首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
Zhao ZQ  Gao RM  Zhao LC 《Talanta》1992,39(6):643-647
In the presence of polyvinylalcohol (PVA-124) and polyethylene glycol monooctylphenyl ether (emulsifier OP), cadmium ions(II) can form a colour ion-association complex with both Bromopyrogallol Red (BPR) and Crystal Violet (CV). In the NH(3)NH(4)Cl medium, the ion-association complex has a composition of Cd:BPR:CV = 1:1:2, and its corresponding molecular formula is [CV](2)[Cd(BPR)]. The maximum absorption of the colour complex is located at 654 nm with an apparent molar absorptivity of 1.79 x 10(5) l.mole(-1).cm(-1). Beer's law is obeyed for cadmium over the range 0-10 mug/25 ml. A highly sensitive spectrophotometric method for trace cadmium in water and zinc was developed with good precision and accuracy. The mechanism of the reaction is also discussed.  相似文献   

2.
Zhou Y  Nagaoka T  Li F  Zhu G 《Talanta》1999,48(2):461-467
A novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO(4). Hydrogen peroxide can be directly determined by luminol-KIO(4)-H(2)O(2) CL system. The detection limit was 3.0x10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0x10(-7)-6.0x10(-4) mol l(-1). The relative standard deviation of H(2)O(2) was 1.1% for 2.0x10(-6) mol l(-1) (N=11). Glucose was indirectly determined through measuring the H(2)O(2) generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H(2)O(2), which, in turn, coupled with the luminol-KIO(4)-H(2)O(2) CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mug ml(-1). The relative standard deviation was 2.1% for 10 mug ml(-1) (N=11). Detection limit of glucose was 0.08 mug ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO(4)-H(2)O(2) CL system. The calibration curve was linear over the range of 1.0x10(-7)-1.0x10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0x10(-7) mol l(-1) (N=11). Detection limit of ascorbic acid was 6.0x10(-8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection.  相似文献   

3.
Sedaira H 《Talanta》2000,51(1):39-48
A new direct spectrophotometric determination of manganese with 5,8-dihydroxy-1,4-naphthoquinone (naphthazarin,NAZA) is reported. Absorption maximum, molar absorptivity and Sandell's sensitivity of 1:2 (M:L) complex are 695 nm, 1.88x10(4) l mol(-1) cm(-1) and 2.92 ng cm(-2), respectively. A linear calibration graph is obtained up to a concentration of 7.2 mug ml(-1) of manganese. The optimum range for determination (Ringbom) is between 0.20 and 6.8 mug ml(-1). A rapid method for simultaneous determination of manganese and zinc in their mixture using derivative spectra is described. The range 0.28-5.6 mug ml(-1) manganese could be determined in the presence of 0.33-6.8 mug ml(-1) zinc and vice versa. The developed method was applied to the simultaneous spectrophotometric determination of manganese and zinc in some synthetic mixtures and was found to give satisfactory results.  相似文献   

4.
Kamburova M 《Talanta》1992,39(8):997-1000
Optimum conditions for complexation in the systems triphenyl-tetrazolium chloride-iodate-iodide-dichlorethane and triphenyltetrazolium chloride-periodate-iodide-dichlorethane were found. The molar absorptivity of the complex was 7.48 x 10(4) 1. mole(-1). cm(-1) for the iodate, and 9.09 x 10(4)1. mole(-1) cm(-1) for the periodate. Beer's law is adhered to in the range of 0.04-0.7 mug/ml for iodate and 0.02-0.35 mug/ml for periodate. The influence of foreign ions was studied. Cr(VI), Hg(II) and S(2)O(2-)(3) interfere. The proposed method has been applied to analysis of iodate and periodate in fresh water.  相似文献   

5.
Zhou Y  Zhu G 《Talanta》1997,44(11):2041-2049
Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL). The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6)mug ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6)mug ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4)mug ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved manganese in underground water during water treatment.  相似文献   

6.
Zhao J  Xu Q 《Talanta》1991,38(8):909-912
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of platinum. 5-(4-Nitrophenylazo)-8-(p-toluenesulphonamido)quinoline (NPTSQ) reacts with platinum(II) almost instantaneously in alkaline solution to form a violet-red 1:2 complex with an absorption maximum at 640 nm. Beer's law is obeyed over the concentration range 0-1 mug/ml platinum. The molar absorptivity is 1.37 x 10(5) 1.mole(-1).cm(-1). The method has been used for the determination of microamounts of platinum in catalysts and anode slime.  相似文献   

7.
A simple and sensitive spectrophotometric method for determination of copper(II) is based on the formation of a blue coloured complex of Cu(II) with 9-phenyl-2,3,7-trihydroxy-6-fluorone (PF) in the presence of cetylpyridinium chloride (CP) and Triton X-100, has been developed. Optimum concentrations of PF, CP, Triton X-100 and pH ensuring maximum absorbance were defined. The complex Cu(II)-PF-CP-Triton X-100 shows maximum absorbance at 595 nm with a molar absorptivity value of 9.67x10(4) l mol(-1) cm(-1). The detection limit of the method is 0.028 mug ml(-1). Beer's law is obeyed for copper concentrations in the range 0.04-0.4 mug ml(-1). The studies of the effect of foreign ions on determination of copper, show that the selectivity of the method is poor. The cations of alkali metals and anions Br(-), Cl(-), I(-), F(-), NO(2)(-), NO(3)(-), CH(3)COO(-), SO(4)(2-), S(2)O(3)(2-), PO(4)(3-), citrates (examined in 1000-fold molar excess over copper) do not affect the determination. All cations forming complexes with PF have an interfering effect. The statistical evaluation of the method was carried out for six determinations using 10 mug of Cu and the following results were obtained: the standard deviation, SD=0.042, the confidence interval mu(95)=10.1+/-0.1 mug Cu. The method has been applied for determination of copper in blood serum.  相似文献   

8.
Takaoka T  Taya T  Otomo M 《Talanta》1992,39(1):77-80
The optimum conditions for the extractive-spectrophotometric determination of trace iron(II) with di-2-pyridylmethanone 2-(5-nitro)pyridylhydrazone have been established. Iron(II) reacts with this reagent at pH 2.0-7.5 to form an uncharged 1:2 (metal-to-ligand) complex, which can be extracted with toluene. Beer's law is obeyed over the range up to 0.84 mug/ml of iron(II) at 505 nm. The molar absorptivity of the extracted species is 5.83 x 10(4) 1.mole(-1).cm(-1). The proposed method is extremely sensitive and reproducible, and has been satisfactorily applied to the determination of total iron in freshwater samples by adding ascorbic acid to reduce iron(III).  相似文献   

9.
Mori I  Fujimoto T  Fujita Y  Matsuo T 《Talanta》1995,42(1):77-81
Spectrophotometric determinations of benzoylperoxide (BPO) and copper(II) were, respectively, investigated by using the colour reaction for N-ethyl-2-naphthylamine (NENA), BPO and copper(II) as a metal ion in various concentrations of acetonitrile-water mixed solution as acidic media. The calibration graphs were linear in the range of 0-200 mug BPO with apparent molecular coefficient (epsilon) of 8.5 x 10(3)M(-1) cm(-1) at 530 nm, and 0-2.4 mug per 10 ml copper(II) with epsilon = 1.72 x 10(5)M(-1) cm(-1) at 533 nm, respectively. Additionally, the FIA method for copper(II) was proposed with NENA-BPO. The calibration graph for FIA was linear in the range of 0-7.9 ng copper(II) per 5 mul at 533 nm. These proposed methods were selective and simple in comparison with previous methods such as cuproin kinetic reactions, especially the spectrophotometry for copper(II) with NENA-BPO was very specific, and the effect of foreign ions was negligible.  相似文献   

10.
Pal BK  Chowdhury RP  Mitra BK 《Talanta》1981,28(1):62-64
The use of hexamethylphosphoramide (HMPA) in the osmium-thiocyanate system makes the method more sensitive and selective. The blue colour formed by osmium(VIII) with thiocyanate in 1.5M hydrochloric acid is intensified in the presence of HMPA and the complex becomes readily extractable into chloroform. The colour system has its absorption maximum at 595 nm and obeys Beer's law over the range 0.5-16 mug of Os per ml. The optimum range is 2-10 mug/ml. The molar absorptivity is 2.09 x 10(4)l.mole(-1).cm(-1). The method is simple, sensitive and free from interference from many metal ions, including ruthenium and other platinum metals.  相似文献   

11.
The water-soluble polymers poly(ethylenimine), quaternized poly(ethylenimine), and poly-4-vinyl-(N-benzyltrimethyl) ammonium chloride were found to be able to change the kinetics of the reaction of cobalt with nitroso-R-salt and the optical density of the cobalt complex formed. The optimum pH range for the complex formation was a wide range from 1 to 10 and at pH 2 the reaction developed instantly. The calibration graph was linear in the range 0.005-2 mug ml(-1). The effective molar absorptivity coefficient of the complex was equal to (2.8+/-0.08)10(3). A spectrophotometric determination method for cobalt with nitroso-R-salt in the presence of water-soluble polymers (before and after membrane preconcentration) and a colorimetric flow injection method were developed. For the flow injection-based spectrophotometric determination, the calibration graph was linear in the concentration range of 0-4.0 mug ml(-1) cobalt with a regression coefficient of 0.9992. The relative standard deviation (R.S.D.) for the determination of 1.0 mug ml(-1) cobalt was 0.9% (ten replicate injections), and at all concentration measured, the R.S.D. of the data was below 5.0%. The proposed FI procedure was applied to river water samples after membrane preconcentration of cobalt. The limit of detection was 4 ng ml(-1).  相似文献   

12.
Yang W  Teng XL  Chen M  Gao JZ  Yuan L  Kang JW  Ou QY  Liu SX 《Talanta》1998,46(4):527-532
In the present paper, N,N'-dinaphthyl-N,N'-diphenyl-3,6-dioxaoctanediamide acts as a specific reagent for enhancing the fluorescence intensity of Eu(III) complex with thenoyl trifluoroacetone (TTA), the spectrofluorimetric determination of trace amounts of Eu(III) based on the above system was carried out and its luminescence mechanism was studied. The excitation and emission wavelengths are 343.6 and 613.3 nm, respectively. The fluorescence intensities vary linearly with the concentration of europium(III) in the range 3.647x10(-3)-3.039 mug ml(-1) for the original fluorescence with a detection limit down to 2.279x10(-4) mug ml(-1) and the standard deviation is 0.063 mug ml(-1) for 10 times measurements, and in the range 7.598x10(-4)-0.0243 mug ml(-1) (SD=0.035 for 15 times measurements), 0.06078-0.6100 mug ml(-1) (SD=0.52 for 10 times measurements) for the first derivative fluorescence signal with a detection limit down to 8.566x10(-5) mug ml(-1). The interferences of other rare earths and some of inorganic ions are described. This method is a direct, rapid, selective and sensitive analytical method for the determination of trivalent europium in rare earth ore samples and high purity of rare earth oxides.  相似文献   

13.
Satake M  Nagahiro T  Puri BK 《Talanta》1992,39(10):1349-1354
A solid ion-pair compound produced from sodium 1,2-dihydroxybenzene-3,5-disulphonic acid (Tiron) and tetradecyldimethylbenzylammonium chloride(TDBA) supported on naphthalene in a simple glass-tipped funnel tube provides a simple adsorbent system for preconcentrating titanium from some alloys. Titanium reacts with Tiron to form a water-soluble coloured chelate anion which in turn forms a water-insoluble stable titanium/Tiron/TDBA complex with the ion-pair on the surface of naphthalene packed in a column. Titanium is quantitatively retained on the naphthalene in the presence of L-ascorbic acid and oxalic acid in the pH range 3.0-4.5 and at a flow-rate of 1 mil/min. The metal complex and naphthalene were dissolved from the column with 5 ml of dimethylformamide(DMF), and the absorbance of the solution was measured at 398 nm. A calibration graph was linear over the range 1-18 mug of titanium in 5 ml of the final DMF solution. The complex has a molar absorptivity of 1.39 x 10(4) l.mole(-1).cm(-1) and a sensitivity of 3.44 x 10(-3) mug/cm(2) for 0.001 absorbance. Eight replicate determinations for a sample containing 12 mug of titanium gave a mean absorbance of 0.697 with a relative standard deviation of 0.82%. The interference of various ions was studied and optimum conditions were developed for the determination of titanium in various aluminium and zinc alloys.  相似文献   

14.
Zhou N  Gu YX  Lu ZR  Chen WY 《Talanta》1989,36(7):739-742
A new spectrophotometric method for the determination of zinc is proposed. The chromogenic agent Hydrazidazol forms a 1:1 chelate with zinc in the presence of Triton X-100 in a medium containing 20-40% ethanol. The molar absorptivity and conditional formation constant have been found to be 2.7 x 1O(4) l.mole(-1).cm(-1) (at 640 nm) and 10(5.32) respectively. Beer's law is obeyed for zinc over the range of 0.2-0.8 mug/ml with a standard deviation of 0.024 mug/ml. The method can be applied to the determination of zinc in cadmium metal and its oxide after preconcentration by selective extraction of zinc thiocyanate into ethyl acetate in the presence of EDTA and thiosulphate as masking agents.  相似文献   

15.
Sahu R  Sondhi SM  Gupta B 《Talanta》1995,42(3):401-405
A method for the extraction-spectrophotometric determination of palladium with 3,4,4a,5-tetrahydro-3,3,4a-trimethyl-7-(substituted)-pyrimido(1,6-a)benzimidazole-1-thiol (PBT) is described. PBT-Pd(II) complex is extracted from an acidic aqueous solution (0.01-0.5M HClO(4)) into a chloroform layer. The absorbance is measured at 438 nm and the molar absorptivity found to be 1.033 x 10(4)M(-1) cm(-1). The complex system conforms to Beer's law over the range 1.9-28.5 mug/ml palladium(II). The effects of pH (2-6), HClO(4) concentration, PBT concentration and shaking time were studied. The ratio of metal ion to ligand molecules in the coloured complex was found to be 1:4. The tolerance limit for many metals have been determined. Finally, the method has been applied successfully to the determination of palladium in synthetic mixtures and in the standard palladium carbon powder (palladium catalyst).  相似文献   

16.
Idriss KA  Sedaira H  Ahmed HM 《Talanta》2001,54(2):369-375
The complexation equilibria of magnesium(II) with purpurin (PURP) are studied spectrophotometrically as a function of pH in 50% (v/v) ethanol-water medium at 20 degrees C. The uncharged complex formed at pH 9.5 allows precise and accurate determination of magnesium over the concentration range 0.8-4.3 mug ml(-1). The molar absorptivity of the Mg-PURP complex at 540 nm and detection limit for Mg are 9.2x10(3) l mol(-1) cm(-1) and 75 ng ml(-1), respectively. The proposed method is rapid and possesses reasonable selectivity. Under the optimum conditions, the use of first-derivative spectrophotometry has the advantage of high sensitivity than normal spectrophotometry and allows the determination of 0.2 mug ml(-1) of magnesium. The validity of the method is examined by analysing several SRM Portland cement samples and a variety of cement materials of variable magnesia content.  相似文献   

17.
Aly FA  Al-Tamimi SA  Alwarthan AA 《Talanta》2001,53(4):885-893
A new chemiluminescence (CL) method using flow injection has been described for the rapid and sensitive determination of three fluoroquinolone derivatives, namely ofloxacin, norfloxacin and ciprofloxacin hydrochloride. The method is based on the CL reaction of the studied fluoroquinolones with tris(2,2'-bipyridyl)ruthenium(II) [Ru(bipy)(3)(2+)] and Ce(IV) in sulfuric acid medium. Under the optimum conditions, the CL intensity is proportional to the concentration of the drugs in solution over the range 0.05-7.0 mug ml(-1) for norfloxacin, 0.05-6.0 mug ml(-1) for ciprofloxacin hydrochloride and 0.003-0.7 mug ml(-1) for ofloxacin. The limits of detection (s/n=3) were 3.1x10(-8) M norfloxacin, 2.6x10(-8) M ciprofloxacin hydrochloride and 5.5x10(-9) M ofloxacin. The method was applied successfully to the determination of these compounds in dosage forms and biological fluids.  相似文献   

18.
Satake M  Matsumura Y  Fujinaga T 《Talanta》1978,25(11-12):718-720
A new method is proposed for collecting traces of nickel from aqueous solution by precipitation as the alpha-furildioxime complex and adsorption of this onto microcrystalline naphthalene. The precipitate is collected, dried, and dissolved in chloroform, and the nickel is determined spectrophotometrically at 438 nm. The linear calibration range is 2-35 mug/10 ml. The molar absorptivity is 1.6 x 10(4) l. mole(-1). cm(-1). The main advantage is that the nickel is collected quantitatively after only a few seconds'shaking. The effect of varying pH, amount of reagent, naphthalene or buffer, shaking and standing time, and interferences have been investigated.  相似文献   

19.
Ohly P  Wang Z  Abel J  Gleichmann H 《Talanta》1998,47(2):355-359
A new azoamino reagent amido black diazoaminoazobenzene (ABDAB) has been synthesized, and found to be a good chromogenic reagent for cadmium. In pH 10.4 Na(2)B(4)O(7)NaOH buffer solution cadmium reacts with ABDAB to form an orange-red chelate (1:2), exhibiting an absorption maximum at 520 nm. The apparent molar absorptivity is 1.62x10(5) l mol(-1) cm(-1). Beer's law is obeyed in the range 0-8 mug/25 ml Cd. The method is simple and rapid, with high sensitivity and good selectivity and is applied to the determination of trace amounts of cadmium in waste water and metal materials with satisfactory results.  相似文献   

20.
Rao DM  Reddy KH  Reddy DV 《Talanta》1991,38(9):1047-1050
A rapid, sensitive and selective method has been developed for the determination of palladium with 5,6-dimethyl-1,3-indanedione-2-oxime in acetate buffer (pH 5.5). Beer's law is obeyed over the range 0.15-4.17 mug/ml palladium(II). The molar absorptivity at 370 nm is 2.98 x 10(4) 1.mole(-1).cm(-1). The method has been applied for the determination of palladium in synthetic mixtures corresponding to PtIr and Oakay alloys. An interesting feature of the system is the abnormal shape of the Job and molar-ratio plots obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号