首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
A new electrochemical sensor based on Poly(Isoleucine) modified glassy carbon electrode decorated with platinum nanoparticles (Pt/Poly(Isoleucine)/GCE) was developed for sensitive individual and simultaneous determination of hydroquinone (HQ) and catechol (CC). Scanning electron microscopy (SEM), Electrochemical impedance spectroscopy (EIS), Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) were performed in order to characterize the Pt/Poly(Isoleucine)/GCE nanocomposite. For simultaneous determination of HQ and CC, Pt/Poly(Isoleucine)/GCE showed wide linear range between the 0.01–100.0 μM. The detection limits were 0.006 μM for HQ and 0.005 μM for CC. The Pt/Poly(Isoleucine)/GC electrode exhibited good sensitivity and reliability in the simultaneous electroanalysis of two isomers in PBS of pH 7.5. The modified electrode was used to detect the isomers in naturel samples.  相似文献   

2.
《Electroanalysis》2017,29(4):1088-1094
We delineate the electrochemical preparation of cobalt hydroxide nanoflakes Co(OH)2 NFs on multi‐walled carbon nanotubes (MWCNTs) by potentiostatic methods. The preparation was done on the surface of glassy carbon electrode (GCE). The prepared nanocomposite was characterized by field emission scanning electron microscopy (FESEM), X‐ray diffraction spectroscopy (XRD) and X‐ray photo electron spectroscopy (XPS). The resulting f‐ MWCNTs/Co(OH)2 NFs modified GCE exhibits a good electrocatalytic activity for the oxidation of hydrazine in terms of decreasing over potential and increasing peak current. The modified electrode holds good in the linear range from 0.5 to 15.5 μM with limit of detection as 87.5 nM. The sensitivity of our modified electrode is calculated to be 5733 μA/mM cm‐2. Remarkably, the obtained LOD value of our sensor is very lower compared to the recommended concentration of hydrazine in water by World health organization (WHO) and Environmental protective agency (EPA). The modified electrode detects hydrazine selectively even in the presence of common interferants. Various water samples were chosen to study the practical feasibility of our sensor. The sensor also exhibited an appreciable stability, repeatability and reproducibility.  相似文献   

3.
《Electroanalysis》2018,30(2):274-282
Reduced Graphene oxide/ZnO nanoflowers ( rGO/ZnO‐NFs ) composite has been synthesized in‐situ using asymmetric Zn complex ( 1 ) as a single‐source molecular precursor (SSMP) with GO at 150 °C. The rGO/ZnO‐NFs composite was characterized by PXRD, UV‐vis, SEM, EDX mapping, TEM and SAED pattern to confirm its purity and morphology. The rGO/ZnO‐NFs composite shows uniform distribution of nanoflowers on graphene sheets. The modified glassy carbon electrode ( GCE ) was fabricated by drop wise layering of the rGO/ZnO‐NFs composite at the surface of the GCE without using binder. The binder free modified electrode ( GCE‐rGO/ZnO ) was explored for detection of nitroaromatics such as p‐nitro‐phenol ( p ‐NP ), 2,4‐dinitrophenol ( 2,4‐DNP ), 2,4‐dinitrotoluene ( 2,4‐DNT ) and 2,4,6‐trinitrophenol ( 2,4,6‐TNP ). The fabricated sensor showed remarkable response for the both toxicants and explosives. The LOD, sensitivity and linear range for the studied toxicants and explosives were found to be in a good range: p ‐NP= 0.93 μM, 240 μA mM−1 cm−2 and 0.2–0.9 mM; 2,4‐DNP= 6.2 μM, 203 μA mM−1 cm−2 and 0.1–0.9 mM; 2,4‐DNT= 10 μM, 371 μA mM−1 cm−2 and 0.2–0.9 mM; 2,4,6‐TNP= 16 μM, 514 μA mM−1 cm−2 and 0.2–0.9 mM, respectively.  相似文献   

4.
In this paper, a high‐sensitivity electrochemical sensor based on platinum (Pt) doped nickel oxide (NiO) nanoparticles and multi‐walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (Pt?NiO/MWCNTs/GCE) has been developed to determine piroxicam (PIR) and amlodipine (AML) simultaneously. The electrochemical behavior of PIR and AML at the proposed sensor has been investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. Pt doped NiO nanoparticles were synthesized by the sol‐gel procedure and were investigated using X‐ray diffraction (XRD), energy dispersive X‐ray spectroscopy (EDX) and field emission scanning electron microscopy (FESEM) techniques. DPV responses of PIR and AML increased linearly with their concentration in wide linear dynamic ranges of 0.6–320.0 μM and 1.0–250.0 μM, respectively. The limits of detection were 0.061 μM for PIR and 0.092 μM for AML. The excellent analytical figure of merits of the proposed modified electrode leads to application of it promising electrochemical sensor to determine PIR and AML in human serum and urine with satisfactory results.  相似文献   

5.
《中国化学会会志》2017,64(7):813-821
Zinc oxide nanoparticles (ZnO NPs ) were prepared by a simple, convenient, and cost‐effective wet chemical method using the biopolymer starch. The prepared ZnO NPs were characterized by X‐ray diffraction (XRD ), scanning electron microscopy (SEM ), energy‐dispersive X‐ray (EDX ), Fourier transform infrared (FT‐IR ), and UV ‐visible spectroscopic techniques. The average crystallite size calculated from XRD data using the Debye–Scherer equation was found to be 15 nm. The electrochemical behavior of caffeine (CAF ) was studied using a glassy carbon electrode (GCE ) modified with zinc oxide nanoparticles by cyclic voltammetry (CV ) and differential pulse voltammetry (DPV ). Compared to unmodified GCE , ZnO NPs‐ modified GCE (ZnO NPs MGCE ) exhibited excellent electrocatalytic activity towards CAF oxidation, which was evident from the increase in the peak current and decrease in the peak potential. Electrochemical impedance study suggested that the charge‐transfer capacity of GCE was significantly enhanced by ZnO NPs . The linear response of the peak current on the concentrations of CAF was in the range 2–100 μM . The detection limit was found to be 0.038 μM. The proposed sensor was successfully employed for the determination of CAF in commercial beverage samples.  相似文献   

6.
通过静电纺丝技术合成碳纳米纤维,以循环伏安法在此碳纤维上电聚合乙酸锌制备复合纳米材料作为一种新型的电化学增敏剂,用于修饰玻碳电极,开发了一种基于碳纤维和氧化锌复合材料的新型电化学传感器(ZnO/CNF/GCE)。使用循环伏安法、差分脉冲伏安法等进行电化学催化性能的研究,并优化实验条件。结果表明,与裸电极相比,在pH 5.5磷酸盐缓冲溶液中,ZnO/CNF/GCE修饰电极能使氧氟沙星的峰电流明显提升,线性范围1~200μmol/L,检测限为0.33μmol/L。该ZnO/CNF/GCE修饰电极已用于氧氟沙星滴耳液中氧氟沙星的含量测定。  相似文献   

7.
An electrochemical sensor based on poly-ethionine (Poly-ET) film modified glassy carbon electrode was developed for sensitive and simultaneous sensing of dopamine (DA) and paracetamol (PA). The electropolymerization of ethionine monomer was carried out to modify the electrode. The modified electrode was characterized by using scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The Poly-ET/GCE exhibited excellent electrocatalysis towards the sensing of DA and PA. Poly-ET/GCE showed a linear increase of current response with increase concentration of DA and PA ranging from 0.1 μM–60 μM and 0.1 μM–180 μM, respectively. The LODs were found to be 7 nM and 18 nM (S/N=3) for DA and PA, respectively. This electrochemical sensor was successfully utilized for the detection of DA and PA in pharmaceutical samples.  相似文献   

8.
A different molecularly imprinted composite film with the exploit of computational design is synthesized. The proposed composite is used for electrode modification to determine morphine. The ratio of monomer to template in optimum condition was obtained 4. The modification of the electrode was achieved by electropolymerizing L‐lysine in the presence of morphine on the surface of sodium alginate and activated carbon (SA‐AC) on glassy carbon electrode (GCE). The SA‐AC composite with special surface area suits for making sensitive sensors. Morphine showed an anodic peak in buffer solution of phosphate (pH=6.0) on MIP/SA‐AC/GCE. The optimization of the practical factors on the response and electrochemical behavior of template morphine on the modified electrode were precisely surveyed. The DPV outcomes exhibit high sensitivity for morphine detection within 0.1–1000.0 μM and limit of detection as 48 nM (S/N=3). The application of this disposable sensor in the case of urine samples was quite satisfactory.  相似文献   

9.
A new highly sensitive and selective electrochemical levofloxacin sensor based on co‐polymer‐carbon nanotube composite electrode was developed. Taurine and Glutathione were electrochemically co‐polymerized on multiwalled carbon nanotubes modified glassy carbon electrode (Poly(TAU‐GSH)/CNT/GCE) and used as a levofloxacin sensor in pH 6 phosphate buffer solution. The new composite electrode surfaces were characterized by scanning electron microscopy, atomic force microscopy and electrochemical impedance spectroscopy. Under the optimized conditions, two linear segments were obtained for increasing LEV concentrations between 20 nmol L?1‐1 μmol L?1 and 1.5 μmol L?1‐55 μmol L?1 LEV with a detection limit of 9 nmol L?1 using amperometry. Poly(TAU‐GSH)/CNT/GCE exhibited high sensitivity, selectivity with good stability. The new sensor was employed for real samples of LEV tablets and urine. Promising results were obtained with good accuracy which were also in accordance with LC‐MS/MS analysis.  相似文献   

10.
Here, Pd nanoparticles and poly(taurine) film was prepared on the glassy carbon electrode surface (Pd/Poly(TAU)/GCE) by the rapid electrochemical technique. The proposed composite surface was characterized by scanning electron microscopy(SEM), X‐ray photoelectron spectroscopy(XPS) and electrochemical impedance spectroscopy(EIS). Enhanced electron transfer ability and higher electroactive surface area were achieved at Pd/Poly(TAU)/GCE as compared to the bare GCE and polymer film electrode. The new and highly stable Pd/Poly(TAU)/GCE was employed for the individual and simultaneous determination of hydroquinone and catechol which were environmentally toxic. Under the optimized conditions, HQ and CC were individually determined by using the differantial pulse voltammetry in the linear ranges of 0.008–100 μM and 0.001–100 μM with the detection limits of (LOD) 2.1 nM and 0.68 nM, respectively. In case of simultaneous determination, LODs were found as 10 nM and 0.88 nM for HQ and CC, respectively. The content of both analytes in the real sample analysis was evaluated in the river water and tap water successfully.  相似文献   

11.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

12.
In this study, single walled carbon nanotubes (SWCNTs) were covalently functionalized by terminal ethynyl bearing subphthalocyanine (SubPc) to obtain a new hybrid material, viz. SWCNT‐SubPc (CS), via “click” reaction for the first time. The structural characterization and study of the electrochemical sensor properties of the CS hybrid material to catechin were carried out. A convenient and fast analytical method was offered for the determination of catechin. It was shown that the deposition of CS on the surface of a glassy carbon electrode (GCE) led to a 2.2 and 8‐fold increase in the differential pulse voltammetry (DPV) responses to catechin in Britton‐Robinson (BR) buffer solution (a pH of 3) in comparison with SWCNT‐modified and bare GCE, respectively. The dynamic range, detection and quantification limits of catechin were determined to be 0.1–1.5 μM, 13 nM and 43 nM, respectively. Selectivity of the suggested CS/GCE sensor was investigated on addition of a number of interfering metal ions, antioxidants and biomolecules. The applicability of the modified electrode for the detection of catechin in real tea samples such as green, rosehip fruit, Turkish and Indian black tea was demonstrated with the standard addition method. Along with the ease in fabrication and low prices, the proposed CS/GCE sensor was reproducible, selective, stable and sensitive to catechin in major types of tea samples.  相似文献   

13.
This work describes the development of a biosensor for paracetamol (PAR) determination based on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) and laccase enzyme (LAC), which was immobilized by means of covalent crosslinking using glutaraldehyde. Voltammetric investigations were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The biosensor was characterized by Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FT‐IR). The results showed that the use of MWCNT/LAC composite increased the sensor sensitivity, compared to bare glassy carbon electrode. Factors affecting the voltammetric signals such as pH, ionic strength, scan rate and interferents were assessed. Linear range, limit of detection (LOD) and limit of quantitation (LOQ) obtained were 10–320 μmol L?1, 7 μmol L?1 and 10 μmol L? 1, respectively. The developed biosensor was successfully applied to PAR determination in urine and pharmaceutical formulations samples, with recovery varying from 99.96 to 106.20 % in urine samples and a relative standard deviation less than 1.04 % for PAR determination in pharmaceutical formulations. Therefore, the MWCNT‐LAC/GCE exhibits excellent sensitivity and can be used to PAR determination as a viable alternative in clinical analyzes and quality control of pharmaceutical formulations, through a simple, fast and inexpensive methodology.  相似文献   

14.
In this work, low‐cost and environmentally friendly natural zeolite exchanged with Mn2+ cations was used for the first time to modify the glassy carbon electrode with the aim to obtain a fast and simple sensor for voltammetric determination of paracetamol (PAR). The Mn‐zeolite/graphite modified glassy carbon electrode (MnZG?GCE) was prepared by evaporation of solvent from dispersion of the zeolite/graphite mixture with the polymer in acetone. The electrochemical characteristics of MnZG?GCE were conducted by electrochemical impedance spectroscopy and cyclic voltammetry. Compared with graphite modified GCE (G?GCE), MnZG?GCE exhibited better electrochemical parameters, which confirms the superiority of applying zeolite in the proposed sensor. The optimization of the pH‐value of supporting electrolyte and instrumental parameters were carried out. The peak current was proportional to the concentration of PAR in a phosphate buffer saline of pH 6.0 in the range from 0.029 to 0.69 mg L?1 (R=0.9997) with limit of detection of 8.8 μg L?1. Finally, the proposed electrode was successfully applied to determine the paracetamol in pharmaceutical formulation and certified reference materials. The satisfactory recoveries, which ranged from 89.2 to 102.7 %, were obtained for all studied samples. It confirmed the attractiveness of relatively inexpensive, easy to fabricate and non‐toxic MnZG?GCE in determination of PAR in complicated matrixes.  相似文献   

15.
The rapid and simple detection of bisphenol A is very important for the safety and reproduction of organisms. Here, a sensitive and reliable electrochemical sensor was established for bisphenol A detection based on the high amplification effect of copper sulfide-multi-walled carbon nanotube (CuS–MWCNT) nanocomposites. The flower-like CuS–MWCNT were successfully synthesized by a simple hydrothermal method accompanied by polyvinylpyrrolidone (PVP). Compared with bare glassy carbon electrode (GCE), CuS–MWCNT modified GCE could amplify the electrochemical signals in about ten times, which was attributed to the synergistic effect of CuS and MWCNT. The MWCNT could increase the specific surface area of electrodes and improve the electrode activity. The integration of CuS could further enhance the electrode conductivity as well as accelerate the electron transfer rate. Raman spectra and transmission electron microscope (TEM) were used to characterize the successful fabrication of CuS–MWCNT nanocomposites and its uniform and monodispersed morphology. Under optimizing conditions, the oxidation currents of bisphenol A via the differential pulse voltammetric (DPV) showed a good linear relationship with its concentration in a wide range of 0.5–100 μM, with a detection limit of 50 nM. This electrochemical sensor of bisphenol A provided a convenient and economical platform with high sensitivity and reproducibility, which had great potential in environmental monitoring.  相似文献   

16.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

17.
At present, a highly sensitive hydrogen peroxide (H2O2) sensor is fabricated by ferrocene based naphthaquinone derivatives as 2,3‐Diferrocenyl‐1,4‐naphthoquinone and 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone. These ferrocene based naphthaquinone derivatives are characterized by H‐NMR and C‐NMR. The electrochemical properties of these ferrocene based naphthaquinone are investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) on modified glassy carbon electrode (GCE). The modified electrode with ferrocene based naphthaquinone derivatives exhibits an improved voltammetric response to the H2O2 redox reaction. 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone show excellent non‐enzymatic sensing ability towards H2O2 response with a detection limitation of 2.7 μmol/L a wide detection range from 10 μM to 400 μM in H2O2 detection. The sensor also exhibits short response time (1 s) and good sensitivity of 71.4 μA mM?1 cm?2 and stability. Furthermore, the DPV method exhibited very high sensitivity (18999 μA mM?1 cm?2) and low detection limit (0.66 μM) compared to the CA method. Ferrocene based naphthaquinone derivative based sensors have a lower cost and high stability. Thus, this novel non‐enzyme sensor has potential application in H2O2 detection.  相似文献   

18.
The present work demonstrates that simultaneous determination of adrenalin (AD) and paracetamol (PAR) can be performed on single‐walled carbon nanotube/chitosan/ionic liquid modified glassy carbon electrode (SWCNT‐CHIT‐IL/GCE). The electro‐oxidations of AD and PAR were investigated with cyclic voltammetry (CV), differential pulse voltammetry (DPV) and also chronoamperometry (CA) methods. DPV experiments showed that the oxidation peak currents of AD and PAR are proportional to the corresponding concentrations over the 1–580 μmol/L and 0.5–400 μmol/L ranges, respectively. The RSD at a concentration level of 15 μmol/L AD and 15 μmol/L PAR were 1.69% and 1.82%, respectively. Finally the modified electrode was used for simultaneous determination of AD and PAR in real samples with satisfactory results.  相似文献   

19.
An electrochemical sensor was prepared using Au nanoparticles and reduced graphene successfully decorated on the glassy carbon electrode (Au/RGO/GCE) through an electrochemical method which was applied to detect Sunset Yellow (SY). The as-prepared electrode was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM) and electrochemical measurements. The results of cyclic voltammetry (CV) proved that Au/RGO/GCE had the highest catalytic activity for the oxidation of SY as compared with GCE, Au/GCE, and RGO/GCE. Differential pulse voltammetry (DPV) showed that the linear calibration curves for SY on Au/RGO/GCE in the range of 0.002 μM–109.14 μM, and the detection limit was estimated to be 2 nM (S/N = 3). These results suggested that the obtained Au/RGO/GCE was applied to detect SY with high sensitivity, low detection limit and good stability, which provided a promising future for the development of portable sensor in food additives.  相似文献   

20.
《Electroanalysis》2017,29(5):1301-1309
A sensitive electrochemical sensor was fabricated based on ceria‐graphene oxide nanoribbons composite (CeO2‐GONRs) for an antiviral drug, entecavir (ETV). It was characterized by SEM, EDAX, AFM, IR and Raman spectroscopic techniques. The electrochemical behaviour of ETV was investigated by cyclic voltammetric, differential pulse voltammetric (DPV), linear sweep voltammetric (LSV) and square wave voltammetric (SWV) methods at CeO2‐GONRs modified glassy carbon electrode. Good linearity was observed between the peak current and concentration of ETV in the range of 0.51 ‐ 100 μM with a detection limit of 0.042 μM in DPV method, 2.1 – 61.1 μM with a detection limit of 0.7 μM in LSV method and 0.1 ‐ 80 μM with a detection limit of 68.1 nM in SWV method. The proposed sensitive DPV method was successfully applied for the determination ETV in tablets and biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号