首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, a modified nanoporous silica aerogel was used as a new sorbent for headspace needle trap extraction of chlorobenzenes from aqueous samples. The needle trap extraction is derived from solid-phase microextraction and the sorbent is inside the needle. The thermal stability and functional groups of the sorbent were studied by TG/DTA and FT-IR, respectively. The modified silica aerogels, characterized by field emission scanning electron microscopy, showed a three-dimensional network containing a homogeneous pore structure with pore sizes of a few tens of nm and a sponge-like microstructure. The developed method was applied to the trace level extraction of some chlorobenzene compounds from aqueous samples. The influential parameters on the extraction efficiency, including the extraction temperature, ionic strength and extraction time were investigated and optimized. Under optimized conditions, the detection and quantification limits were in the range of 0.4–0.8 and 1–3 ng L?1, respectively. The relative standard deviation values for water spiked with chlorobenzenes at 100 ng L?1 under optimum conditions were 3–7%. The dynamic linear range of the method in the range of 3–3000 ng L?1 was investigated. Finally, the current method for the analysis of real water samples containing spiked chlorobenzenes was applied and the relative recovery values were found to be in the range of 96–101%.  相似文献   

2.
We report on a simple, rapid, and efficient method for the extraction of volatile organic compounds (VOCs; including methanol, tetrahydrofuran, 2-hexanone and benzene) from air and solid samples. The system is based on the use of a laboratory-made syringe as the extractor. The needle of the syringe is placed in a chamber cooled by liquid nitrogen. The tip of the needle is placed in the headspace of a vial containing the sample. The headspace components then are circulated with a pump to pass the needle, and this results in freeze-trapping of the VOCs on the inner surface of the needle. The circulation of the headspace components is continued for 15 min, and the syringe is then removed and placed in a GC injector. The effects of volume of the sample vial, headspace flow rate, temperature and time of extraction and desorption were optimized. The overall time for sampling and analysis is <30 min. The method displays an extraction efficiency of >80%) and a good sample transfer efficiency into the GC column due to the absence of a sorbent inside the needle. No carry-over was observed after 30?s desorption at 260?°C. An external standard method was used for quantitative analysis. The relative standard deviation values are below 10% and the limits of detection range from 1.3 to 4.6?ng?g?1.
Fiugre
The scheme of sorbentless cryogenic needle trap device  相似文献   

3.
A rapid and simple large volume headspace (HS) sampling technique termed headspace solid-phase microcolumn extraction (HS-SPMCE) is described. HS gas above a liquid or solid sample is aspirated by attaching a gas-tight syringe onto a glass thermal desorption tube filled with Tenax sorbent. The trapped analytes are recovered by thermal desorption for gas chromatography–mass spectrometry (GC–MS) analysis. Benzene, toluene, ethylbenzene and the xylene isomers (BTEX) are used as model compounds to demonstrate the application of the extraction procedure for water samples. The results of the tests of the effect of agitation time and aspiration rate on recovery of the analytes show a good robustness of the method. BTEX are determined in the linear range from 0.5 to 50.0 μg L?1 with limits of detection (3 σ) ranging within 0.09–0.14 μg L?1 (MS was in scan mode). The method provides a good repeatability (RSD < 9%) and only a negligible carryover effect was observed ( ≤0.05%) when analysing BTEX at concentration 50.0 μg L?1.  相似文献   

4.
A high-temperature-resistant solid-phase microextraction (SPME) fiber was prepared based on polyetherimide (PEI) by the electrospinning method. The PEI polymeric solution was converted to nanofibers using high voltages and directly coated on a stainless steel SPME needle. The scanning electron microscopy images of PEI coating showed fibers with diameter range of 500–650 nm with a homogeneous and smooth surface morphology. The SPME nanofibers coating was optimized for PEI percentage, electrospinning voltage, and time. The extraction efficiency of the coating was investigated for headspace SPME of some environmentally important polycyclic aromatic hydrocarbons from aqueous samples followed by gas chromatography–mass spectrometry measurement. In addition, the important extraction parameters including extraction temperature, extraction time, ionic strength, as well as desorption temperature and time were investigated and optimized. The detection limits of the method under optimized conditions ranged from 1 to 5 ng L?1 using time-scheduled selected ion monitoring mode. The relative standard deviations of the method were between 1.1 and 7.1 %, at a concentration level of 500 ng L?1. The calibration curves of polycyclic aromatic hydrocarbons showed linearity in the range of 5–1000 ng L?1. The developed method was successfully applied to real water samples and the relative recovery percentages obtained from the spiked water samples were from 84 to 98 % for all the selected analytes except for acenaphthene which was from 75 to 106 %.  相似文献   

5.
We have evaluated the behavior of single-walled carbon nanohorns as a sorbent for headspace and direct immersion (micro)solid phase extraction using volatile organic compounds (VOCs) as model analytes. The conical carbon nanohorns were first oxidized in order to increase their solubility in water and organic solvents. A microporous hollow polypropylene fiber served as a mechanical support that provides a high surface area for nanoparticle retention. The extraction unit was directly placed in the liquid sample or the headspace of an aqueous standard or a water sample to extract and preconcentrate the VOCs. The variables affecting extraction have been optimized. The VOCs were then identified and quantified by GC/MS. We conclude that direct immersion of the fiber is the most adequate method for the extraction of VOCs from both liquid samples and headspace. Detection limits range from 3.5 to 4.3 ng L?1 (excepted for toluene with 25 ng L?1), and the precision (expressed as relative standard deviation) is between 3.9 and 9.6 %. The method was applied to the determination of toluene, ethylbenzene, various xylene isomers and styrene in bottled, river and tap waters, and the respective average recoveries of spiked samples are 95.6, 98.2 and 86.0 %.
Figure
Schematic representation of the direct immersion / headspace (micro)solid phase extraction using oxidized single walled carbon nanohorns supported on a microporous hollow fiber for the extraction of volatile organic compound from water samples.  相似文献   

6.
A new micro-solid phase extraction method was developed by combining solid-phase extraction and stir bar sorptive extraction to benefit from the advantages of both techniques. A polypyrrole coating was electrochemically synthesized on the surface of an already used graphite furnace, employed in electro-thermal atomic absorption spectroscopy. The cylindrical geometry of the graphite tube provided a rather huge surface area, suitable for sorptive extraction. The novel sorbent coating was examined as an extracting medium to isolate malathion. Effects of different parameters such as extraction time, salt concentration, sample volume, desorption solvent and time were investigated and optimized. Under the optimized conditions, the limit of detection and limit of quantification of the developed method were 5 and 20?ng?L?1, respectively. The calibration curve showed linearity in the range of 0.1?C100???g?L?1 (R 2?=?0.9968). The precision was evaluated at 0.1 and 1???g?L?1 concentration levels and relative standard deviations (n?=?3) were found to be 10 and 7%, respectively. The developed method was successfully applied to the extraction of malathion from real river water and tap water samples, and relative recoveries at the spiked level of 0.1???g?L?1 were 94 and 97%, respectively.  相似文献   

7.
A novel and efficient sulfadiazine imprinted polymer was synthesized via co-precipitation method and successfully grafted on magnetic multi-walled carbon nanotubes. The synthesized magnetic imprinted polymer was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray powder diffraction analysis, thermal analysis and applied as a sorbent for selective magnetic solid-phase extraction of sulfadiazine. The retained sulfadiazine was eluted by 150.0 µL methanol/acetic acid (6:4) solution and quantified by fiber optic linear array spectrophotometry via formation of a detectable azo dye. All parameters affecting the extraction of sulfadiazine were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 2.0–50.0 µg L?1 with a detection limit of 0.56 µg L?1 and enrichment factor of 300.0. The relative standard deviation at 30.0 µg L?1 of sulfadiazine (N = 6) was 2.8 and 4.6% for intra-day and inter-day, respectively. The method was successfully applied to determine sulfadiazine in human urine, honey, milk and environmental water samples.  相似文献   

8.
In this research, nickel ferrite (NiFe2O4) magnetic nanoparticles were synthesised by a simple method and applied as sorbent for magnetic solid-phase extraction of trace amounts of Au(III) from water samples. Detection in this technique was performed by flame atomic absorption spectrometry. The effects of sample pH, amount of sorbent, extraction time, desorption solvent and its volume on the extraction process were optimised. The effects of interfering ions on the recovery of the analyte were also evaluated in model solutions. The best results were obtained at pH 6.5 with 5 mL of eluent solution (0.1 mol L?1 sodium thiosulphate) and an extraction time of 30 min. Under optimal conditions, the sorption capacity was 34.6 mg g?1. Also, enhancement factor (for 100 mL of sample solution) was found to be 19.3. The calibration graph was linear in the range of 4.4–800.0 µg L?1 gold concentration and the limit of detection was 1.32 µg L?1. The relative standard deviation of the method (for n = 8) was 1.57%. The method was successfully applied to the extraction of Au(III) from water samples.  相似文献   

9.
Graphene, a novel class of carbon nanostructures, has great promise for use as sorbent materials because of its ultrahigh specific surface area. A new method using reduced graphene oxide (RGO) as sorbent was developed for the preconcentration of trace amounts of zinc (Zn) to its determination by flame atomic absorption spectrometry. Zinc could be adsorbed quantitatively on RGO in the pH range of 1–9, and then eluted completely with 0.5 mL of 0.1 mol L?1 HCl. Some effective parameters on the extraction were selected and optimized. Under optimum conditions, the calibration graph was linear in the concentration range of 0.2–15 μg L?1 with a detection limit of 0.14 μg L?1 with an enrichment factor of 100.12. The relative standard deviation for ten replicate measurements of 10 μg L?1 of Zn was 0.58 %, respectively. The proposed method was successfully applied in the analysis of rock and vegetable samples. Good spiked recoveries over the range of 99.9–100 % were obtained. This work not only proposes a useful method for sample preconcentration, but also reveals the great potential of graphene as an excellent sorbent material in analytical processes.  相似文献   

10.
In this paper, a procedure for the determination of 11 aromatic hydrocarbon-type sensitisers and their related compounds from water samples, used in the manufacture of thermal paper, is presented. The compounds were extracted using a solid-phase extraction (SPE) cartridge with an octadecyl (C18) or a phenyl-bonded silica (PH) sorbent and then determined by gas chromatography–mass spectrometry (GC–MS). Factors affecting the performance of the extraction steps were thoroughly evaluated, and their effects on the yield of the sample preparation were discussed. Under optimised experimental conditions, SPE cartridges were conditioned with 10?mL hexane followed subsequently by 10?mL methanol, loaded with water sample at 2?mL?min?1, and eluted with 10?mL hexane at 1.5?mL?min?1. The limits of detection and quantification, calculated for signal-to-noise ratios of 3 and 10, were in the range of 1–5?µg?L–1 and 2.5–10?µg?L–1, respectively. Recovery yields of the present method using river water were in the range of 88%–112% with a C18 sorbent and 86%–116% with a PH sorbent. The repeatability, expressed as a relative standard deviation, was in the range of 2.8%–11% with a C18 sorbent and 0.7%–9.7% with a PH sorbent (n?=?4). Analysis of paper mill effluents revealed the presence of aromatic hydrocarbon-type sensitisers with maximum concentrations of up to 5.2?µg?L?1.  相似文献   

11.
In this study, directly suspended liquid-phase microextraction was investigated for the extraction and determination of five chlorophenoxy acid herbicides in water samples. The optimized parameters for extraction of chlorophenoxy acid herbicides were 1 M HCl concentration in sample solution, solution temperature 20 °C, 45-min extraction time, 1,000 rpm stirring rate, 25 ??L extracting solvent volume and without NaCl addition. Under the optimum conditions, the enrichment factor ranged from 192 to 390. Calibration curves yielded good linearity (R 2 > 0.999) and the linear range was 5.0?C500.0 ??g L?1, limit of detection was 0.3?C0.4 ??g L?1 and limit of quantification was 1?C2 ??g L?1 for analytes and the relative standard deviations were in the range of 3?C10% (n = 3). Finally, the proposed method was successfully applied to the quantification of five chlorophenoxy acid herbicides in water samples and recovery was in the range of 74?C110%.  相似文献   

12.
Ultrasound-assisted dispersive liquid?Cliquid microextraction (USA-DLLME) with low solvent consumption was demonstrated for gas chromatography-mass spectrometry (GC?CMS) determination of 16 typical polycyclic aromatic hydrocarbons (PAHs) in seawater samples. Factors affecting the extraction process, such as extraction and dispersive solvent, phase ratio, temperature, extraction and centrifugation time, were investigated thoroughly and optimized. The linear range was 20?C2,000 ng L?1 except for acenaphthylene (Acy) at 10?C2,000 ng L?1 and phenanthrene (Phe), fluoranthene (Flu) and pyrene (Py) all at 5?C2,000 ng L?1. Enrichment factors (EFs) ranging from 722 to 8,133 were obtained, achieving limits of detection at 1.0?C10.0 ng L?1. The method attained good precision (relative standard deviation, RSD) from 3.4 to 14.2% for spiked 50 ng L?1 individual PAHs standards. Method recoveries were in the range 87?C124% and 70?C127% for spiked samples from simulated seawater and beach seawater, respectively. The proposed USA-DLLME helped to obtain about 1.1?C10 times higher EFs in a minimum amount of solvent and in less time than traditional DLLME.  相似文献   

13.
In this study, a new sample vial has been designed for the extraction and determination of methyl tert-butyl ether (MTBE) in water samples by headspace solid-phase microextraction method. The special feature of this new vial is cooling the HS above the aqueous sample by cold water stream for maximum analyte absorption on SPME fiber coating. The analysis was by a gas chromatograph equipped with flame ionization detector and a capillary column (CP-sil 13 CB). Some significant variables affecting the extraction procedure were optimized. By use of divinylbenzene/carboxen/polydimethylsiloxane fiber, a sample volume of 10 mL, stirring rate of 1,000 rpm, salt concentration of 24%, extraction time of 15 min and extraction temperature of 83 °C, detection limit of 0.022 μg L?1 and a good linearity (R 2 = 0.998) in a calibration range of 0.1–400 μg L?1 were achieved. The relative standard deviation for triplicate runs ranged between 6 and 8%. The method could be applied to the analysis of trace levels of MTBE in various water samples.  相似文献   

14.
An effective and rapid method was developed for simultaneous determination of seven sulfonylurea herbicides in environmental water using multiwalled carbon nanotubes as solid-phase extraction sorbent coupled with liquid chromatography–tandem mass spectrometry. Important parameters influencing the extraction efficiency such as pH of the sample solution, flow rate of sample loading, the eluent and its volume were optimized. Under optimum conditions, good linearity was obtained for all herbicides (r 2 > 0.99) over the range of 0.05–5,000 ng L?1, and precisions (RSD) for nine replicate measurements of a standard mixture of 200 ng L?1 were 1.9–7.4%. The limits of detection and quantification were 0.01–0.20 and 0.05–1.00 ng L?1, respectively. The proposed method was successfully applied to the analysis of tap water, spring water, ground water and well water, and mean recoveries for seven analytes at three spiked concentration levels were from 81.5 to 110.5% with RSDs between 0.3 and 7.0%. The results showed that the established method has wide application to analyze sulfonylurea herbicides at trace level in water.  相似文献   

15.
An amine-functionalized metal–organic framework based on aluminum (NH2-MIL-53(Al)) was synthesized and employed as a sorbent for the extraction of phenolic pollutants. A new designed sorbent-injection vortex-assisted dispersive microsolid-phase extraction was proposed in which the sorbent suspension was simply injected into the sample solution. Herein the experimental parameters that affected the extraction efficiency for the target analytes were optimized, including volume of sorbent suspension, vortex agitation time, eluent type and its volume, and sample volume. Good linearity was obtained in the concentration range of 0.1–10.0 mg L?1 with the correlation coefficients in the range of 0.9970–0.9981. The LODs and LOQs were in the ranges of 0.030–0.055 and 0.090–0.150 mg L?1, respectively. The results of the intra- and inter-day experiments showed good precision of peak area with the relative standard deviation (RSD) values of better than 5.82 and 7.85%, respectively. The developed method has been successfully applied to determine phenolic residues in water samples. The satisfactory recoveries were obtained in the range of 83.0–122.4% with the RSDs of less than 12.9%. In addition, molecular docking was performed to predict the adsorption ability of NH2-MIL-53(Al) sorbent toward the target analytes. The computational results were in good agreement with data obtained experimentally.  相似文献   

16.
In this study, combined technique of solid-phase extraction based on multi-walled carbon nanotubes with bio-coacervation extraction (SPE-MWCNT-BCAE) has been developed as a new sample preparation method for the determination of atrazine from water samples. The proposed method involves two steps: analyte enrichment on the solid sorbent and subsequently elution of the analyte by an appropriate solvent. Multi-walled carbon nanotubes (MWCNTs) were used as the sorbent. They have high specific surface area, nano-scale structure and high diffusion rate. The second step is based on the use of bioaggregates for analyte re-enrichment, which consists of biosurfactants and ionic liquid. This method follows the principles of green chemistry. Parameters affecting the extraction efficiency were optimized. Under optimum conditions, the enrichment factor was 176. The linear dynamic range (LDR) and limit of detection (LOD) were 2–100 µg L?1 and 0.66 µg L?1, respectively. The relative standard deviation (RSD) for six replicate measurements was 3.8%. The method was applied to the determination of ultratrace levels of atrazine in environmental water samples with satisfactory results.  相似文献   

17.
A single-drop microextraction (SDME) procedure with a modified microsyringe was developed for the analysis of six organophosphorus pesticides (OPPs) in water. Microsyringe was modified by attaching a 2-mm cone onto the needle tip end. The conditions affecting SDME performance including microextraction solvent, stirring speed, extraction time, ionic strength and sample pH were optimized. Under the optimized conditions, the linear ranges of the SDME with ethion as internal standard were 0.05–50 μg L?1 (except for dimethoate 5–5,000 μg L?1) and limits of detection (LOD) were 0.012–0.020 μg L?1 (except for dimethoate 0.45 μg L?1). Recoveries of six pesticides were in the range of 70.6–107.5 % with relative standard deviation lower than 6.0 %. The modified method is simple, rapid and sensitive, and acceptable in the analysis of OPPs pesticides in water samples.  相似文献   

18.
Silica gel surface was chemically functionalized by reaction the silanol from the silica surface with 3-chloropropyltrimethoxysilane followed by reaction with Sulfasalazine. This new sorbent has been used for the preconcentration of low levels of U(VI) ions from an aqueous phase. Parameters involved in extraction efficiency such as pH, weight of the sorbent, volume of sample and eluent were optimized in batch and column methods prior to determination by spectrophotometry using arsenazo(III) reagent. The results showed that U(VI) ions can be sorbed at pH range of 5.0–6.0 in a minicolumn and quantitative recovery of U(VI) (>98.0?±?1.6%) was achieved by stripping with 2.5 mL of 0.1 mol L?1 HCl. The sorption capacity of the functionalized silica gel was 1.15 mmol g?1 of U(VI). A linear calibration graph was obtained over the concentration range of 0.02–27.0 μg mL?1 with a limit of detection of 1 μg L?1 in treatment with 1000 mL of the U(VI) solution in which the preconcentration factor was as high as 400. The method was employed to the preconcentration of U(VI) ions from spiked ground water and synthetic sea water samples.  相似文献   

19.
Electrospun polystyrene (PS) nanofibers (130–500 nm) incorporating a potassium salt of imidazole-1-carbodithioate were evaluated as potential sorbents for the pre-concentration of a model organochlorine pesticide; 1,1-dichloro-2,2bis-(4-chlorophenyl)ethylene (DDE). The efficiencies of DDE (0.25–1.0 μg L?1) adsorption by the nanofiber sorbent followed by desorption employing pressurized hot water extraction (PHWE) were investigated and monitored using gas chromatography with electron capture detection (GC-ECD). Parameters such as time, temperature and pressure of extraction, sample volume, DDE concentration and sorbent mass were optimized. The maximum adsorption of DDE (0.50 μg L?1) on electrospun PS and carbodithioate incorporated PS nanofibers was at 43.7 and 94.6%, respectively, in 20 min. Incorporation of carbodithiote doubled the adsorption efficiency of PS and achieved LOD of 0.000234 μg L?1 for DDE. The optimal DDE desorption on the PHWE system was 93.8% in 10 min. It would seem that the use of electrospun nanofibers as sorbent material with subsequent desorption by PHWE has great potential and thus warrants further investigations. This approach as it uses water as an extraction solvent for an organochlorine pesticide provides an opportunity to eliminate organic solvents, especially for procedures aimed at monitoring organic pollutants in the environment.  相似文献   

20.
A new facile, rapid, inexpensive, and sensitive method based on magnetic micro-solid phase extraction (M-??-SPE) coupled to gas chromatography?Cmass spectrometry (GC?CMS) was developed for determination of the herbicide oxadiargyl in environmental water samples. The feasibility of employing non-modified magnetic nanoparticles (MNPs) as sorbent was examined and applied to perform the extraction process. Influential parameters affecting the extraction efficiency along with desorption conditions were investigated and optimized. The limit of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) of the method under optimized conditions were 0.005 and 0.030 ng mL?1, respectively. The relative standard deviations (RSD) (n = 3) at a concentration of 0.10 ng mL?1 was 11%. The calibration curve of oxadiargyl showed linearity in the range of 0.050?C0.50 ng mL?1. The developed method was successfully applied to the extraction of oxadiargyl from spiked tap water and Zayande-Rood River water samples and the relative recoveries of 98 and 94% were obtained, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏