首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 598 毫秒
1.
A high‐throughput electrochemical microimmunosensor for the detection of biomarkers for liver fibrosis was developed. The antibodies, hyaluronic acid binding protein (HABP), lamin antibody (a‐LN) and type IV‐collagen antibody (a‐IVC), are immobilized on different electrodes of the microelectrode array by copolymerizing into the partly insulated poly(o‐phenylenediamine) by means of cyclic voltammetry. Electrochemical detection of the corresponding antigen was based on the extent of electrode insulation toward a redox probe (ferrocenemethanol) solubilized in the electrolyte as a result of the formation of the antigen‐antibody complex at the electrode surface. The microimmunosensor exhibits enough sensitivity to detect the three biomarkers at a concentration level down to 3 ng/mL. The microimmunosensor has been applied to real samples, the results agree well with those obtained by radioimmunoassay (RIA). With the possibility of being portable and considering its ease of use, robustness, and simplicity, the microimmunosensor has great potential as a tool for the screening and early detection of liver fibrosis.  相似文献   

2.
A novel and highly sensitive electrochemical immunosensor was developed for the detection of protein biomarker tumor necrosis factor‐alpha (TNF‐α) based on immobilization of TNF‐α‐antibody (anti‐TNF‐α) onto robust nanocomposite containing gold nanoparticles (AuNP), multiwalled carbon nanotubes (MWCNTs) and ionic liquid (1‐buthyl‐3‐methylimidazolium bis (trifluoromethyl sulfonyl)imide). Functionalized MWCNT‐gold nanoparticle was produced by one‐step synthesis based on the direct redox reaction. The electrochemical properties of nanocomposite were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The anti‐TNF‐α was immobilized or entrapped in the nanocomposite and used in a sandwich type complex immunoassay with anti‐TNF‐α labeled with horseradish peroxidase as secondary antibody. Under optimum conditions, the immunosensor could detect TNF‐α in a linear range from 6.0 to 100 pg mL?1 with a low detection limit of 2.0 pg mL?1. The simple fabrication method, high sensitivity, good reproducibility, stability, as well as acceptable accuracy for TNF‐α detection in human serum samples are the main advantages of this immunosensor, which might have broad applications in protein diagnostics and bioassay.  相似文献   

3.
We report for the first time sinapic acid (SA) sensing based on nanocomposite comprising electrochemically tuned gold nanoparticles (EAuNPs) and solvothermally reduced graphene oxide (rGO). The synthesized EAuNPs, rGO, and EAuNPs‐rGO nanocomposite were characterized using X‐ray diffraction (XRD), transmission electron microscopy (TEM), selected area electron diffraction (SAED), particle size analysis, and Raman spectroscopy. A proof‐of‐concept electrochemical sensor for SA was developed based on synthesized EAuNPs‐rGO nanocomposite, which was characterized by electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The developed sensor detected SA with a linear dynamic range (LDR) between 20 μM and 200 μM and detection limit (DL) of 33.43 (±0.21) nM (RSD<3.32 %). To show the useful purpose of the sensor probe in clinical applications, SA was detected in human urine samples, which showed the percentage recovery between 82.6 % and 92.8 %. Interferences due to various molecules such as L‐cystine, glycine, alanine, serum albumin, uric acid, citric acid, ascorbic acid, and urea were tested. Long‐term stability of the sensor probe was examined, which was found to be stable up to 6 weeks. The sensor fabricated using EAuNPs‐rGO nanocomposite has many attractive features such as; simplicity, rapidity, and label‐free detection; hence, it could be a method of choice for SA detection in various matrices.  相似文献   

4.
A simple one‐step electrodeposition method is described to fabricate three dimensional ordered macroporous chitosan?prussian blue?single walled carbon nanotubes (3DOM CS?PB?SWCNTs) film onto the gold electrode surface to fabricate a copper ions (Cu2+)‐specific DNAzyme biosensor. The new sensing strategy for sensitive and selective detection of Cu2+ was based on Au nanorods (AuNRs) as signal amplification labels. The electrochemical signal of glucose increased with the concentration of Cu2+ increasing. The morphologies and electrochemistry of the composites were investigated by using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical techniques including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and so on. Linear correlations of copper ion concentration were obtained in the range from 10?18 M to 10?5 M, achieving with a limit of detection of 10?19 M (S/N=3). Parameters affecting the biosensor response such as temperature, the cleavage time and the time of hybridization were optimized. This biosensor showed a wide range, low detection limit, good reproducibility and high stability. Additionally, these striking properties endow the biosensor with a great promise for analytical applications.  相似文献   

5.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

6.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

7.
《Electroanalysis》2004,16(3):224-230
The 3′‐azido‐3′‐deoxythymidine (AZT, Zidovudine) is an antiproliferative and virostatic drug widely used in human immunodeficiency virus type 1 (HIV‐1) infection treatment. With respect to side effects of high doses and a short half‐life of AZT, a fast and simple detection method for this agent could be helpful. The aim of our study was to determine AZT levels in natural samples (urine, serum, whole blood, and cell cultures, such as the HaCaT line of keratinocytes) without their mineralization and/or purification, by means of electrochemical methods using hanging mercury drop electrode (HMDE). On this electrode, AZT undergoes irreversible reduction at the peak potential near Ep?1.1 V (vs. Ag/AgCl/3 M KCl). Reduction AZT signals were measured by cyclic voltammetry (CV), differential pulse voltammetry (DPV), square‐wave voltammetry (SWV), and constant current chronopotentiometric stripping analysis (CPSA). In phosphate buffer (pH 8) the SWV yielded the best AZT signal with the detection limit of 1 nM. The determination of AZT concentration in biological materials is affected by electroactive components, such as proteins and DNA. For monitoring the influence of these compounds, AZT reduction was performed in the presence of 10 μg/mL calf thymus ssDNA and/or 100 μg/mL bovine serum albumin. In these cases, the detection limit increased to 0.25 μM. Also studied was the AZT concentration in keratinocyte cells (HaCaT line) during cell cultivation. It has been shown that the SWV may be considered as a useful tool for the determination of AZT concentration in cell cultures, and for monitoring AZT pharmacokinetics.  相似文献   

8.
The electrochemical sensor was developed for determination of methadone (MTD) using multi‐walled carbon nanotubes (MWCNT) modified pencil graphite electrode (MWCNT‐PGE). It was found that the oxidation peak current of MTD at the MWCNT‐PGE was greatly improved compared with that of the bare‐PGE. At the MWCNT‐PGE, well‐defined anodic peak of MTD was observed at about 0.7 V (in pH 7 solution). The influence of several parameters on the determination of MTD was investigated. At optimum experimental conditions, differential pulse voltammetry (DPV) was used for determination of MTD, which exhibited a linear calibration graph of Ip versus MTD concentration in the range of 0.1–15 µM with a correlation coefficient of 0.9992. The calculated detection limit for S/N = 3 was 87 nM. It has been shown that the peaks obtained for oxidation of ascorbic acid (AA), uric acid (UA) and MTD in their mixture could be well resolved by differential pulse voltammetry, permitting us to develop a sensitive and selective electrochemical sensor for determination of MTD in the presence of AA and UA. Finally, MWCNT‐PGE was used for determination of MTD in biological samples, such as human serum and urine, using the standard addition procedure and the results were quite promising.  相似文献   

9.
In this work, a novel sandwich‐type electrochemical immunosensor with electroactive nickel hexacyanoferrate nanoparticles (NiHCFNPs) as matrix was constructed for α‐fetoprotein (AFP) detection in a signal‐off manner by using FeS2?AuNPs nanocomposite catalyzed insoluble precipitation to significantly inhibit the electrochemical signal. Initially, the NiHCFNPs with excellent electrochemical property was modified on the electrodeposited nano‐Au electrode to obtain a strong initial electrochemical signal. Subsequently, another nano‐Au layer was formed for immobilization of capture antibody (Ab1). In the presence of target AFP, the prepared FeS2?AuNPs‐Ab2 bioconjugate could be specifically recognized and immobilized on electrode through the sandwich‐type immunoreaction. The FeS2 with large specific surface areas were used as scaffolds to load abundant mimicking enzyme AuNPs. With the help of hydrogen peroxide (H2O2), FeS2?AuNPs with peroxidase‐like activity accelerated the 4‐chloro‐1‐naphthol (4‐CN) oxidation with generation of insoluble precipitation on electrode, which would greatly hinder the electron transfer and thus caused the decrease of electrochemical signal for quantitative determination of AFP. This approach achieved a wide dynamic linear range from 0.0001 to 100 ng mL?1 with an ultralow limit detection of 0.028 pg mL?1. Especially, the proposed AFP immunosensor can be applied to detect human serum samples with satisfactory results, indicating a potential application in clinical monitoring of tumor biomarkers.  相似文献   

10.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

11.
An ultrasensitive label‐free electrochemical aptasensor was developed for selective detection of chloramphenicol (CAP). The aptasensor was made using screen‐printed gold electrode modified with synthesized gold nanocube/cysteine. The interactions of CAP with aptamer were studied by cyclic voltammetry, square wave voltammetry (SWV) and electrochemical impedance spectroscopy. Under optimized conditions, two linear calibration curves were obtained for CAP determination using SWV technique, from 0.03 to 0.10 µM and 0.25–6.0 µM with a detection limit of 4.0 nM. The aptasensor has the advantages of good selectivity and stability and applied to the determination of CAP in human blood serum sample.  相似文献   

12.
We report for the first time a microwave assisted, one pot, direct, and facile synthesis of monodispersed iron‐gold bimetallic nanoparticles (BNPAu‐Fe) using glucose as a reducing agent in merely 90 s. The as such synthesized BNPAu‐Fe were thoroughly characterized using UV‐Vis, XRD, TEM, EDX, elemental mapping, and raman spectroscopy. These BNPAu‐Fe were further impregnated with reduced graphene oxide (rGO) and coated onto glassy carbon electrode (GCE) to develop a sensor probe for label free electrochemical detection of acetaminophen, which is considered to be a most potent biomarker related to non‐alcoholic fatty liver disease. The sensor probe was systematically characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The BNPAu‐Fe‐rGO nanocomposite matrix showed the sensing of acetaminophen with a wide dynamic range between 50 and 800 nM with detection limit (DL) of 0.14 nM (±0.05) nM (RSD<4.12 %) that was lower compared to previously reported acetaminophen sensors. To show the practical application of the sensor probe, acetaminophen was detected in human urine samples, which showed the percentage recovery between 86.65 % and 91.32 %. To the best of our knowledge, this is the first report where BNPAu‐Fe impregnated rGO was used to detect acetaminophen. Interferences due to various molecules such as glucose, serum albumin, glycine, glutamic acid, alanine, citric acid, and ascorbic acid were tested individually and in mixed sample. Long‐term stability of sensor probe was examined which was found to be stable up to 12 weeks. The sensor fabricated using BNPAu‐Fe‐rGO nanocomposite has many attractive features such as; simplicity, rapidity, and label free detection, hence it could be a method of choice for acetaminophen detection in clinical settings.  相似文献   

13.
Glucose concentration monitoring is important for the prevention, diagnosis and treatment of diabetes. In this work, a composite material of AgNPs/MOF‐74(Ni) was prepared for electrochemical determination of glucose. AgNPs/MOF‐74(Ni) was characterized by X‐ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X‐ray photoelectron spectroscopy (XPS). The electrochemical properties of the glassy carbon electrodes modified with the AgNPs/MOF‐74(Ni) composites were characterized by cyclic voltammetry (CV) and current‐time curve (I‐t curve) with three electrode system. The determination of glucose with the electrode modified by AgNPs/MOF‐74(Ni) has a linear range of 0.01~4 mM with the correlation coefficient (R2) of 0.994. The detection limit is 4.7 μM (S/N=3) and the sensitivity is 1.29 mA ? mM?1 ? cm?2. In addition, this sensing system possesses reasonable reproducibility and stability. The good performance of electrochemical determination for glucose is attributed to the concerted effect of silver nanoparticles and MOF‐74(Ni) on the promotion of glucose oxidation  相似文献   

14.
The ionic liquid (IL) modified chemically activated (CA) pencil graphite electrodes (PGEs) were developed for label‐free voltammetric detection of miRNA‐34a, and implemented to the real samples. Firstly, the electrochemical characterization of unmodified PGE, CA‐PGE, IL‐PGE and IL‐CA‐PGE was performed by cyclic voltammetry (CV) as well as their DNA binding capacity was studied by electrochemical impedance spectroscopy (EIS) technique. The microscopic characterization of the surface of each electrodes was investigated by scanning electron microscopy (SEM). Differential pulse voltammetry (DPV) technique was used for measuring the oxidation signal of guanine in order to perform a label‐free voltammetric monitoring of a full‐match hybridization specific to miRNA‐34a. The selectivity of biosensor was tested against to miRNA‐155, miRNA‐660 as well as to the mismatch sequence of miRNA‐34a. The further selectivity of this proposed biosensor was studied in the mixture of samples containing miRNA‐34a with other miRNAs (1 : 1). The voltammetric detection of miRNA‐34a was also explored in the artificial serum medium as fetal bovine serum (FBS) and also in total RNA samples isolated from HUH‐7 human hepatocellular carcinoma cell line.  相似文献   

15.
A detailed procedure for the analysis of exogenous dehydroepiandrosterone (DHEA) in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been established for detecting doping with DHEA. The average delta-value (parts per thousand difference of (13)C/(12)C ratio from the isotope ratio standard) of 26 synthetic steroids commercially available was -30.1 +/- 2.6, and was significantly lower than that of human endogenous DHEA in urine of the world class athletes who had participated in the XVIIth Olympic Winter Games (-20.3 +/- 2.1, n = 446). Although large inter-individual variations of urinary DHEA excretion were observed following a single oral administration of 50 mg of DHEA, no significant inter-individual difference was found when the excretion of exogenous DHEA was monitored in terms of delta-values using GC/C/IRMS; the minimum delta-values were observed around 6-8 h after the administration, and the values returned to the base level at over 72 h after the dosing. Thus, the deviations in delta-values of DHEA and its diol metabolites are considered to be conclusive evidence for detecting doping with DHEA. Some successful cases of detection of doping with DHEA from athletes are also reported.  相似文献   

16.
A novel array silver nanoparticles and Rutin complex film modified paraffin‐impregnated graphite electrode was proposed in this work (denoted as Ag/Rutin/WGE). The characteristics were investigated by the field emission scanning electron microscopy (FE‐SEM), infrared spectra (IR), UV‐visible (UV), X‐ray photoelectron spectroscopy (XPS) and electrochemical techniques. Silver ions were gradually chelated by polyrutin film at 4′‐oxo‐5′‐OH and 5‐OH‐4‐oxo sites accompanying adsorption, then. Silver nanoparticles were highly‐dispersed electrodeposited on polyrutin film. The electrochemical behaviors of tyrosine (Tyr) and tryptophan (Trp) were studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The Ag/Rutin/WGE electrode shows overlapping catalysis for the oxidation of Tyr and Trp. The linear response of Tyr and Trp were 0.3–10.0 and 0.7–70.0 μM with detection limit of 0.07 and 0.1 μM in a signal‐to‐noise ratio of 3.  相似文献   

17.
We investigated an influence of amine adlayer on electrochemical sensing performances for uric acid detection on reduced graphene oxide (RGO)‐decorated indium‐tin oxide electrode surfaces. Various amine‐terminated molecules including aminoethyl aryldiazonium cation, 2,2′‐(ethylenedioxy)bis(ethylamine), 3‐aminopropyltriethoxysilane, polyethyleneimine were introduced as adlayers to electrostatically immobilize RGO on the electrode surfaces. The anodic oxidation current of uric acid was observed on the various surfaces with differential pulse voltammetry. The current was highly enhanced by electrocatalytic activity of RGO. The sensing performances including linearity, sensitivity, limit of detection, and correlation coefficient were measured and compared. The adlayer with 3‐aminopropyltriethoxysilane showed the best performances on the RGO‐modified surface.  相似文献   

18.
《Electroanalysis》2005,17(2):155-161
A highly sensitive immunosensor based on immobilization of hepatitis B surface antibody (HBsAb) on platinum electrode (Pt) modified silver colloids and polyvinyl butyral (PVB) as matrixes has been developed for potentiometric immunoanalysis to detect hepatitis B surface antigen (HBsAg) in this study. HBsAb molecules were immobilized successfully on nanometer‐sized silver colloid particles associated with polyvinyl butyral on a platinum electrode surface. The modification procedure was electrochemically monitored by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The HBsAb‐silver‐PVB‐modified electrode exhibited direct electrochemical behavior toward HBsAg. The factors influencing the performance of the resulting immunosensor were studied in detail. More than 94.7% of the results of human serum samples obtained by this method were in agreement with those obtained by enzyme‐linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited a sigmoid curve with log HBsAg concentration, high sensitivity (39.8 mV/decade), wide linear range from 16.0 to 800 ng mL?1 with a detection limit of 3.6 ng mL?1, fast potentiometric response (<3 min) and long‐term stability (>4 months). The response mechanism of the immunosensors was also studied with AC impedance techniques.  相似文献   

19.
Poly(o‐methoxyaniline) (POMA) and poly(o‐toluidine) (POT) salts doped with different acids (methanesulphonic acid (MeSA), trifluoroacetic acid (TFA), and hydrochloric acid (HCl)) were synthesized by using solid‐state polymerization method. The polymers were characterized by Fourier transform infrared (FTIR) spectra, ultraviolet–visible (UV–Vis) spectrometry, X‐ray diffraction (XRD), cyclic voltammetry (CV), and conductivity measurements. Transmission electron microscopy (TEM) was done to study the morphologies of POMA and POT salts. The FTIR and UV‐Vis absorption spectra revealed that the reduced phase was predominant in POMA salts, and the pernigraniline phase was predominant in POT salts. It was found that POMA salts displayed higher doping level and conductivity. In contrast, POT salts were lower at doping levels and conductivity. In accordance with these results, the electrochemical activity was also found to be lower in POT salts. The XRD patterns showed that the POMA salts displayed higher crystallinity than POT salts. The results from TEM revealed that the morphologies of POMA salts were different from those of POT salts. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper, a high‐sensitivity electrochemical sensor based on platinum (Pt) doped nickel oxide (NiO) nanoparticles and multi‐walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (Pt?NiO/MWCNTs/GCE) has been developed to determine piroxicam (PIR) and amlodipine (AML) simultaneously. The electrochemical behavior of PIR and AML at the proposed sensor has been investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. Pt doped NiO nanoparticles were synthesized by the sol‐gel procedure and were investigated using X‐ray diffraction (XRD), energy dispersive X‐ray spectroscopy (EDX) and field emission scanning electron microscopy (FESEM) techniques. DPV responses of PIR and AML increased linearly with their concentration in wide linear dynamic ranges of 0.6–320.0 μM and 1.0–250.0 μM, respectively. The limits of detection were 0.061 μM for PIR and 0.092 μM for AML. The excellent analytical figure of merits of the proposed modified electrode leads to application of it promising electrochemical sensor to determine PIR and AML in human serum and urine with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号