首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mecker LC  Filla LA  Martin RS 《Electroanalysis》2010,22(19):2141-2146
In this communication, we demonstrate that a carbon ink microelectrode array, where the electrodes are held at the same potential, affords significant signal enhancement in microchip electrophoresis with amperometric detection. The ability to fabricate an array of carbon ink microelectrodes with a palladium decoupler was demonstrated and the resulting electrodes were integrated with a valving microchip design. The use of an 8 electrode array led to a significant improvement in the limits of detection at the expense of separation resolution due to the increased detection zone size. It is also shown that microdialysis sampling can be integrated with the microchip device and a multi-analyte separation achieved.  相似文献   

2.
This paper presents a capillary electrophoresis poly(methyl methacrylate) (PMMA) based microchip for electrochemical detection applications featuring embedded gold nanoelectrode ensemble (GNEE) working and decoupler electrodes. In fabricating the microchip, the GNEE films are pressed directly onto the metallic electrode structures using a hot embossing technique, and the microfluidic channels are then sealed using a low-temperature azeotropic solvent bonding method. The detection performance of the microchip is evaluated using dopamine and catechol analytes for illustration purposes. The experimental results show that the GNEE working electrode provides a significantly higher signal response than that obtained from a bulk gold electrode when applied to the detection of dopamine analyte. Compared to a conventional bulk palladium decoupler electrode, the GNEE decoupler electrode reduces both the amplitude of the charge current (3.5 nA vs. 18.7 nA) and the baseline drift at higher separation voltages. The measured baseline current drift for the microchip equipped the proposed GNEE decoupler electrode is around three times smaller than the microchip with the palladium decoupler electrode under the applied separation electric field from 40 V/cm to 240 V/cm. Finally, when detecting a mixture of 1mM dopamine and 1mM catechol, the calculated signal response of the microchip with a GNEE decoupler electrode is approximately five times higher than that obtained from a microchip with a bulk Pd decoupler electrode, resulting in the detection limit of 1 microM for the proposed GNEE-based microchip device. Overall, the results indicate that the proposed capillary electrophoresis-electrochemical detection (CE-ED) microchip with embedded GNEE working and decoupler electrodes provides an ideal solution for sample detection in lab-on-a-chip and micro total analysis applications.  相似文献   

3.
自行设计开发了一套便于与电泳芯片集成的一体式柱端安培检测池系统.该系统由整块透明有机玻璃精密加工而成,包括电泳芯片支架和安培检测池两部分,芯片可通过芯片插槽和不锈钢夹具固定在芯片支架上,各种检测用电极可直接通过螺母固定在安培检测池中.以100μmol/L的DA为模式分析物,分别采用直径为100、300和500μm的铂金圆盘电极与表观直径为240μm的碳纤维电极作为工作电极均在该装置上实现了良好组装和高灵敏检测.采用碳纤维工作电极对该系统的检测参数进行了优化.测试结果表明该系统在电化学清洗程序下连续六次测定100μmol/L多巴胺的峰电流相对标准偏差为3.2%,保留时间相对标准偏差为0.5%,DA的检测限为0.4μmol/L(按照S/N=3计).该系统体积小巧,测试稳定,检测灵敏度较高,工作电极更换方便,适合作为芯片电泳柱端安培检测通用平台.  相似文献   

4.
《Electroanalysis》2006,18(2):207-210
A new rigid graphite‐epoxy composite electrode for electrochemical detection in microchip electrophoresis is described. The end‐column wall‐jet detection design relying on tubular rigid composite working electrode shows favorably low noise level and high signal‐to‐noise ratio when compared to glassy carbon detector. The performance of rigid graphite‐epoxy composite detector was compared to glassy carbon detector using dopamine and catechol as model analytes. The various parameters of the microchip electrophoresis‐rigid graphite‐epoxy composite detector were optimized.  相似文献   

5.
Mecker LC  Martin RS 《Electrophoresis》2006,27(24):5032-5042
The fabrication and evaluation of micromolded dual carbon ink electrodes and their integration with a fabricated palladium decoupler for use in microchip electrophoresis is described. As opposed to previous work involving carbon-based dual electrodes with microchip electrophoresis, this approach results in electrodes that are amenable to mass production in a manner where the decoupler/electrode alignment is fixed and reproducible. In this work, electrode sizes and spacings were optimized to result in dual carbon electrodes that are 1 microm in height and separated by 100 microm. Fluorescence microscopy was used to investigate leakage around the electrode/channel interface as well as to investigate what effect the dual electrodes have on band broadening phenomena. The performance of the microelectrodes was demonstrated by the separation and selective dual electrode detection of neurotransmitters in the presence of ascorbic acid. It was also found that addition of SDS to the buffer system improved both the LODs and collection efficiencies. This approach, which is the first involving carbon-based dual electrodes with an on-chip palladium decoupler, will be useful for separating and detecting neurotransmitters that are either collected by in vivo sampling or released from cells on-chip.  相似文献   

6.
The performance of microchip electrophoresis/electrochemistry system with carbon nanotube (CNT) film electrodes was studied. Electrocatalytic activities of different carbon materials (single-wall CNT (SWCNT), multiwall CNT (MWCNT), carbon powder) cast on different electrode substrates (glassy carbon (GC), gold, and platinum) were compared in a microfluidic setup and their performance as microchip electrochemical detectors was assessed. An MWCNT film on a GC electrode shows electrocatalytic effect toward oxidation of dopamine (E(1/2) shift of 0.09 V) and catechol (E(1/2) shift of 0.19 V) when compared to a bare GC electrode, while other CNT/carbon powder films on the GC electrode display negligible effects. Modification of a gold electrode by graphite powder results in a strong electrocatalytic effect toward oxidation of dopamine and catechol (E(1/2) shift of 0.14 and 0.11 V, respectively). A significant shift of the half-wave potentials to lower values also provide the MWCNT film (E(1/2) shift of 0.08 and 0.08 V for dopamine and catechol, respectively) and the SWCNT film (E(1/2) shift of 0.10 V for catechol) when compared to a bare gold electrode. A microfluidic device with a CNT film-modified detection electrode displays greatly improved separation resolution (R(s)) by a factor of two compared to a bare electrode, reflecting the electrocatalytic activity of CNT.  相似文献   

7.
A new method of fabricating electrodes for microchip devices that involves the use of Teflon molds and a commercially available epoxy to embed electrodes of various sizes and compositions is described. The resulting epoxy base can be polished to generate a fresh electrode and sealed against poly(dimethylsiloxane) (PDMS)-based fluidic structures. Microchip-based flow injection analysis was used to characterize the epoxy-embedded electrodes. It was shown that gold electrodes can be amalgamated with liquid mercury and the resulting mercury/gold electrode is used to selectively detect glutathione from lysed red blood cells. The ability to encapsulate multiple electrode materials of differing compositions enabled the integration of microchip electrophoresis with electrochemical detection. Finally, a unique feature of this approach is that the electrode connection is made from the bottom of the epoxy base. This enables the creation of three-dimensional gold pillar electrodes (65?μm in diameter and 27?μm in height) that can be integrated within a fluidic network. As compared with the use of a flat electrode of a similar diameter, the use of the pillar electrode led to improvements in both the sensitivity (72.1 pA/μM for the pillar versus 4.2 pA/μM for the flat electrode) and limit of detection (20 nM for the pillar versus 600 nM for the flat electrode), with catechol being the test analyte. These epoxy-embedded electrodes hold promise for the creation of inexpensive microfluidic devices that can be used to electrochemically detect biologically important analytes in a manner where the electrodes can be polished and a fresh electrode surface is generated as desired.  相似文献   

8.
The first reported use of a carbon paste electrochemical detector for microchip capillary electrophoresis (CE) is described. Poly(dimethylsiloxane) (PDMS)-based microchip CE devices were constructed by reversibly sealing a PDMS layer containing separation and injection channels to a separate PDMS layer that contained carbon paste working electrodes. End-channel amperometric detection with a single electrode was used to detect amino acids derivatized with naphthalene dicarboxaldehyde. Two electrodes were placed in series for dual electrode detection. This approach was demonstrated for the detection of copper(II) peptide complexes. A major advantage of carbon paste is that catalysts can be easily incorporated into the electrode. Carbon paste that was chemically modified with cobalt phthalocyanine was used for the detection of thiols following a CE separation. These devices illustrate the potential for an easily constructed microchip CE system with a carbon-based detector that exhibits adjustable selectivity.  相似文献   

9.
A method to integrate a carbon microelectrode with a microfabricated palladium decoupler for use in microchip capillary electrophoresis (CE) is detailed. As opposed to previous studies with decouplers for microchip CE, the working electrode material, which is made by micromolding of a carbon ink, is different from the decoupling electrode material (palladium). The manner in which the working electrode is made does not add additional etching or lithographic steps to the fabrication of the glass electrode plate. The hybrid poly(dimethylsiloxane)/glass device was characterized with fluorescence microscopy and by monitoring the CE-based separation of dopamine. Hydrodynamic voltammograms exhibited diffusion-limited currents occurring at potentials above +1.0 V. It was also shown that the half-wave potential does not shift as the separation potential is changed, as is the case in nondecoupled systems. Gated injections of dopamine in a 25 mM boric acid buffer (pH 9.2) showed a linear response from 200 to 5 microM (r2 = 0.9992), with a sensitivity of 5.47 pA/microM and an estimated limit of detection of 2.3 microM (0.621 fmol, S/N = 3). This is the first report of coupling a carbon electrode with a decoupler in microchip CE.  相似文献   

10.
Amperometric detector designs for capillary electrophoresis microchips   总被引:1,自引:0,他引:1  
Electrochemical (EC) detection is a sensitive and miniaturisable detection mode for capillary electrophoresis (CE) microchips. Detection cell design is very important in order to ensure electrical isolation from the high separation voltage. Amperometric detectors with different designs have been developed for coupling EC detection to CE-microchips. Different working electrode alignment: in-channel or end-channel has been tested in conjunction with several materials: gold, platinum or carbon. The end-channel detector was based on a platinum or gold wire manually aligned at the exit of the separation channel. Thick- (screen-printed carbon electrode) and thin-film (sputtered gold film) electrodes have also been employed with this configuration, but with a different design that allowed the rapid replacement of the electrode. The in-channel detector was based on a gold film within the separation channel. A gold-based dual electrode detector, which combined for the first time in- and end-channel detection, has been also tested. These amperometric detectors have been evaluated in combination to poly(methylmethacrylate) (PMMA) and Topas (thermoplastic olefin polymer of amorphous structure) CE-microchips. Topas is a new and promising cyclic olefin copolymer with high chemical resistance. Relevant parameters of the polymer microchip separation such as precision, efficiency or resolution and amperometric detection were studied with the different detector designs using p-aminophenol and L-ascorbic acid as model analytes in Tris-based buffer pH 9.0.  相似文献   

11.
Chen C  Teng W  Hahn JH 《Electrophoresis》2011,32(8):838-843
A nanoband electrode detector integrated with a dual-channel polydimethylsiloxane microchip is proposed for in-channel amperometric detection in microchip capillary electrophoresis. Gold nanoband electrodes, which were fabricated on SU-8 substrates with a 100-nm-width gold layer, were introduced into the dual-channel microchip to be an electrochemical detector. Due to the nano-sized width of the detector, the noise of the amperometric detection was significantly reduced, and a high separation resolution was achieved for monitoring the analytes. The detection sensitivity of the system was improved by high signal-to-noise ratio, and a low detection limit on microchip was obtained for p-aminophenol (2.09 nM). Because of the high resolution in measuring half-peak width, the plate number that is used to evaluate the separation efficiency was 1.5-fold higher than that using 50-μm-width electrochemical detector. The effect of sample injection time and data acquisition time on separation efficiency was investigated, and an attractive separation efficiency was achieved with a plate number up to 17,500.  相似文献   

12.
Du Y  Yan J  Zhou W  Yang X  Wang E 《Electrophoresis》2004,25(21-22):3853-3859
We developed an electrochemical detector on a hybrid chip for the determination of glucose in human plasma. The microchip system described in this paper consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate. The copper microelectrode is fabricated by selective electroless deposition. The fabrication of the decoupler is performed by platinum electrochemical deposition on the metal film formed by electroless deposition. Factors influencing the performance, including detection potential, separation field strength, and buffer concentration, were studied. The electrodes exhibited good stability and durability in the analytical procedures. Under optimized detection conditions, glucose responded linearly from 10 microM to 1 mM. Finally, glucose in human plasma from three healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.  相似文献   

13.
《Analytical letters》2012,45(5):435-439
Abstract

During a voltammetric study of the suitability of platinum, gold, glassy carbon, tungsten, and tantalum as electrode materials for generating halogens in constant-current coulometry it was found that glassy carbon, tungsten, and tantalum are not suitable. Both platinum and gold electrodes can be used; with platinum the possibility of interference caused by formation of complexes of the electrode metal with halides is smaller than with gold.  相似文献   

14.
Fang C  Wu B  Zhou X 《Electrophoresis》2004,25(2):375-380
A novel electrophoresis technique, in which the separation column was replaced by a strip of Nafion membrane (5.0 cm x 0.20 mm x 0.25 mm), was developed for the separation of an amino acid mixture (glycine, asparic acid and lysine), followed by quadruple-pulse electrochemical detection. Nafion membrane contains hydrophilic pores (10-20 A and 50-60 A in size) acting as very narrow electrophoresis channels. The fixed-charge sites (-SO(3) (-)) on the hydrophilic pore surface provide a strong charged background. A platinum disk electrode (0.90 mm inner diameter) was employed as the detection electrode and the electrophoresis cathode was used as the quasi-reference and counter electrode for the end-column electrochemical detector, without decoupler. Under optimized conditions the mixture of amino acids could be separated at a voltage of only 90 V with a detection limit of 10(-7) M, indicating that Nafion membrane electrophoresis is a potentially attractive technique for the separation of small organic molecules or ions.  相似文献   

15.
Measurements by capillary flow injection analysis (CFIA) and capillary electrophoresis (CE) in conjunction with electrochemical detection are described. The detection is based on an end-column electrode arrangement. Several novel electrodes, such as a spherical gold electrode and a dual-microdisk electrode, are presented and characterized regarding their analytical utility. In order to improve the selectivity of CFIA, dual-electrode and multiple-pulse detection are studied using couples of cyanometallates or metallocenes. Capillary electrophoretic experiments with amperometric detection are performed using 50 m i.d. capillaries without any electrical-field decoupler. The practicality and analytical characteristics of this detection strategy are illustrated for the separation of serotonin and some biological precursors and metabolites of neurotransmitter substances.  相似文献   

16.
Wang Y  Chen H  He Q  Soper SA 《Electrophoresis》2008,29(9):1881-1888
A fully integrated polycarbonate (PC) microchip for CE with end-channel electrochemical detection operated in an amperometric mode (CE-ED) has been developed. The on-chip integrated three-electrode system consisted of a gold working electrode, an Ag/AgCl reference electrode and a platinum counter electrode, which was fabricated by photo-directed electroless plating combined with electroplating. The working electrode was positioned against the separation channel exit to reduce post-channel band broadening. The electrophoresis high-voltage (HV) interference with the amperometric detection was assessed with respect to detection noise and potential shifts at various working-to-reference electrode spacing. It was observed that the electrophoresis HV interference caused by positioning the working electrode against the channel exit could be diminished by using an on-chip integrated reference electrode that was positioned in close proximity (100 microm) to the working electrode. The CE-ED microchip was demonstrated for the separation of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 132 and 164 nM were achieved for DA and CA, respectively, and a theoretical plate number of 2.5x10(4)/m was obtained for DA. Relative standard deviations in peak heights observed for five runs of a standard solution containing the two analytes (0.1 mM for each) were 1.2 and 3.1% for DA and CA, respectively. The chip could be continuously used for more than 8 h without significant deterioration in analytical performance.  相似文献   

17.
《Comptes Rendus Chimie》2019,22(8):557-561
The electrochemical oxidation of benzaldehyde and four hydroxybenzaldehydes was studied on platinum and glassy carbon electrodes in acetonitrile. A considerable difference was observed in electrooxidation performed on platinum and glassy carbon electrodes. All hydroxy derivatives fouled the glassy carbon electrode, but platinum was passivated only by the electrooxidation of 3-hydroxybenzaldehyde, highlighting the crucial role of the position of the substituent relative to the hydroxy group. On the glassy carbon electrode, the formation of the corresponding benzoyl radical could have taken place, which promoted the buildup of polymers on the electrode surface.  相似文献   

18.
Tay ET  Law WS  Sim SP  Feng H  Zhao JH  Li SF 《Electrophoresis》2007,28(24):4620-4628
A newly developed conductivity detector, the floating resistivity detector (FRD), for microchip electrophoresis was introduced in this work. The detector design permits decoupling of the detection circuit from the high separation voltage without compromising separation efficiency. This greatly simplifies the integration of microchip electrophoresis systems. Its method of detection relies on platinum electrodes being dipped in two buffer-filled branched detection probe reservoirs on the microchip device. In this way, analytes passing through the detection window will not pass through and subsequently adsorb onto the electrodes, alleviating problems of electrode fouling due to analyte contamination and surface reactions. A customized microchip design was proposed and optimized stepwise for the new FRD system. Each branched detection probe was determined to be 4.50 mm long with a 0.075 mm detection window gap between them. The distance between the detection window and buffer waste reservoir was determined to be 1.50 mm. The optimized microchip design was subsequently used in the analysis of four groups of analytes - inorganic cations, amino acids, aminoglycosides antibiotics, and biomarkers. Based on the preliminary results obtained, the detection limits were in the range of 0.4-0.7 mg/L for the inorganic cations and 1.5-15 mg/L for the amino compounds.  相似文献   

19.
Introduced in this article is fabrication of an integrated capillary for the applications of electrochemical detection in capillary electrophoresis. The separation section, voltage decoupler, and working electrode were composed into a single section of capillary. The porous decoupler was constructed by HF etching till the thickness of the capillary wall less than 20 μm. The working electrode was prepared by sputtering Au-films on the outlet of the capillary. The integration of the separation capillary with a complete detection assembly improves the convenience for the routine application of electrochemical measurements in capillary electrophoresis. For a 100-μm-i.d. capillary, the theoretical plate number of catechol and the migration time reproducibility can reach 120,000 and 1.9% RSD, respectively. The linear range exceeds 3 order of magnitude and the detection limit is lower than 0.65 μM.  相似文献   

20.
The present study describes a simple strategy to integrate electrochemical detection with an assembled microchip‐capillary electrophoresis platform. The electrochemical cell was integrated with a microfluidic device consisting of five plastic squares interconnected with fused silica capillaries, forming a four‐way injection cross between the separation channel and three side‐arms (each of 15 mm in length) acting as buffer/sample reservoirs. The performance of the system was evaluated using electrodes made with either carbon ink, carbon nanotubes, or gold and under different experimental conditions of pH, capillary length, and injection time. Using this system it was possible to separate the neurotransmitters dopamine and cathecol and to quantify phenol from a real sample using a linear calibration curve with a calculated LOD of 0.7 µM. A similar concept was applied to determine glucose, by including a pre‐reactor filled with beads modified with glucose oxidase (GOx). The latter system was used to determine glucose in a commercial sample, with a recovery of 95.2 %. Overall, the presented approach represents a simple, inexpensive, and versatile approach to integrate electrochemical detection with CE separations without requiring access to microfabrication facilities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号