首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wang J  Zheng G  Yang L  Sun W 《The Analyst》2001,126(4):438-440
A capillary electrophoresis method was developed for the enantioseparation of epoxide compounds. Sulfated beta-cyclodextrin was employed as a chiral selector. Phosphate-triethanolamine buffer showed a chiral separation effect when employing charged sulfated beta-cyclodextrin. The effect of pH, triethanolamine concentration and sulfated beta-cyclodextrin concentration on the resolution was studied. Methanol was tested as an organic modifier. Several other epoxides were successfully separated by the proposed method.  相似文献   

2.
Chen J  Du Y  Zhu F  Chen B 《Journal of chromatography. A》2010,1217(45):7158-7163
Several chiral reagents including cyclodextrins (CDs) and derivatives, crown ethers, proteins, chiral surfactants and polymers have been involved in dual selector systems for enantioseparation of a series of chiral compounds by capillary electrophoresis (CE). In comparison to the chiral reagents above-mentioned, there is no report concerning the use of polysaccharides in dual chiral CE system. In this paper we first investigate the enantioselectivity of polysaccharide-based dual selector systems towards some chiral drugs. During our recent work, glycogen belonging to the class of branched polysaccharides has been used as a novel chiral selector in CE. In this study, three glycogen-based dual chiral CE systems have been established for enantiomeric separations of several racemic basic drugs consisting of duloxetine, cetirizine, citalopram, sulconazole, laudanosine, amlodipine, propranolol, atenolol and nefopam. These three dual systems combined glycogen (neutral polysaccharide) with chondroitin sulfate A (CSA, ionic polysaccharide), β-CD and HP-β-CD, respectively. It was found that the dual system of glycogen/CSA exhibited good enantioselective properties toward the tested drugs. More importantly, compared to the single selector systems, synergistic effect was observed when glycogen was used with CSA for most of the analytes. This indicated the enhancement of enantioseparation observed for these analytes in glycogen/CSA system might be due to some favorable interaction effects between glycogen and CSA. Moreover, in order to evaluate the stereoselectivity of glycogen/CSA, the influences of buffer pH and selector concentration on enantioseparation of the studied drugs were also investigated.  相似文献   

3.
In capillary electrophoresis (CE), separation of enantiomers of a chiral compound can be achieved through the chiral interactions and/or complex formation between the chiral selector and the enantiomeric analytes on leaving their diastereomeric forms with different stability constants and hence different mobilities. A great number of chiral selectors have been employed in CE and among them macrocyclic antibiotics exhibited excellent enantioselective properties towards a wide number of racemic compounds. The use of azithromycin (AZM) as a chiral selector has not been reported previously. This work reports the use of AZM as a chiral selector for the enantiomeric separations of five chiral drugs and one amino acid (tryptophan) in CE. The enantioseparation is carried out using polar organic mixtures of acetonitrile (ACN), methanol (MeOH), acetic acid and triethylamine as run buffer. The influences of the chiral selector concentration, ACN/MeOH ratio, applied voltage and capillary temperature on enantioseparation are investigated. The results show that AZM is a viable chiral selector in CE for the enantioseparation of the type of chiral drugs investigated.  相似文献   

4.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes.  相似文献   

5.
分别以2种天然环糊精(β、γ-环糊精)、2种常用的电中性环糊精衍生物(羟丙基-β-环糊精、二甲基-β-环糊精)和3种新型荷电环糊精衍生物(高取代磺酸基α、β、γ-环糊精)作为毛细管区带电泳手性添加剂,研究了环糊精的类型对6种手性药物对映体分离的影响.2种天然环糊精对所研究的手性药物均无手性识别能力,而环糊精经过衍生化后手性识别能力得到了很大的提髙,尤其是高取代磺酸基β-环糊精使6种手性药物均得到了基线分离.还考察了缓冲溶液的pH值和有机添加剂对手性分离的影响.  相似文献   

6.
Forty-one chiral sulfoxides and sulfinate esters were separated using sulfated beta-cyclodextrin and carboxymethyl beta-cyclodextrin as chiral selectors. Binding constants of some analytes to both chiral selectors were measured in order to examine and help explain the observed migration behavior and enantioselectivity trends. Overall, sulfated beta-cyclodextrin separated a greater number of compounds, and had better separating capabilities than did carboxymethyl beta-cyclodextrin for these analytes. This was true even though all of the analytes showed much stronger binding to carboxymethyl beta-cyclodextrin than to sulfated beta-cyclodextrin. General procedures to optimize the separation, by varying pH, selector concentration, and organic modifier concentration were examined and discussed. Chiral selector concentration had the greatest effect on enantioseparation, with higher concentrations of selector giving better peak-to-peak separations. Organic modifier had an adverse affect on resolution, with increasing amounts giving lower mobility differences. Lastly, pH had only a minimal effect on separation.  相似文献   

7.
A capillary electrophoretic method for the enantioseparation of ofloxacin and its five related substances (potential impurities, indicated as impurities B–F) was developed using β‐cyclodextrin derivatives as chiral selectors. To our knowledge, there are no previous studies about using capillary electrophoresis for the separation of impurities B–D. Six β‐cyclodextrin derivatives including cationic (piperidine‐ and cyclohexylamine‐), neutral (dimethyl‐ and hydroxypropyl‐), and anionic (carboxymethyl‐ and sulfated‐) β‐cyclodextrin derivatives were tested and operational parameters such as buffer pH and concentration of β‐cyclodextrin derivatives were investigated. The best resolutions were all obtained with anionic β‐cyclodextrin derivatives: ofloxacin, impurities C–F could be best resolved with carboxymethyl‐β‐cyclodextrin at satisfactory resolutions of 8.27, 9.98, 5.92, 8.49 and 6.78, respectively, while for impurity B, a particularly impressive resolution value, up to 21.38, was observed using sulfated‐β‐cyclodextrin. The enhancement of enantioseparation observed for the tested analytes using anionic β‐cyclodextrin derivatives might be due to some favorable interaction between selectors and analytes. Given the fact that the selection of chiral selector depends on the structures of analytes, with the help of structural similarities and differences of the analytes, the structure–separation relationship was further discussed.  相似文献   

8.
To improve resolution power of chiral selector and enantiomeric peak efficiency in CE, single isomer negatively charged β‐CD derivatives, mono(6‐deoxy‐6‐sulfoethylthio)‐β‐CD (SET‐β‐CD) bearing one negative charge and mono[6‐deoxy‐6‐(6‐sulfooxy‐5,5‐bis‐sulfooxymethyl)hexylthio]‐β‐CD (SMHT‐β‐CD) carrying three negative charges, were synthesized. The structure of these two β‐CD derivatives was confirmed by 1H NMR and MS. SET‐β‐CD and SMHT‐β‐CD successfully resolved the enantiomers of several basic model compounds. SMHT‐β‐CD provided for a significantly greater enantioseparation than SET‐β‐CD at lower concentrations. This appears to be due to the higher binding affinity of SMHT‐β‐CD to the model compounds and the wider separation window resulting from an increased countercurrent mobility of the selector. Overall, the new chiral selectors provided enantioseparations with high peak efficiency while avoiding peak distortion due to polydispersive and electrodispersive effects. The information obtained from an apparent binding constant study suggested that the enantioseparation of the model compounds followed the predictions of charged resolving agent migration model and that the observed degree of enantioseparation difference were due to the magnitude of differences in both enantiomer‐chiral selector binding affinities (ΔK) and the mobilities of the complexed enantiomers (Δμc).  相似文献   

9.
In this study, diamino moiety functionalized silica nanoparticles with the size of 118 ± 12 nm were successfully synthesized and directly introduced into a chiral capillary electrophoresis system to improve the enantioseparation of 9‐fluorenyl methoxycarbonyl derivatized amino acids using norvancomycin as chiral selector. Under acidic background electrolyte conditions, functional silica nanoparticles can be readily adsorbed onto the inner surface of bare silica capillary column through electrostatic interaction to form a dynamic coating, resulting in a reversed anodic electro‐osmotic flow (i.e. from cathode to anode). As expected, chiral amino acid derivatives (usually negatively charged) can be rapidly separated under co‐electro‐osmotic flow conditions in the current separation system. Furthermore, the column performance and detection sensitivity for the enantioseparation were also obviously improved because the adsorption of chiral selector of norvancomycin to the capillary wall was greatly suppressed. Some important factors influencing the separation, such as the coating thickness, background electrolyte concentration, functional silica nanoparticles concentration, and the organic modifier were also investigated and the optimized separation conditions were obtained.  相似文献   

10.
Liao WS  Lin CH  Chen CY  Kuo CM  Liu YC  Wu JC  Lin CE 《Electrophoresis》2007,28(21):3922-3929
Enantioseparations of five chiral phenothiazines in CD-modified CZE using the single isomer sulfate-substituted beta-CD (heptakis(2,3-dihydroxy-6-O-sulfo)-beta-CD, SI-S-beta-CD) and dual CD systems consisting of SI-S-beta-CD and a neutral CD as chiral selectors in a citrate buffer at pH 3.0 were investigated. The results indicate that SI-S-beta-CD is an excellent chiral selector for enantioseparation of promethazine. The enantiomers of trimeprazine were well separated, while those of ethopropazine could also be baseline-resolved with SI-S-beta-CD. With dual CD systems, especially with hydroxypropyl-beta-CD (HP-beta-CD) as neutral CD, the enantioselectivity of thioridazine and ethopropazine was considerably enhanced. Effective enantioseparation of phenothiazines, except for methotrimeprazine, could thus be favorably and simultaneously achieved. Moreover, reversal of the enantiomer migration order of ethopropazine and thioridazine occurred by varying the concentration of gamma-CD in the presence of SI-S-beta-CD. These phenomena may be attributable to the opposite effects of sulfated beta-CD and gamma-CD on the mobility of the enantiomers of ethopropazine and of thioridazine. Comparative studies on the enantioseparations of phenothiazines with single CD and dual CD systems containing SI-S-beta-CD and randomly sulfate-substituted beta-CD (MI-S-beta-CD) were made.  相似文献   

11.
La S  Ahn S  Kim JH  Goto J  Choi OK  Kim KR 《Electrophoresis》2002,23(24):4123-4131
Simultaneous enantioseparations of 15 racemic aromatic amino acids and L-mimosine for their chiral discrimination were achieved by neutral selector-modified capillary electrophoresis (CE) and by charged selector-modified CE. Among the diverse cyclodextrins (CDs) examined, hydroxypropyl (HP)-alpha-CD as the neutral selector and highly sulfated (HS)-gamma-CD as the charged selector provided best chiral environments of different enantioselectivities. Fairly good enantiomeric resolutions were achieved with the HP-alpha-CD mode except for racemic 6-hydroxy-3,4-dihydroxyphenylalanine, threo-3,4-dihydroxyphenylserine and homophenylalanine while high-resolution separations of all the enantiomeric pairs were achieved in the HS-gamma-CD mode except that L-mimosine was not detected and a partial resolution (0.6) for threo-3,4-dihydroxyphenylserine enantiomers. Relative migration times to that of internal standard under the respective optimum conditions were characteristic of each enantiomer with good precision (% RSD: 0.7-3.8), thereby enabling to cross-check the chemical identification of aromatic amino acids and also their chiralities. The method linearity was found to be adequate (r> 0.99) for the chiral assay of the aromatic amino acids investigated. When applied to extracts of three plant seeds, nonprotein amino acids such as L-mimosine (42 nug/g) from Mimosa pudica Linné, and L-3,4-dihydroxyphenylalanine (268 nug/g) from Vicia faba were positively detected along with L-tryptophan, L-phenylalanine and L-tyrosine.  相似文献   

12.
Various chiral selectors have been employed in CE and among them linear polysaccharides exhibited powerful enantioselective properties. Different from linear polysaccharides, the use of branched polysaccharides as chiral selectors in CE has not been reported previously. In this study glycogen belonging to the class of branched polysaccharides was used as a novel chiral selector for the enantiomeric separations for the first time. Since glycogen is electrically neutral, the method is applicable to ionic compounds. Eighteen chiral compounds including 12 basic drugs and six acidic drugs have been tested to demonstrate the potential of this chiral selector. BGE and selector concentrations and buffer pH were systematically optimized in order to obtain successful chiral separations. Among the tested compounds, the enantiomers of ibuprofen, which is an acidic drug, were successfully recognized by 3.0% w/v glycogen with 90 mM Tris‐H3PO4 buffer (pH 7.0). The enantiomers of basic drugs such as citalopram, cetirizine and nefopam were also baseline‐resolved with 50 mM Tris‐H3PO4 buffer (pH 3.0) containing 3.0% glycogen. Amlodipine belonging to basic compound only gave partial enantioseparation under the above‐mentioned condition.  相似文献   

13.
Tang W  Muderawan IW  Ong TT  Ng SC 《Electrophoresis》2005,26(16):3125-3133
A novel single-isomer positively charged beta-cyclodextrin (beta-CD), mono-6(A)-butylammonium-6(A)-deoxy-beta-cyclodextrin tosylate (BuAM-beta-CD), has been synthesized, characterized, and used for the enantioseparations of alpha-hydroxy acids, carboxylic acids, and ampholytic analytes by capillary electrophoresis in acidic aqueous background electrolytes. The effective mobilities of all studied analytes decreased with increasing concentration of CD. Satisfactory resolutions were obtained for alpha-hydroxy acids over a wide range of chiral selector concentration. The optimum CD concentration was lower than 5 mM for the carboxylic acids, while higher than 20 mM for alpha-hydroxy acids. Inclusion complexation in combination with ion pair interaction seemed to account for the chiral discrimination process. The hydrogen bonding may provide secondary contribution for the chiral resolution of alpha-hydroxy acids. In addition, BuAM-beta-CD was further proved to be an effective chiral selector for anionic analytes by the baseline enantioseparation of a six-acid mixture within 20 min.  相似文献   

14.
A method was developed for the enantioseparation of ofloxacin, a member of the fluoroquinolones, using an anionic cyclodextrin-derivative with or without combination with a neutral cyclodextrin-derivative, as the chiral selector (s) in an electrokinetic chromatography system. The best results were obtained with 0.35 mM sulfated beta-cyclodextrin dissolved in a 50 mM phosphate buffer, pH 2.5, and at 15 degrees C. Under these conditions, a resolution of 2 was readily achieved. Furthermore, under adequate separation conditions, studies were performed in order to assess possible in vitro and in vivo enantioconversion of levofloxacin. The current method allows detection of 2 microg R-(+)-ofloxacine/mL diluted urine without the necessity of sample cleanup.  相似文献   

15.
A novel positively charged single-isomer of β-cyclodextrin, mono-6-deoxy-6-(3R,4R-dihydroxypyrrolidine)-β-CD chloride (dhypy-CDCl), was synthesized and employed as a chiral selector for the first time in capillary electrophoresis (CE) for the enantioseparation of anionic and ampholytic acids. The effects of the running buffer pH, chiral selector concentration, analyte structure and organic modifier on the enantioseparation were studied in detail. The chiral selectivity and resolution for most of the studied analytes decreased as the buffer pH increased in the range of 6.0–9.0. Increasing selector concentration led to decreased effective mobility, increased chiral selectivity and resolution for most of the studied analytes. Moreover, the hydroxyl groups located on the dihydroxypyrrolidine substituent of the dhypy-CDCl could have influence on the chiral separation.  相似文献   

16.
A chiral selector, di-n-amyl L-tartrate-boric acid complex, was in situ synthesized by the reaction of di-n-amyl L-tartrate with boric acid in a nonaqueous background electrolyte (BGE) using methanol as the medium. And a new method of chiral nonaqueous capillary electrophoresis (NACE) was developed with the complex as the chiral selector. It has been demonstrated that the chiral selector is suitable for the enantioseparation of some β-blockers and β-agonists in NACE. Some chiral analytes that could not be resolved in aqueous microemulsion electrokinetic chromatography (MEEKC) with the same chiral selector obtained baseline resolutions in the NACE system. The enantioseparation mechanism was considered to be ion-pair principle and the nonaqueous system was more favorable for the ion-pair formation which is quite useful for the chiral recognition. The addition of a proper concentration of triethylamine into the BGE to control the apparent pH (pH*) enhanced the enantiomeric discrimination. In order to achieve a good enantioseparation, the effects of di-n-amyl L-tartrate and boric acid concentration, triethylamine concentration, applied voltage, as well as capillary length were investigated. Under the optimum conditions, all of the tested chiral analytes including six β-blockers and five β-agonists were baseline resolved.  相似文献   

17.
The enantiomeric separation of 37 clinically used racemic basic drugs among 50 drugs was achieved using sulfated β-cyclodextrin (S-β-CD) as chiral selector at pH2.5 and in the reversed polarity mode. The results obtained in this study were different from the one obtained using neutral β-CD and its derivatives as chiral selectors. Using S-β-CD as chiral selector did not require the presence of the substructure 4H to achieve chiral separation as observed with β-Cyclodextrin (β-CD) and its derivatives since among the 37 separated drugs only 7 possess the 4H substructure. The chiral discrimination depends on the appropriate interaction between the analyte and the sulfated β-cyclodextrin.  相似文献   

18.
Wu YS  Lee HK  Li SF 《Electrophoresis》2000,21(8):1611-1619
Enantiomeric separation of two triazole fungicides, triadimefon and triadimenol, was investigated in sulfated beta-cyclodextrin (sulfated beta-CD)-mediated capillary electrophoresis (CE) systems. It was found that, at pH 2-4, sulfated beta-CD exhibited strong chiral recognition towards both triadimefon and triadimenol. The enantiorecognition was believed to result from the multiple interactions between sulfated beta-CD and the analytes, which included inclusion effect, electrostatic interaction, and hydrogen bonding. Under optimal conditions (phosphate buffer with 2% sulfated beta-CD, pH 2.5), simultaneous resolution of all chiral isomers of triadimefon and triadimenol was achieved in less than half an hour. In conjunction with solvent extraction and subsequent enrichment by solid-phase extraction (SPE), this new enantioseparation method was applied successfully in the study of stereoselectivity associated with the biotransformation of triadimefon to triadimenol by soil microorganisms. The present methodology was superior to the commonly adopted chiral gas chromatography (GC) approach in that a very mild procedure was involved from sample extraction to the ultimate chiral separation. Thus, the disturbance of the enantiomeric distribution patterns of the original soil samples by heat stress was an unlikely scenario. Furthermore, it was discovered that, owing to the unique selectivity of the present separation strategy, there was virtually no interference from the soil matrix, which led to improvements in both sensitivity and selectivity in real sample determination.  相似文献   

19.
The enantiomeric resolution of N-t-butyloxycarbonyl (N-t-Boc) amino acids D/L isomers by reversed-phase HPLC was investigated using cyclodextrins (CD's) as chiral selectors for the mobile phase. The use of a low pH (pH<4) for the mobile phase enabled the enantioseparation of N-t-Boc amino acids. The opposite elution order of D/L isomers was observed when hydroxypropyl-derivatized beta-CD was used instead of native beta-CD. A computer simulation of the enantioseparation showed that the ratio of the retention factors of the chiral selector and the sample determined the elution order and the resolution. When the retention factor of the chiral selector is smaller than that of the sample, an isomer having larger complex formation constant eluted faster. However, when the chiral selector had a larger retention factor than the sample, an opposite elution order of the isomers was obtained. The large difference in the retention factors between the chiral selector and the sample led to good enantiomeric separation.  相似文献   

20.
Enantioseparation of N-tert.-butyloxycarbonyl amino acids (N-t-Boc-Aas) with teicoplanin chiral selector was performed in two different separation systems: A teicoplanin-based chiral stationary phase (CSP-TE) was used in reversed-phase HPLC, and the same chiral selector (CS) was added into a background electrolyte (BGE) in HPCE. The enantioselective interaction with the same CSP/CS can be influenced by several factors, such as mobile phase/background electrolyte composition: the buffer concentration, pH, the CS concentration, the presence of organic modifiers. In addition, the charge of the chiral selector related to the charge of the analyte and to EOF are important variables in CE. The effect of these parameters on enantioselectivity and enantioseparation of selected N-t-Boc-Aas was studied. The presence of a sufficient concentration (1% solution) of a triethylamine acetate buffer in the mobile phase was shown to be essential for enantioseparation of these blocked amino acids in HPLC. A certain concentration of teicoplanin aggregates (along with teicoplanin molecules) in the BGE is required to obtain enantioseparation of N-t-Boc-Aas in HPCE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号