首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A voltammetric study of the oxidation of Ceftazidime (CEFT) has been carried out at the glassy carbon electrode by cyclic, differential pulse (DPV) and square wave (SWV) voltammetry. The oxidation of CEFT was irreversible and exhibited diffusion controlled process depending on pH. The oxidation mechanism was proposed and discussed. According to the linear relationship between the peak current and concentration, DPV and SWV voltammetric methods for CEFT assay in pharmaceutical dosage forms and human urine were developed. For analytical purposes, a well resolved diffusion controlled voltammetric peak was obtained in 0.1 M H2SO4 at 1.00 and 1.02 V for differential pulse and square wave voltammetric techniques, respectively. The linear response was obtained within the range of 4 × 10?6?8 × 10?5 M with a detection limit of 6 × 10?7 M for differential pulse and 4 × 10?6–2 × 10?4 M with a detection limit of 1 × 10?6 M for square wave voltammetric technique. The determination of CEFT in 0.1 M H2SO4 was possible over the 2 × 10?6–1 × 10?4 M range in urine sample for both techniques. The standard addition method was used for the recovery studies.  相似文献   

2.
A method for the determination of nickel(II) by stripping voltammetry is described. The method is based on the adsorptive accumulation of nickel(II) calconcarboxylic acid complex onto a hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed complex using differential pulse voltammetry. The optimum operating conditions and parameters were found to be 0.05 M NH3/NH4Cl buffer (pH = 9.5) as the supporting electrolyte, a ligand concentration of 1 × 10?6 M, accumulation potential of ?0.5 V (vs. Ag/AgCl) and accumulation time of 60 s. At the optimized conditions, the peak current is proportional to the concentration of nickel in the range of 1.7 × 10?9 to 4.7 × 10?7 M (0.1–28 ng ml?1) with a detection limit of 0.05 ng ml?1. The relative standard deviation (n = 10) at nickel concentrations of 2, 10 and 15 ng ml?1 varies in the range 0.76 to 2.1%. Possible interferences by metal ions, which are of great significance in real matrices, have been studied. The method was successfully applied to the determination of nickel content in a chocolate sample.  相似文献   

3.
《Analytical letters》2012,45(9):809-820
Abstract

The U(VI) reduction at mercury electrode in sulfuric acid solutions was examined by cyclic voltammetry (C. V.). A diffusion coefficient, D, was (5.30 ± 0.08) × 10?6 cm2/sec was obtained for the depolarizer at 25.0±0.2°C in 1 N K2SO4 (pH = 2). In 1 N K2SO4/1 N H2,SO4 systems the disproportionation of U(V) was found to occur with the constant rate of Kd/[H+] = 6.500 ± 1.000 M?2 sec?1.

In 1 M H2SO4 supporting electrolyte pure kinetic control was achieved over the range of scan rates and uranyl concentration (C) investigated, hence linear correlation between cathodic peak current and C (above 5x10?6 M) was obtained. Strong complexing oxyanions, such as phosphate and pyrosulphate, do not interfere with the cathodic peak current. Rapid determination of O/U ratios in uranium oxides and of U in mixed U-Th materials were performed respectively in 1 M H2SO4/1.5 M H3PO4 and 1 M H2SO4/0.2 M K2S204 supporting media, with a reproducibility of ± 1.3% standard deviation.  相似文献   

4.
刘宁高伟  宋俊峰 《中国化学》2006,24(11):1657-1661
Voltammetry using solid electrodes usually suffers from the contamination due to the deposition of the redox products of analytes on the electrode surface. The contamination has resulted in poor reproducibility and overelaborate operation procedures. The use of the chemical catalysis of oxidant on the reduction product of analyte not only can eliminate the contamination of analyte to solid electrodes but also can improve the faradaic response of analyte. This work introduced both the catalysis of oxidant K2S2O8 and the enhancement of surfactant Triton X-100 on the faraday response of amiodarone into an adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone. The method exhibits high sensitivity, good reproducibility and simple operation procedure. In 0.2 mol·L^-1 HOAc-NaOAc buffer (pH=5.3) containing 2.2×10^-2 mol·L^-1 K2S2O8 and 0.002% Triton X-100, the 2.5th-order derivative stripping peak current of the catalytic wave at 0.3 V (vs. Ag/AgCl) is rectilinear to amiodarone concentration in the range of 2.0×10^-10-2.3×10^-8 mol·L^-1 with a detection limit of 1.5×10^-10 mol·L^-1 after accumulation at 0 V for 30 s.  相似文献   

5.
《Analytical letters》2012,45(7):1213-1233
Abstract

Anodic waves of methimazole (I) (1-methylimidazole-2-thiol) and carbimazole (II) (1-ethoxycarbonyl-3-methyl-2-thio-4-imidazoline) on mercury electrodes correspond to mercury salt formation. Both compounds form in the thiono form a soluble complex at pH < 6, compound (I) at higher pH-values a slightly soluble salt of the thiol form. Electrode processes involving the thiol form are complicated by adsorption. Oxidation at solid electrodes occurs only at potentials more than 0.5 V more positive. For compound (I) spectrophotometry indicated pKa=12.0 ± 0.2. By d.c. polarography in 0.1 M H2SO4 containing 10% ethanol the determination of both compounds is possible between 4 × 10? and 1 × 10?3 M, by differential pulse polarography between 1 × 10? and 1 × 10?4 M, by differential pulse voltammetry at HMDE between 5 × l0?7 and 6 × 10? M.  相似文献   

6.
A procedure is proposed for the stripping voltammetric determination of N 3 ? ions at a mercury film electrode. It is based on the reduction of the mercury azide formed upon the oxidation of mercury in the presence of N 3 ? at ?0.02 to ?0.04V (in reference to an Ag/AgCl electrode) in a 0.1 M Na2SO4 supporting electrolyte solution. A linear dependence of the cathodic current peak on the N 3 ? concentration is observed in the concentration range from 4 × 10?9 to 1 × 10?3 M.  相似文献   

7.
《Analytical letters》2012,45(13):2589-2596
Abstract

Cd2+ ion was used as an electrochemical indicator to detect VB1 or Vc using square ware voltammetry (SWV) at a mercury film‐coated glassy carbon (GC) electrode. At pH=10 NH3‐NH4Cl buffer, a new cathodic peak was found at ?0.360 V (vs.SCE) by addition of thiamine, and the peak current of SWV was linear with the concentration of thiamine in the range of 1×10?6 to 4×10?3 M. On the other hand, the SWV peak current of Cd2+ at ?0.856 V linearly decreased with addition of ascorbic acid in the range of 6×10?6~10?3 M. The effects of interference, such as citric acid, DL‐malic acid, and calcium panlothenate, on thiamine or ascorbic acid determination were investigated. This method was successfully applied to the determination of thiamine or in pharmaceutical preparation.  相似文献   

8.
The voltammetric behavior of paraquat was investigated at hydroxyapatite‐modified carbon paste electrode HAP‐CPE in K2SO4. A method was developed for the detection of the trace of this herbicide, based on their redox reaction. The reduction peaks of paraquat were observed around ?0.70 V and ?1.00 V (vs. SCE) in square‐wave voltammetry. Experimental conditions were optimized by varying the accumulation time, apatite loading and measuring solution pH. Calibration plots were linear under the optimized parameters over the herbicide's concentration range 8–200×10?7 mol L?1, with a detection and quantification limits about 1.5×10?8 mol L?1 and 6.4 10?8 mol L?1, respectively.  相似文献   

9.
Controlled adsorptive accumulation at the hanging mercury drop electrode enables 0.8–11 × 10?5 M chlordiazepoxide to be quantified by differential-pulse stripping voltammetry with accumulation times of 1–3 min. With 3-min accumulation, the peak current is enhanced 12-fold for 1.0 × 10?7 M chlordiazepoxide compared to the current from differential pulse polarography. The detection limit is 0.9 × 10?9 M for 4-min accumulation. The procedure is applied to spiked human serum after preseparation of the drug on a Sep-Pak C18 cartridge.  相似文献   

10.
In this paper, a simple, convenient and sensitive electrochemical method has been developed for the determination of C.I. Direct Red 80. A gold nanoparticle modified carbon paste electrode was fabricated and used for study and sensitive determination of Direct Red 80 by cyclic voltammetry and differential pulse voltammetry. The overall analysis involved a two-step procedure: an accumulation step under open-circuit conditions, followed by voltammetric measurements of Direct Red 80 in a 0.1?M phosphate buffer solution at pH?=?3.0. The experimental conditions, such as the medium, pH and accumulation time, were optimised. The oxidation peak current was proportional to the concentration of Direct Red 80 from 5.0?×?10?8 to 5.0?×?10?7?M and 5.0?×?10?7 to 3.0?×?10?6?M, and the detection limit was 1.15?×?10?8?M (S/N?=?3). The proposed method was used to detect Direct Red 80 in natural water and sewage with good accuracy.  相似文献   

11.
The linear-sweep polarographic determination of active chlorine is based on its reaction with phenylthiourea in acidic phosphate buffer (pH 2.5) containing potassium chloride. The product, C,C-diphenyldithiodiformamidine, is strongly adsorbed and then reduced at a mercury electrode with two peaks at about ?0.35 V and ?0.87 V (vs. SCE). In the presence of 0.05 M potassium chloride, the potential of the first peak shifts positively to ?0.31 V. This peak provides high sensitivity and selectivity for the determination of traces of active chlorine. The linear range is 1×10?7?2.5×10?5 M and the detection limit is 5×10?8 M (3.6 μg l?1). The method is used for the direct determination of active chlorine in tap water. The mechanism of the reaction was studied by cyclic voltammetry, electrolysis and potentiometric titration. The first peak (?0.35 V) is ascribed to the reduction of a mercury (II) sulfide film produced by reaction of the adsorbed dithio product with mercury. In the presence of 0.05 M chloride, the formation of a mixed HgS·xHg2Cl2 film shifts the peak to ?0.31 V.  相似文献   

12.
A simple adsorptive cathodic stripping voltammetry method has been developed for antimony (III and V) speciation using 4‐(2‐thiazolylazo) – resorcinol (TAR). The methodology involves controlled preconcentration at pH 5, during which antimony(III) – TAR complex is adsorbed onto a hanging mercury drop electrode followed by measuring the cathodic peak current (Ip,c) at ?0.39 V versus Ag/AgCl electrode. The plot of Ip,c versus antimony(III) concentration was linear in the range 1.35×10?9–9.53×10?8 mol L?1.The LOD and LOQ for Sb(III) were found 4.06×10?10 and 1.35×10?9 mol L?1, respectively. Antimony(V) species after reduction to antimony(III) with Na2SO3 were also determined. Analysis of antimony in environment water samples was applied satisfactorily.  相似文献   

13.
An all solid state potentiometric sensor using anthracene thiourea derivative as ionophore was developed. It exhibited a near‐Nernstian slope of 30.8±1.0 mV/decade of activity for HPO42? ions in the concentration range of 1.0×10?7–1.0×10?3 M at pH 7.4. It displayed excellent selectivity for monohydrogen phosphate over other anions and the selectivity sequence was determined as HPO42?>SO42?>Cl?>NO3?>OAc?>I?>ClO4?. The developed sensor was evaluated for the analysis of monohydrogen phosphate ions in a standard reference material (SRM 1548) as well as in the potentiometric titration of phosphate ions with a barium chloride solution.  相似文献   

14.
《Electroanalysis》2003,15(12):1054-1059
Epinephrine (EP) could exhibit an anodic peak at a bare gold electrode, but it was very insensitive. However, when the bare gold electrode was modified with 3‐mercaptopropionic acid (3MPA) self‐assembled monolayer (3MPA SAM), the peaks of EP became more reversible and sensitive due to the accumulation and mediate efficiency of 3MPA SAM. Conditions such as solution pH, concentration of supporting electrolyte and accumulation time were optimized. Under the selected conditions (i.e., 0.02 M pH 6.8 sodium phosphate buffer, accumulation time: 2 min under open‐ circuit.), the height of the anodic peak at about 0.18 V (vs. SCE) was linear to EP concentration in the range of 2×10?7 ?1×10?6 M and 1×10?6?5×10?4 M with correlation coefficient of 0.995 and 0.999, respectively. When the 3MPA/Au was further modified with cysteamine, the interference of H2O2 and BrO3? was eliminated. But the resulting electrode still suffered from the interference of ascorbic acid. This method was used to determine the content of EP in adrenaline hydrochloride injections, and the recovery was in the range of 97.0% to 105.1%.  相似文献   

15.
The determination of trace rhenium (VII) by differential pulse polarography in the system of H2SO4-(NHsOH)2 · H2SO4-TeO2?4 is markedly improved by the addition of Nitron, which is adsorbed on the surface of mercury electrode. The limit of detection is down to 2 × 1010 M. The adsorptive peak potential is ?0.80 V (vs. SCE). In the ranges of 5 × 1010—10?8, 1 × 10?5—10?7 and 1 × 10?7—10?6M, there are good linear relationships between the peak current increment and the concentration, of which the relative standard deviations are 9.5, 6.6, 1.8% respectively with the correlation coefficients of linear regression of 0.995–0.999. The results relating to this polarographic wave show that it is an adsorption-catalytic wave. The mechanism of the electrode reaction is discussed.  相似文献   

16.
《Analytical letters》2012,45(15):2430-2443
Abstract

A highly sensitive method to determine of indium is proposed by adsorption stripping differential pulse cathodic voltammetry (AdSDPCV) method. The complex of indium ions with xylenol orange is analyzed based on the adsorption collection onto a hanging mercury drop electrode (HMDE). After accumulation of the complex at ?0.20 V vs. Ag/AgCl reference electrode, the potential is scanned in a negative direction from ?0.40 to ?0.75 V with the differential pulse method. Then, the reduction peak current of In(III)–XO complex is measured. The influence of chemical and instrumental variables was studied by factorial design analysis. Under optimum conditions and accumulation time of 60 s, linear dynamic range was 0.1–10 ng/ml (8.7 × 10?10 to 8.7 × 10?8 M) with a limit of detection of 0.03 ng/ml (2.6 × 10?10 M); at accumulation time of 5 min, linear dynamic range was 0.04–10 ng/ml (3.4 × 10?10 to 8.7 × 10?8 M) with a limit of detection of 0.013 ng/ml (1.1 × 10?10 M). The applicability of the method to analysis of real samples was assessed by the determination of indium in water, alloy, and jarosite (zinc ore) samples.  相似文献   

17.
《Electroanalysis》2006,18(12):1202-1207
A new type of current sensor, Langmuir–Blodgett (LB) film of calixarene on the surface of glassy carbon electrode (GCE) was prepared for determination of mercury by anodic stripping voltammetry (ASV). An anodic stripping peak was obtained at 0.15 V (vs. SCE) by scanning the potential from ?0.6 to +0.6 V. Compared with a bare GCE, the LB film coated electrode greatly improves the sensitivity of measuring mercury ion. The fabricated electrode in a 0.1 M H2SO4+0.01 M HCl solution shows a linear voltammetric response in the range of 0.07–40 μg L?1 and detection limit of 0.04 μg L?1 (ca. 2×10?10 M). The high sensitivity, selectivity, and stability of this LB film modified electrode demonstrates its practical application for a simple, rapid and economical determination of Hg2+ in a water sample.  相似文献   

18.
The electrochemical oxidation of vinylsulphone azo dye, Reactive Black 5 (RB5), at a glassy carbon electrode has been carried out in phosphate buffer solutions in the pH range 2.85?C11.79 employing cyclic voltammetry (CV) and differential pulse voltammetry (DPV). RB5 showed one well-defined oxidation peak at 0.560 V vs. Ag-AgCl using DPV. The oxidation process was shown to be irreversible over the pH range 2.85?C8.39 and was diffusion controlled. The linear relationship between the peak current height and RB5 concentrations allowed the differential pulse voltammetric determination of the dye over a wide concentration range, from 6.0 × 10?7 to 1.5 × 10?6 M with a detection limit of 4.0 × 10?7 M. The precision and recovery did not exceed 4.9 and 98.2%, respectively. A UV-Vis spectrophotometry method was also proposed for the determination of the RB5 in concentration range from 5.0 × 10?6 M to 1.0 × 10?5 M at ??max = 600 nm with limit of detection of 4.7 × 10?6 M and RSD of 1.8% for RB5 concentration of 1.0 × 10?5 M.  相似文献   

19.
Cathodic stripping voltammetry of selenium(IV) in 0.1 M hydrochloric acid media yielded a nonlinear calibration graph for the concentration range 10?9?10?8 M. In this concentration range, adsorptive stripping voltammetry based on adsorption of the selenium/3,3′-diaminobenzidine complex on the surface of the hanging mercury drop electrode at the deposition potential of +0.05 V (vs. SCE) is more convenient. A linear calibration graph is obtained for selenium concentrations of 3×10?9?3×10?8 M, with an accumulation time of 300 s.  相似文献   

20.
《Electroanalysis》2005,17(22):2074-2083
Carvedilol is used in the management of hypertension and angina pectoris and as an adjunct to standard therapy in symptomatic heart failure. The electrochemical oxidation of carvedilol was investigated using cyclic, linear sweep voltammetry at a glassy carbon electrode. In cyclic voltammetry, in all values of pH, the compound shows two irreversible oxidation peaks. These two peaks are related to the different electroactive part of the molecule. First and second peak currents were found as diffusion and adsorption controlled, respectively. Using second oxidation step, two voltammetric methods were described for the determination of carvedilol by differential pulse adsorptive stripping voltammetry (AdSDPV) and square‐wave adsorptive stripping voltammetry (AdSSWV) at a glassy carbon electrode. Accumulation of carvedilol was found to be optimized in 0.2 M H2SO4 solution following 275 second accumulation time at open circuit condition. Under optimized conditions, the current showed a linear dependence with concentration in the range between 2×10?7 M and 2×10?5 M in supporting electrolyte and in the range between 2×10?7 M and 1×10?5 M in spiked human serum samples for both methods. These methods were successfully applied for the analysis of carvedilol pharmaceutical dosage forms and spiked human serum samples. The repeatability and reproducibility of the methods for all media were determined. Precision and accuracy were also found. No electroactive interferences from the tablet excipients and endogenous substances from biological material were found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号