首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
This work aimed to immobilize the antibody anti-galectin-3 onto polysiloxane–polyvinyl alcohol (POS-PVA) support, to evaluate its capacity to capture the serum antigen galectin-3 and to quantify by ELISA the antigen levels in sera from patients with prostatic adenocarcinoma (PA) and benign prostatic hyperplasia (BPH) and healthy individuals. Also, for comparative effect, the galectin-3 expression in the prostate tissue through immunohistochemistry was evaluated. The optical density (galectin-3 level) values established for the sera from PA and BPH patients were lower compared with those found for the healthy individuals. Galectin-3 immunohistochemically showed a significant increase and reduction of the cytoplasmatic protein expression in BPH and PA, respectively, compared with the normal prostate. These results showed that POS-PVA disks could be used as solid phase to immobilize serum galectins and in immunoassays procedures for the correspondent IgG anti-galectins detection in human sera.  相似文献   

2.
Protein–protein interactions and protein complex/aggregate formation play an essential role in almost all biological functions and activities. Through a nanoparticle aggregation immunoassay, we discovered that some proteins are substantially more complexed/aggregated in cancer tissues than normal tissues. This study examined four biomarkers proteins, CA125, CEA (carcinoembryonic antigen), CA19-9 and PAP (prostatic acid phosphatase) in ovarian, colon and prostate tissue lysates. The most exciting results were observed from the PAP assay of prostate tissues: prostate cancer can be clearly distinguished from normal prostate and prostate with benign conditions such as BPH (benign prostate hyperplasia) based on the complex/aggregation level of PAP in prostate tissue lysates. The complex/aggregate level of a protein can be potential biomarkers for cancer detection and diagnosis.  相似文献   

3.
Conclusion The determination of PAP in plasma samples with the new IEA improves the analytical specifity and appears to be superior to the serum RIA method. It allows a clearer distinction of prostatic carcinoma patients, especially in earlier stages of the disease, from those with benign prostatic hyperplasia. Although it, too, certainly cannot be regarded as suitable for a general screening for prostatic cancer, it may serve as an useful additional aid in the diagnosis and therapy-monitoring of the disease.
Immunoenzymtest zur Bestimmung der prostataspezifischen sauren Phosphatase in Plasmaproben
  相似文献   

4.
Serum neuron-specific enolase (NSE) levels were studied in 105 patients with malignant neoplasms (lung cancer 38, others 67), 13 patients with various benign diseases and 7 healthy adults. The mean serum NSE level in adult control subjects was 7.4 +/- 0.8 ng/ml, and cut off level was decided 10 ng/ml. Serum NSE levels were elevated in 14/38 (37%) of patients with lung cancer and in 14/67 (21%) of patients with the other malignant neoplasms. In patients with benign diseases, serum NSE level was elevated only in one patient with pituitary adenoma. In 7 patients with small cell lung cancer, the positive rate was higher (86%) than in those with non-small cell lung cancer (26%), and serum NSE levels were higher than 25 ng/ml except one case. There was no correlation between serum NSE and CEA (carcinoembryonic antigen) levels in patients with small cell lung cancer, also in patients with lung cancer. The measurement of serum NSE level seemed to be useful for diagnosis in patients with small cell lung cancer.  相似文献   

5.
Human seminal plasma contains a large array of proteins required for the normal physiology and metabolism of spermatozoa. These are mainly secreted from prostate epithelium, testes, and seminal vesicles. Fortunately, many of these are found to be present at elevated concentration in seminal plasma and act as a biomarker of different carcinomas as their levels are also enhanced in serum and are found to be involved in tumor progression and metastasis apart from fertility. The proteins which were overexpressed in the seminal plasma of prostate carcinoma patients were identified by 2-DE and MALDI-TOF/MS. We have designed a strategy to purify these four proteins prostate specific antigen (PSA), prostatic acid phosphatase (PAP), Zinc alpha2-glycoprotein (ZAG), and progastricsin (PG), together in homogeneity by using simple chromatographic techniques. Acidic and basic fractions of human seminal plasma were separated by ion exchange chromatography and further purified by gel permeation chromatography. Our results form a new and valuable resource for those attempting structure-based drug designing for prostate and other cancers where the amount of proteins is required in plenty and in native form.  相似文献   

6.
A simple, specific and sensitive Radioimmunoassay (RIA) has been developed for the measurement of Human Growth Hormone (HGH) in serum samples.125I-labelled HGH has been used as a tracer and dextran coated charcoal system employed to separate antibody bound hormone from the unbound one. The assay offers sensitivity of 0.16 ng/ml with a reproductibility of 7% intrassay and inter-assay variations. Serum HGH levels were measured at fasting-resting state and during insulin stimulation test in (1) 15 normal subjects (controls and (2) 31 patients with stunted growth, whereas (3) in 7 acromegalic patients the same were measured at fasting-resting state and after oral glucose administration. This procedure has been used to distinguish dwarfs due to growth hormone deficiency from other conditions unrelated to pituitary disease and to confirm acromegaly.  相似文献   

7.
Standard cotinine solutions, controls and human serum samples containing cotinine have been measured by both radioimmunoassay (RIA) and gas chromatographic (GC) techniques. Cross-checks on standards and controls showed good agreement. However, for samples containing greater than 50 ng ml-1 of cotinine, RIA gave results on average 60% higher than GC. Determinations by using RIA and GC on samples containing less than 7 ng ml-1 of cotinine gave no significant correlation. The importance of the age of the serum sample has been investigated, and it is suggested that the age may affect the determination when dealing with low levels of cotinine.  相似文献   

8.
《Analytical letters》2012,45(8):1377-1388
Abstract

4-[(5,6,7,8-Tetrahydro-5,5,8,8-tetramethyl-2-naphthyl)-carbamoyl] benzoic acid (Am-80) is a novel retinobenzoic acid derivative possessing retinoid activity. Plasma concentration of this drug in clinical use is very low, less than 1 ng/ml, and could not be measured with direct immunoassays. A combination of high-performance liquid chromatography (HPLC) and radioimmunoassay (RIA) was developed for this drug in human plasma. Am-80 in 0.5 ml of human plasma was extracted by solid-phase extraction, and the extract was purified by reversed-phase HPLC. The immunoreactivity in the fraction of the eluate was measured by competitive RIA. The within- and between-assay variances were 4.1 to 15.5% and 4.1 to 7.0%, respectively. The limit of quantification was 0.04 ng/ml in human plasma, which was much lower than that of direct RIA, 0.6 ng/ml, previously reported. This assay system could be used to observe the pharmacokinetics of Am-80 in human even after dermal application at very low dose.  相似文献   

9.
The mass fragmentographic determination of medroxyprogesterone acetate (MPA) in serum, using as internal standard medroxyprogesterone propionate (MPP) synthesized from MPA, is described. After addition of MPP, the sera are extracted on Sep-Pak C18 cartridges and MPA and MPP are detected as their respective 3-enol trifluoroacyl esters. Serum samples from 84 patients with breast cancer, daily receiving MPA orally, were determined showing a large variation in MPA concentrations (4-349 ng/ml). Our proposed gas chromatographic-mass spectrometric (GC-MS) method, which can be considered as a reference, was compared with a radioimmunoassay (RIA) method showing a correlation coefficient of 0.73 (n = 69; p much less than 0.001). The assay was also used to determine sequential serum levels of patients receiving a single oral dose of MPA. With only minor adjustments, the GC-MS method allows the determination of serum concentrations of related steroids such as megestrol acetate and cyproterone acetate.  相似文献   

10.
Microdrop analysis of a bead-based immunoassay   总被引:1,自引:0,他引:1  
The progress to electrochemical detection of a microbead-based immunoassay in small volumes has led to a reduced assay time and lower detection limits. Three electrochemical techniques are described for an immunoassay with detection in a microdrop. The techniques are amperometric detection with a rotating disk electrode (RDE), a microelectrode, and an interdigitated array (IDA) electrode. An enzyme-labeled sandwich immunoassay with mouse IgG as the model analyte is used to demonstrate the three techniques. The microbead assay is carried out in a test tube using a magnet to control bead collection. Once the immunocomplex is formed on the microbead, the beads are transferred to a microdrop where the enzyme, either alkaline phosphatase or β-galactosidase, generates 4-aminophenol (PAP). PAP is oxidized at the electrode with an applied potential of +290 mV vs. Ag/AgCl. For all three techniques, the upper limit of the dynamic range was 1000 ng/ml mouse IgG, and the detection limits were: 50 ng/ml for the RDE, 40 ng/ml for the microelectrode, and 26 ng/ml for the IDA electrode.  相似文献   

11.
In this article, postsplenectomy changes of serum tuftsin level were studied on both human subjects and rabbits by using a self-established radioimmunoassay protocol. Antituftsin antibodies were raised in rabbits and roosters.125I-tuftsin was prepared through an Iodogen method. The characteristics of the RIA were satisfactory with a detecting range of 0.5–100 ug/ml and the lowest detection limit of 400ng/ml. Serum tuftsin levels of splenectomized subjects were measured and compared with control groups. The serum tuftsin level from 30 postsplenectomy human beings was 406±179 ng/ml ( ± s) while that from a control group of 40 healthy blood donors was 557±256 ng/ml; the serum tuftsin level of 10 postsplenectomy rabbits was found to be 206±75 ng/ml while that of a control group of 10 normal rabbits was 318±96 ng/ml. The results showed that serum tuftsin level decreased markedly after splenectomy.  相似文献   

12.
《Analytical letters》2012,45(5):757-766
Abstract

A high‐performance liquid chromatography (HPLC) method has been developed for the determination of ochratoxin A (OTA) in human blood serum. Samples were purified on a C18 solid phase extraction column. The developed method required a relatively low serum volume (0.5 ml). Significant correlation (r of 0.998) was found over the range from 0.10 to 8 ng/ml, with a detection limit of 0.1 ng/ml and better performance in terms of precision and accuracy. Mean recoveries at 0.5 and 2 ng/ml were respectively 69.7±1.2 and 71.9±2.8%. This method was used as a rapid and noninvasive tool to assess human exposure to OTA. Among 40 analyzed serum samples, 27.5% were found to contain OTA with levels going from 0.1 to 11.98 ng/ml with a mean concentration of 0.73±2.35 ng/ml.  相似文献   

13.
Truncated Epstein-Barr virus (EBV) membrane antigen gp350/220 (EBV-MA) lacking the membrane anchor was expressed and secreted into the medium of recombinant Chinese hamster ovary cells that had been cultured in Plasmapur hollow-fibre modules using defined serum-free medium. The EBV-MA in the medium was concentrated by 70% (w/v) ammonium sulphate precipitation and subsequently purified by immunoaffinity chromatography using an anti-EBV-MA (EBV.0T6) monoclonal antibody (mAb) column. Adsorbed antigen was eluted with 3 M MgCl2 in phosphate-buffered saline, concentrated by Mono Q anion-exchange chromatography and analysed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis, silver staining and Western blotting using EBV-positive serum and anti-EBV-MA specific mAbs. Monospecific polyclonal rabbit antibodies against the purified EBV-MA were raised and purified by protein G affinity chromatography. For the measurement of EBV-MA antigen levels a sandwich enzyme-linked immunosorbent assay using rabbit polyclonal antibodies and a horseradish peroxidase-conjugated anti-MA mAb was developed having a detection level of 10 ng/ml.  相似文献   

14.
15.
Diagnosis of prostate cancer (PCa) is currently much reliant on the invasive and time-consuming transrectal ultrasound-guided biopsy of the prostate gland, particularly in light of the inefficient use of prostate-specific antigen as its biomarker. In the present study, we have profiled the sera of patients with PCa and benign prostatic hyperplasia (BPH) using the gel- and lectin-based proteomics methods and demonstrated the significant differential expression of apolipoprotein AII, complement C3 beta chain fragment, inter-alpha-trypsin inhibitor heavy chain 4 fragment, transthyretin, alpha-1-antitrypsin, and high molecular weight kininogen (light chain) between the two groups of patients' samples. Our data are suggestive of the potential use of the serum proteins as complementary biomarkers to effectively discriminate PCa from BPH, although this requires further extensive validation on clinically representative populations.  相似文献   

16.
《Analytical letters》2012,45(6):1017-1037
Abstract

We established an enzyme-linked immunosorbent assay (ELISA) to quantify human IgG subclasses in serum. IgG subclasses captured with subclass-specific mouse MoAbs could be detected with enzyme-labeled goat anti-human IgG. We screened the MoAbs which were suitable for the method from the commercially available MoAbs raised against human IgG subclasses. The specificity of the present ELISA for each subclass was clarified by the experiments as follows: (a) identification of individual IgG subclasses purified from total IgG by protein A column chromatography and (b) identification of a certain specific subclass which increased relatively in monoclonal (M)-proteinemia-patient sera compared with normal. We could detect each subclass with the sensitivity of 4.0 ng/ml for IgG1, 13 ng/ml for IgG2, 0.5 ng/ml for IgG3 and 0.4 ng/ml for IgG4 using pooled normal serum calibrated against a reference serum 67/86 from the World Health Organization (WHO) as a standard.  相似文献   

17.
Digoxin is widely used as a cardiac glycoside drug in the treatment of various heart conditions. Because it is a toxic drug, it should be regularly monitored in the serum of patients under treatment. In this study, colloidal nanogold is synthesized and the preparation of nanogold-labeled monoclonal antibody probe to digoxin is described under optimal conditions. In addition, an immunochromatographic (IC) method for digoxin analysis employing nanogold-labeled probe is developed. With this technique, it requires only 5 min to complete the quantitative detection of digoxin. The detection time is decreased 20–30 times in comparison to radioimmunoassay (RIA). The sensitivity to digoxin was about 2 ng/ml by naked eye, which is within the therapeutic and toxic ranges of digoxin. The results of serum samples obtained by IC strip were in agreement with those obtained by RIA. The IC strip was sufficiently sensitive and accurate to be used for the rapid detection of digoxin in serum samples.  相似文献   

18.
A radioimmunoanalytical (RIA) method was elaborated for the determination of ferritin in human blood serum in clinical practice. Placental ferritin separated from the human after-delivery placental and antibodies against the human placental ferritin obtained by the immunization of rabbits with this antigen were used. The whole complex of basic conditions and parameters of the RIA method was tested including the estimation of the region of normal values and clinical tests. The method elaborated was compared with the commercial kit Ferritin RIA Amersham, code IM 1051, chosen as reference kit. The results of the determination of control parameters as well as ferritin levels obtained by the method elaborated exert good agreement with the reference kit and correspond to requirements for routine RIA practice.  相似文献   

19.
A method using reversed-phase high-performance liquid chromatography with ultraviolet detection for the determination of ceterizine in serum is described. The method is sensitive down to 50 ng/ml (250-microliter loop). Sample preparation involves only serum deproteination with perchloric acid and injection of the centrifuged supernatant. Elution is at pH 2.5 with acetonitrile-methanol-0.05 M phosphate buffer (33:9:58, v/v) on a 25 cm x 4.6 mm I.D. Spherisorb S5 ODS2 column. Detection is at 211 nm, its lambda max. For levels above 300 ng/ml the serum sample size is 100 microliter and a 200-microliter sample is necessary for concentrations less than 300 ng/ml. At the 2 micrograms/ml concentration the intra-assay relative standard deviation is better than 2.2%, whilst the inter-assay deviation is 2.6% over eight samples. At 200 ng/ml the intra-assay relative standard deviation is 6% over seven samples. Detector response is linear from 100 ng/ml to 10 micrograms/ml (100-microliter loop).  相似文献   

20.
Prostate specific antigen (PSA) is a protease which is characteristic of the prostate. It is widely used as a serum marker for the early diagnosis of prostate cancer (PCa). Nevertheless, for concentrations between 4 and 10 ng/mL, PSA does not enable PCa to be distinguished from benign diseases, such as benign prostate hyperplasia (BPH). In sera, the use of a ratio between free PSA (PSA uncomplexed with protease inhibitor) and total PSA (free PSA and PSA bound to alpha-1 anti-chymotrypsin) enables the "gray zone" to be reduced, but an important proportion of patients are still wrongly classed. Using two-dimensional electrophoresis, we demonstrated using 52 PCa and 40 BPH well-documented clinical cases that BPH sera show a significantly greater percentage of low-molecular-weight free PSA elements (IwPSA) than PCa sera. In our study, the use of a ratio between IwPSA and standard free PSA enables the correct diagnosis of 100% of PCa and 82.5% of BPH cases as against when 73.1% and 42.5% respectively were correctly diagnozed using the total PSA and the free/total PSA ratio. This important finding may be related to differences in the mechanism secreting PSA from the prostate into the bloodstream. We have shown how a tissue marker may be turned into a powerful tumor marker by events probably unrelated to its expression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号