首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study reports a reinvestigation of background electrolyte selection strategy for performance improvement in CE‐LIF of peptides and proteins. This strategy is based on the employment of high concentrations of organic species in BGE possessing high buffer capacity and low specific conductivity in order to ensure excellent stacking preconcentration and separation resolution of fluorescently tagged peptides and proteins. Unlike universal UV detection, the use of such BGEs at high concentrations does not lead to degradation of LIF detection signals at the working excitation and emission wavelengths. At the same buffer ionic strength, pH and electric field, an “inorganic‐species‐free” BGE (or ISF BGE) for CE‐LIF of fluorescently labeled beta amyloid peptide Aβ 1–42 (a model analyte) offered a signal intensity and peak efficiency at least three‐times higher than those obtained with a conventional BGE normally used for CE‐LIF, while producing an electric current twice lower. Good peak performance (in terms of height and shape) was maintained when using ISF BGEs even with samples prepared in high‐conductivity phosphate buffer saline matrix. The advantageous features of such BGEs used at high concentrations over conventional ones in terms of high separation resolution, improved signal intensities, tuning of EOF magnitudes and minimization of protein adsorption on an uncoated fused silica capillary are demonstrated using Alexa‐488‐labelled trypsin inhibitor. Such BGE selection approach was applied for investigation of separation performance for CE‐LIF of ovalbumin labelled with different fluorophores.  相似文献   

2.
An in‐capillary 2, 2‐diphenyl‐1‐picrylhydrazyl (DPPH)‐CE‐the DAD (in‐capillary DPPH‐CE‐DAD) combined with reversed‐electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β‐CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p‐coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH‐CE‐DAD method. Sensitivity was enhanced under reversed‐electrode polarity stacking mode and 10‐ to 31‐fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in‐capillary DPPH‐CE‐DAD method combined with reversed‐electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products.  相似文献   

3.
Multiple labeling of nucleic acids by intercalative dyes is a promising method for ultrasensitive nucleic acid assays. The properties of the fast dissociation and instability of dye–DNA complexes may prevent from their wide applications in CE‐LIF nucleic acid analysis. Here, we describe an optimum CE focusing method by using appropriately paired sample and separation buffers, Tris‐glycine buffer and Tris‐glycine‐acetic acid buffer. The developed method was applied in both uncoated and polyacrylamide coated fused‐silica capillary‐based CE‐LIF analysis while the sample and separation buffers were conversely used. The complexes of intercalative dye benzoxazolium‐4‐pyridinium dimer and dsDNA were greatly focused (separation efficiency: 1.8 million theoretical plates per meter) by transient isotachophoresis mechanism in uncoated capillary, and moderately focused by transient isotachophoresis in combination of field amplified sample stacking and further stabilized by the paired buffer in polyacrylamide coated capillary. Based on the developed focusing strategy, an ultrasensitive DNA assay was developed for quantitation of calf thymus dsDNA (from 0.02 to 2.14 pM). By the use of an excitation laser power as low as 1 mW, the detection limits of calf thymus dsDNA (3.5 kb) are 7.9 fM in concentration and 2.4×10?22 mol (150 molecules) in mass. We further demonstrate that the non‐gel sieving CE‐LIF analysis of DNA fragments can be enhanced by the same strategy. Since the presented strategy can be applied to uncoated and coated capillaries and does not require special device, it is also reasonable to extend to the applications in chip‐based CE DNA analysis.  相似文献   

4.
The measurement of γ‐aminobutyric acid (GABA) is suitable for investigating various neurological disorders. In this study, a sensitive and selective method for free GABA quantification in cerebrospinal fluid (CSF) has been standardised. This method is based on CE with LIF detection using 4‐fluoro‐7‐nitrobenzo‐2‐oxa‐1,3‐diazole (NBD‐F) as a derivatisating agent. The reaction conditions (NBD‐F concentration, pH, temperature and reaction time) and the electrophoretic parameters (run buffer composition and pH and separation voltage) were optimised to obtain the maximum derivatisation efficiency and electrophoretic resolution. The best resolution was obtained using 200 mM sodium borate, 10 mM SDS, 8.5 mM β‐CD, pH 10 and 20 kV voltage. The method was linear in the concentration range of 2.5–1000 nM with good inter‐ and intra‐assay precision values. The effects of CSF handling on free GABA concentrations were also evaluated. Our results show that the time delay between CSF collection and freezing strongly increases the CSF GABA values. Age‐related reference values were established in 55 paediatric controls. The influence of antiepileptic therapy on free CSF GABA was studied in 38 neuropaediatric patients. Significantly, higher GABA values were obtained in patients taking valproic acid or vigabatrin therapy, which are antiepileptic drugs that modulate GABA metabolism.  相似文献   

5.
Precise measurement of nitric oxide (NO) is of great importance to understand the function of NO in liver and the mechanism of liver injury. 8‐(3’,4’‐Diamino phenyl)‐3,5‐(2‐hydroxyphenyl)‐dimethylene pyrrole (BOPB), a fluorescent probe in the red region (>600 nm) newly developed in our group, has good photostability and excitation/emission wavelength of 622/643 nm matching well with commercial 635 nm semiconductor laser of CE‐LIF detection. Therefore, BOPB was used in CE‐LIF for the determination of NO in mice liver. Both derivatization and separation conditions were optimized. Derivatization reaction of BOPB and NO was carried out in pH 7.4 PBS buffer at 35°C for 12 min and the separation of NO derivative of BOPB (BOPB‐T) was achieved within 7.0 min in pH 9.0 running buffer containing 15 mM H3BO3–NaOH and 15 mM SDS. Good linearity was found in the range of 1.0 × 10?9–5.0 × 10?7 M with the LOD of 0.02 nM. The proposed method was applied to the analysis of NO in real samples, and NO concentration was obviously increased in acute liver injury of mice. Compared to existing derivatization‐based CE‐LIF methods for NO, this method has lower LOD and less background interference owing to detection wavelength of BOPB in the red region.  相似文献   

6.
Laser‐induced fluorometry (LIF) has achieved the detection of single molecules, which ranks it among the most sensitive of detection techniques, whereas capillary electrophoresis (CE) is known as a powerful separation method with resolution that is beyond the reach of many other types of chromatography. Therefore, a coupling of LIF with CE has established an unrivaled analytical technique in terms of sensitivity and resolution. CE‐LIF has demonstrated excellent performance in bioanalytical chemistry for the high‐resolution separation and highly sensitive detection of DNAs, proteins, and small bioactive molecules. This review describes the CE‐LIF methods developed by the author's group that include indirect and direct detection using diode lasers, post‐column derivatization, and Hadamard transformation, as well as applications to the binding assays of specific DNA immunoassays of proteins and to the determination of anticancer drugs.  相似文献   

7.
8‐Hydroxy‐2′‐deoxyguanosine (8‐OHdG) is one of the major forms of oxidative DNA damage, and is commonly analyzed as an excellent marker of DNA lesions. The purpose of this study was to develop a sensitive method to accurately and rapidly quantify the 8‐OHdG by using CE‐LIF detection. The method involved the use of specific antibody to detect the DNA lesion (8‐OHdG) and consecutive fluorescence labeling. Next, urinary 8‐OHdG fluorescently labeled along with other constituents were resolved by capillary electrophoretic system and the lesion of interest was detected using a fluorescence detector. The limit of detection was 0.18 fmol, which proved sufficient sensitivity for detection and quantification of 8‐OHdG in untreated urine samples. The relative standard deviation was found to be 11.32% for migration time and 5.52% for peak area. To demonstrate the utility of this method, the urinary concentration of 8‐OHdG in an Alzheimer's transgenic mouse model was determined. Collectively, our results indicate that this methodology offers great advantages, such as high separation efficiency, good selectivity, low limit of detection, simplicity and low cost of analysis.  相似文献   

8.
A simple and rapid method has been developed for the analysis of anthracycline antibiotics doxorubicin (DOX) and daunorubicin (DAU) in human serum using mirochip-based capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. In this study, method development included studies of the effect of buffer pH, buffer concentration, organic solvents and separation voltage on sensitivity and separation efficiencies for the CE separation of DOX and DAU. Acetonitrile was found to have significantly improved the sensitivity and separation efficiency. The method was validated with regard to reproducibilities, linearity and limit of detection (LOD). The optimum electrophoretic separation conditions were 10 mM sodium tetraborate buffer at pH 9.5 with 40% acetonitrile (V/V) and a separation voltage of 2.1 kV. DOX and DAU were separated in 60 s under the optimum separation conditions. Linear relationships were obtained between the concentration and peak area (or peak height) in the 1–75 µg mL− 1 range and with the detection limits of 0.3 and 0.2 μg mL− 1 for DOX and DAU, respectively. The stability of both migration time and peak height of the analytes showed relative standard deviations of less than 5% (n = 9). The potential of this method was verified by spiking a human serum sample with the two drugs and analyzing the recovery ratios.  相似文献   

9.
Precolumn derivatization of six short‐chain aliphatic amines by a near‐infrared dye, 1‐(ε‐succinimydyl‐hexanoate)‐1′‐methyl‐3,3,3′,3′‐tetramethyl‐indocarbocyanine‐5,5′‐ disulfonate potassium (MeCy5‐OSu), followed by MEKC–CE–LIF detection has been developed as a method for the determination of aliphatic amines in environmental water and food. Optimum derivatization was operated nicely in pH 9.0 borate buffer at 20°C for 30 min. Well separated peaks were observed with a pH 9.5 BGE containing 10 mmol L?1 phosphoric acid, 20 mmol L?1 SDS, and 7% methanol buffered with 1.0 mol L?1 NaOH. The separation procedure was rapidly achieved within 11 min and the matrix interferences could be effectively eliminated. A linear calibration graph was obtained for 5–200 nmol L?1 analytes with a correlation coefficient in the range 0.9933–0.9995 for amines. This method was successfully utilized to determine aliphatic amines in lake, sewage water, and red wine with recoveries ranging from 96.4 to 105% and the RSDs ranging from 0.9 to 2.9%. Near‐infrared, LIF‐detector‐compatible MeCy5‐OSu was proved suitable for the accurate, sensitive, and rapid separation and determination of aliphatic amines in water and food samples.  相似文献   

10.
A simple and sensitive method for determination of free amino acids in milk by microchip electrophoresis (MCE) coupled with laser‐induced fluorescence (LIF) detection was developed. Seven kinds of standard amino acids were derivated with sulfoindocyanine succinimidyl ester (Cy5) and then perfectly measured by MCE‐LIF within 150 s. The parameters of MCE separation were carefully investigated to obtain the optimal conditions: 100 mmol·L?1 sodium borate solution (pH 10.0) as running buffer solution, 0.8 kV as injection voltage, 2.2 kV as separation voltage etc. The linear range of the detection of amino acids was from 0.01 µmol·L?1 to 1.0 µmol·L?1 and the detection limit was as low as about 1.0 nmol·L?1. This MCE‐LIF method was applied to the measurements of free amino acids in actual milk samples and satisfactory experimental results were achieved.  相似文献   

11.
A CZE with near‐infrared (NIR) LIF detection method has been developed for the analysis of six low molecular weight thiols including glutathione, homocysteine, cysteine, γ‐glutamylcysteine, cysteinylglycine, and N‐acetylcysteine. For this purpose, a new NIR fluorescent probe, 1,7‐dimethyl‐3,5‐distyryl‐8‐phenyl‐(4'‐iodoacetamido)difluoroboradiaza‐s‐indacene was utilized as the labeling reagent, whose excitation wavelength matches the commercially available NIR laser line of 635 nm. The optimum procedure included a derivatization step of the free thiols at 45°C for 25 min and CZE analysis conducted within 14 min in the running buffer containing 16 mmol/L pH 7.0 sodium citrate and 60% v/v ACN. The LODs (S/N = 3) ranged from 0.11 nmol/L for N‐acetylcysteine to 0.31 nmol/L for γ‐glutamylcysteine, which are better than or comparable to those reported with other derivatization‐based CE‐LIF methods. As the first trial of NIR CE‐LIF method for thiol determination, the practical application of the proposed method has been validated by detecting thiols in cucumber and tomato samples with recoveries of 96.5–104.3%.  相似文献   

12.
Herein, we report a new CE method to measure adenine nucleotides adenosine 5′‐triphosphate, adenosine 5′‐diphosphate, and adenosine 5′‐monophosphate in red blood cells. For this purpose, 20 mmol/L sodium acetate buffer at pH 3.80 was used as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of 25 kV and an overimposed pressure of 0.2 psi from inlet to outlet. A rapid separation of these analytes in less than 1.5 min was obtained with a good reproducibility for intra‐ and inter‐assay (CV<4 and 8%, respectively) and an excellent analytical recovery (from 98.3 to 99%). The applicability of our method was proved by measuring adenine nucleotides in red blood cells.  相似文献   

13.
An analytical method, based on a column coupling capillary ITP and CZE in a hydrodynamically closed separation mode hyphenated with the detection in the modular arrangement, was developed in this work. Analytical possibilities of this approach are demonstrated on the direct and ultrasensitive quantitative determination of quinine (QUI) in diluted real multicomponent ionic matrices (beverages, urine). The detection cell interface, with the rectangular arrangement of the optical channels inside, connected the separation capillary with the LIF detector via optical fibers in the on‐column detection arrangement. ITP enabled the direct large volume (30 μL) injections of the diluted real matrices with an on‐line sample pretreatment (preseparation, preconcentration) so that no external sample preparation (except for the dilution) was necessary for the separation of the analyte in the multicomponent ionic matrices. Due to the ITP sample preconcentration and intrinsic sensitivity of the LIF detection, very low concentration LOD (as low as 77 pg/mL), were reached at the same time. This was ca. two orders lower than the corresponding LOD achieved by the same 2D separation system with UV absorbance detection. Compared to the single column CE‐LIF methods applied for this model analyte and matrix, this method was found to be superior in terms of concentration LOD, with acceptable selectivity and benefits of the on‐line sample preparation. A food control and bioanalytical application clearly illustrates great practical possibilities and routine use of the proposed modular ITP–CZE–LIF technique.  相似文献   

14.
Micro‐RNAs (miRNAs) are small, endogenous, singlestranded, and noncoding RNAs. The miRNAs have been found to perform important functions in many cellular processes, such as development, proliferation, differentiation, and apoptosis. Circulating miRNAs have been proposed as emerging biomarkers in diseases such as cancer, diabetes, and cardiovascular disease including acute myocardial infarction (AMI). In this study, we developed CE with LIF (CE‐LIF) using fluorescence‐labeled DNA probe for determination of low abundance miRNA in cell extracts. The target miRNA is miRNA‐499, a biomarker candidate of AMI with low abundance in biological samples. In order to measure the trace level of miRNA, we optimized the hybridization conditions such as hybridization time, temperature, and buffer solution. The highest fluorescence intensity of the hybridized miRNA‐499 was found when hybridization was conducted at 40°C in 50 mM Tris‐acetate (pH 8.0) buffer containing 50 mM NaCl, and 10 mM EDTA for 15 min. The hybridized miRNA‐499 was detected in cultured H9c2 cardiomyoblast cells and the analysis of miRNA‐499 was completed within 1 h using CE‐LIF. These results showed the potential of CE for fast, specific, and sensitive high‐throughput analysis of low‐abundance miRNAs in cell extracts, biofluids, and tissues.  相似文献   

15.
A high‐speed separation method of capillary MEKC with LIF detection had been developed for separation and determination of amino acids in laver. The CE system comprised a manual slotted‐vial array (SVA) for sample introduction that could improve the separation efficiency by reducing injection volume. Using a capillary with 80 mm effective separation length, the separation conditions for amino acids were optimized. Applied with the separation electric field strength of 300 V/cm, the ten amino acids could be completely separated within 2.5 min with 10 mol/L Na2HPO4–NaOH buffer (pH = 11.5) including 30 mmol/L SDS. Theoretical plates for amino acids ranged from 72 000 to 40 000 (corresponding to 1.1–2.0 μm plate heights) and the detection limits were between 25 and 80 nmol/L. Finally, this method was applied to analyze the composition of amino acids in laver and eight known amino acids could be found in the sample. The contents of five amino acids, tyrosine, glutamic acid, glycine, lysine, and aspartic acid that could be completely separated in real sample were determined. The recoveries ranged from 82.3% to 123% that indicated the good reliability for this method in laver sample analysis.  相似文献   

16.
An online dynamic pH junction preconcentration method was developed for quantification of 5‐aminolevulinic acid (ALA) by CE with the separation time less than 6 min. The optimal dynamic pH junction of ALA was carried out between pH 9.3 borate buffer (BGE, 40 mM) and pH 2.5 phosphate buffer (sample matrix, 40 mM) when 4.1 cm of sample plug was hydrodynamically injected into an uncoated fused‐silica capillary (48.5 cm in length, id of 50 μm). If a 24 kV separation voltage was applied, the calibration curve of ALA peak area (200 nm) showed good linearity (R2 = 0.9991) ranging from 0.01 to 6.5 mg/mL. The reproducibility of this system was excellent with RSDs (n = 10) of 2.5% for peak area response and 0.6% for migration time at ALA concentration of 0.5 mg/mL. The LOD was evaluated as 1.0 μg/mL (S/N > 3). Compared to conventional CE procedure, the sensitivity was successfully improved over 50‐fold. The analytical results of pharmaceutical formulations show a good agreement with those by HPLC (r = 0.94).  相似文献   

17.
This paper presents a capillary electrophoresis method, developed for the detection, in human urine, of beta‐adrenergic agents and phenolalkylamines. The electrophoretic separation is achieved in less than 10 min and is based on the use of CEofix kit, for the dynamic capillary coating. The effects of accelerator buffer pH and separation voltage were investigated. The optimum buffer pH was found to be 2.5 for beta2‐agonists and 6.2 for beta‐blockers and phenoalkylamines with a separation voltage of 15 kV. Urine samples spiked with the compounds here studied were treated according to the standard procedure (SPE and evaporation to dryness) and analyzed by CE interfaced with an UV diode‐array, set at 195 and 210 nm. The quantitative validation results, obtained analyzing samples at three different concentrations, show a good precision of peak areas that do not exceed 5% for intra‐day assays and 10% for inter‐day assays. Good linearity (r2 > 0.995) was obtained within the 50–500 ng/mL concentration range. The qualitative validation data show a relative migration times (MTs) variation lower than 1%. The analytes were clearly distinguishable in urine, with LOD and LOQ in the range of 10–80 and 40–100 ng/mL, respectively.  相似文献   

18.
In this study, a new CE method, employing a binary system of trimethyl‐β‐CD (TM‐β‐CD) and a chiral amino acid ester‐based ionic liquid (AAIL), was developed for the chiral separation of seven 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (NSAIDs). In particular, the enantioseparation of ibuprofen, ketoprofen, carprofen, indoprofen, flurbiprofen, naproxen, and fenoprofen was improved significantly by supporting the BGE with the chiral AAIL l ‐alanine tert butyl ester lactate (l ‐AlaC4Lac). Parameters, such as concentrations of TM‐β‐CD and l ‐AlaC4Lac, and buffer pH, were systematically examined in order to optimize the chiral separation of each NSAID. It was observed that the addition of the AAIL into the BGE improved both resolution and efficiency significantly. After optimization of separation conditions, baseline separation (Rs>1.5) of five of the analytes was achieved in less than 11 min, while the resolution of ibuprofen and flurbiprofen was approximately 1.2. The optimized enantioseparation conditions for all analytes involve a BGE of 5 mM sodium acetate/acetic acid (pH 5.0), an applied voltage of 30 kV, and a temperature of 20°C. In addition, the results obtained by computing the %‐RSD values of the EOF and the two enantiomer peaks, demonstrated excellent run‐to‐run, batch‐to‐batch, and day‐to‐day reproducibilities.  相似文献   

19.
We report here the development of copper‐plated screen‐printed carbon electrodes (designated as Cu‐SPE) to employ as electrochemical detectors for the determination of sugars by capillary electrophoresis (CE). A simple end‐column amperometric detection system with easily exchangeable (or even disposable) electrode and capillary in CE is described in this study. A complex alignment procedure was not required in this system based on the end‐column electrode arrangement using an 85 cm length and 20 μm (i.d.) capillary. The optimized separation voltage and applied potential were 9 KV and 0.4 V (vs. Ag/AgCl), respectively, for the detection of sugars using the Cu‐SPE. Good resolution was obtained by this proposed system with migration times of 28.8, 29.5, 29.9, 30.7, 31.2, and 32.0 min for galactose, glucose, arabinose, fructose, xylose, and ribose, respectively.  相似文献   

20.
A method based on poly (methacrylic acid‐co‐ethylene glycol dimethacrylate) monolith microextraction and octadecylphosphonic acid‐modified zirconia‐coated CEC followed by field‐enhanced sample injection preconcentration technique was proposed for sensitive CE‐UV analysis of six antidepressants (doxepin, clozapine, imipramine, paroxetine, fluoxetine and chlorimipramine) in human plasma and urine. A poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic capillary column was introduced for the extraction of antidepressants from urine and plasma samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the desorption solvent, which normally provided an excellent medium to ensure direct compatibility for field‐enhanced sample injection in CE, was analyzed by CE directly. By the use of alkylphosphonate‐modified zirconia‐coated CEC for separation of the basic compounds of antidepressants, high separation efficiency and resolution were achieved because that both hydrophobic interaction between analytes and alkylphosphonate‐modified zirconia coat and electrophoretic effect work on the separation of antidepressants. The best separation was achieved using a buffer composed of 0.3 M ammonium acetate (adjusted to pH 4.5 with 1 M acetic acid) and 35% ACN v/v, with a temperature and voltage of 20°C and 20 kV, respectively. By applying both preconcentration procedures, LODs of 11.4–51.5 and 3.7–17.0 μg/L were achieved for the six antidepressants in human plasma and urine, respectively. Excellent method of reproducibility was found over a linear range of 50–5000 μg/L in plasma and urine sample.  相似文献   