首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A specific adsorbent for extraction of methidathion from olive oil was developed. The design of the molecularly imprinted polymer (MIP) was based on the results of the computational screening of the library of polymerisable functional monomers. MIP was prepared by thermal polymerisation using N,N’-methylene bisacrylamide (MBAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The polymers based on the itaconic acid (IA), methacrylic acid (MAA) and 2-(trifluoromethyl)acryl acid (TFMAA) functional monomers and one control polymer which was made without functional monomers with cross-linker EGDMA were also synthesised and tested. The performance of each polymer was compared using corresponding imprinting factor. As it was predicted by molecular modelling the best results were obtained for the MIP prepared with MBAA. The obtained MIP was optimised in solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC-UV) and tested for the rapid screening of methidathion in olive oil. The proposed method allowed the efficient extraction of methidathion for concentrations ranging from 0.1 to 9 mg L−1 (r2 = 0.996). The limits of detection (LOD) and quantification (LOQ) in olive oil were 0.02 mg L−1 and 0.1 mg L−1, respectively. MIPs extraction was much more effective than traditional C18 reverse-phase solid phase extraction.  相似文献   

2.
In this work, a novel method is described for the determination of bromhexine in biological fluids using molecularly imprinted solid-phase extraction as the sample cleanup technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and bromhexine as the template molecule. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of bromhexine from human serum and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning 1 mL methanol and 1 mL of deionized water at neutral pH, loading of 5 mL of the water sample (25 μg L−1) at pH 6.0, washing using 2 mL acetonitrile/acetone (1/4, v/v) and elution with 3× 1 mL methanol/acetic acid (10/1, v/v). The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of bromhexine. Results from the HPLC analyses showed that the calibration curve of bromhexine using MIP from human serum and urine is linear in the ranges of 0.5-100 and 1.5-100 μg L−1 with good precisions (3.3% and 2.8% for 5.0 μg L−1), respectively. The recoveries for serum and urine samples were higher than 92%.  相似文献   

3.
A pseudo template molecularly imprinted polymer (MIP) was prepared for methotrexate (MTX) and a RP-HPLC method combined with the MIP was developed for the determination of MTX in human serum. Because of the poor solubility of MTX in common MIP preparation solvents, trimethoprim (TMP), a molecule having the similar imprinting sites as MTX, is selected as the pseudo template. The MIP was prepared using methacrylic acid (MAA) and ethylene glycol dimethacrylate as functional monomer and cross-linker, respectively. 1H NMR study showed highly strong interaction between TMP and MAA with hydrogen bonds. Chromatographic behaviors indicated that the TMP-MIP possessed excellent affinity and selectivity for MTX. And the imprinting factor for MTX was high up to 9.5 when 7:3 of acetonitrile:methanol (v/v) was used as mobile phase. Moreover, TMP-MIP was used as the solid-phase extraction (SPE) material to enrich the target compound MTX in human serum samples for HPLC analysis. The SPE process was carefully optimized and good recoveries of MTX were obtained as 81.6–86.2% with RSD of 0.22–1.84% when the spiked concentration of MTX was 2.0–10.0 μg mL−1 in human serum samples. The results indicated that the pseudo template MIP can be applied to preconcentration, purification and analysis of MTX in clinic samples.  相似文献   

4.
A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS). Quantitative removal of atrazine from the IA columns was achieved with elution solvents of either 70% ethanol in water, 70% methanol in water, or 100% methanol. One control column was prepared using nonspecific rabbit IgG antibody. This control column did not retain any applied atrazine indicating atrazine did not bind indiscriminately to protein or the Sepharose support. The four IA columns showed reproducible coupling efficiency for the immobilization of the atrazine antibody and consistent binding and releasing of atrazine. The coupling efficiency (4.25 mg of antibody in 1 mL of resin bed) for the four IA columns ranged from 93 to 97% with an average of 96 ± 2% (2.1%). Recoveries of the 500, 50, and 5 ng mL−1 atrazine standard solutions from the four IA columns were 107 ± 7% (6.5%), 122 ± 14% (12%), and 114 ± 9% (8.0%) respectively, based on enzyme-linked immunosorbent assay (ELISA) data. The maximum loading was approximately 700 ng of atrazine for each IA column (∼0.16 μg of atrazine per mg of antibody). The IA columns could withstand 100% methanol as the elution solvent and could be reused more than 50 times with no change in performance. The IA columns were challenged with soil, sediment, and duplicate-diet food samples and effectively removed interferences from these various matrices for subsequent gas chromatography/mass spectrometry (GC/MS) or ELISA analysis. The log-transformed ELISA and GC/MS data were significantly correlated for soil, sediment and food samples although the ELISA values were slightly higher than those obtained by GC/MS. The IA column cleanup procedure coupled with ELISA analysis could be used as an alternative effective analytical method for the determination of atrazine in complex sample media such as soil, sediment, and food samples.  相似文献   

5.
The affinity of a 2,4-dichlorophenoxyacetic acid (2,4-D) molecularly imprinted polymer (MIP), which was synthesised directly in an aqueous organic solvent, for its template (2,4-D) was studied and compared with the affinity exhibited by two other reference (control) polymers, NIPA and NIPB, for the same analyte. Zonal chromatography was performed to establish the optimal selectivity, expressed as imprinting factor (IF), under chromatographic conditions more aqueous than those described so far in the literature. Frontal analysis (FA) was performed on columns packed with these polymers, using an optimized mobile phase composed of methanol/phosphate buffer (50/50, v/v), to extract adsorption isotherm data and retrieve binding parameters from the best isotherm model. Surprisingly, the template had comparable and strong affinity for both MIP (K = 3.8 × 104 M−1) and NIPA (K = 1.9 × 104 M−1), although there was a marked difference in the saturation capacities of selective and non-selective sites, as one would expect for an imprinted polymer. NIPB acts as a true control polymer in the sense that it has relatively low affinity for the template (K = 8.0 × 102 M−1). This work provides the first frontal chromatographic characterization of such a polymer in a water-rich environment over a wide concentration range. The significance of this work stems from the fact that the chromatographic approach used is generic and can be applied readily to other analytes, but also because there is an increasing demand for well-characterised imprinted materials that function effectively in aqueous media and are thus well-suited for analytical science applications involving, for example, biofluids and environmental water samples.  相似文献   

6.
The molecular recognition properties of molecular imprinted polymers which bind the carbamate function were studied. Functional monomers potentially able to form non-covalent interactions with the model molecule N,O-dibenzylcarbamate were selected on the basis of a computational approach describing possible interactions between the template and a small library of vinylic monomers. These results were in accordance with N,O-dibenzylcarbamate batch-rebinding measurements performed on several miniMIPs prepared with the same library. From these preliminary results, four polymers were prepared by thermoinduced radical polymerization, using ethylene dimethacrylate as a cross-linker, chloroform (MIP1, MIP3) or acetonitrile (MIP2, MIP4) as porogens and methacrylic acid (MIP1, MIP2) or acrylamide (MIP3, MIP4) as functional monomers. Molecular recognition features of these materials were studied by high-performance liquid chromatography. In this manner selectivity was evaluated by considering the column retention of a library of sixteen structural analogues of dibenzylcarbamate, characterized by the transformation of the carbamate into a related function, or by the alteration of the molecular structure.The experimental results show that methacrylic acid is more efficient than acrylamide as a functional monomer (imprinting factors: MIP1 = 24.1, MIP2 = 25.6, MIP3 = 13.3, MIP4 = 2.44), and that chloroform enhances polymer selectivity. As regards structural motifs which conditionate the selectivity, the carbamate function strictly controls the presence/absence of molecular recognition, while shape and dimension of the substituents modulate the recognition itself. In particular, a marked recognition for analogs which were slightly bigger than the template was observed (N-benzyl-O-phenethylcarbamate: MIP1 α = 1.13, MIP2 α = 1.41, MIP3 α = 0.97; N-phenethyl-N-benzylcarbamate: MIP1 α = 1.61, MIP2 α = 1.17, MIP3 α = 0.81; N,O-diphenethylcarbamate: MIP1 α = 0.89, MIP2 α = 1.20, MIP3 α = 0.55).  相似文献   

7.
Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g−1 for blank and 228 mg g−1 for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.  相似文献   

8.
Uniform-sized molecularly imprinted polymer (MIP) beads for metsulfuron-methyl (MSM) were firstly prepared by one-step swelling and polymerization method using 4-vinylpyridine (4-VPY) and ethylene glycol dimethacrylate (EDMA) as functional monomer and cross-linker, respectively. The preparation was optimized by varying the ratio of MSM to 4-VPY. The chromatographic behaviors of MSM and other structurally related sulfonylureas (SUs) on the resultant MIP column were evaluated. The imprinted polymer revealed specific affinity to the template and the fair resolution of SUs was also obtained. Furthermore, the uniform-sized MSM-MIP was used as the solid phase extraction (SPE) material to enrich MSM in real water samples before reversed-phase HPLC (RP-HPLC) analysis. The recovery of MSM from 100 mL of drinking water at a 50 ng/L spike level was 99.59% with R.S.D. of 1.13%. The detection limit was about 6.0 ng/L of MSM when enriching a 100 mL water sample.  相似文献   

9.
Molecularly imprinted polymers (MIPs) are tailor-made polymers with high selectivity for the template molecule. This selectivity arises from the synthetic procedure followed to prepare the MIP. In this work, the influence of process parameters on the preparation of vinblastine (VLB) imprinted polymers was presented. In the procedure of polymerization, VLB (0.1 mmol) was used as the template molecule and a commonly used initiator, azobisisobutyronitrile (AIBN), was employed to initiate the reaction at 60 °C. The influence of the following parameters was investigated: the moles of functional monomer (MAA, 0.3-1.0 mmol), the moles of cross-linker (EDMA, 1.5-5.0 mmol) and the porogenic solvent (toluene or acetonitrile). A mathematical method of uniform design was applied to optimize these selected parameters in order to increase the selectivity of MIP for template molecule. The experimental data were analyzed to obtain the regression model and the optimal conditions were achieved by optimization with uniform design software. The MIP was synthesized under the optimal conditions that 1.0 mmol of MAA and 5.0 mmol of EDMA copolymerized in toluene in the presence of 0.1 mmol of VLB. After removal of the template molecule, the obtained MIP was then employed as the sorbents of solid-phase extraction (SPE) to separate VLB from Catharanthus roseus extract. The results showed that the polymer exhibited high affinity to the template molecule and could separate and enrich VLB from C. roseus extract effectively. The recovery of VLB on the optimal MIP was 89.00%, which agreed closely with the predicted recovery. Therefore it is possible to further improve the nature of the polymer by optimizing the polymerization parameters with the method of uniform design.  相似文献   

10.
A molecularly imprinted polymer (MIP) designed to enable the selective extraction of carbamazepine (CBZ) from effluent wastewater and urine samples has been synthesised using a non-covalent molecular imprinting approach. The MIP was evaluated chromatographically in the first instance and its affinity for CBZ also confirmed by solid-phase extraction (SPE). The optimal conditions for SPE consisted of conditioning of the cartridge using acidified water purified from a Milli-Q system, loading of the sample under basic aqueous conditions, clean-up using acetonitrile and elution with methanol. The attractive molecular recognition properties of the MIP gave rise to good CBZ recoveries (80%) when 100 mL of effluent water spiked with 1 μg L−1 was percolated through the polymer. For urine samples, 2 mL samples spiked with 2.5 μg L−1 CBZ were extracted with a recovery of 65%. For urine, the linear range was 0.05-24 mg L−1, the limit of detection was 25 μg L−1 and precision, expressed as relative standard deviation at 0.5 mg L−1 (n = 3), was 3.1% and 12.6% for repeatability and reproducibility between days, respectively.  相似文献   

11.
Water-compatible pefloxacin-imprinted monoliths synthesized in a water-containing system were used for the selective extraction of fluoroquinolones (FQs). The MIP monolith was synthesized by using methacrylic acid as the functional monomer, di(ethylene glycol) dimethacrylate as a cross-linker and methanol–water (10:3, v/v) as the porogenic solvent. The ability of the derivated MIP for selective recognition of FQs (ciprofloxacin, difloxacin, danofloxacin and enrofloxacin) and quinolones (flumequine, and oxolinic acid) was evaluated. The derivated monolith showed high selectivity and was able to distinguish between FQs and quinolones. A simple rapid and sensitive method using polymer monolith microextraction (PMME) based on the MIP monolith combined with HPLC with fluorescence detection was developed for the determination of four FQs from milk samples. Owing to the unique porous structure and flow-through channels in the network skeleton of the MIP monolith, phosphate buffer diluted milk samples were directly supplied to PMME; allowing non-specific bound proteins and other biological matrix to be washed out, and FQs to be selectively enriched. The limit of detection of the method was 0.4–1.6 ng/mL and recovery was 92.4–98.2% with relative standard deviations less than 5.9%.  相似文献   

12.
An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N′-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25–2.5 mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost.  相似文献   

13.
Tianhe Jiang  Baolin Chu  Wei Yan 《Talanta》2009,78(2):442-447
A molecularly imprinted polymer (MIP) has been synthesized by a thermo-polymerization method using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, acetonitrile as porogenic solvent, and 17β-estradiol as template. The MIP showed obvious affinity for 17β-estradiol in acetonitrile solution, which was confirmed by absorption experiments. After optimization of molecularly imprinted solid-phase extraction (MISPE) conditions, three structurally related estrogenic compounds (17β-estradiol, estriol, and diethylstilbestrol) were used to evaluate the selectivity of the MIP cartridges. The MIP cartridges exhibited highly selectivity for E2, the recoveries were 84.8 ± 6.53% for MIPs and 19.1 ± 1.93% for non-imprinted polymer (NIP) cartridges. The detection and quantification limits correspond to 0.023 and 0.076 mg L−1. Furthermore, the MISPE methods were used to selectively extract E2 from fish and prawn tissue prior to HPLC analysis. This MISPE-HPLC procedure could eliminate all matrix interference simultaneously and had good recoveries (78.3-84.5%).  相似文献   

14.
In this paper we describe the synthesis, characterisation and use of two distinct molecularly imprinted polymers (MIPs) prepared using esters of p-hydroxybenzoic acid (parabens) as templates: one MIP was synthesised by precipitation polymerisation using a semi-covalent molecularly imprinting strategy with methyl paraben as the template/target (MIP 1); the second MIP was prepared in monolithic form through a conventional non-covalent molecular imprinting strategy, with butyl paraben as the template (MIP 2). MIP 1 recognized methyl paraben, showed cross-selectivity for other parabens analytes used in the study and higher affinity towards these compounds than did a non-imprinted control polymer. Similarly, MIP 2 demonstrated higher affinity towards paraben analytes than a non-imprinted control polymer.For the analysis of environmental water samples, a solid-phase extraction (SPE) protocol was developed using MIP 2 as sorbent, and results were compared to a SPE using a commercial sorbent (Oasis HLB). With MIP 2 as sorbent and butyl paraben as target, when percolating 500 mL of river water spiked at 1 μg L−1 through the SPE cartridge, and using 1 mL of isopropanol as cleaning solvent, a higher recovery of butyl 4-hydroxybenzoate (butyl paraben) and a cleaner chromatogram where achievable when using the MIP compared to the commercial sorbent.  相似文献   

15.
A restricted access media–molecularly imprinted polymer (RAM–MIP) for cyclobarbital has been developed for selective extraction of antiepileptics in river water samples. The RAM–MIP was prepared using 4-vinylpyridine and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and polymerization method followed by a surface modification technique. The RAM–MIP for cyclobarbital showed molecular recognition abilities for phenobarbital, amobarbital and phenytoin as well as cyclobarbital. Thus, selective analysis of antiepileptics in river water samples was attained with RAM–MIP extraction followed by column-switching liquid chromatography–tandem mass spectrometry. The concentrations of phenobarbital and phenytoin in river water samples were about 15 and 4 ng/L, respectively, while that of amobarbital was below the limit of quantitation.  相似文献   

16.
We have investigated the effect of buffer solution composition and pH during the preparation, washing and re-loading phases within a family of acrylamide-based molecularly imprinted polymers (MIPs) for bovine haemoglobin (BHb), equine myoglobin (EMb) and bovine catalyse (BCat). We investigated water, phosphate buffer saline (PBS), tris(hydroxymethyl)aminomethane (Tris) buffer and succinate buffer. Throughout the study MIP selectivity was highest for acrylamide, followed by N-hydroxymethylacrylamide, and then N-iso-propylacrylamide MIPs. The selectivity of the MIPs when compared with the NIPs decreased depending on the buffer conditions and pH in the order of Tris > PBS > succinate. The Tris buffer provided optimum imprinting conditions at 50 mM and pH 7.4, and MIP selectivities for the imprinting of BHb in polyacrylamide increased from an initial 8:1 to a 128:1 ratio. It was noted that the buffer conditions for the re-loading stage was important for determining MIP selectivity and the buffer conditions for the preparation stage was found to be less critical. We demonstrated that once MIPs are conditioned using Tris or PBS buffers (pH7.4) protein reloading in water should be avoided as negative effects on the MIP's imprinting capability results in low selectivities of 0.8:1. Furthermore, acidifying the pH of the buffer solution below pH 5.9 also has a negative impact on MIP selectivity especially for proteins with high isoelectric points. These buffer conditioning effects have also been successfully demonstrated in terms of MIP efficiency in real biological samples, namely plasma and serum.  相似文献   

17.
In this work, a novel molecularly imprinted polymer (MIP) for use as a solid phase extraction sorbent was developed for the determination of coenzyme Q10 (CoQ10) in liver extract. CoQ10 is an essential cofactor in mitochondrial oxidative phosphorylation and a powerful antioxidant agent found in low concentrations in biological samples. This fact and its high hydrophobicity make the analysis of CoQ10 technically challenging. Accordingly, a MIP was synthesised using coenzyme Q0 as the template, methacrylic acid as the functional monomer, acetonitrile as the porogen, ethylene glycol dimethacrylate as the crosslinker and benzoyl peroxide as the initiator. Various parameters affecting the polymer preparation and extraction efficiency were evaluated. Morphological characterisation of the MIP and its proper comparison with C18 as a sorbent in solid phase extraction were performed. The optimal conditions for the molecularly imprinted solid phase extraction (MISPE) consisted of 400 μL of sample mixed with 30 mg of MIP and 600 μL of water to reach the optimum solution loading. The loading was followed by a washing step consisting of 1 mL of a 1-propanol solution (1-propanol:water, 30:70,v/v) and elution with 1 mL of 1-propanol. After clean-up, the CoQ10 in the samples was analysed by high performance liquid chromatography. The extraction recoveries were higher than 73.7% with good precision (3.6–8.3%). The limits of detection and quantification were 2.4 and 7.5 μg g−1, respectively, and a linear range between 7.5 and 150 μg g−1 of tissue was achieved. The new MISPE procedure provided a successful clean-up for the determination of CoQ10 in a complex matrix.  相似文献   

18.
The synthesis of a T-2 toxin imprinted polymer and its application in food analysis are reported for the first time. A molecularly imprinted polymer (MIP) for the selective recognition of T-2 toxin (T-2) was synthesized by bulk polymerization. Methacrylamide and ethyleneglycol dimethacrylate were applied as functional monomer and cross-linker, respectively. Molecularly imprinted solid-phase extraction (MISPE) procedures were optimized for further application in the analysis of T-2. Scatchard plot analysis revealed that two classes of imprinted binding sites were formed in the imprinted polymer. The dissociation constant (KD) of the higher affinity binding sites was 7.0 μmol/l, while the KD of the lower affinity binding sites was 54.7 μmol/l. The performance of the MIP throughout the clean-up of spiked maize, barley and oat sample extracts was compared with the results obtained when using non-imprinted polymer, OASIS HLB® and immunoaffinity columns (IAC). Depending on the food matrix and the spiked concentration, recoveries after MISPE and non-imprinted solid-phase extraction varied respectively from 60% to 73% and from 21% to 57%. Recoveries obtained after clean-up using OASIS HLB® and IAC were in the range of 74–104% and 60–85%, respectively. Although highest recoveries were obtained with OASIS HLB® sorbents, the designed MIP and the IAC were superior regarding selectivity, cross-reactivity, matrix effect, limits of detection (LOD) and limits of quantification (LOQ). Depending on the matrix, LOD after MISPE ranged from 0.4 μg/kg to 0.6 μg/kg and LOQ from 1.4 μg/kg to 1.9 μg/kg. LOD and LOQ after OASIS HLB® clean-up varied from 0.9 μg/kg to 3.5 μg/kg and from 3.1 μg/kg to 11.7 μg/kg, respectively. The LOD and LOQ values obtained with IAC were in the range of 0.3–2.3 μg/kg and 1.0–7.7 μg/kg, respectively. Analysis of 39 naturally contaminated samples (maize, barley and oat) by liquid chromatography tandem mass spectrometry revealed that the MIP could be an excellent alternative for clean-up of contaminated food samples.  相似文献   

19.
A water compatible molecularly imprinted polymer (MIP) using cyromazine as a mimic template, methacrylic acid as the functional polymer and ethylene glycol dimethacrylate as the cross-linker was synthesized and used to extract melamine from feed and milk samples via a molecularly imprinted solid-phase extraction (MISPE) protocol. Optimum retention of melamine on the MISPE cartridge was achieved using methanol, and the interferences in the samples were effectively washed out. The binding capacity of the polymer toward melamine was found to be about 500 μg of melamine/g of polymer. The recoveries of 2 μg and 20 μg melamine standard spiked into water extract of blank feeds and milk samples were between 83.4% and 103%, with relative standard deviation <5.6%. The cyromazine-MIP demonstrated high cross-reactivity for melamine and low affinity to cyanuric acid. The ionic bond interaction was regarded as the main factors that dominated the retention of the melamine on the MISPE cartridge.  相似文献   

20.
This work reports the preparation of a molecularly imprinted polymer (MIP) for selective catalytic detection of serotonin (5-hydroxytryptamine, 5-HT). The process is based on the synthesis of polymers with hemin introduced as the catalytic center to mimic the active site of peroxidase. The copolymer MIP, containing artificial recognition sites for 5-HT, has been prepared by bulk polymerization using methacrylic acid (MAA) and hemin as the functional monomers, and ethylene glycol dimethacrylate (EGDMA) as the cross-linker. For the determination of 5-HT, a flow injection analysis system coupled to an amperometric detector was optimized using multivariate analysis. The effects of different parameters, such as pH, buffer flow rate, buffer nature, peroxide concentration and sample volume were evaluated. After optimizing the experimental conditions, a linear response range from 1.0 up to 1000.0 μmol L−1 was obtained with a sensitivity of 0.4 nA/μmol L−1. The detection limit was found to be 0.30 μmol L−1, while the precision values (n = 6) evaluated by relative standard deviation (R.S.D.) were, respectively, 1.3 and 1.7% for solutions of 50 and 750 μmol L−1 of 5-HT. No interference was observed by structurally similar compounds (including epinephrine, dopamine and norepinephrine), thus validating the good performance of the imprinted polymer. The method was applied for the determination of 5-HT in spiked blood serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号