditions the reduction peak current was proportional to H2O2 concentration in the linear range from 0.006 to 0.8 μmol L 1 with the detection limit of 1.0 nmol L 1 (3σ). This proposed method was further applied to determine H2O2 content in fresh milk samples with satisfactory results.  相似文献   

17.
The bioelectrochemical oxidation of two polyaromatic hydrocarbons (PAH): anthracene (ANT) and pyrene (PYR), using horseradish peroxidase (HRP) resulting in the synthesis of photoactive polyaromatic quinones in organic media was studied. The electrochemical generation of hydrogen peroxide was compared with its direct addition in concentrations of up to 0.0012 mol L−1. In addition, three different chemical redox mediators were evaluated: ABTS, thionin and ortho-aminophenol. In a reaction medium containing 30% acetone and ABTS as mediator with a molar ratio mediator/PAH of 1:10, HRP attained the highest level of oxidation of PAH (1 × 10−3 mol L−1): ANT (94%) and PYR (91%), producing 9,10-anthraquinone and mainly 1,2 and 4,5-pyrenequinones, respectively.  相似文献   

18.
A simple, rapid and low-cost electroanalytical method is proposed for the determination of acetaminophen (ACP) and codeine (COD) at nanomolar levels in pharmaceutical and biological samples. The analytical procedure is based on a flow injection analysis system coupled to electrochemical detection, which was multiple pulse amperometry (FIA-MPA). Boron-doped diamond was used as the working electrode for electrochemical detection. The electrode was subjected to a cathodic pretreatment and was selected in this work due its good electrochemical performance. By applying the FIA-MPA method, after a number of optimization assays, the analgesics were simultaneously determined at excellent linear concentration ranges. The analytical curves ranged from 80 nmol L−1 to 100 µmol L−1 for ACP and from 50 nmol L−1 to 10 µmol L−1 for COD, and the obtained limits of detection were 30 nmol L−1 and 35 nmol L−1 for ACP and COD, respectively. The practical applicability of the electroanalytical method was evaluated from the ACP and COD determination in two sample matrices: commercial pharmaceutical samples and biological fluids. In the case of pharmaceutical formulation samples, the obtained results were statistically similar to those obtained using a reference chromatographic method. In addition, these drugs were simultaneously quantified in biological fluid samples of urine and human serum with excellent recovery percentages.  相似文献   

19.
The activity and stability of horseradish peroxidase (HRP) were investigated in a hydrophilic room temperature ionic liquid 1-butyl-3-methylimidazolium tetrafluroborate ([bmim][BF4]) by electrochemical methods. Although no detectable activity exhibited in anhydrous [bmim][BF4], HRP was active in the presence of a small amount of water (4.53%, v/v). And its activity can be improved by immobilization in agarose hydrogel. The immobilized HRP possesses excellent activity at 65 °C. It remained 80.2% of its initial activity after being immersed for 10.5 h in an aqueous mixture of [bmim][BF4] with some hydrogen peroxide (H2O2) under room temperature, implying extremely high stability. Moreover, the immobilized HRP was found to be very sensitive and stable in H2O-containing [bmim][BF4] for the detection of H2O2, with a wide linear range of 6.10 × 10−7 to 1.32 × 10−4 mol l−1 and low detection limit of 1.0 × 10−7 mol l−1.  相似文献   

20.
In this work, we present a new complete method using Surface Enhanced Raman Spectroscopy (SERS) and chemometrics for the qualitative and quantitative detection of pesticides by measuring the acetylcholinesterase (ACHE) activity. The Raman SERS is not only used for measuring the ACHE activity, but also for the direct detection of pesticides individually and for their identification. Gold nanoparticles (AuNPs) were used as dynamic SERS substrates for sensitive monitoring of ACHE activity in the presence of very low levels of organophosphate and carbamate pesticides, chemical warfare agents that are known to be ACHE inhibitors. The lowest detectable level for paraoxon was determined at 4.0 × 10−14 M and 1.9 × 10−9 M for carbaryl. The use of the enzyme allowed limits of detection for both pesticides that were much lower than the limits obtained by direct SERS analysis of the pesticides. The system shows a linear relationship between the intensity band at 639 cm−1 and pesticide concentration. These results suggest that this biosensor could be used in the future for the non-selective detection of all ACHE inhibitors at very low concentrations with possible identification of the inhibitor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号