首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polyacrylamide gel electrophoresis is widely used for protein separation and it is frequently the final step in protein purification in biochemistry and proteomics. Using a commercially available amine-reactive isobaric tagging reagent (iTRAQ) and mass spectrometry we obtained reproducible, quantitative data from peptides derived by tryptic in-gel digestion of proteins and phosphoproteins. The protocol combines optimized reaction conditions, miniaturized peptide handling techniques and tandem mass spectrometry to quantify low- to sub-picomole amounts of (phospho)proteins that were isolated by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Immobilized metal affinity chromatography (FeIII-IMAC) was efficient for removal of excess reagents and for enrichment of derivatized phosphopeptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. Phosphopeptide abundance was determined by liquid chromatography/tandem mass (LC/MS/MS) using either MALDI time-of-flight/time-of-flight (TOF/TOF) MS/MS or electrospray ionization quadrupole time-of-flight (ESI-QTOF) MS/MS instruments. Chemically labeled isobaric phosphopeptides, differing only by the position of the phosphate group, were distinguished and characterized by LC/MS/MS based on their LC elution profile and distinct MS/MS spectra. We expect this quantitative mass spectrometry method to be suitable for systematic, comparative analysis of molecular variants of proteins isolated by gel electrophoresis.  相似文献   

2.
The enrichment of phosphopeptides using immobilized metal ion affinity chromatography (IMAC) and subsequent mass spectrometric analysis is a powerful protocol for detecting phosphopeptides and analyzing their phosphorylation state. However, nonspecific binding peptides, such as acidic, nonphosphorylated peptides, often coelute and make analyses of mass spectra difficult. This study used a partial chemical tagging reaction of a phosphopeptide mixture, enriched by IMAC and contaminated with nonspecific binding peptides, following a modified beta-elimination/Michael addition method, and dynamic mass analysis of the resulting peptide pool. Mercaptoethanol was used as a chemical tag and nitrilotriacetic acid (NTA) immobilized on Sepharose beads was used for IMAC enrichment. The time-dependent dynamic mass analysis of the partially tagged reaction mixture detected intact phosphopeptides and their mercaptoethanol-tagged derivatives simultaneously by their mass difference (-20 Da for each phosphorylation site). The number of new peaks appearing with the mass shift gave the number of multiply phosphorylated sites in a phosphopeptide. Therefore, this partial chemical tagging/dynamic mass analysis method can be a powerful tool for rapid and efficient phosphopeptide identification and analysis of the phosphorylation state concurrently using only MS analysis data.  相似文献   

3.
Several phospho- and sulfopeptides were subjected to atmospheric pressure thermal dissociation (APTD), which was effected by passing peptide ions generated by electrosonic spray ionization (ESSI) through a heated coiled metal tube. Sequence informative fragment ions including a-, b-, c-, and y-types of ions were observed with increased relative intensities under APTD compared with collision-induced dissociation (CID), performed inside the ion trap. A certain degree of preservation of phosphate and sulfate ester moieties was observed for some fragments ions under APTD. The neutral fragments generated outside the mass spectrometer were further analyzed via on-line corona discharge to provide rich and complementary sequence information to that provided by the fragment ions directly obtained from APTD, although complete losses of the modification groups were noted. Improved primary sequence information for phospho- and sulfopeptides was typically obtained by analyzing both ionic and neutral fragments from APTD compared with fragment ions from CID alone. Localization of the modification sites of phospho- and sulfopeptides was achieved by combining the structural information acquired from APTD and CID.  相似文献   

4.
Structural characterization of sulfated glycans through mass spectrometry (MS) has been often limited by their low abundance in biological materials and inefficient ionization in the positive-ion mode. Here, we describe a microscale method for sequentially enriching sulfated glycans according to their degree of sulfation. This method is based on modifying the binding ability of strong anion-exchange material through the use of different sodium acetate concentrations, thus enabling fairly selective binding and a subsequent elution of different glycans according to their degree of sulfation. Before this enrichment, the negative charge on the sialic acid, which is commonly associated with such glycans, was eliminated through permethylation that is used to enhance the positive-ion mode matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS) signal for all glycans. This enrichment approach minimizes competitive ionization between sulfated and neutral glycans, as well as that between sulfated species with a different degree of sulfation. The described method was initially optimized using sulfated oligosaccharide standards, while its potential has been verified for the sulfated N-glycans originated from the bovine thyroid-stimulating hormone (bTSH), a glycoprotein possessing mono- and disulfated N-glycans. This enhancement of the MALDI-MS signal facilitates analysis of some otherwise undetected components.  相似文献   

5.
The use of a high-performance orthogonal time-of-flight (o-TOF) mass spectrometer for sequence analysis is described. The mass spectrometer is equipped with a matrix-assisted laser desorption/ionization (MALDI) source that operates at elevated pressure, 0.01-1 Torr. Ion fragmentation is controlled by varying the pressure of the buffer gas, the laser energy, the voltage difference between the MALDI target and the adjacent sampling cone, and between the cone and the quadrupole ion guide. The peptides were analyzed under optimal ionization conditions to obtain their molecular mass, and under conditions that promote ion dissociation via metastable decomposition or collision-induced dissociation (CID). The fragmentation spectra were used to obtain sequence information. Ion dissociation was promoted via three configurations of the ionization parameters. All methods yielded sequencing-grade b- and y-type ions. Two binary mixtures of peptides were used to demonstrate that: (1) external calibration provides a standard deviation (sigma) of 4 ppm with a mode of 9 ppm; and (2) that peptides with molecular masses that differ by a factor of two may be independently fragmented by appropriately choosing the CID energy and the low-mass cut-off. Analyses of tryptic digests employed liquid chromatography (LC), deposition of the eluant on a target, and finally MALDI-TOF mass spectrometry. The mass fingerprint and the (partial) sequence of the tryptic peptides were matched to their precursor protein via database searches.  相似文献   

6.
Kailasa SK  Wu HF 《The Analyst》2012,137(7):1629-1638
The sensitivity and efficiency of SALDI-MS or MALDI-MS is mainly dependent on the nature of matrix. A novel approach is proposed for one-pot synthesis of dopamine dithiocarbamate-functionalized gold nanoparticles (DDTC-Au NPs). Their application to quantification of small molecules by surface assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) and rapid identification of phosphopeptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is investigated. The synthesized DDTC-Au NPs were characterized by UV-visible and FT-IR spectroscopy, H(1)NMR, SEM and TEM. DDTC-Au NPs offers marked improvement on analyte ionization and effectively suppressed the background noise which leads to clean mass spectra. We also demonstrated the use of DDTC-Au NPs as affinity probes for selective enrichment of phosphopeptides from the solutions of microwave tryptic digested casein proteins. Compared with a conventional matrix, DDTC-Au NPs exhibited a high desorption/ionization efficiency for accurate quantification of small molecules including amino acid (glutathione), drugs (desipramine and enrofloxacin) and peptides (valinomycin and gramicidin D) and successfully utilized as novel affinity probes for straightforward and rapid identification of phosphopeptides from casein proteins (α-, β-casein and nonfat milk), showing a great potentiality to the real-time analysis.  相似文献   

7.
Titanium dioxide metal oxide affinity chromatography (TiO2‐MOAC) is widely regarded as being more selective than immobilized metal‐ion affinity chromatography (IMAC) for phosphopeptide enrichment. However, the widespread application of TiO2‐MOAC to biological samples is hampered by conflicting reports as to which experimental conditions are optimal. We have evaluated the performance of TiO2‐MOAC under a wide range of loading and elution conditions. Loading and stringent washing of peptides with strongly acidic solutions ensured highly selective enrichment for phosphopeptides, with minimal carryover of non‐phosphorylated peptides. Contrary to previous reports, the addition of glycolic acid to the loading solution was found to reduce specificity towards phosphopeptides. Base elution in ammonium hydroxide or ammonium phosphate provided optimal specificity and recovery of phosphorylated peptides. In contrast, elution with phosphoric acid gave incomplete recovery of phosphopeptides, whereas inclusion of 2,5‐dihydroxybenzoic acid in the eluant introduced a bias against the recovery of multiply phosphorylated peptides. TiO2‐MOAC was also found to be intolerant of many reagents commonly used as phosphatase inhibitors during protein purification. However, TiO2‐MOAC showed higher specificity than immobilized gallium (Ga3+), immobilized iron (Fe3+), or zirconium dioxide (ZrO2) affinity chromatography for phosphopeptide enrichment. Matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) was more effective in detecting larger, multiply phosphorylated peptides than liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS), which was more efficient for smaller, singly phosphorylated peptides. Copyright © 2009 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

8.
A new set-up for microwave-assisted acid hydrolysis (MAAH) with high efficiency and reproducibility to degrade proteins into peptides for mass spectrometry analysis is described. It is based on the use of an inexpensive domestic microwave oven and can be used for low volume protein solution digestion. This set-up has been combined with liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry (LC-ESI QTOF MS) for mapping protein sequences and characterizing phosphoproteins. It is demonstrated that for bovine serum albumin (BSA), with a molecular mass of about 67,000 Da, 1292 peptides (669 unique sequences) can be detected from a 2 μg hydrolysate generated by trifluoroacetic acid (TFA) MAAH. These peptides cover the entire protein sequence, allowing the identification of an amino acid substitution in a natural variant of BSA. It is shown that for a simple phosphoprotein containing one phosphoform, β-casein, direct analysis of the hydrolysate generates a comprehensive peptide map that can be used to identify all five known phosphorylation sites. For characterizing a complex phosphoprotein consisting of different phosphoforms with varying numbers of phosphate groups and/or phosphorylation sites, such as bovine αs1-casein, immobilized metal-ion affinity chromatography (IMAC) is used to enrich the phosphopeptides from the hydrolysate, followed by LC-ESI MS analysis. The MS/MS data generated from the initial hydrolysate and the phosphopeptide-enriched fraction, in combination with MS analysis of the intact protein sample, allow us to reveal the presence of three different phosphoforms of bovine αs1-casein and assign the phosphorylation sites to each phosphoform with high confidence.  相似文献   

9.
Titanium dioxide (TiO2)-mediated phosphopeptide enrichment has been introduced as an effective method for extracting phosphopeptides from highly complex peptide mixtures. Chemical labeling by beta-elimination/Michael addition is also useful for increasing mass intensity in phosphopeptide analysis. Both of these methods were coupled in order to simultaneously enrich phosphopeptides and allow for detection and sequencing of the enriched peptides with high mass sensitivity. Phosphopeptides were successfully enriched on TiO2 beads without the use of any hydroxy acid additives like 2,5-dihydroxybenzoic acid. Labeling was accomplished on-bead with a guanidinoethanethiol (GET) tag containing a guanidine moiety. These GET-labeled derivatives were detected by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). GET labeling converted phosphoserine into guanidinoethylcysteine, a structural arginine-mimic. In particular, GET-labeled lysine-terminated phosphopeptides showed dramatically increased peak intensities compared to those of the corresponding intact phosphopeptides. Additionally, the on-bead labeling minimized manipulation steps and sample loss. The coupled technique was also further validated by applying to the analysis of phosphopeptides from complex tryptic digests of phosphoprotein mixtures.  相似文献   

10.
自20世纪80年代发明基质辅助激光解吸电离(Matrix assisted laser desorption ionization,MALDI)质谱以来,该技术已在生物分子分析方面得到了广泛应用.作为一种离子化方法,MALDI具有灵敏度高,对样品要求低,能耐高浓度盐和缓冲剂等优点.测定过程中使用合适的基质不仅能提高测试灵敏度和分辨率,还能扩增测试样品的种类。  相似文献   

11.
Vitellogenin is a protein produced by the liver of oviparous animals in response to circulating estrogens. The amino acid sequence of vitellogenin from Atlantic cod (Gadus morhua) has not yet been determined. In this study Atlantic cod vitellogenin was characterized using a 'bottom-up' mass spectrometric approach. Vitellogenin synthesis was induced 'in vivo' with beta-estradiol, and subjected to trypsin digestion for characterization by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry. A peptide mass fingerprint was obtained and 'de novo' sequencing of the most abundant tryptic peptides was performed by low-energy collision-induced dissociation tandem mass spectrometry. As a result of these experiments, the sequences of various tryptic peptides have been elucidated. The database search has shown that Atlantic cod vitellogenin shares a series of common peptides with the two different known vitellogenin sequences of haddock, a closely related species. These findings allow us to propose that Atlantic cod might also co-express at least two distinct forms of vitellogenin.  相似文献   

12.
Liquid chromatography/electrospray ionization mass spectrometry was used to investigate the peptide composition of the venom of Conus pennaceus, a molluscivorous cone shell from the Red Sea. Based on observed M(r)s, this venom contained all known conotoxins previously isolated and identified from this species. Interestingly, the doubly protonated species of only two of these conotoxins, alpha-PnIA and alpha-PnIB, showed additional related ions at +40 m/z (+80 Da), indicating the presence of either sulfation or phosphorylation in both components. High-performance liquid chromatographic (HPLC) fractions containing these two conotoxins were examined by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry in both positive and negative ion modes, as well as by MALDI high-energy collision-induced dissociation. These experiments established the presence of a single sulfated tyrosine residue within both alpha-PnIA and alpha-PnIB. Hence their post-translationally modified sequences are GCCSLPPCAANNPDY(S)C-NH2 (alpha-PnIA) and GCCSLPPCALSNPDY(S)C-NH2 (alpha-PnIB). This assignment was supported by comparison of their mass spectral behavior with that of known sulfated and phosphorylated peptides. This data clarified further the distinguishing features of the ionization and fragmentation of such modified peptides. Selective disulfide folding of synthetic alpha-PnIB demonstrated that both sulfated and non-sulfated toxins co-elute on reversed-phase HPLC and that alpha-PnIB possesses the same disulfide connectivity as other 'classical' alpha-conotoxins reported previously.  相似文献   

13.
Shiau KJ  Hung SU  Lee HW  Wu CC 《The Analyst》2011,136(9):1922-1927
Simultaneous detection of multiply and singly phosphorylated peptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging because of suppression effects during ionization. In oder to overcome this problem, this study presents a new approach to improve the detection of phosphopeptides by stepwise enrichment using polyarginine-coated (PA-coated) and titanium dioxide-coated (TiO(2)-coated) nanodiamonds for fractionation of multiply and singly phosphorylated peptides prior to on-probe MALDI MS analysis. The feasibility of this approach was demonstrated using synthetic peptides containing different numbers of phosphate groups, tryptic digests of α-casein, β-casein, and complex protein mixtures. The high specificity of the approach is shown in its effective enrichment and fractionation of phosphopeptides from the digest of β-casein and bovine serum albumin at a molar ratio as low as 1 : 1000, which out-performs the commercial Fe(3+)-IMAC and TiO(2) isolation kits. It offers a simple and effective alternative for the fractionation and identification of multiply and singly phosphorylated peptides by MALDI MS and allows for deduction of more information from limited starting materials.  相似文献   

14.
We describe a useful method for the efficient ionization and relative quantification of peptides containing serine/threonine phosphorylation sites. This method is based on beta-elimination of the phosphate group from serine/threonine phosphorylation sites under alkaline conditions, followed by Michael addition reaction with N-(2-mercaptoethyl)-6-methylnicotinamide (MEMN). As a result of the derivatization reaction, the negatively charged phosphate group is substituted with the nicotinoyl moiety to improve the ionization efficiency of the derivatized peptide. The combination of d(3)-labeled MEMN (d(3)-MEMN) and MEMN (d(0)-MEMN) generates a 3 Da mass difference between d(3)-MEMN-labeled and d(0)-MEMN-labeled peptides, which is a useful signature for the identification of peptides containing serine/threonine phosphorylation sites in the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrum. Moreover, the mass difference is useful for the quantitative analysis of serine/threonine phosphorylation in proteins. In this paper, we describe the synthesis of d(0)/d(3)-labeled MEMN and an application of our approach to model peptides and proteins.  相似文献   

15.
《Analytical letters》2012,45(14):2554-2563
The present paper describes a biomarker capturing strategy based on the enrichment efficiency of multiwalled carbon nanotubes (MWCNTs) for peptides and proteins from human serum. The method is shown to enrich proteins/peptides, and the captured molecules were profiled using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Mass spectra of the MWCNTs-treated human serum samples showed a significant enrichment of proteins by MWCNTs. Preliminary results indicated a good level of reproducibility in serum profiles with coefficients of variation (CVs) on signal intensity ranging from 8.9% to 25.2%. The developed method holds promise for improving the discovery of low-abundance serum biomarkers.  相似文献   

16.
A simple and inexpensive nano high performance liquid chromatography system (nano-LC) employing the exponential dilution method for gradient separations was built. The system was used to analyze a tryptic digest of Escherichia coli uracil DNA glycosylase (Ung; Mr = 25,563), a DNA-binding protein that initiates the uracil-excision DNA repair process by catalyzing the release of uracil from the deoxyribose phosphate backbone of DNA. Both on-line and off-line approaches to analyzing peptides produced by in-gel digestion of Ung are demonstrated. The on-line approach uses nano-high performance liquid chromatography (HPLC)/micro-electrospray MS to assign peptide masses. The off-line approach uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and nano-electrospray/collision-induced dissociation (CID) tandem mass spectrometry, to analyze fractions (2-3 microL) collected manually from the nano-LC system. The nano-electrospray technique allows detailed fragmentation information to be obtained at different collision energies with only a marginal increase in sample handling due to the nano-LC step.  相似文献   

17.
This article describes results of low-level (sub-femtomole) detection of peptides by matrix-assisted laser desorption ionization. The matrix-assisted laser desorption ionization method can be used for low-level detection of the parent ion, either [M + H]+ or [M + Na]+, and collision-induced dissociation of the parent ion can be performed at the picomole level. The instrument used for these studies is a novel high-performance magnetic sector (electric(E)/magnetic(B) sector)/reflectron time-of-flight (TOP) tandem mass spectrometer (EB/TOF).  相似文献   

18.
The analysis of acylated proteins by mass spectrometry (MS) has largely been overshadowed in proteomics by the analysis of glycosylated and phosphorylated proteins; however, lipid modifications on proteins are proving to be of increasing importance in biomedical research. In order to identify the marker ions and/or neutral loss fragments that are produced upon collision-induced dissociation, providing a means to identify the common lipid modifications on proteins, peptides containing an N-terminally myristoylated glycine, a palmitoylated cysteine and a farnesylated cysteine were chemically synthesized. Matrix-assisted laser desorption/ionization time-of-flight time-of-flight (MALDI-TOF-TOF), electrospray ionization quadrupole time-of-flight (ESI Q-TOF), and electrospray ionization hybrid triple-quadrupole/linear ion trap (ESI QqQ(LIT)) mass spectrometers were used for the analysis. The peptide containing the N-terminally myristoylated glycine, upon CID, produced the characteristic fragments a1 (240.4 Th) and b1 (268.4 Th) ions as well as a low-intensity neutral loss of 210 Da (C14H26O). The peptides containing a farnesylated cysteine residue fragmented to produce a marker ion at a m/z of 205 Th (C15H25) as well as other intense farnesyl fragment ions, and a neutral loss of 204 Da (C15H24). The peptides containing a palmitoylated cysteine moiety generated neutral losses of 238 Da (C16H30O) and 272 Da (C16H32OS); however, no marker ions were produced. The neutral losses were more prominent in the MALDI-TOF-TOF spectra, whereas the marker ions were more abundant in the ESI QqQ(LIT) and Q-TOF mass spectra.  相似文献   

19.
Presented is a method for analyzing sulfated peptides, and differentiating the post-translational modification (PTM) from its isobaric counterpart phosphorylation, using quadrupole time-of-flight (Qq/TOF) mass spectrometry (MS) and positive ion nanoelectrospray MS/MS. A set of commercially available sulfo- and phosphopeptide standards was analyzed via in-source dissociation and MS/MS to generate fragmentation signatures that were used to characterize and differentiate the two modifications. All of the phosphorylated peptides retained their +80 Da modifications under collision-induced decomposition (CID) conditions and peptide backbone fragmentation allowed for the site-specific identification of the modification. In sharp contrast, sulfated peptides lost SO3 from the precursor as the collision energy (CE) was increased until only the non-sulfated form of the peptide was observed. The number of 80 Da losses indicated the number of sulfated sites. By continuing to ramp the CE further, it was possible to fragment the non-sulfated peptides and obtain detailed sequence information. It was not possible to obtain site-specific information on the location of the sulfate moieties using positive ion MS/MS as none of the original precursor ions were present at the time of peptide backbone fragmentation. This method was applied to the analysis of recombinant human B-domain deleted factor VIII (BDDrFVIII), which has six well-documented sulfation sites and several potential phosphorylation sites located in two of the sulfated regions of the protein. Seven peptides with single and multiple +80 Da modifications were isolated and analyzed for their respective PTMs. The fragmentation patterns obtained from the BDDrFVIII peptides were compared with those obtained for the standard peptides; and in all cases the peptides were sulfated. None of the potential phosphorylation sites were found to be occupied, and these results are consistent with the literature.  相似文献   

20.
Electrospray ionization mass spectrometry (ESI/MS) affords a rapid and sensitive technique for determining peptides produced by the enzymatic digestion of phosphoroteins. When coupled with on-line immobilized metal-ion affinity chromatography (IMAC), the combmation allows separation and mass spectrometric identification of phosphorylated and nonphosphorylated peptides. In this study, the feasibility and general applicability of on-line IMAC/ESI/MS is investigated by using immobilized ferric ions for selective chelation of several phosphotyrosine and phosphoserine peptides. The sensitivity and practicality of the technique for phosphoproteins are demonstrated via the analysis of 30 pmol (~0.7 μg) of bovine β-casein purified by sodium dodecylsulfate-polyacrylamide gel electrophoresis, electroblotted onto a polyvinylidene difluoride membrane, and digested in situ with trypsin. It is observed that on-line IMAC/ESI/MS suffers less from sample losses than experiments performed off-line, suggesting that the limiting factors in sensitivity for this technique are the purification procedures and sample handling rather than the IMAC and mass spectrometry. Thus, the ability to inject the tryptic digest of an electroblotted protein directly onto the column without buffer exchange and to analyze the eluent directly via on-line coupling of the IMAC column to the mass spectrometer greatly reduces sample losses incurred through sample handling and provides a convenient method for analyzing phosphopeptides at low levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号