首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Three strategies were investigated for the simultaneous separation and on-line preconcentration of charged and neutral hypolipidaemic drugs in micellar electrokinetic chromatography (MEKC). A background electrolyte (BGE) consisting of 20 mM ammonium bicarbonate buffer (pH 8.50) and 50 mM sodium dodecyl sulfate (SDS) was used for the separation and on-line preconcentration of the drugs. The efficiencies of sweeping, analyte focusing by micelle collapse (AFMC), and simultaneous field-amplified sample stacking (FASS) and sweeping, were compared for the preconcentration of eight hypolipidaemic drugs in different conductivity sample matrices. When compared with a hydrodynamic injection (5 s at 50 mbar, 0.51% of capillary volume to detection window) of drug mixture prepared in the separation BGE, improvements of detection sensitivity of 60-, 83-, and 80-fold were obtained with sweeping, AFMC and simultaneous FASS and sweeping, respectively, giving limits of detection (LODs) of 50, 36, and 38 μg/L, respectively. The studied techniques showed suitability for focusing different types of analytes having different values of retention factor (k). This is the first report for the separation of different types of hypolipidaemic drugs by capillary electrophoresis (CE). The three methods were validated then applied for the analysis of target analytes in wastewater samples from Hobart city.  相似文献   

2.
Heroin metabolites including morphine, codeine, and 6-acetylmorphine were determined by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI–sweep-MEKC). Liquid–liquid extraction was used for urine pretreatment. An uncoated fused silica capillary (Ld = 30 cm, 50 μm ID) was filled with phosphate buffer (50 mM, pH 2.5) containing 30% methanol, then high conductivity buffer (100 mM phosphate, 41.3 kPa for 18 s) was followed. Samples were injected electrokinetically (20 kV, 300 s). The sweeping and separation were performed at −25 kV using phosphate buffer (20 mM, pH 2.5) and 80 mM sodium dodecyl sulfate. The baseline separation was done within 10 min. During method validation, the calibration curves were linear over a range of 50–500 ng/mL (r ≧ 0.994). The RSD and RE values in intra-day and inter-day assays were all below 20%, which showed good precision and accuracy. Their detection limits were 10 ng/mL (S/N = 3). The optimized method was applied to determine real urine samples from addicts. These samples were confirmed by liquid chromatography/mass spectrometry.  相似文献   

3.
We describe the stacking and separation of d- and l-aspartic acid (Asp) by capillary electrophoresis (CE) with light-emitting diode-induced fluorescence detection (LEDIF). In the presence of cyanide, d- and l-Asp were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) to form fluorescent derivatives prior to CE-LEDIF. The separation of NDA-derivatized d- and l-Asp was accomplished using a discontinuous system - buffer vials contained a solution of 0.6% poly(ethylene oxide) (PEO), 150 mM sodium dodecyl sulfate (SDS), and 60 mM hydroxypropyl-β-cyclodextrin (Hp-β-CD), while a capillary was filled with a solution of 150 mM SDS and 60 mM Hp-β-CD. The role of PEO, Hp-β-CD, and SDS is to act as a concentrating media, as a chiral selector, and as a pseudostationary phase, respectively. This discontinuous system could be employed for the stacking of 600 nL of NDA-derivatized d- and l-Asp without the loss of chiral resolution. The stacking mechanism is mainly based on the difference in viscosity between sample zone and PEO as well as SDS sweeping. The limits of detection at signal-to-noise of 3 for d- and l-Asp were down to 2.4 and 2.5 × 10−10 M, respectively. Compared to normal sample injection volume (25 nL), this stacking approach provided a 100- and 110-fold improvement in the sensitivity of d- and l-Asp, respectively. This method was further applied for determining d- and l-Asp in cerebrospinal fluid, soymilk, and beer.  相似文献   

4.
Monitoring of trace impurities in electroplating bath is needed to meet EU requirements for WEEE and RoHS and for quality control of electrodeposits. Methods using IC and 100% aqueous CE buffer were found producing non-repeatable results attributed to interference of surfactants and major methanesulphonate anion. A new CE buffer containing 1.5 mM tetraethylenepentaamine, 3 mM 1,3,5-benzenetricarboxylic acid and 15 mM Tris in 20% (v/v) methanol at pH = 8.4 was shown to enhance the separation window, reduce interaction between buffer and bath constituents, and give satisfactory repeatability with baseline separation for 14 organic and inorganic anions within 14 min, good repeatability for migration time (0.32–0.57% RSD), satisfactory peak area and peak height (2.9–4.5 and 3–4.7% respectively), low detection limit (S/N = 2, 20–150 ppb), and wide working ranges (0.1–100 ppm). The CE buffer with 20% (v/v) methanol has demonstrated its capability for identifying anion impurities causing problem in aged tin bath and the use of only 10-fold dilution to produce reliable results for quality assessment in plating bath containing high surfactant additives.  相似文献   

5.
Microemulsion electrokinetic capillary chromatography (MEEKC) with sample stacking induced by reverse migrating pseudostationary phase (SRMP) technique in a suppressed electro-osmotic flow (EOF) strategy was investigated for analysing the new ultra-short hypnotic HIE-124 in mice serum. The proposed method utilized fused-silica capillary with a total length of 50 cm (effective length 40 cm), applied voltages for stacking and separation were 5.0 kV for 4.30 min and subsequently 25 kV, respectively, with a sample injection of 0.5 psi for 90 s. All the runs were carried out at 25 °C and detected at 213 nm. The optimum microemulsion background electrolyte (BGE) solution consisted of 0.8% (v/v) ethyl acetate, 6.6% (v/v) butan-2-ol, 1.0% (v/v) acetonitrile, 2.0% (w/v) sodium dodecyl sulfate (SDS), and 89.6 mL with 25 mM phosphate buffer pH 8. When this preconcentration technique was used, the sample stacking and the separation processes took place successively with changing the voltage with an intermediate polarity switching step. The proposed method was validated carefully with respect to high specificity of the method, good linearity (r = 0.9994), fair wide linear concentration range (66-1500 ng mL−1), limit of detection and quantitation were 21.6 and 65.5 ng mL−1, respectively. The mean relative standard deviation (RSD) of the results of intra- and inter-day precision and accuracy were less than 6.0%, and overall recovery higher than 95% of HIE-124 in mice serum. The developed method could be used for the trace analyses of HIE-124 in serum and was finally used for the pharmacokinetic study investigation of HIE-124 in mice serum.  相似文献   

6.
An on-line sample preconcentration method by two-step stacking i.e., sweeping and micelle to solvent stacking, in capillary zone electrophoresis (CZE) has been developed for the determination of strychnine and brucine in traditional Chinese herbal medicines. After experimental optimizations, the best separation was achieved by using 75 mM phosphate buffer (pH 2.5) with 30% methanol (v/v). Compared with normal CZE injection, 51- and 38-fold improvement in concentration sensitivity was achieved for strychnine and brucine, respectively. The calibration curve was linear in the range of 0.1–5.0 μg mL−1 for both strychnine and brucine, with the correlation coefficients of 0.9998 and 0.9997, respectively. The limits of detection (S/N = 3) for both alkaloids were 0.01 μg mL−1. The inter-day (n = 8) and intra-day (n = 5) reproducibilities expressed as the relative standard deviations for corrected peak area were less than 9.5%. The method was applied to determine strychnine and brucine in two Chinese herbal medicines, with recoveries ranging from 94.2% to 105.4%. The results indicated that the method is simple, rapid, reliable, and can be applied to determine strychnos alkaloids in traditional Chinese herbal medicines.  相似文献   

7.
We have employed a high‐sensitivity off‐line coupled with on‐line preconcentration method, cloud‐point extraction (CPE)/cation‐selective exhaustive injection (CSEI) and sweeping‐MEKC, for the analysis of malachite green. The variables that affect CPE were investigated. The optimal conditions were 250 g/L of Triton X‐100, 10% of Na2SO4 (w/v), heat‐assisted at 60°C for 20 min. We monitored the effects of several of the CSEI‐sweeping‐MEKC parameters – including the type of BGE, the concentrations of SDS, the injection length of the high‐conductivity buffer, and the injection time of the sample – to optimize the separation process. The optimal BGE was 50 mM citric acid (pH 2.2) containing 100 mM SDS. In addition, electrokinetic injection of the sample at 15 kV for 800 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancement for malachite green was 1.9×104 relative to CZE; the coefficients of determination exceeded 0.9928. The LOD, based on an S/N of 3:1, of CSEI‐sweeping‐MEKC was 0.87 ng/mL; in contrast, when using off‐line CPE/CSEI‐sweeping‐MEKC the sensitivity increased to 69.6 pg/mL. This proposed method was successfully applied to determine trace amounts of malachite green in fish water samples.  相似文献   

8.
Isabel López 《Talanta》2010,82(2):594-599
A fast method for mercury extraction from biological samples based on the use of HCl leaching plus different enzymatic hydrolysis (with and without mercury complexing agents), and the use of focussed ultrasounds (2-mm microtip) is here proposed. Total mercury content in several biological samples was determined by FI-ICP-MS using a carrier solution consisting of 0.1% (v/v) HCl, 0.1% (v/v) 2-mercaptoethanol, to avoid memory effect, and 0.15% (w/v) KCl. For mercury speciation a RP18 chromatographic column coupled to ICP-MS was used. A mobile phase consisting of 0.1% (v/v) formic acid, 0.1% (v/v) HFBA, 2% (v/v) methanol, and 0.02% (w/v) mM l-cysteine at pH 2.1 was used for chromatographic separation of the mercury species in the sample extracts. Extraction procedures were validated by using 50 mg of tuna fish tissue CRM-463 (2.85 ± 0.16 mg kg−1 for methylmercury). The recoveries obtained were 99 ± 3% and 93 ± 1% after acid leaching (HCl 7 M) and enzymatic extraction (15 mg protease type XIV in 2.5% (v/v) 2-mercaptoethanol), respectively. The optimal sonication conditions (5 min of exposure time and 40% of ultrasound amplitude) were applied to 5 mg of CRM-463 (88 ± 5%), 5 mg of mussel tissue (81 ± 11%) and to 2 mg of zebra fish embryos (90 ± 10%) obtaining good recoveries in all cases. Methylmecury was found to be the most abundant Hg specie in all samples. The developed method is simple and rapid (5 min sample treatment); it is suitable for very small samples and does not alter the original form of the mercury species. Thus, it is of special interest in those cases in which validation of the results may often be hampered by lack of sample availability.  相似文献   

9.
Lan Zhang  Jinfeng Chen  Yu He  Guonan Chen 《Talanta》2009,77(3):1002-2154
A simple, rapid and low-costing new mixed surfactant MEKC method has been developed for the analysis of five neutral anabolic steroids in this paper. It was found that the bile salt coupling with Triton X-100 was a suitable bi-micellar surfactant for the separation of these anabolic steroids with similar structure. The separation conditions were optimized in detail. The five natural and synthetic anabolic steroids, such as androstenedione (AD), 19-norandrostenedione (NAD), 1,4-androstadiene-3,17-dione (ADD), methandrostenolone (MA) and methyltestosterone (MT) were separated and detected in an alkaline buffer system (pH 9.0) containing 15 mM Britton-Robinson (BR) buffer, 50 mM sodium cholate (SC) and 0.1% (v/v) Triton X-100 with detection wavelength at 241 nm and 18 kV of separation voltage. Under the optimal conditions, five coexistence neutral steroids were completely separated within 12 min with the detection limits ranged from 0.20 to 0.51 μg/mL. This method was successfully used for detection and confirmation of the anabolic steroid methandrostenolone in methandrostenolone tablets and in the real human urine, GC-MS method was applied to confirm the free methandrostenolone existence in the urine sample in order to validate the reliability of MEKC method.  相似文献   

10.
Lihong Liu  Zhide Hu 《Talanta》2007,71(1):155-159
A simple, rapid, and accurate method for the separation and determination of alpinetin and cardamonin in Alpinia katsumadai Hayata was developed by combination of flow injection (FI)-micellar electrokinetic chromatography (MEKC) for the first time. The analysis was carried out using an unmodified fused-silica capillary (50 μm i.d.; total length 13.6 cm; effective length 10.3 cm) and direct ultraviolet (UV) detection at 214 nm. The sample throughput was 11-24 samples per hour using the background electrolyte (BGE) containing 4 mM sodium borate-8 mM NaH2PO4 (pH 8.1)-8 mM sodium dodecyl sulfate (SDS)-19% (v/v) ethanol. The repeatabilities (n = 4) reached relative standard deviation values (R.S.D.) of 3.0% and 2.5% for the peak areas and 2.5% and 3.1% for peak heights of alpinetin and cardamonin, respectively. Regression equations revealed linear relationships (r2: 0.9993-0.9994) between the peak area of each analyte and the concentration. Recoveries were in the range 90-92% and 99-105% for alpinetin and cardamonin, respectively.  相似文献   

11.
Kritsunankul O  Jakmunee J 《Talanta》2011,84(5):1342-1349
Flow injection on-line dialysis was developed for sample pretreatment prior to the simultaneous determination of some food additives by high performance liquid chromatography (FID-HPLC). A liquid sample or mixed standard solution (900 μL) was injected into a donor stream (5%, w/v, sucrose) of FID system and was pushed further through a dialysis cell, while an acceptor solution (0.025 mol L−1 phosphate buffer, pH 3.75) was held in the opposite side of the dialysis membrane. The dialysate was then flowed to an injection loop of the HPLC valve, where it was further injected into the HPLC system and analyzed under isocratic reverse-phase HPLC conditions and UV detection (230 nm). The order of elution of five food additives was acesulfame-K, saccharin, caffeine, benzoic acid and sorbic acid, respectively, with the analysis time of 14 min. On-line dialysis and HPLC analysis could be performed in parallel, providing sample throughput of 4.3 h−1. Dialysis efficiencies of five food additives were in ranges of 5-11%. Linear calibration graphs were in ranges of 10-100 mg L−1 for acesulfame-K and saccharin, 10-250 mg L−1 for benzoic acid and 10-500 mg L−1 for caffeine and sorbic acid. Good precisions (RSD < 5%) for all the additives were obtained. The proposed system was applied to soft drink and other liquid food samples. Acceptable percentage recoveries could be obtained by appropriate dilution of the sample before injecting into the system. The developed system has advantages of high degrees of automation for sample pretreatment, i.e., on-line sample separation and dilution and low consumption of chemicals and materials.  相似文献   

12.
This work reports a fast and simple liquid chromatographic method for the simultaneous determination of five banned fat-soluble synthetic colorants, namely Sudan I-IV and Para-Red, in spice samples. The analytes were successfully separated isocratically in less than 5 min on the new narrow bore monolithic column, FastGradient® Chromolith (50 mm × 2.0 mm i.d.) using a mobile phase of 0.1% (v/v) HCOOH/acetonitrile (35/65%, v/v) at a flow rate of 1.5 mL min−1. All colorants were detected at 506 nm. The main parameters (mobile phase composition, flow rate, injection volume) affecting the separation were studied. The proposed method was thoroughly validated in terms of linearity, LODs, precision and accuracy. The method was applied to the determination of the studied azo-dyes in various spices (paprika, chilli and mixed spice powders) after ultrasound-assisted extraction. Satisfactory recoveries, ranging from 92% to 109% were obtained.  相似文献   

13.
A novel method of microemulsion electrokinetic chromatography (MEEKC) coupled with hollow fiber-liquid phase microextraction (HF-LPME) was developed for determination of six aromatic amines including 4-methylaniline, 3-nitroaniline, 2,4-dimethylaniline, 4-chloroaniline, 3,4-dichloraniline and 4-aminobiphenyl. Baseline separation of six aromatic amines was achieved within 8 min by using the microemulsion buffer containing a 10 mM borate buffer at pH 9.0, 0.8% (v/v) ethyl acetate as oil droplets, 60 mM sodium cholate as surfactant, 5.0% (v/v) 1-butanol as co-surfactant. The influence factors relevant to the HF-LPME process were systemically investigated. The obtained enrichment factors were ranged between 70 and 157 in a 30 min extraction time, and the limits of detection ranged between 0.0021 and 0.0048 μg/mL. This purposed method was successfully applied for the analysis of aromatic amines in water sample and the recoveries were ranged from 87.2% to 99.8%.  相似文献   

14.
The feasibility of a microcolumn electrophoresis technique was investigated with a 100 mm length, 2 mm I.D. fused-silica microcolumn packed with uniform quartz microncrystals prepared by hydrothermal synthesis. To evaluate the separation technique, tryptophan, phenylalanine and tyrosine were primarily separated by the microcolumn electrophoresis and detected at 216 nm without derivatization by an ordinary spectrophotometer. The separation conditions of the amino acids were optimized. With 1.5 mmol/L disodium phosphate buffer solution (pH 11.5) containing 25% (v/v) methanol and 10% (v/v) acetonitrile, the three amino acids were separated and the separation efficiency of tryptophan was 4.5 × 104 plates/m. The limits of detection were 0.035, 0.22 and 0.20 μmol/L, respectively. The sample capacity of the electrophoretic microcolumn achieved 35 μL. The proposed method was used to determine these amino acids in compound amino acid injection samples without derivatization. For the simplicity and portability of the microcolumn electrophoresis, it is studied as one of the high-performance separation techniques for an in situ and real-time electrokinetic flow analysis system. For its high detection sensitivity and large sample capacity, it can be developed for preparative electrophoresis.  相似文献   

15.
A new CE method has been developed for the simultaneous separation of a group of parent phthalates. Due to the neutral character of these compounds, the addition of several bile salts as surfactants (sodium cholate (SC), sodium deoxycholate (SDC), sodium taurodeoxycholate (STDC), sodium taurocholate (STC)) to the separation buffer was explored showing the high potential of SDC as pseudostationary phase. However, the resolution of all the phthalates was not achieved when employing only this bile salt as additive, being necessary the addition of neutral cyclodextrins (CD) and organic modifiers to the separation media. The optimized cyclodextrin modified micellar electrokinetic chromatography (CD-MEKC) method consisted of the employ of a background electrolyte (BGE) containing 25 mM β-CD-100 mM SDC in a 100 mM borate buffer (pH 8.5) with a 10% (v/v) of acetonitrile, employing a voltage of 30 kV and a temperature of 25 °C. This separation medium enabled the total resolution of eight compounds and the partial resolution of two of the analytes, di-n-octyl phthalate (DNOP) and diethyl hexyl phthalate (DEHP) (Rs ~ 0.8), in only 12 min. The analytical characteristics of the developed method were studied showing their suitability for the determination of these compounds in commercial perfumes. In all the analyzed perfumes the most common phthalate was diethyl phthalate (DEP) that appeared in ten of the fifteen analyzed products. Also dimethyl phthalate (DMP), diallyl phthalate (DAP), dicyclohexyl phthalate (DCP), and di-n-pentyl phthalate (DNPP) were found in some of the analyzed samples.  相似文献   

16.
A new analytical procedure for determination of inorganic antimony and speciation of antimony(III) and antimony(V) is presented. For this purpose, a software-controlled time-based multisyringe flow injection system, which contains a multisyringe burette provided with a multi-port selection valve, was developed. Hydride generation-atomic fluorescence spectrometry was used as a detection technique. A 0.3% (w/v) reducing sodium tetrahydroborate solution, hydrochloric acid (2 M), an antimony solution and a pre-reducing solution of 10% (w/v) KI and 0.3% (w/v) ascorbic acid are dispensed simultaneously into a gas-liquid separation cell with further propulsion of the reaction product into the flame of an atomic fluorescence spectrometer using argon flow. A hydrogen flow was employed to support the flame.The linear range and the detection limit (3sb/S) of the proposed technique were 0.2-5.6 μg l−1 and 0.08 μg l−1, respectively. A sample throughput of 18 samples per hour (corresponding to 80 injections per hour) was achieved. The relative standard deviation for 18 independent measurements was 4.6%. This technique was validated by means of reference solid and water materials with good agreement with the certified values. Satisfactory results for speciation of Sb(III) and Sb(V) by means of the developed technique were obtained.  相似文献   

17.
Zhou L  Wang W  Wang S  Hui Y  Luo Z  Hu Z 《Analytica chimica acta》2008,611(2):212-219
A novel method based on separation by nonaqueous capillary electrophoresis (NACE) combined with laser-induced fluorescence (LIF) detection was developed and compared with classic aqueous modes of electrophoresis in terms of resolution of solutes of interest and sensitivity of the fluorescence detection. Catecholamines derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) were chosen as test analytes for their subtle fluorescence properties. In aqueous systems, capillary zone electrophoresis (CZE) was not suitable for the analysis of test analytes due to complete fluorescence quenching of NBD-labeled catecholamines in neat aqueous buffer. The addition of micelles or microemulsion droplets into aqueous running buffer can dramatically improve the fluorescence response, and the enhancement seems to be comparable for micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC). As another alternative, NACE separation was advantageous when performing the analysis under the optimum separation condition of 20 mM sodium tetraborate, 20 mM sodium dodecyl sulfate (SDS), 0.1% (v/v) glacial acetic acid, 20% (v/v) acetonitrile (ACN) in methanol medium after derivatization in ACN/dimethyl sulfoxide (DMSO) (3:2, v/v) mixed aprotic solvents containing 20 mM ammonium acetate. Compared with derivatization and separation in aqueous media, NACE-LIF procedure was proved to be superior, providing high sensitivity and short migration time. Under respective optimum conditions, the NACE procedure offered the best fluorescence response with 5-24 folds enhancement for catecholamines compared to aqueous procedures. In addition, the mechanisms of derivatization and separation in nonaqueous media were elucidated in detail.  相似文献   

18.
This paper describes a sweeping–micellar electrokinetic chromatography (sweeping–MEKC) technique for the determination of seven benzodiazepines, using, as sweeping carriers, the ionic liquid-type cationic surfactants 1-cetyl-3-methylimidazolium bromide (C16MIMBr) and N-cetyl-N-methylpyrrolidinium bromide (C16MPYB). These surfactants resemble the commonly employed cationic surfactant cetyltrimethylammonium bromide (CTAB), but they provide different separation efficiencies. We optimized the separation and sweeping conditions, including the pH, the concentrations of organic modifier and surfactant, and the sample injection volume. Adding C16MIMBr or C16MPYB to the background electrolyte enhanced the separation efficiency and detection sensitivity during the sweeping–MEKC analyses of the benzodiazepines. C16MIMBr enhanced the sensitivity for each benzodiazepine 31–59-fold; C16MPYB, 86–165-fold. In the presence of C16MPYB, the limits of detection for the seven analytes ranged from 4.68 to 9.75 ng/mL. We adopted the sweeping–MEKC conditions optimized for C16MPYB to satisfactorily analyze a human urine sample spiked with the seven benzodiazepines. To minimize the matrix effects, we subjected this urine sample to off-line solid phase extraction (SPE) prior to analysis. The recoveries of the analytes after SPE were satisfactory (ca. 77.0–88.3%). Our experimental results reveal that the cationic surfactant C16MPYB exhibits superior sweeping power relative to those of C16MIMBr and CTAB and that it can be applied in sweeping–MEKC analyses for the on-line concentrating and analyzing of benzodiazepines present in real samples at nanogram-per-milliliter concentrations.  相似文献   

19.
A field-amplified sample injection (FASI) technique was elaborated for fast and sensitive determination of selected central nervous system drugs in human urine samples. Factors affecting the sensitivity enhancement, such as background electrolyte (BGE) and the analytical matrix composition were optimized and discussed. Pseudo-isotachophoresis (p-ITP) mechanism contribution in preconcentration mechanism was discussed. All separations were performed in uncoated fused silica capillaries 50 μm × 57 cm at 22 kV. The optimized analytical matrix was composed of 0.25 mM HCOOH in 90% (v/v) methanol, while BGE contained 45 mM TRIS/HCl (pH 2.20). The head-column injection was performed in 0.25 mM HCOOH water solution (3 s, 3.45 kPa). Sample was introduced into the capillary by electrokinetic injection (70 s, 5 kV) followed by short BGE plug (3 s, 3.45 kPa). Seven psychiatric drugs (olanzapine, prochlorperazine dimaleate, trifluoperazine dihydrochloride, perphenazine, promazine hydrochloride, clomipramine hydrochloride, and chlorprothixene hydrochloride) were separated in about 6 min. The elaborated method was additionally supported with dispersive liquid–liquid microextraction (DLLME) technique which in summary with FASI provided about 8000–13,000-fold sensitivity enhancement in comparison to the capillary zone electrophoresis (CZE) method with standard hydrodynamic injection (5 s, 3.45 kPa).  相似文献   

20.
Two on-line sample concentration techniques, sample stacking and sweeping under pH-suppressed electroosmotic flow, were evaluated in microemulsion electrokinetic chromatography. The concept of stacking with anion selective electrokinetic injection and a water plug in a reverse-migrating microemulsion (SASIW-RMME) was brought forward in this article. Six flavonoids were concentrated using a microemulsion consisting of 80 mM sodium dodecyl sulfate, 1.2% (v/v) ethyl acetate, 0.6% (v/v) 1-butanol, 10% acetonitrile (v/v) and 50 mM phosphoric acid (pH* 1.8). Significant detector response improvements were achieved. The limits of detection were in the low ng/ml level. Finally, the sample of Fructus aurantii Immaturus was analyzed using sweeping technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号