首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 793 毫秒
1.
A novel immunosensor has been developed by self‐assembling Au NPs onto a ferrocene‐branched chitosan/multiwalled carbon nanotubes (CS‐Fc/MWCNTs) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg). The formation of CS‐Fc effectively avoids the leakage of Fc and retains its electrochemical activity. Incorporation of MWCNTs and Au NPs into CS‐Fc further increases the electrochemical active Fc in the CS films and provides interactive sites for the immobilization of HBsAb. The morphologies and electrochemistry of the formed biofilm were investigated by using scanning electron microscopy and electrochemical techniques. The immunosensor exhibits a specific response to HBsAg in the range of 1.0–420 ng mL?1. Excellent analytical performance, fabrication reproducibility and operational stability of the proposed immunosensor indicated its promising application in clinical diagnostics.  相似文献   

2.
《Electroanalysis》2005,17(2):155-161
A highly sensitive immunosensor based on immobilization of hepatitis B surface antibody (HBsAb) on platinum electrode (Pt) modified silver colloids and polyvinyl butyral (PVB) as matrixes has been developed for potentiometric immunoanalysis to detect hepatitis B surface antigen (HBsAg) in this study. HBsAb molecules were immobilized successfully on nanometer‐sized silver colloid particles associated with polyvinyl butyral on a platinum electrode surface. The modification procedure was electrochemically monitored by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The HBsAb‐silver‐PVB‐modified electrode exhibited direct electrochemical behavior toward HBsAg. The factors influencing the performance of the resulting immunosensor were studied in detail. More than 94.7% of the results of human serum samples obtained by this method were in agreement with those obtained by enzyme‐linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited a sigmoid curve with log HBsAg concentration, high sensitivity (39.8 mV/decade), wide linear range from 16.0 to 800 ng mL?1 with a detection limit of 3.6 ng mL?1, fast potentiometric response (<3 min) and long‐term stability (>4 months). The response mechanism of the immunosensors was also studied with AC impedance techniques.  相似文献   

3.
An amperometric immunosensor has been developed for sensitive determination of hepatitis B surface antigen as a model protein. A glassy carbon electrode was modified with an assembly of positively charged poly(allylamine)-branched ferrocene (PAA-Fc) and negatively charged gold nanoparticles (Au NPs). The formation of PAA-Fc effectively avoids the leakage of Fc, retains its electrochemical activity, and enhances the conductivity of the composite. The adsorption of Au NPs onto the PAA-Fc matrix provides sites for the immobilization of the antigen and a favorable micro-environment to maintain its activity. The morphologies and electrochemistry of the sensing film were investigated via scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. Factors influencing the performance of the immunosensor were studied in detail. The concentration of the antigen can be quantitated (by measuring the decrease of the amperometric response resulting from the specific binding between antigen and antibody) in the range between 0.1 and 150?ng?mL?C1, with a detection limit of 40?pg?mL?C1 (S/N = 3). The method is economical, efficient, and potentially attractive for clinical immunoassays.
Figure
A novel and sensitive amperometric immunosensor based on the assembly of biocompatible positively charged poly(allylamine)-branched ferrocene and negatively charged Au nanoparticles onto a glassy carbon electrode has been developed for sensitive determination of hepatitis B surface antigen as a model protein.  相似文献   

4.
Immunosenors are of great interest because oftheir potential utility as specific, simple, label-free anddirect detection techniques and reductions in size, costand time of analysis compared with conventional im-munoassay techniques. The immunoassays with …  相似文献   

5.
本文研制了一种用金胶壳聚糖仿生膜来同时固定四甲基联苯胺(TMB)和酶标抗体的新型电化学免疫传感器,用于检测血清肿瘤标志物前列腺特异性抗原(PSA)的含量。固定的TMB作为电子传递媒介体,在扫速小于45 mV/s时,电极表现为一个表面控制过程,而在扫速大于45 mV/s时则表现为一个扩散控制过程。将固定有酶标抗体和TMB的免疫传感器与待测PSA抗原一起培育,在该传感器上形成的免疫复合物通过TMB-H2O2-HRP电化学体系进行了测定。在优化实验条件下,PSA的线性检测范围为5-30 ng·mL-1,检测限为1.0 ng·mL-1。该PSA免疫传感器制备方法简单,成本低廉,具有较好的稳定性和重现性。  相似文献   

6.
A simple, highly sensitive and label‐free electrochemical impedance spectroscopy (EIS) immunosensor was developed using Nafion and gold nanoparticles (nano‐Au/Nafion) composites for the determination of 1‐pyrenebutyric acid (PBA). Under the optimal conditions, the amount of immobilized antibody was significantly improved on the nano‐Au/Nafion electrode due to the synergistic effect and biocompatibility of Nafion film and gold nanoparticles composites. The results showed that the sensitivity and stability of nano‐Au/Nafion composite electrode for PBA detection were much better than those of nano‐Au modified glassy carbon electrode (nano‐Au/GCE). The plot of increased electron transfer resistances (Rets) against the logarithm of PBA concentration is linear over the range from 0.1 to 150 ng·mL?1 with the detection limit of 0.03 ng·mL?1. The selectivity and accuracy of the proposed EIS immunosensor were evaluated with satisfactory results.  相似文献   

7.
以负载Au的金属有机骨架材料(AuNPs/Cu-TPA)标记CEA抗体(Ab2)为信号探针,通过电还原的方法将氧化石墨烯还原到电极上,研制了一种捕获CEA抗体(Ab1)的电化学免疫传感器,并将其应用于癌胚抗原(CEA)检测.所合成的MOFs材料中含有大量Cu2+,且电化学信号比较稳定,因此可以通过检测MOFs材料中Cu2+的信号实现对CEA的检测.此信号探针不需要预处理和酸处理,易负载贵金属从而固定抗体,大大简化了检测步骤并缩短了检测时间.此传感器对CEA的检测灵敏度好,操作简便.在最优实验条件下,此传感器的线性范围为0.1~ 80 ng/mL,检出限为0.03 ng/mL,线性相关系数为0.9887,可用于真实样品中CEA的测定.  相似文献   

8.
In this study, electrochemical immunosensors were developed for the detection of prostate specific antigen (PSA) using ferrocene (Fc) and polyamidoamine dendrimer (PAMAM) constructs. The biosensor fabrication was designed by modifying the screen‐printed gold electrode (Au) with ferrocene cored dendrimers (FcPAMAM) synthesized in three different generations. The self‐assembled monolayer principle was followed, to obtain sensitive, selective and disposable electrodes. Therefore, the Au electrodes were modified with cysteamine (Cys) to obtain a functional surface for FcPAMAM dendrimers to bind. Dendrimer generations were attached to this surface using a cross‐linker (glutaraldehyde) so that a suitable surface was obtained for binding of biological components. The Monoclonal PSA antibody (anti‐PSA) was immobilized on the Au electrode surface which coated with dendrimer, and (Au/Cys/FcPAMAM/anti‐PSA) biosensing electrode was obtained. The PSA detection performances of electrochemical impedance spectroscopy (EIS) and Amperometry based immunosensors exhibited very low detection limits; 0.001 ng mL?1 and 0.1 pg mL?1, respectively. In addition, EIS and Amperometry based biosensors using Au/Cys/FcPAMAM/anti‐PSA sensing electrode were represented excellent linear ranges of 0.01 ng mL?1 to 100 ng mL?1 and 0.001 ng mL?1 to 100 ng mL?1. In order to determine the applicability recovery and selectivity tests were performed using three different proteins in human serum.  相似文献   

9.
We report on the modification of a graphene paste electrode with gold nanoparticles (AuNPs) and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen (HBsAg). To obtain the immunosensor, an antibody against HBsAg was immobilized on the surface of the electrode, and this process was followed by cyclic voltammetry and electrochemical impedance spectroscopy. The peak currents of a hexacyanoferrate redox system decreased on formation of the antibody-antigen complex on the surface of the electrode. Then increased electrochemical response is thought to result from a combination of beneficial effects including the biocompatibility and large surface area of the AuNPs, the high conductivity of the graphene paste electrode, the synergistic effects of composite film, and the increased quantity of HBsAb adsorbed on the electrode surface. The differential pulse voltammetric responses of the hexacyanoferrate redox pair are proportional to the concentration of HBsAg in the range from 0.5–800?ng?mL?1, and the detection limit is 0.1?ng?mL?1 (at an S/N of 3). The immunosensor is sensitive and stable.
Figure
We report on the modification of a graphene paste electrode with gold nanoparticles and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen. The immunosensor is sensitive and stable.  相似文献   

10.
In this article, a detailed electrochemical study of a novel 6‐ferrocenylhexanethiol (HS(CH2)6Fc) self‐assembled multiwalled carbon nanotubes‐Au nanoparticles (MWNTs/Au NPs) composite film was demonstrated. MWNTs/Au NPs were prepared by one‐step in situ synthesis using linear polyethyleneimine (PEI) as bifunctionalizing agent. HS(CH2)6Fc, which acted as the redox mediator, was self‐assembled to MWNTs/Au NPs via Au‐S bond. Transmission electron microscopy (TEM), energy‐dispersive X‐ray analysis (EDX), Fourier transformed infrared absorption spectroscopy (FT‐IR), UV‐visible absorption spectroscopy, and cyclic voltammetry were used to characterize the properties of the MWNTs/Au NPs/HS(CH2)6Fc nanocomposite. The preparation of the nanocomposite was very simple and effectively prevented the leakage of the HS(CH2)6Fc mediator during measurements. The electrooxidation of AA could be catalyzed by Fc/Fc+ couple as a mediator and had a higher electrochemical response due to the unique performance of MWNTs/Au NPs. The nanocomposite modified electrode exhibited excellent catalytic efficiency, high sensitivity, good stability, fast response (within 3 s) and low detection limit toward the oxidation of AA at a lower potential.  相似文献   

11.
In this work, a novel sandwich‐type electrochemical immunosensor with electroactive nickel hexacyanoferrate nanoparticles (NiHCFNPs) as matrix was constructed for α‐fetoprotein (AFP) detection in a signal‐off manner by using FeS2?AuNPs nanocomposite catalyzed insoluble precipitation to significantly inhibit the electrochemical signal. Initially, the NiHCFNPs with excellent electrochemical property was modified on the electrodeposited nano‐Au electrode to obtain a strong initial electrochemical signal. Subsequently, another nano‐Au layer was formed for immobilization of capture antibody (Ab1). In the presence of target AFP, the prepared FeS2?AuNPs‐Ab2 bioconjugate could be specifically recognized and immobilized on electrode through the sandwich‐type immunoreaction. The FeS2 with large specific surface areas were used as scaffolds to load abundant mimicking enzyme AuNPs. With the help of hydrogen peroxide (H2O2), FeS2?AuNPs with peroxidase‐like activity accelerated the 4‐chloro‐1‐naphthol (4‐CN) oxidation with generation of insoluble precipitation on electrode, which would greatly hinder the electron transfer and thus caused the decrease of electrochemical signal for quantitative determination of AFP. This approach achieved a wide dynamic linear range from 0.0001 to 100 ng mL?1 with an ultralow limit detection of 0.028 pg mL?1. Especially, the proposed AFP immunosensor can be applied to detect human serum samples with satisfactory results, indicating a potential application in clinical monitoring of tumor biomarkers.  相似文献   

12.
A sensitive and specific electrochemical immunosensor was developed with α‐fetoprotein (AFP) as the model analyte by using gold nanoparticle label for enzymatic catalytic amplification. A self‐assembled monolayer membrane of mercaptopropionic acid (MPA) was firstly formed on the electrode surface through gold‐sulfur interaction. Monoclonal mouse anti‐human AFP was covalently immobilized to serve as the capture antibody. In the presence of the target human AFP, gold nanoparticles coated with polyclonal rabbit anti‐human AFP were bound to the electrode via the formation of a sandwiched complex. With the introduction of goat anti‐rabbit IgG conjugated with alkaline phosphatase, the dentritical enzyme complex was formed through selective interaction of the secondary antibodies with the colloidal gold‐based primary antibody at the electrode, thus affording the possibility of signal amplification for AFP detection. Current response arising from the oxidation of enzymatic product was significantly amplified by the dentritical enzyme complex. The current signal was proportional to the concentration of AFP from 1.0 ng mL?1 to 500 ng mL?1 with a detection limit of 0.8 ng mL?1. This system could be extended to detect other target molecules with the corresponding antibody pairs.  相似文献   

13.
《Electroanalysis》2018,30(2):353-360
A label‐free electrochemical immunosensor based on the liquid crystal (E)‐1‐decyl‐4‐[(4‐decyloxyphenyl)diazenyl]pyridinium bromide (Br−Py), together with heparin‐stabilized gold nanoparticles (AuNP‐Hep) and Nafion is proposed for the determination of prostate‐specific antigen (PSA). The Br−Py liquid crystal presented redox properties and good film‐forming abilities on the electrode surface, and thus it is a suitable alternative as a redox probe for a label‐free electrochemical immunosensor, which could simplify the analysis methodology. The stepwise construction of the immunosensor and the incubation process (immunocomplex formation) were characterized by voltammetry and electrochemical impedance spectroscopy. The proposed immunosensor could directly detect PSA concentrations in the incubation samples, based on the suppression of the Br−Py redox peak (‘base peak’) current. After optimization, the immunosensor exhibited a linear response to PSA concentrations in the range of 0.1 to 50 ng mL−1, with a calculated detection limit of 0.08 ng mL−1. The reproducibility (coefficient of variance less than 3.0 %), selectivity and accuracy of the methodology were adequate. The immunosensor was satisfactorily applied in the quantification of PSA in human blood plasma samples.  相似文献   

14.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

15.
Lu Zhou  Ruo Yuan  Yaqin Chai 《Electroanalysis》2007,19(11):1131-1138
A poly(vinylchloride) (PVC) membrane based potentiometric immunosensor for the direct detection of alpha‐fetoprotein (AFP) has been developed. First, Au colloid particle was chemisorbed upon amino groups of o‐phenylenediamine, which were dissolved in plasticized PVC membrane. Then alpha‐fetoprotein antibody (anti‐AFP) was immobilized upon the surface of the Au colloid particle to prepare a potentiometric AFP immunosensor. The Au colloid particle modified PVC membrane was characterized by digital photo and transmission electron microscope (TEM). The immunosensor exhibited fast potentiometric response (≤4 min) and showed specific response to AFP in the range of 4.9 to 158.5 ng/mL with a correlation coefficient of 0.9971 and a detection limit of 1.6 ng/mL. The factors influencing the performance of the immunosensor were also studied in detail. Moreover, the proposed method is economical and efficient as well as potentially attractive for clinical immunoassays.  相似文献   

16.
This paper describes a highly sensitive and label‐free electrochemical immunosensor for the detection of 1‐pyrenebutyric acid (PBA) which is based on a graphene (GS), chitosan (CS), and ionic liquid (IL) composite modified glassy carbon electrode (GS‐CS‐IL/GCE). The modification process was monitored by transmission electron microscopy (TEM) and cyclic voltammetry (CV). Due to the synergistic effects of GS, CS, and IL, the biosensor exhibits excellent selectivity to PBA. The current response of the proposed immunosensor decreases linearly at two concentration ranges from 0.01 to 5 and from 5 to 150 ng mL?1 with a detection limit of 0.01 ng mL?1.  相似文献   

17.
In the present work, a newly functional nanoparticle has been prepared to immobilize the protein for the detection of α‐1‐fetoprotein (AFP). Prussian blue (PB) nanoparticle was initially synthesized under ultrasonic condition, then bovine serum albumin (BSA) was used to coat the PB nanoparticle to improve the stability of the PB nanoparticle as well as functionalize the surface of PB nanoparticle, and then gold colloids were loaded on the BSA‐coated PB nanoparticle to construct a core‐shell‐shell nanostructure via the conjunction of thiolate linkages or alkylamines of the BSA. Finally, a convenient, effective and sensitivity amperometric immunosensor for the detection of α‐1‐fetoprotein (AFP) was constructed by the employment of these functional core‐shell‐shell microspheres. The preparation of the nanoparticle (Au‐BSA‐PB NPs) was characterized by transmission electron microscopy (TEM), and the assembly of the biosensor was characterized with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The dynamic range of the resulted immunosensor for the detection of AFP is from 0.02 ng/mL to 200.0 ng/mL with a detection limit of 0.006 ng/mL (S/N=3). Moreover, this biosensor displays good selectivity, stability and reproducibility.  相似文献   

18.
Calmodulin (CaM) is an important intracellular calcium‐binding protein. It plays a critical role in a variety of biological and biochemical processes. In this paper, a new electrochemical immunosensing protocol for sensitive detection of CaM was developed by using gold‐silver‐graphene (AuAgGP) hybrid nanomaterials as protein immobilization matrices and gold nanorods (GNRs) as enhanced electrochemical labels. Electrode was first modified with thionine‐chitosan film to provide an immobilization support for gold‐silver‐graphene hybrid nanomaterials. The hybrid materials formed an effective matrix for binding of CaM with high density and improved the electrochemical responses as well. Gold nanorods were prepared for the fabrication of enhanced labels (HRP‐Ab2‐GNRs), which provided a large capacity for HRP‐Ab2 immobilization and a facile pathway for electron transfer. With two‐step immunoassay format, the HRP‐Ab2‐GNRs labels were introduced onto the electrode surface, and produced electrochemical responses by catalytic reaction of HRP toward enzyme substrate of hydrogen peroxide (H2O2) in the presence of thionine. The proposed immunosensor showed an excellent analytical performance for the detection of CaM ranging from 50 pg mL?1 to 200 ng mL?1 with a detection limit of 18 pg mL?1. The immunosensor has also been successfully applied to the CaM analysis in two cancer cells (HepG2 and MCF‐7) with high sensitivity, which has shown great potency for improving clinic diagnosis and treatment for cancer study.  相似文献   

19.
Cytomegalovirus is typically associated with immunocompromised hosts, pregnant women and transplant patients, who require a timely diagnosis. In this work, a sensitive and highly specific electrochemical amplification immunosensor was established for detecting Cytomegalovirus pp65 antigen based on Pt‐PdNPs@SWCNHs with horseradish peroxidase (HRP) as a signal enhancer and thionine as a signal probe. First, Pt nanoparticle (PtNP) and Pd nanoparticle (PdNP) functionalized single‐walled carbon nanohorn (SWCNH) nanocomposites, i.e. Pt‐PdNPs@SWCNHs, was used as a carrier for immobilization of antibody through the Pt‐N bond and the Pd‐N bond. Next, HRP was used to block the rest of the binding‐sites. Signal amplification was obtained by the cooperative catalytic activities of Pt‐PdNPs and HRP to H2O2. SWCNHs loaded with a large amount of Pt‐PdNPs further amplified the signal due to the excellent surface area. The fabricated immunosensor was used to detect different concentrations of Cytomegalovirus pp65 antigen under optimized conditions. The tests showed a linear range from 0.1 to 80 ng mL?1 with a low detection limit of 30 pg mL?1, and exhibited excellent selectivity, stability and reproducibility. Therefore, this project presented a potential approach for the early diagnosis of Cytomegalovirus infection in clinical trials.  相似文献   

20.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号