首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
2.
Desorption electrospray ionization (DESI) is implemented on a portable mass spectrometer and used to demonstrate in situ detection of active ingredients in pharmaceutical preparations, alkaloids in plant tissues, explosives, chemical warfare agent simulants and agricultural chemicals from a variety of surfaces; air monitoring applications using DESI are also introduced.  相似文献   

3.
Ambient mass spectrometry is useful for analyzing compounds that would be affected by other chemical procedures. Poison frogs are known to sequester alkaloids from their diet, but the sequestration pathway is unknown. Here, we describe methods for whole‐body cryosectioning of frogs and use desorption electrospray ionization mass spectrometry imaging (DESI‐MSI) to map the orally administered alkaloid histrionicotoxin 235A in a whole‐body section of the poison frog Dendrobates tinctorius. Our results show that whole‐body cryosectioning coupled with histochemical staining and DESI‐MSI is an effective technique to visualize alkaloid distribution and help elucidate the mechanisms involved in alkaloid sequestration in poison frogs.  相似文献   

4.
Desorption electrospray ionization mass spectrometry (DESI-MS) and nuclear magnetic resonance (NMR) spectroscopy are used to provide data on urine examined without sample preparation to allow differentiation between diseased (lung cancer) and healthy mice. Principal component analysis (PCA) is used to shortlist compounds with potential for biomarker screening which are responsible for significant differences between control urine samples and samples from diseased animals. Similar PCA score plots have been achieved by DESI-MS and NMR, using a subset of common detected metabolites. The common compounds detected by DESI and NMR have the same changes in sign of their concentrations thereby indicating the usefulness of corroborative analytical methods. The effects of different solvents and surfaces on the DESI mass spectra are also evaluated and optimized. Over 80 different metabolites were successfully identified by DESI-MS and tandem mass spectrometry experiments, with no prior sample preparation.  相似文献   

5.
Desorption electrospray ionization (DESI) mass spectrometry has been implemented on a commercial ion‐trap mass spectrometer and used to optimize mass spectrometric conditions for DNA nucleobases: adenine, cytosine, thymine, and guanine. Experimental parameters including spray voltage, distance between mass spectrometer inlet and the sampled spot, and nebulizing gas inlet pressure were optimized. Cluster ions including some magic number clusters of nucleobases were observed for the first time using DESI mass spectrometry. The formation of the cluster species was found to vary with the nucleobases, acidification of the spray solvent, and the deposited sample amount. All the experimental results can be explained well using a liquid film model based on the two‐step droplet pick‐up mechanism. It is further suggested that solubility of the analytes in the spray solvent is an important factor to consider for their studies by using DESI. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Desorption electrospray ionization (DESI) mass spectrometry was evaluated for the characterization of glycerophospholipid standards, including glycerophosphocholine (GPCho), glycerophosphoglycerol (GPGro), glycerophosphoethanolamine (GPEtn), glycerophosphoserine (GPSer), glycerophosphoinositol (GPIns), cardiolipin (CL), and sphingolipid standards, including sulfatides (ST) and sphingomyelin (SM). Of specific interest were the effects of surface and solvent composition on signal stability and intensity, along with the ions observed in the full scan mode and the fragmentations seen upon collisional activation for each of the above classes. These experiments were performed without the addition of matrix compounds to the sample and were conducted in the free ambient environment at atmospheric pressure. The compounds GPSer, GPGro, GPIns, ST, and CL were best analyzed in the negative ion mode while PE was ionized efficiently in both positive and negative ion modes. SM and GPCho, which typically generate more abundant ions in the positive ion mode, could be analyzed in the negative ion mode by the addition of anionic reagents such as acetate to the spray solvent. Full scan DESI mass spectra and tandem (MS/MS) spectra for this representative set of physiological phospho/sphingolipids are presented. Similarities with other ionization methods in terms of fragmentation behavior were strong, although ambient ionization of untreated samples is only available with DESI. The effect of surface and solvent properties on signal intensity and stability were determined by depositing standard compounds on several different surfaces and analyzing with various proportions of methanol in the aqueous spray. Analysis was extended to complex mixtures of phospholipids and sphingolipids by examining the total lipid extract of porcine brain and by direct analysis of rat brain cryotome sections. These types of mixture analyses and molecular imaging studies are likely to represent major areas of application of DESI.  相似文献   

7.
Desorption electrospray ionization/post-photoionization (DESI/PI) is a newly developed ionization method by the combination of DESI and post-photoionization for the simultaneous imaging of polar and nonpolar compounds in biological tissues. Dopants are of great importance in DESI/PI for the enhancement of signal intensities through ion–molecule reactions. In this work, to evaluate the performance of dopants in DESI/PI, an efficient homogenate model was developed, and four kinds of dopants (toluene, chlorobenzene, bromobenzene, and anisole) were tested using homogenate of mouse brain tissue as target sample. The influences of the dopants on the signal enhancements of different compounds were explained reasonably by the ionization mechanism. Then, the dopants with their optimum volume contents were applied to the mass spectrometry imaging (MSI). For a comprehensive imaging of various compounds with different polarities, methanol/toluene/formic acid (7:3:0.1) was chosen as the best choice. Finally, the stronger quantitative ability of DESI/PI with toluene as dopant for a few compounds in mouse brain tissue was demonstrated.  相似文献   

8.
Desorption electrospray ionization mass spectrometry (DESI‐MS) and easy ambient sonic‐spray ionization mass spectrometry (EASI‐MS) are employed here in the forensic analysis of chemical compounds found in condoms and relative traces, and their analytical performances are compared. Statistical analysis of data obtained from mass spectra only was applied in order to obtain classification rules for distinguishing ten types of condoms. In particular, two supervised chemometric techniques [linear discriminant analysis (LDA) and soft independent modeling of class analogy (SIMCA)] were carried out on absolute and relative intensity values to test the performances of statistical models in terms of predictive capacity. The achieved classification of samples was excellent because of the high prediction percentages of the method used both for DESI and EASI mass spectrometry analyses, confirming these two as potential ambient ionization techniques for forensic analyses in case of sexual assault crimes. EASI‐MS showed 99% prediction ability for LDA using relative data and 100% prediction ability for SIMCA using both absolute and relative ones, while DESI showed 94% prediction ability for both LDA and SIMCA. The absence of any sample preparation technique gives advantages in terms of sample preservation and reduced contamination, allowing successive analyses to be performed on the same sample by other techniques. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
Desorption electrospray ionization (DESI) mass spectrometry is used to detect trace amounts of explosives present on a variety of ambient surfaces in 5-second analysis times without any sample preparation.  相似文献   

10.
薛震  邱波  林广欣  赖丛芳  罗海 《化学进展》2008,20(4):594-601
本文介绍了一种新近发展起来的质谱离子化方法——解吸电喷雾电离(desorption electrospray ionization, DESI)及其最新研究进展。该方法首次于2004年提出后,由于其具有样品无需前处理就可以在常压条件下从各种载物表面直接分析固相,或凝固相样品等优势而得到了迅速的发展。本文描述了DESI的基本原理、离子源的结构和相关优化的参数,并对该离子化方法中所用的载物表面进行了总结。在实际应用方面,本文综述了DESI技术在常压气相化学反应产物监测,合成高聚物表征,爆炸物和化学战毒剂检测,以及在药品,生物代谢产物和生物组织表面分析方面的应用成果,同时对DESI的基础应用研究方向进行了分析和展望。  相似文献   

11.
Sonic spray ionization is shown to create a supersonic cloud of charged droplets able to promote efficient desorption and ionization of drugs directly from the surfaces of commercial drug tablets at ambient conditions. Compared with desorption electrospray ionization (DESI), desorption sonic spray ionization (DeSSI) is advantageous since it uses neither heating nor high voltages at the spray capillary. DeSSI therefore provides a more friendly environment in which to perform ambient mass spectrometry (MS). DeSSI-MS is herein evaluated for the analysis of drug tablets, and found to be, in general, as sensitive as DESI-MS. The (high) voltage-free DeSSI method provides, however, cleaner mass spectra with less abundant solvent cluster ions and with enough abundant analyte signal for tandem mass spectrometry (MS/MS). These features may therefore facilitate the DeSSI-MS detection of low molar mass components or impurities, or both. The higher-velocity supersonic DeSSI spray also facilitates matrix penetration thus providing more homogenous sampling and longer lasting ion signals.  相似文献   

12.
A new method to analyze free amino acids using desorption electrospray ionization (DESI) has been implemented. The method is based on the neutral loss mode determination of underivatized amino acids using a tandem quadrupole mass spectrometer equipped with an unmodified atmospheric interface. Qualitative and quantitative optimization of DESI parameters, including ESI voltage, solvent flow rate, angle of collection and incidence, gas flow and temperatures, was performed for amino acids detection. The parameters for DESI analysis were evaluated using a mixture of valine, leucine, methionine, phenylalanine and tyrosine standards. A few microliters of this mixture were deposited on a slide, dried and analyzed at a flow rate of 2 microL/min. The optimal ionization response was obtained using laboratory glass slides and an equivalent solution of water/methanol doped with 2% of formic acid. The method specificity was evaluated by comparing product ion spectra and neutral loss analysis of amino acids obtained either by DESI or by electrospray ionization flow injection analysis (ESI-FIA). To evaluate the quantitative response on amino acids analyzed by DESI, calibration curves were performed on amino acid standard solutions spiked with a fixed amount of labelled amino acids. The method was also employed to analyze free amino acids from blood spots, after a rapid solvent extraction without other sample pretreatment, from positive and negative subjects. The method enables one to analyze biological samples and to discriminate healthy subjects from patients affected by inherited metabolic diseases. The intrinsic high-throughput analysis of DESI represents an opportunity, because of its potential application in clinical chemistry, for the expanded screening of some inborn errors of metabolism.  相似文献   

13.
Sulfated oligosaccharides derived from glycosaminoglycans (GAGs) are fragile compounds, highly polar and anionic. We report here on the rare but successful application of desorption electrospray ionization (DESI) — LTQ‐Orbitrap mass spectrometry (MS) to the high‐resolution analysis of anionic and sulfated oligosaccharides derived from the GAGs hyaluronic acid and heparin. For that purpose, key parameters affecting DESI performance, comprising the geometric parameters of the DESI source, the probed surface and the spraying conditions, applied spray voltage, flow rates and solvent composition were investigated. Under suitable conditions, the DESI technique allows the preservation of the structural integrity of such fragile compounds. DESI enabled the sensitive detection of anionic hyaluronic acid and heparin oligosaccharides with a limit of detection (LOD) down to 5 fmol (≈10 pg) for the hyaluronic acid decasaccharide. Detection of hyaluronic acid oligosaccharides in urine sample was also successfully achieved with LOD values inferior to the ng range. Multistage tandem mass spectrometry (MSn) through the combination of the DESI source with a hybrid linear ion trap‐orbitrap mass spectrometer allowed the discrimination of isomeric sulfated oligosaccharides and the sequence determination of a hyaluronic acid decasaccharide. These results open promising ways in glycomic and glycobiology fields where structure–activity relationships of bioactive carbohydrates are currently questioned. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A new method for tissue imaging using desorption electrospray ionization (DESI) mass spectrometry is described. The technique utilizes a DESI source with a heated nebulizing gas and high‐resolution accurate mass data acquired with an LTQ‐Orbitrap mass spectrometer. The two‐dimensional (2D) automated DESI ion source creates images using the ions that are collected under high‐resolution conditions. The use of high‐resolution mass detection significantly improves the image quality due to exclusion of interfering ions. The use of a heated nebulizing gas increases the signal intensity observed at lower gas pressure. The technique developed is highly compatible with soft tissue imaging due to the minimal surface destruction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer is described. Desorption electrospray technique is capable of the direct investigation of natural samples without any need for sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex owing to the lack of preseparation or cleanup, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. A three-dimensional linear stage was used to accommodate samples, while another 3D linear stage equipped with rotating stage was used as a spray mount. A modified electrosonic sprayer was used as a primary electrospray device. DESI-FTICR setup was characterized with regard to geometrical, electrical and flow conditions using deposited peptide samples in range of 1-100 pmol gross deposited amount on glass and polymer surfaces. Optimized conditions enabled the routine acquisition of DESI-MS spectra on the instrument at 130 000 resolution in the broadband mode and with comparable sensitivity to data reported in the literature. Since the main significance of DESI-FTICR MS is the combination of intact tissue analysis, the capabilities of the technique were demonstrated by analyzing murine liver samples. Presence of lysophospholipids in the liver tissue was tentatively associated with the lipid metabolism taking place in liver. DESI-FTICR is also a promising technique in the field of peptide analysis due to capability of top-down sequencing using electron capture dissociation. As a proof-of-principle experiment, a small synthetic polypeptide containing 36 amino acids was ionized using DESI and was sequenced in the FTICR by means of ECD (electron capture dissociation) fragmentation. Spectra gave almost full sequence information in agreement with the known amino acid sequence of the species.  相似文献   

16.
Desorption electrospray ionization mass spectrometry (DESI‐MS) requires little to no sample preparation and has been successfully applied to the study of biologically significant macromolecules such as proteins. However, DESI‐MS and other ambient methods that use spray desorption to process samples during ionization appear limited to smaller proteins with molecular masses of 25 kDa or less, and a decreasing instrumental response with increasing protein size has often been reported. It has been proposed that this limit results from the inability of some proteins to easily desorb from the surface during DESI sampling. The present study investigates the apparent mass dependence of the instrumental response observed during the DESI‐MS analysis of proteins using spray desorption collection and reflective electrospray ionization. Proteins, as large as 66 kDa, are shown to be quantitatively removed from surfaces by using spray desorption collection. However, incomplete dissolution and the formation of protein–protein and protein–contaminant clusters appear to be responsible for the mass‐dependent loss in sensitivity for protein analysis. Alternative ambient mass spectrometry approaches that address some of the problems encountered by spray desorption techniques for protein analysis are also discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
Desorption electrospray ionization mass spectrometry (DESI-MS) was used as a simple and rapid way to analyze drug tablets and powders without sample preparation. Experiments were performed with a home-made DESI source coupled to a triple-quadrupole linear-ion trap (QqQ(LIT)) mass spectrometer. Twenty-one commercial drugs as well as some illicit Ecstasy tablets and powders were analyzed. MS spectra almost exclusively showed the protonated or deprotonated ion of the drug after directing the pneumatically assisted electrospray onto the tablet's surface. With some tablets, inhomogeneity of the surface resulted in different spectra depending on the spot analyzed, thus showing that DESI could be used for imaging. Directly triggered MS/MS spectra were used for confirmatory analysis, with analysis times often below 10 s per tablet. For illicit Ecstasy tablets, DESI-MS, GC/MS and LC/MS analyses provided similar qualitative results for the main analytes. With MS/MS spectra library comparison or exact mass measurements, this technique could become very powerful for the rapid analysis of unknown tablets and shows the great potential of desorption techniques as an alternative to solution-based analysis.  相似文献   

18.
The N,N‐dimethylaniline (DMA) radical cation DMA.+, a long‐sought transient intermediate, was detected by mass spectrometry (MS) during the electrochemical oxidation of DMA. This was accomplished by coupling desorption electrospray ionization (DESI) MS with a waterwheel working electrode setup to sample the surface of the working electrode during electrochemical analysis. This study clearly shows that DESI‐based electrochemical MS is capable of capturing electrochemically generated intermediates with half‐lives on the order of microseconds, which is 4–5 orders of magnitude faster than previously reported electrochemical mass spectrometry techniques.  相似文献   

19.
江玮  喻钢 《分析测试学报》2012,31(4):430-435
自建了简易的电喷雾解吸电离源(DESI),优化了DESI源喷口的位置和角度,并将其用于常见多肽和蛋白质的分析。多肽和小质量蛋白质(<20 kDa)可以容易地从表面解吸电离,生成清晰的质谱。而牛血清白蛋白(66.4 kDa)不能产生清晰的多电荷分布的质谱,说明当前DESI源的设计可能存在一个电离的分子量上限。通过比较不同的实验条件并对比ESI-MS,发现溶剂分子的挥发过程对电荷分布以及峰宽均有显著影响,可能是由于ESI更软引起。载样表面的性质对DESI-MS的信号强度有较大影响。金表面的自组装单分子膜(SAM)相对于纯金表面有较好的绝缘性,并有助于产生较强信号,说明来自表面的电子转移(电中和)是电喷雾解吸电离过程中的一个重要因素。该文的研究有助于对DESI-MS的实验条件和载样表面的选择,同时增进了对电喷雾解吸电离机理的了解。  相似文献   

20.
Negative ion desorption electrospray ionization (DESI) was used for the analysis of an ex vivo tissue sample set comprising primary colorectal adenocarcinoma samples and colorectal adenocarcinoma liver metastasis samples. Frozen sections (12 μm thick) were analyzed by means of DESI imaging mass spectrometry (IMS) with spatial resolution of 100 μm using a computer-controlled DESI imaging stage mounted on a high resolution Orbitrap mass spectrometer. DESI-IMS data were found to predominantly feature complex lipids, including phosphatidyl-inositols, phophatidyl-ethanolamines, phosphatidyl-serines, phosphatidyl-ethanolamine plasmalogens, phosphatidic acids, phosphatidyl-glycerols, ceramides, sphingolipids, and sulfatides among others. Molecular constituents were identified based on their exact mass and MS/MS fragmentation spectra. An identified set of molecules was found to be in good agreement with previously reported DESI imaging data. Different histological tissue types were found to yield characteristic mass spectrometric data in each individual section. Histological features were identified by comparison to hematoxylin-eosin stained neighboring sections. Ions specific to certain histological tissue types (connective tissue, smooth muscle, healthy mucosa, healthy liver parenchyma, and adenocarcinoma) were identified by semi-automated screening of data. While each section featured a number of tissue-specific species, no potential global biomarker was found in the full sample set for any of the tissue types. As an alternative approach, data were analyzed by principal component analysis (PCA) and linear discriminant analysis (LDA) which resulted in efficient separation of data points based on their histological types. A pixel-by-pixel tissue identification method was developed, featuring the PCA/LDA analysis of authentic data set, and localization of unknowns in the resulting 60D, histologically assigned LDA space. Novel approach was found to yield results which are in 95% agreement with the results of classical histology. KRAS mutation status was determined for each sample by standard molecular biology methods and a similar PCA/LDA approach was developed to assess the feasibility of the determination of this important parameter using solely DESI imaging data. Results showed that the mutant and wild-type samples fully separated. DESI-MS and molecular biology results were in agreement in 90% of the cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号