首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A microfluidic based solid-phase assay for the multiplexed detection of nucleic acid hybridization using quantum dot (QD) mediated fluorescence resonance energy transfer (FRET) is described herein. The glass surface of hybrid glass-polydimethylsiloxane (PDMS) microfluidic channels was chemically modified to assemble the biorecognition interface. Multiplexing was demonstrated using a detection system that was comprised of two colors of immobilized semi-conductor QDs and two different oligonucleotide probe sequences. Green-emitting and red-emitting QDs were paired with Cy3 and Alexa Fluor 647 (A647) labeled oligonucleotides, respectively. The QDs served as energy donors for the transduction of dye labeled oligonucleotide targets. The in-channel assembly of the biorecognition interface and the subsequent introduction of oligonucleotide targets was accomplished within minutes using a combination of electroosmotic flow and electrophoretic force. The concurrent quantification of femtomole quantities of two target sequences was possible by measuring the spatial coverage of FRET sensitized emission along the length of the channel. In previous reports, multiplexed QD-FRET hybridization assays that employed a ratiometric method for quantification had challenges associated with lower analytical sensitivity arising from both donor and acceptor dilution that resulted in reduced energy transfer pathways as compared to single-color hybridization assays. Herein, a spatial method for quantification that is based on in-channel QD-FRET profiles provided higher analytical sensitivity in the multiplexed assay format as compared to single-color hybridization assays. The selectivity of the multiplexed hybridization assays was demonstrated by discrimination between a fully-complementary sequence and a 3 base pair sequence at a contrast ratio of 8 to 1.  相似文献   

2.
We describe a method of performing multiple enzyme assays in a single reaction vessel. The resolving power of capillary electrophoresis enables several enzyme assays to be analyzed at high speed in microfluidic arrays. Multiplexed measurement can increase throughput significantly without requiring highly dense microfluidic arrays. Enzyme assays in a multiplexed format for selected kinases in this work show essentially identical performance to assays performed individually. This establishes an approach for screening one compound against multiple enzyme targets simultaneously. Another potential application for performing multiplexed enzyme assay is to study protein-protein (especially enzyme-enzyme) interaction by monitoring the enzymatic activity changes.  相似文献   

3.
4.
Microfluidic platforms can lead to miniaturisation, increased throughput and reduced reagent consumption, particularly when the processes are automated. Here, a programmable microcontroller is used for automation of a microfluidic platform configured to electrochemically determine the levels of 8 proteins simultaneously in complex liquid samples. The platform system is composed of a programmable Arduino microcontroller that controls inexpensive valve actuators, pump, magnetic stirrer and electronic display. The programmable microcontroller results in repeatable timing for each step in a complex assay protocol, such as sandwich immunoassays. Application of the platform is demonstrated using a multiplexed electrochemical immunoassay based on capture at the electrode surface of magnetic particles labelled with horseradish peroxidase and detection antibody. The multiplexed assay protocol is completed in less than 30 mins and results in detection of eight proteins associated with prostate cancer. The approach presented can be used to automate and simplify high‐throughput screening campaigns, such as detection of multiple biomarkers in patient samples.  相似文献   

5.
6.
Y Zhang  Y Tang  YH Hsieh  CY Hsu  J Xi  KJ Lin  X Jiang 《Lab on a chip》2012,12(17):3012-3015
This work reports an integrated platform combining localized-surface plasmon resonance (LSPR) and microfluidic chips to carry out multiplexed and label-free protein analysis. We fabricated an optical bench to enable detection using only a laboratory UV-Vis spectrophotometer. This assay not only improves throughput, but also allows quantitative analysis.  相似文献   

7.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

8.
Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microscopic counting for simultaneous quantification of multiple targets. A set of target-specific fluorescence-activable SPs are designed, which allows establishment of a novel multiplexed LAMP strategy for simultaneous detection of multiple cDNA targets. The digital multiplexed LAMP assay is thus developed by implementing the LAMP reaction using a droplet microfluidic chip coupled to a droplet counting microwell chip. The droplet counting system allows rapid and accurate counting of the numbers of total droplets and the positive droplets by collecting multi-color fluorescence images of the droplets in a microwell. The multiplexed dLAMP assay was successfully demonstrated for the quantification of HCV and HIV cDNA with high precision and detection limits as low as 4 copies per reaction. We also verified its potential for simultaneous digital assay of HCV and HIV RNA in clinical plasma samples. This multiplexed dLAMP technique can afford a useful platform for highly sensitive and specific detection of nucleic acids of viruses and other pathogens, enabling rapid diagnosis and prevention of infectious diseases.

The development of multiplexed dLAMP with scorpion-shaped probes and fluorescence microscopic counting affords simultaneous digital quantification of multiple virus RNAs.  相似文献   

9.
Shao C  Kendall EL  Devoe DL 《Lab on a chip》2012,12(17):3142-3149
Studies of lipid rafts, ordered microdomains of sphingolipids and cholesterol within cell membranes, are essential in probing the relationships between membrane organization and cellular function. While in vitro studies of lipid phase separation are commonly performed using spherical vesicles as model membranes, the utility of these models is limited by a number of factors. Here we present a microfluidic device that supports simultaneous electrical measurements and confocal imaging of on-chip bilayer lipid membranes (BLMs), enabling real-time multi-domain imaging of membrane organization. The chips further support closed microfluidic access to both sides of the membrane, allowing the membrane boundary conditions to be rapidly changed and providing a mechanism for dynamically adjusting membrane curvature through application of a transmembrane pressure gradient. Here we demonstrate the platform through the study of dynamic generation and dissolution of ordered lipid domains as membrane components are transported to and from the supporting annulus containing solvated lipids and cholesterol.  相似文献   

10.
Kim P  Lee SE  Jung HS  Lee HY  Kawai T  Suh KY 《Lab on a chip》2006,6(1):54-59
We present simple soft lithographic methods for patterning supported lipid bilayer (SLB) membranes onto a surface and inside microfluidic channels. Micropatterns of polyethylene glycol (PEG)-based polymers were fabricated on glass substrates by microcontact printing or capillary moulding. The patterned PEG surfaces have shown 97 +/- 0.5% reduction in lipid adsorption onto two dimensional surfaces and 95 +/- 1.2% reduction inside microfluidic channels in comparison to glass control. Atomic force microscopy measurements indicated that the deposition of lipid vesicles led to the formation of SLB membranes by vesicle fusion due to hydrophilic interactions with the exposed substrate. Furthermore, the functionality of the patterned SLBs was tested by measuring the binding interactions between biotin (ligand)-labeled lipid bilayer and streptavidin (receptor). SLB arrays were fabricated with spatial resolution down to approximately 500 nm on flat substrate and approximately 1 microm inside microfluidic channels, respectively.  相似文献   

11.
12.
Lipase (Pseudomonas sp.) was immobilized in collagen membrane and used for the measurement of neutral lipids. The determination system for lipids consisted of a lipase-collagen membrane reactor and glass electrodes. Neutral lipids were hydrolyzed to fatty acids and glycerol by immobilized lipase. The liberated protons were determined potentiometrically by using glass electrodes. A linear relationship was obtained between the logarithm of lipid concentrations and potential differences. The measurement gave results comparable to a conventional assay and was found to be applicable to the assay of neutral lipids in sera. The relative error of the determination by this system was within 4%.  相似文献   

13.
There is increasing interest in using microalgae as a lipid feedstock for the production of biofuels. Lipids used for these purposes are triacylglycerols that can be converted to fatty acid methyl esters (biodiesel) or decarboxylated to “green diesel.” Lipid accumulation in most microalgal species is dependent on environmental stress and culturing conditions, and these conditions are currently optimized using slow, labor-intensive screening processes. Increasing the screening throughput would help reduce the development cost and time to commercial production. Here, we demonstrated an initial step towards this goal in the development of a glass/poly(dimethylsiloxane) (PDMS) microfluidic device capable of screening microalgal culturing and stress conditions. The device contained power-free valves to isolate microalgae in a microfluidic growth chamber for culturing and stress experiments. Initial experiments involved determining the biocompatibility and culturing capability of the device using the microalga Tetraselmis chuii. With this device, T. chuii could be successfully cultured for up to 3 weeks on-chip. Following these experiments, the device was used to investigate lipid accumulation in the microalga Neochloris oleabundans. It was shown that this microalga could be stressed to accumulate cytosolic lipids in a microfluidic environment, as evidenced with fluorescence lipid staining. This work represents the first example of microalgal culturing in a microfluidic device and signifies an important expansion of microfluidics into the biofuels research arena.  相似文献   

14.
Monodisperse gas microbubbles, encapsulated with a shell of photopolymerizable diacetylene lipids and phospholipids, were produced by microfluidic flow focusing, for use as ultrasound contrast agents. The stability of the polymerized shell microbubbles against both aggregation and gas dissolution under physiological conditions was studied. Polyethylene glycol (PEG) 5000, which was attached to the diacetylene lipids, was predicted by molecular theory to provide more steric hindrance against aggregation than PEG 2000, and this was confirmed experimentally. The polymerized shell microbubbles were found to have higher shell-resistance than nonpolymerizable shell microbubbles and commercially available microbubbles (Vevo MicroMarker). The acoustic stability under 7.5 MHz ultrasound insonation was significantly greater than that for the two comparison microbubbles. The acoustic stability was tunable by varying the amount of diacetylene lipid. Thus, our polymerized shell microbubbles are a promising platform for ultrasound contrast agents.  相似文献   

15.
A new method to tailor liposome size and size distribution in a microfluidic format is presented. Liposomes are spherical structures formed from lipid bilayers that are from tens of nanometers to several micrometers in diameter. Liposome size and size distribution are tailored for a particular application and are inherently important for in vivo applications such as drug delivery and transfection across nuclear membranes in gene therapy. Traditional laboratory methods for liposome preparation require postprocessing steps, such as sonication or membrane extrusion, to yield formulations of appropriate size. Here we describe a method to engineer liposomes of a particular size and size distribution by changing the flow conditions in a microfluidic channel, obviating the need for postprocessing. A stream of lipids dissolved in alcohol is hydrodynamically focused between two sheathed aqueous streams in a microfluidic channel. The laminar flow in the microchannel enables controlled diffusive mixing at the two liquid interfaces where the lipids self-assemble into vesicles. The liposomes formed by this self-assembly process are characterized using asymmetric flow field-flow fractionation combined with quasi-elastic light scattering and multiangle laser-light scattering. We observe that the vesicle size and size distribution are tunable over a mean diameter from 50 to 150 nm by adjusting the ratio of the alcohol-to-aqueous volumetric flow rate. We also observe that liposome formation depends more strongly on the focused alcohol stream width and its diffusive mixing with the aqueous stream than on the sheer forces at the solvent-buffer interface.  相似文献   

16.
Herein we present a novel way to create arrays of different proteins or lipid vesicles using a crossed microfluidic device. The concept relies on the combination of I) a designated two-step surface chemistry, which allows activation for subsequent binding events, and II) crossing microfluidic channels for the local functionalization by separated laminar streams. Besides its simplicity and cost efficiency, this concept has the advantage that it keeps the proteins in a hydrated environment throughout the experiment. We have demonstrated the feasibility of such a device to create a chessboard pattern of different fluorescently labeled lipid vesicles, which offers the possibility to contain biomolecules, drugs or membrane proteins.  相似文献   

17.
It is believed that a lipid layer forms the outer layer of the pre-ocular tear film and this layer helps maintain tear film stability by lowering its surface tension. Proteins of the aqueous layer of the tear film (beneath the lipid layer) may also contribute to reducing surface tension by adsorbing to, or penetrating the lipid layer. The purpose of this study was to compare the penetration of lysozyme, a tear protein, into films of meibomian lipids and phospholipids held at different surface pressures to determine if lysozyme were part of the surface layer of the tear film. Films of meibomian lipids or phospholipids were spread onto the surface of a buffered aqueous subphase. Films were compressed to particular pressures and lysozyme was injected into the subphase. Changes in surface pressure were monitored to determine adsorption or penetration of lysozyme into the surface film. Lysozyme penetrated a meibomian lipid film at all pressures tested (max = 20 mN/m). It also penetrated phosphatidylglycerol, phosphatidylserine or phosphatidylethanolamine lipid films up to a pressure of 20 mN/m. It was not able to penetrate a phosphatidylcholine film at pressures ≥10 mN/m irrespective of the temperature being at 20 or 37 °C. However, it was able to penetrate it at very low pressures (<10 mN/m). Epifluorescence microscopy showed that the protein either adsorbs to or penetrates the lipid layer and the pattern of mixing depended upon the lipid at the surface. These results indicate that lysozyme is present at the surface of the tear film where it contributes to decreasing the surface tension by adsorbing and penetrating the meibomian lipids. Thus it helps to stabilize the tear film.  相似文献   

18.
An unappreciated aspect of many single-molecule techniques is the need for an inert surface to which individual molecules can be anchored without compromising their biological integrity. Here, we present new methods for tethering large DNA molecules to the surface of a microfluidic sample chamber that has been rendered inert by the deposition of a supported lipid bilayer. These methods take advantage of the "bio-friendly" environment provided by zwitterionic lipids, but still allow the DNA molecules to be anchored at fixed positions on the surface. We also demonstrate a new method for constructing parallel arrays of individual DNA molecules assembled at defined positions on a bilayer-coated, fused silica surface. By using total internal reflection fluorescence microscopy to visualize the arrays, it is possible to simultaneously monitor hundreds of aligned DNA molecules within a single field-of-view. These molecular arrays will significantly increase the throughput capacity of single-molecule, fluorescence-based detection methods by allowing parallel processing of multiple individual reaction trajectories.  相似文献   

19.
A multiplexed assay strategy was developed for the detection of nucleic acid hybridization. It is based on fluorescence resonance energy transfer (FRET) between gold nanoparticles (AuNPs) and multi-sized quantum dots (QDs) deposited on the surface of silica photonic crystal beads (SPCBs). The SPCBs were first coated with a three-layer primer film formed by the alternating adsorption of poly(allylamine hydrochloride) and poly(sodium 4-styrensulfonate). Probe DNA sequences were then covalently attached to the carboxy groups at the surface of the QD-coated SPCBs. On addition of DNA-AuNPs and hybridization, the fluorescence of the donor QDs is quenched because of the close proximity of the AuNPs. However, the addition of target DNA causes a recovery of the fluorescence of the QD-coated SPCBs, thus enabling the quantitative assay of hybridized DNA. Compared to fluorescent dyes acting as acceptors, the use of AuNPs results in much higher quenching efficiency. The multiplexed assay displays a wide linear range, high sensitivity, and very little cross-reactivity. This work, where such SPCBs are used for the first time in a FRET assay, is deemed to present a new and viable approach towards high-throughput multiplexed gene assays.
Figure
A novel fluorescence energy transfer system was constructed for the multiplexed hybridization assay using gold nanoparticles and quantum dot conjugates on silica photonic crystal beads  相似文献   

20.
Li Q  Zhang K  Wang T  Zhou X  Wang J  Wang C  Lin H  Li X  Lu Y  Huang G 《The Analyst》2012,137(16):3760-3766
Multiplexed analysis allows researchers to obtain high-density information with minimal assay time, sample volume and cost. Currently, microcarrier or particle-based approaches for multiplexed analysis involve complicated or expensive encoding and decoding processes. In this paper, a novel optical encoding technique based on nano-silicon dioxide film is presented. Microcarriers composed of thermally grown silicon dioxide (SiO(2)) film and monocrystalline silicon (Si) substrate were fabricated. The nano-silicon dioxide film exhibited unique surface color by low-coherence interference. Hence the colors can be used for encoding at least 100 microcarriers loaded with films of different thickness. We demonstrated that color-encoded microcarriers loaded with antigens could be used for multiplexed immunoassays to detect goat anti-human IgG, goat anti-mouse IgG and goat anti-rabbit IgG, with fluorescent detection as the interrogating approach. This microcarrier-based method also exhibited improved analytical performance compared with a microarray technique. This approach will provide new opportunities for multiplexed target assay development.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号