首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
A new heterodinuclear Fe(III)Zn(II) complex which mimics the active site of the hydrolytic enzyme red kidney bean purple acid phosphatase was synthesized and characterized by IR, CHN and X-ray crystallographic analyses. This complex, [FeIIIZnII(μ-OH)bpbpmp-CH3](ClO4)2, containing the ligand (H2bpbpmp-CH3 = {2-[bis(2-pyridylmethyl)aminomethyl]-6-[(2-hydroxy-5-methylbenzyl) (2-pyridyl-methyl) aminomethyl]-4-methyl-phenol}) was employed in the construction of a biomimetic sensor and used in the determination of rosmarinic acid in plant extract samples. The response parameters and optimization of the biomimetic sensor design were evaluated. The best performance of this sensor was obtained for 75:15:10% (w/w/w) of the graphite powder:nujol:Fe(III)Zn(II) complex, 0.1 mol L−1 phosphate buffer solution (pH 7.5), 1.19 × 10−4 mol L−1 hydrogen peroxide with frequency, pulse amplitude, and scan increment at 30 Hz, 100 mV, and 0.6 mV, respectively. The rosmarinic acid concentration was linear in the range of 2.98 × 10−5 to 3.83 × 10−4 mol L−1 (r = 0.9991) with a detection limit of 2.30 × 10−6 mol L−1. This biomimetic sensor demonstrated long-term stability (300 days; 900 determinations) and reproducibility, with a relative standard deviation of 12.0%. The recovery study of rosmarinic acid in plant extract samples gave values from 90.3 to 98.3% and the concentrations determined showed agreement when compared with those obtained using capillary electrophoresis at the 95% confidence level.  相似文献   

2.
The synthesis and characterization of new dinuclear MnIII and tetranuclear CuII complexes, [HL1Mn(DMSO)]2 (1) and [H2L2Cu2(MeO)2]2 (2), are reported (H4L1 = 2-hydroxy-N-[2-({2-[(2-hydroxybenzoyl)amino]ethyl}amino)ethyl]benzamide and H4L2 = 2-hydroxy-N-[3-({3-[(2-hydroxybenzoyl)amino]propyl}(methyl)amino)propyl]benzamide). Single crystal X-ray structures have been determined for 1 and 2. In 1 only one of the two amide functions of H4L1 is deprotonated in addition to the phenol ones, while in 2 all the amide functions of H4L2 are protonated and none of the potential nitrogen donors (amide and amine) is involved in the coordination to copper. HL1 and H2L2 do not play the role of compartmental ligands and do not wrap around one Mn and one Cu ion, respectively, but embrace two metal centers yielding, with the respective assistance of auxiliary DMSO and methoxo ligands, dinuclear manganese and tetranuclear copper complexes, respectively. 1 includes two well isolated MnIII ions (Mn?Mn′ = 7.33 Å) that do not interact magnetically. The intermolecular Mn?Mn″ distance along the 1D chains (10.17 Å) is also too large to allow extended magnetic interactions. The pairwise magnetic interactions between the copper(II) ions in the tetranuclear complex 2 are so large that the χMT product is already equal to zero at room temperature, implying that the antiferromagnetic interaction is around −1000 cm−1, as observed previously for di-μ-hydroxo–dicopper complexes.  相似文献   

3.
A new tetranuclear copper(II) complex which mimics the active site of catechol oxidase was synthesized and characterized by IR, CHN, electronic spectroscopic and 1H NMR methods. The title complex [Cu2(μ-OH)(bpbpmp-NO2)]2[ClO4]2 was employed in the construction of a novel biomimetic sensor and used in the determination of chlorogenic acid by square wave voltammetry. The performance and optimization of the resulting biomimetic sensor were studied in detail. The best response of this sensor was obtained for 75:15:10% (w/w/w) ratio of the graphite powder:nujol:Cu(II) complex, 0.1 mol L−1 phosphate buffer solution (pH 7.0), with frequency, pulse amplitude, and scan increment at 30 Hz, 100 mV, and 3.0 mV, respectively. The chlorogenic acid concentration was linear in the range of 5.0 × 10−6 to 1.45 × 10−4 mol L−1 (r = 0.9985) with a detection limit of 8.0 × 10−7 mol L−1. This biomimetic sensor demonstrated long-term stability (250 days; 640 determinations) and reproducibility, with a relative standard deviation of 10.0%. The recovery study of chlorogenic acid in coffee samples gave values from 93.2% to 106.1% and the concentrations determined showed good agreement when compared with those obtained using capillary electrophoresis at the 95% confidence level.  相似文献   

4.
In this article a new coated platinum Cu2+ ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylideneamino)phenyl)disufanyl)phenylimino) methyl)-4-methoxyphenol Schiff base (L1) as a new ionophore is described. This sensor has a wide linear range of concentration (1.2 × 10−7-1.0 × 10−1 mol L−1) and a low detection limit of 9.8 × 10−8 mol L−1of Cu(NO3)2. It has a Nernstian response with slope of 29.54 ± 1.62 mV decade−1 and it is applicable in the pH range of 4.0-6.0 without any divergence in potentioal. The coated electrode has a short response time of approximately 9 s and is stable at least for 3.5 months. The electrode shows a good selectivity for Cu2+ ion toward a wide variety of metal ions. The proposed sensor was successfully applied for the determination of Cu2+ ion in different real and environmental samples and as indicator electrode for potentiometric titration of Cu2+ ion with EDTA.  相似文献   

5.
A novel voltammetric sensor for O,O-dimethyl-(2,4-dichlorophenoxyacetoxyl)(3′-nitrophenyl)methinephosphonate (Phi-NO2) based on molecularly imprinted polymer (MIP) film electrode is constructed by using sol-gel technology. The sensor responds linearly to Phi-NO2 over the concentration range of 2.0 × 10−5 to 1.0 × 10−8 mol L−1 and the detection limit is 1.0 × 10−9 mol L−1 (S/N = 3). This sensor provides an efficient way for eliminating interferences from coexisting substances in the solution. The high sensitivity, selectivity and stability of the sensor demonstrates its practical application for a simple and rapid determination of Phi-NO2 in cabbage samples.  相似文献   

6.
A new PVC membrane electrode for manganese(II) ion based on a recently synthesized Schiff base of 5-[(4-nitrophenylazo)-N-hexylamine]salicylaldimine is reported. The electrode exhibits a Nernstian response for Mn2+ ions over a wide concentration range (4.0 × 10−7 to 1.8 × 10−2 mol L−1) with a slope of 30.1 (±1.0). The limit of detection is 1.0 × 10−7 mol L−1. The electrode has a fast response time (∼10 s), a satisfactory reproducibility and relatively long life time. The proposed sensor revealed good selectivities over a wide variety of other cations include hard and soft metals. This electrode could be used in a pH range of 4.5-7.5. It was used as an indicator electrode in potentiometric titration of manganese(II) ions with EDTA solution.  相似文献   

7.
Zhang Y  Zheng J 《Talanta》2008,77(1):325-330
An ionic liquid modified carbon paste electrode (IL/CPE) had been fabricated by using hydrophilic ionic liquid 1-amyl-3-methylimidazolium bromide ([AMIM]Br) as a modifier. The IL/CPE was characterized by scanning electron microscope and voltammetry. Electrochemical behavior of rutin at the IL/CPE had been investigated in pH 3.29 Britton-Robinson (B-R) buffer solution by cyclic voltammetry (CV) and square wave voltammetry (SWV). The experimental results suggested that the modified electrode exhibited an electrocatalytic activity toward the redox of rutin. The electron transfer coefficient (α) and the standard rate constant (ks) of rutin at the modified electrode were calculated. Under the selected conditions, the reduction peak current was linearly dependent on the concentration of rutin in the range of 4.0 × 10−8 to 1.0 × 10−5 mol L−1 (r = 0.9998), with a detection limit of 1.0 × 10−8 mol L−1 (S/N = 3). The relative standard deviation (R.S.D.) for six times successful determination of 8.0 × 10−7 mol L−1 rutin was 1.2%. The proposed method was applied to determine rutin in tablet and urine sample. In addition, the IL/CPE exhibited a distinct advantage of simple preparation, surface renewal, good reproducibility and good stability.  相似文献   

8.
Fei Wang  Xiaohan Wei  Shusheng Zhang 《Talanta》2010,80(3):1198-1204
The π-A isotherms and UV-vis spectra of the transferred films suggested that the monolayer of p-tert-butylthiacalix[4]arene can coordinate with Hg2+ at the air-water surface. From these observations, a glassy carbon electrode coated with Langmuir-Blodgett film of p-tert-butylthiacalix[4] arene as a new voltammetric sensor is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode and modified glassy carbon electrode using direct coating method, the Langmuir-Blodgett film-modified electrode can greatly improve the measuring sensitivity of Hg2+. Under the selected conditions, the Langmuir-Blodgett film-modified electrode in 0.1 mol L−1 H2SO4 + 0.01 mol L−1 KCl solution shows a linear voltammetric response for Hg2+ in the range of 5.0 × 10−10 to 1.5 × 10−7 mol L−1, with a detection limit of 2.0 × 10−10 mol L−1. The proposed method was also applied to determine Hg2+ in water samples (tap, lake and river water). In addition, the fabricated electrode exhibited a distinct advantage of simple preparation, non-toxicity, good reproducibility and good stability.  相似文献   

9.
A novel, simple, sensitive and precise spectrofluorimetric method was developed for measuring the melamine concentration in different milk batch samples. The method was based upon measuring the quenching of the luminescence intensity of the produced yellow colored ruthenium(II) carbonyl complex of the general formula [Ru(CO)2(L)] (where L = anion of tetradentate Schiff base). The Ru(II) complex exhibited characteristic luminescence band in the visible region. The remarkable quenching of the luminescence intensity of [Ru(CO)2(L)] complex by various concentrations of melamine was successfully used as a chemosensor for the assessment of melamine in different milk samples at λex = 400 nm and pH 7.4 in DMSO with a linear dynamic range 1.0 × 10−6 to 3.0 × 10−9 mol L−1 and lower detection limit (LOD) and quantification detection limit (QOD) of 3.3 × 10−10 and 1.0 × 10−9 mol L−1, respectively.  相似文献   

10.
A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be2+ determination. The complex of Be2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1, the ECL intensity had a linear relationship with the Be2+ concentrations, with the limit of detection of 2.35 × 10−11 mol L−1. This method was successfully used to detect Be2+ in real water samples.  相似文献   

11.
Mehretie S  Admassie S  Hunde T  Tessema M  Solomon T 《Talanta》2011,85(3):1376-1382
A sensitive and selective method was developed for the determination of N-acetyl-p-aminophenol (APAP) and p-aminophenol (PAP) using poly(3,4-ethylenedioxythiophene) (PEDOT)-modified glassy carbon electrode (GCE). Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical reaction of APAP and PAP at the modified electrode. Both APAP and PAP showed quasireversible redox reactions with formal potentials of 367 mV and 101 mV (vs. Ag/AgCl), respectively, in phosphate buffer solution of pH 7.0. The significant peak potential difference (266 mV) between APAP and PAP enabled the simultaneous determination both species based on differential pulse voltammetry. The voltammetric responses gave linear ranges of 1.0 × 10−6-1.0 × 10−4 mol L−1 and 4.0 × 10−6-3.2 × 10−4 mol L−1, with detection limits of 4.0 × 10−7 mol L−1 and 1.2 × 10−6 mol L−1 for APAP and PAP, respectively. The method was successfully applied for the determination of APAP and PAP in pharmaceutical formulations and biological samples.  相似文献   

12.
A novel flow injection chemiluminescence (FI-CL) sensor for determination of sulfadiazine (SDZ) using core–shell magnetic molecularly imprinted polymers (MMIPs) as recognition element is developed. Briefly, a hydrophilic MMIPs layer was produced at the surface of Fe3O4@SiO2 magnetic nanoparticles (MNPs) via combination of molecular imprinting and reversible stimuli responsive hydrogel. And it provided the MMIPs with excellent adsorption capacity and rapid adsorption rate due to the imprinted sites mostly situated on the surface of MMIPs. Then the prepared SDZ-MMIPs were packed into flow cell to establish a novel FI-CL sensor. The sensor provided a wide linear range for SDZ of 4.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.54 × 10−7 mol L−1. And the relative standard deviation (RSD) for the determination of 1.0 × 10−6 mol L−1 SDZ was 2.56% (n = 11). The proposed method was applied to determine SDZ in urine samples and satisfactory results were obtained.  相似文献   

13.
14.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry.  相似文献   

15.
A new piezoelectric quartz crystal (PQC) sensor using molecularly imprinted polymer (MIP) as sensing material has been developed for fast and onsite determination of pirimicarb in contaminated vegetables. Three MIPs particles have been prepared by conventional bulk polymerization (MIP-B) and precipitation polymerization in either acetonitrile (MIP-P1) or chloroform (MIP-P2). MIP-P2, with uniform spherical shape and mean diameter at about 50 nm, has shown the best performance as the sensing material for PQC sensor. The sensor fabricated with MIP-P2 can achieve a steady-state response within 5 min, a very short response time as compared to MIPs-coated PQC sensor reported in the literature. The sensor developed exhibits good selectivity (low response to those pesticides with similar structures to pirimicarb, such as atrazine, carbaryl, carbofuran and aldicarb) and high sensitivity to pirimicarb with a linear working range from 5.0 × 10−6 to 4.7 × 10−3 mol L−1 (following a regression equation (r = 0.9988) of −ΔF = 0.552 + 1.79 × 106 C), a repeatability (R.S.D., n = 5) of 4.3% and a detection limit (S/N = 3, n = 5) of 5 × 10−7 mol L−1. The MIP-coated PQC sensor developed is shown to provide a sensitive and fast method for onsite determination of pirimicarb in aqueous extract from contaminated vegetables with satisfactory recoveries from 96 to 103% and repeatability (R.S.D., n = 5) from 4.6 to 7.1% at pirimicarb concentrations ranging from 8.0 × 10−6 to 2.0 × 10−4 mol L−1.  相似文献   

16.
Boni AC  Wong A  Dutra RA  Sotomayor Mdel P 《Talanta》2011,85(4):2067-2073
A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min−1, a 75 μL sample loop, a 0.1 mol L−1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 × 10−6-6.3 × 10−3 mol L−1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone.  相似文献   

17.
Due to the high performance of glassy carbon in the aspects of mechanical strength, electrical conductivity and high corrosion resistance, etc., glassy carbon has been widely used in the electrochemistry. A new form of glassy carbon, glassy carbon microsphere, was utilized to couple with ionic liquid in preparing a new electrochemiluminescent platform for Ru(bpy)3Cl2. Room temperature ionic liquid has been proposed to be very interesting and efficient pasting binder to replace the non conductive organic binders for the fabrication of composite paste electrode. Attributed to the special characteristics of glassy carbon microspheres and room temperature ionic liquid [N-octylpyridium tetrafluoroborate (OPFP)], this new electrochemiluminescent sensor exhibited excellent electrochemiluminescent performance in Ru(bpy)32+ solution. We first found that fentanyl citrate could increase the ECL of Ru(bpy)32+, hence an ECL approach was developed for the determination of fentanyl citrate based on this glassy carbon microspheres based electrochemiluminescent platform with high sensitivity. Under the optimized conditions, the enhanced electrochemiluminescent intensity versus fentanyl citrate concentration was linear in the range of 1.0 × 10−8 to 1.0 × 10−4 mol L−1 with a detection limit of 8.5 × 10−9 mol L−1, and the relative standard deviation for 1.0 × 10−6 mol L−1 fentanyl citrate was 1.90% (n = 10). This protocol has extended the application scopes of glassy carbon material and promoted the application of glassy carbon microspheres in electroanalysis.  相似文献   

18.
A new thiacalix[4]arene based fluorescent sensor bearing two dansyl groups has been synthesized in cone conformation. In CH3CN:CH2Cl2 (1:1), the presence of Cu (II) induces the formation of a 1:1 metal:ligand complex, which exhibits increasing emission at 433 nm at the expense of the fluorescent emission of 1 centered at 504 nm. The detection limit of the sensor for Cu2+ is 2×10−7 mol L−1. For anion sensing, 1 shows a high selectivity for fluoride ions over other anions tested.  相似文献   

19.
Li M  Lee SH 《Talanta》2007,74(2):265-270
A simple, rapid flow injection chemiluminescence (FI-CL) method has been developed for selective determination of acenaphthylene (ACY), based on the CL produced in the reaction of tris(2,2′-bipyridine)ruthenium(III) (Ru(bipy)33+) and ACY in an acidic buffer solution. Under the optimum experimental conditions, the calibration curve was linear over the range 5.0 × 10−3 to 4.0 × 10−7 mol L−1 for ACY. The detection limit (S/N = 3) was 2.0 × 10−7 mol L−1 and the relative standard deviation of 10 replicate measurements was 2.3% for 5.0 × 10−5 mol L−1 of ACY. Selectivity of CL reaction of ACY from other 15 polycyclic aromatic hydrocarbons (PAHs) was investigated by flow injection method. The method was applied to determine the ACY content in soil.  相似文献   

20.
Hu YF  Zhang ZH  Zhang HB  Luo LJ  Yao SZ 《Talanta》2011,84(2):305-313
A sensitive and selective electrochemical sensor based on a polyaniline modified carbon electrode for the determination of l-phenylalanine has been proposed by utilizing β-cyclodextrin (β-CD) incorporated multi-walled carbon nanotube (MWNT) and imprinted sol-gel film. The electrochemical behavior of the sensor towards l-phenylalanine was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometric i-t curve. The surface morphologies of layer-by-layer assembly electrodes were displayed by scanning electron microscope (SEM). The response mechanism of the imprinted sensor for l-phenylalanine was based on the inclusion interaction of β-CD and molecular recognition capacity of the imprinted film for l-phenylalanine. A linear calibration plot was obtained covering the concentration range from 5.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.0 × 10−9 mol L−1. With excellent sensitivity, selectivity, stability, reproducibility and recovery, the electrochemical imprinted sensor was used to detect l-phenylalanine in blood plasma samples successfully.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号