首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wu J  Lord H  Pawliszyn J 《Talanta》2001,54(4):655-672
A simple and sensitive method for the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine and hair samples was developed by coupling automated in-tube solid phase microextraction (SPME) to high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ES-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ES-MS detection were investigated. ES-MS detection conditions were studied by flow injection analysis (FIA) with direct liquid injection. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, including capillary stationary phases and sample pH. For the compounds studied, a custom-made polypyrrole (PPY) coated capillary showed superior extraction efficiency as compared to commercial capillaries. Therefore, the PPY coated capillary was selected for in-tube SPME in this study. The calibration curves of stimulants were linear in the range from 0.1 to 100 ng ml(-1) with detection limits (S/N=3) of 8-56 ng l(-1). This method was successfully applied to the analysis of the stimulants in spiked human urine and hair samples.  相似文献   

2.
A simple and sensitive method for the determination of polar pesticides in water and wine samples was developed by coupling automated in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ESI-MS detection were investigated. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, especially the stationary phases used for SPME. For the compounds studied, a custom-made polypyrrole (PPY)-coated capillary showed superior extraction efficiency as compared to several commercial capillaries tested, and therefore, it was selected for in-tube SPME. The influence of the ethanol content on the performance of in-tube SPME was also investigated. It was found that the amount of pesticides extracted decreased with the increase of ethanol content in the solutions. The ESI-MS detection conditions were optimized as follows: nebulizer gas, N2 (30 p.s.i.; 1 p.s.i.=6894.76 Pa); drying gas, N2 (10 l/min, 350 degrees C); capillary voltage, 4500 V; ionization mode, positive; mass scan range, 50-350 amu; fragmentor voltage, variable depending on the ions selected. Due to the high extraction efficiency of the PPY coating and the high sensitive mass detection, the detection limits (S/N = 3) of this method for the compounds studied are in the range of 0.01 to 1.2 ng/ml, which are more than one order of magnitude lower than those of the previous in-tube SPME-HPLC-UV method. A linear relationship was obtained for each analyte in the concentration range of 0.5 to 200 ng/ml with MS detection. This method was applied to the analysis of phenylurea and carbamate pesticides in spiked water and wine samples.  相似文献   

3.
Fan Y  Feng YQ  Da SL  Gao XP 《The Analyst》2004,129(11):1065-1069
Ketamine was used for anaesthesia originally but has emerged as an abused drug in recent years. The prevalence of ketamine abuse demands a direct and rapid determination method. It is known that in-tube solid phase microextraction (in-tube SPME) can perform extraction with a capillary linked directly to a HPLC system, providing an automated and accurate extraction procedure. In this paper, an in-tube SPME coupled to HPLC method was developed for the determination of ketamine in urine samples with a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column as the extraction phase, which is expected to provide higher extraction efficiency than open tubular capillaries. After optimizing the extraction conditions, ketamine was extracted directly from urine samples in a wide dynamic linear range of 50-10,000 ng mL(-1), with the detection limit obtained as 6.4 ng mL(-1). The intra-day and inter-day precision for the method was 1.6% and 1.7%, respectively. The urine samples from suspect addicts have been successfully analyzed within 20 min. The re-usability of the monolithic column was also confirmed as no decrease of the extraction efficiency was shown after urine extraction.  相似文献   

4.
Polypyrrole (PPY) and poly-N-phenylpyrrole (PPPY) films were prepared and applied for solid-phase microextraction (SPME). The extraction properties of the new films to volatile organic compounds were examined using an SPME device coupled with GC-flame ionization detection. A PPY-coated capillary was applied for in-tube SPME to evaluate its extraction efficiency towards less volatile compounds and ionic species. The porous surface structures of the films, revealed by scanning electron microscopy, provided high surface areas and allowed for high extraction efficiency. Compared with commercial SPME stationary phases, the new phases showed better selectivity and sensitivity toward polar, aromatic, basic and anionic compounds, due to their inherent multifunctional properties. In addition, PPY and PPPY films showed different selectivity to various groups of compounds studied, indicating that the selectivity of the films could be modified by introducing a new functional group (phenyl in PPPY) into the polymer. For in-tube SPME, the PPY-coated capillary showed superior extraction efficiency to commercial capillaries for a variety of compounds, demonstrating its potential applications for a wide range of analytes when coupled with HPLC. The sensitivity and selectivity of the films for SPME could be tuned by changing the film thickness. These results are in line with both the theoretical expectations and the results obtained by other methods, which indicate not only that PPY films can be used as new stationary phases for SPME. but also that SPME method may provide an alternative tool for studying materials like polypyrrole.  相似文献   

5.
A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700 ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine.  相似文献   

6.
Lin B  Zheng MM  Ng SC  Feng YQ 《Electrophoresis》2007,28(15):2771-2780
A successful hyphenation of in-tube solid-phase microextraction (SPME) and pressure-assisted CEC (pCEC) was developed by installing a poly(methacrylic acid-co-ethylene glycol dimethacrylate) monolithic capillary to the six-port valve in a CEC system. The device designed was appropriate for on-line in-tube SPME coupled to pCEC or muHPLC. The evaluation of this hyphenation was first carried out for in-tube SPME-muHPLC with analytical capillaries packed with 3 microm octadecyl silica (ODS). Theobromine (TB), theophylline (TP), and caffeine (CA) were chosen as model drugs for an easy comparison with the results obtained by in tube SPME-HPLC. The detection limits of these three analytes were improved more than 100 times when compared with the direct analysis by muHPLC. Then in-tube SPME-pCEC with CEC capillaries packed with perphenylcarbamoylated beta-CD-bonded silica particles was applied to the determination and analysis of propranolol enantiomers in human urine. Under optimal extraction and separation conditions, the experimental LODs were 4 and 7 ng/mL for (S)-propranolol and (R)-propranolol, respectively. The calibration curves showed good linearity for both (S)-propranolol (R(2) = 0.9997) and (R)-propranolol (R(2) = 0.9996) over the concentration range from 20 to 5000 ng/mL. Reproducibility of the method was also investigated with intra- and interday precisions lower than 10% for both enantiomers at different concentration levels.  相似文献   

7.
Fan Y  Feng YQ  Da SL  Wang ZH 《Talanta》2005,65(1):111-117
A configuration of in-tube solid-phase microextraction (SPME) coupled to HPLC was constructed by using a pump and a six-port valve combined with a PEEK tube as the pre-extraction segment. The extraction capillary was fixed directly on the HPLC six-port valve to substitute for the sample loop. The whole system could be handled easily to perform accurate on-line extraction, and the possible inaccurate quantification caused by sample/mobile phase mixing when using an autosampler could be eliminated.A β-cyclodextrin coated capillary, prepared by sol-gel method, was used as the extraction capillary for in-tube SPME. Three non-steroidal anti-inflammatory drugs, ketoprofen, fenbufen and ibuprofen, were employed to evaluate the extraction performance of the capillary. After optimizing the extraction conditions, satisfactory extraction efficiency was obtained and detection limits for ketoprofen, fenbufen and ibuprofen in diluted urine samples were 38, 18 and 28 ng/mL, respectively. The extraction reproducibility was evaluated with intra-day and inter-day precision, and the R.S.D.s obtained were lower than 4.9 and 6.9%, respectively. The capillary was proved to be reusable and the extraction efficiency did not decrease after 250 extractions.  相似文献   

8.
A biocompatible in-tube solid-phase microextraction (SPME) device was used for the direct and on-line extraction of camptothecin and 10-hydroxycamptothecin in human plasma. Biocompatibility was achieved through the use of a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column for extraction. Coupled to high performance liquid chromatography (HPLC) with UV detection, this on-line in-tube SPME method was successfully applied to the simultaneous determination of camptothecin and 10-hydroxycamptothecin in human plasma. The calculated detection limits for camptothecin and 10-hydroxycamptothecin were found to be 2.62 and 1.79 ng/mL, respectively. The method was linear over the range of 10–1000 ng/mL. Excellent method reproducibility was achieved, yielding RSDs of 2.49 and 1.59%, respectively. The detection limit (S/N=3) of camptothecin was found to reach 0.1 ng/mL using fluorescence detection. The proposed method was shown to cope robustly with the extraction and analysis of camptothecin and 10-hydroxycamptothecin in plasma samples.  相似文献   

9.
This paper compares the advantages and disadvantages of two different configurations for the extraction of triazines from water samples: (1) on-fibre solid-phase microextraction (SPME) coupled to conventional liquid chromatography (LC); and (2) in-tube SPME coupled to capillary LC. In-tube SPME has been effected either with a packed column or with an open capillary column. A critical evaluation of the main parameters affecting the performance of each method has been carried out in order to select the most suitable approach according to the requirements of the analysis. In the on-fibre SPME configuration the fibre coating was polydimethylsiloxane (PDMS)-divinylbenzene (DVB). The limits of detection (LODs) obtained with this approach under the optimized extraction and desorption conditions were between 25 and 125 microg/L. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. The in-tube SPME approach with an open capillary column coated with PDMS (30 cm x 0.25 mm I.D., 0.25 microm of thickness coating) connected to the injection valve provided LODs between 0.1 and 0.5 microg/L. In all configurations UV detection at 230 nm was used. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds.  相似文献   

10.
Takino M  Daishima S  Nakahara T 《The Analyst》2001,126(5):602-608
A method for the determination of six chlorinated phenoxy acid herbicides in river water was developed using in-tube solid-phase microextraction (SPME) followed by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from a sample directly into an open tubular capillary by repeated draw/eject cycles of the sample solution. Simple mass spectra with strong signals corresponding to [M-H]- and [M-RCOOH]- were observed for all herbicides tested in this study. The best separation of these compounds was obtained with a C18 column using linear gradient elution with a mobile phase of acetonitrile-water containing 5 mmol l-1 dibutylamine acetate (DBA). To optimize the extraction of herbicides, several in-tube SPME parameters were examined. The optimum extraction conditions were 25 draw/eject cycles of 30 microliters of sample in 0.2% formic acid (pH 2) at a flow rate of 200 microliters min-1 using a DB-WAX capillary. The herbicides extracted by the capillary were easily desorbed by 10 microliters acetonitrile. Using in-tube SPME-LC/ESI-MS with time-scheduled selected ion monitoring, the calibration curves of herbicides were linear in the range 0.05-50 ng ml-1 with correlation coefficients above 0.999. This method was successfully applied to the analysis of river water samples without interference peaks. The limit of quantification was in the range 0.02-0.06 ng ml-1 and the limit of detection (S/N = 3) was in the range 0.005-0.03 ng ml-1. The repeatability and reproducibility were in the range 2.5-4.1% and 6.2-9.1%, respectively.  相似文献   

11.
An automated on-line method for the determination of the isoflavones, daidzein and genistein, was developed using in-tube solid-phase microextraction coupled to high-performance liquid chromatography (in-tube SPME-HPLC). In-tube SPME is a new extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. Daidzein, genistein and their glucosides tested in this study were clearly separated within 8 min by HPLC using an XDB-C8 column with diode array detection. In order to optimize the extraction of these compounds, several in-tube SPME parameters were examined. The glucosides daidzin and genistin were analyzed as aglycones after hydrolysis because the glucosides were not concentrated by in-tube SPME. The optimum extraction conditions for daidzein and genistein were obtained with 20 draw/eject cycles of 40 microl of sample using a Supel-Q porous layer open tubular capillary column. The extracted compounds were easily desorbed from the capillary by mobile phase flow, and carryover was not observed. Using the in-tube SPME-HPLC method, the calibration curves of these compounds were linear in the range 5-200 ng/ml, with a correlation coefficient above 0.9999 (n = 18), and the detection limits (S/N = 3) were 0.4-0.5 ng/ml. This method was successfully applied to the analysis of soybean foods without interference peaks. The recoveries of aglycones and glucosides spiked into food samples were above 97%.  相似文献   

12.
In-tube solid-phase microextraction (SPME) is an automated version of SPME that can be easily coupled to a conventional HPLC autosampler for on-line sample preparation, separation and quantitation. It has been termed "in-tube" SPME because the extraction phase is coated inside a section of fused-silica tubing rather than coated on the surface of a fused-silica rod as in the conventional syringe-like SPME device. The new in-tube SPME technique has been demonstrated as a very efficient extraction method for the analysis of polar and thermally labile analytes. The in-tube SPME-HPLC method used with the FAMOS autosampler from LC Packings was developed for detecting polar carbamate pesticides in clean water samples. The main parameters relating to the extraction and desorption processes of in-tube SPME (selection of coatings, aspirate/dispense steps, selection of the desorption solvents, and the efficiency of desorption solvent, etc.) were investigated. The method was evaluated according to the reproducibility, linear range and limit of detection. This method is simple, effective, reproducible and sensitive. The relative standard deviation for all the carbamates investigated was between 1.7 and 5.3%. The method showed good linearity between 5 and 10000 microg/l with correlation coefficients between 0.9824 and 0.9995. For the carbamates studied, the limits of detection observed are lower than or similar to that of US Environmental Protection Agency or National Pesticide Survey methods. Detection of carbaryl present in clean water samples at 1 microg/l is possible.  相似文献   

13.
Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing of large volumes of the extracts (2.0 mL) excellent sensitivity was achieved, thus making solvent evaporation operations unnecessary. The overall recoveries ranged from 10% to 28% for the studied compounds. The relative standard deviation (RSD) ranged from 2% to 10% for intra-day variation (n=3), and the limits of detection (LODs) were < or =0.6 ng/g (dry weight). The proposed procedure was very simple and rapid (total analysis time was approximately 20 min), and the consumption of organic solvents and extractive phases was drastically reduced. The reliability of the proposed MSPD/in-tube SPME method was tested by analysing several bivalves (mussels and tellins) as well as a standard reference material (SRM).  相似文献   

14.
In-tube solid-phase microextraction (SPME) based on a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was investigated for the extraction of amphetamine, methamphetamine and their methylenedioxy derivatives. The monolithic capillary column showed high extraction efficiency towards target analytes, which could be attributed to its larger loading amount of extraction phase than conventional open-tubular extraction capillaries and the convective mass transfer procedure provided by its monolithic structure. The extraction mechanism was studied, and the results indicated that the extraction process of the target analytes was involved with hydrophobic interaction and ion-exchange interaction. The polymer monolith in-tube SPME-HPLC system with UV detection was successfully applied to the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine samples, yielding the detection limits of 1.4 - 4.0 ng/mL. Excellent method reproducibility (RSD < 2.9%) was found over a linear range of 0.05-5 microg/mL, and the time for the whole analysis was only approximately 25 min. The monolithic capillary column was reusable in coping with the complicated urine samples.  相似文献   

15.
Gold wire was coated with polypyrrole (PPY) by electropolymerization and used as a solid-phase microextraction (SPME) fiber. The adsorptive property of the coating was modified by doping with tetrasulfonated nickel phthalocyanine (NiPcTS). The efficiency and reliability of this fiber was investigated for the extraction of BTEX compounds from the headspace of water samples. Monitoring of extraction efficiency was performed by capillary GC-FID. Effects of several factors such as electropolymerization time, salt addition, exposure time and stirring speed on extraction efficiency were studied. The calibration graphs were linear in the range of 0.06 to 50 ng mL?1 and the detection limits for BTEX compounds were 20–50 pg mL?1. Comparing the results obtained using these fibers with results reported in the literature with polydimethylsiloxane (PDMS) fibers shows that under optimum conditions, the detection limits are comparable.  相似文献   

16.
A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.  相似文献   

17.
Fan Y  Zhang M  Da SL  Feng YQ 《The Analyst》2005,130(7):1065-1069
A method for the determination of endocrine disruptors, bisphenol A and 17alpha-ethinylestradiol, in environmental water samples was developed using in-tube solid-phase microextraction followed by liquid chromatography and fluorescence detection. A poly(acrylamide-vinylpyridine) monolithic capillary column was applied as the extraction media in view of its greater phase ratio than open-tubular capillaries and thus higher extraction efficiency. After optimizing the extraction conditions, bisphenol A and 17alpha-ethinylestradiol were extracted directly from water samples in a wide dynamic linear range of 0.5-1000 ng mL(-1), with the detection limits obtained as 0.064 and 0.12 ng mL(-1), respectively. The precision of the method was satisfactory with the intraday and interday RSD values smaller than 7.2%. Environmental water samples of different sources were successfully analyzed with the presented method and the monolithic capillary was proved to be robust and reusable in analyzing real water samples.  相似文献   

18.
A poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was prepared for in-tube solid-phase microextraction. Comparing with the commonly used open tubular extraction capillary, which cannot provide sufficient extraction efficiency since the ratio of its coating volume to that of the capillary void volume is relatively small, the monolithic column with greater phase ratio combined with convective mass transfer provides the possibility to improve the extraction efficiency with shorter capillary. As to poly (methacrylic acid-ethylene glycol dimethacrylate), its hydrophobic main chains and acidic pendant groups make it a superior material for extraction of basic analytes from aqueous matrix.An on-line monolithic capillary column solid phase microextraction (SPME) method was developed for determination of theobromine, theophylline and caffeine in serum samples. The high extraction efficiency was obtained for all the three analytes, yielding the detection limits of 12, 8 and 6.5 ng/mL by UV detection, respectively. Excellent method reproducibility (R.S.D. < 2.9%) was found over a linear dynamic range of 0.05-2 μg/mL in serum sample. The monolithic capillary column was proved to be reusable in coping with serum samples, which would facilitate practical determination of basic drugs.  相似文献   

19.
A simple and sensitive method for determining anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC-MS) detection. Three forms of polyaniline (PANI) films and a single form of polypyrrole (PPY) film were prepared and applied for SPME. The extraction properties of these films to anatoxin-a were examined and it was shown that leucoemeraldine form of PANI displayed a better selectivity to this compound. SPME conditions were optimized by selecting the appropriate extraction parameters, including type of coating (leucoemeraldine form of PANI at 32 microm thicknesses), salt concentration (10%, w/v), time of extraction (30 min) and stirring rate (1000 rpm). The calibration curve was linear in the range from 50 to 10,000 ng/ml, with the detection limit (S/N = 3) of 11.2 ng/ml. This method was successfully applied for the analysis of anatoxin-a in the cultured media of two species of cyanobacteria.  相似文献   

20.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号