首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
On-line supported liquid membrane (SLM) extraction and microporous membrane liquid-liquid extraction (MMLLE) techniques for sample preparation of natural water samples have been developed for the determination of thiophanate-methyl (TM), carbendazim (MBC) and 2-aminobenzimidazole (2-AB) using reversed-phase HPLC. The combination of SLM extraction and MMLLE offers extraction conditions that makes it possible to determine a wide variety of compounds, i.e., permanently charged, ionisable and non-polar at sub ppb level. The detection limits obtained after extraction are about 0.1 microg/l for MBC and 2-AB using SLM, and 0.5 x Lg/l for TM using MMLLE and the precision is better than 5% for both systems. Typical enrichment rates are 0.6 and 2.7 times/min using SLM and MMLLE, respectively.  相似文献   

2.
Combining the continuous flow liquid-liquid extraction (CFLLE) and supported liquid membrane (SLM) extraction, a novel aqueous-aqueous extraction technique that we termed continuous flow liquid membrane extraction (CFLME) is developed for trace-enrichment. The analyte was firstly extracted into the organic phase in the CFLLE step, then transported onto the organic liquid membrane that formed on the surface of the micro porous membrane of the SLM equipment. Finally, it passed through the liquid membrane and was trapped by the acceptor. Aspects related to CFLME were studied by using dichloromethane as liquid membrane, and sulfonylurea herbicides as model compounds. An enrichment factor of over 1000 was obtained when 10 μg l−1 of MSM was enriched for 120 min by this technique. The drawbacks of only a few organic solvents can be selected as liquid membrane with a limited lifetime in SLM operation was overcome. In this CFLME method, almost all solvents that used in the conventional liquid-liquid extraction (LLE) can be adopted and the lifetime of liquid membrane is no longer a problem.  相似文献   

3.
Electromembrane extraction (EME) of polar basic drugs from human plasma was investigated for the first time using pure bis(2-ethylhexyl) phosphite (DEHPi) as the supported liquid membrane (SLM). The polar basic drugs metaraminol, benzamidine, sotalol, phenylpropanolamine, ephedrine, and trimethoprim were selected as model analytes, and were extracted from 300 μL of human plasma, through 10 μL of DEHPi as SLM, and into 100 μL of 10 mM formic acid as acceptor solution. The extraction potential across the SLM was 100 V, and extractions were performed for 20 min. After EME, the acceptor solutions were analyzed by high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In contrast to other SLMs reported for polar basic drugs in the literature, the SLM of DEHPi was highly stable in contact with plasma, and the system-current across the SLM was easily kept below 50 μA. Thus, electrolysis in the sample and acceptor solution was kept at an acceptable level with no detrimental consequences. For the polar model analytes, representing a log P range from −0.40 to 1.32, recoveries in the range 25–91% were obtained from human plasma. Strong hydrogen bonding and dipole interactions were probably responsible for efficient transfer of the model analytes into the SLM, and this is the first report on efficient EME of highly polar analytes without using any ionic carrier in the SLM.  相似文献   

4.
A large screening of different components in the supported liquid membrane (SLM) in electromembrane extraction (EME) was performed to test the extraction efficiency on eight model peptides. Electromembrane extraction from a 500 μL acidified aqueous sample containing the model peptides in the concentration 10 μg/mL was used. Extraction time was 5 min with an electric potential of 10 V and 900 rpm agitation of the sample vial. The samples were extracted through a hollow fiber-based SLM with different compositions of organic solvents and carriers. A small volume of acidified acceptor solution (25 μL) was after extraction analyzed directly, or with some dilution, on CE or HPLC. This article has identified mono- or di-substituted phosphate groups as the prominent group of carrier molecules needed to obtain acceptable recoveries. For the organic solvents, primary alcohols and ketones have shown promise regarding recovery and reproducibility, with some differences in selectivity. A new composition of the SLM, namely 2-octanone and tridecyl phosphate (90:10 w/w) has proved to give higher extraction recoveries and lower standard deviation than SLMs previously reported in the literature.  相似文献   

5.
Electromembrane extraction (EME) of basic drugs from 10 μL sample volumes was performed through an organic solvent (2-nitrophenyl octyl ether) immobilized as a supported liquid membrane (SLM) in the pores of a flat polypropylene membrane (25 μm thickness), and into 10 μL 10 mM HCl as the acceptor solution. The driving force for the extractions was 3–20 V d.c. potential sustained over the SLM. The influence of the membrane thickness, extraction time, and voltage was investigated, and a theory for the extraction kinetics is proposed. Pethidine, nortriptyline, methadone, haloperidol, and loperamide were extracted from pure water samples with recoveries ranging between 33% and 47% after only 5 min of operation under totally stagnant conditions. The extraction system was compatible with human urine and plasma samples and provided very efficient sample pretreatment, as acidic, neutral, and polar substances with no distribution into the organic SLM were not extracted across the membrane. Evaluation was performed for human urine, providing linearity in the range 1–20 μg/mL, and repeatability (RSD) in average within 12%.  相似文献   

6.
Thirty-five different basic drugs were extracted by electro membrane extraction (EME), from acidified samples containing HCl as the BGE, through an organic solvent immobilized in the pores in the wall of a porous hollow fiber (supported liquid membrane, SLM), and into an acidified acceptor solution (HCl) in the lumen of the hollow fiber by the application of an electrical potential difference of 50 V. With 2-nitrophenyl pentyl ether (NPPE) as the SLM, and with 10 mM HCl as BGE in the sample and acceptor solution, singly charged basic drugs with log P >2 were extracted with recoveries in the range 30-81% within 5 min. For doubly charged basic drugs, extraction was effectively enhanced by decreasing the concentration of HCl in the sample from 10 to 0.1 mM, reducing the ionization of the analytes. For medium polar analytes (1 < log P < 2), an ion balance of 0.01 was combined with addition of tris-(2-ethylhexyl) phosphate (TEHP) to the SLM, and this provided recoveries in the range 36-70%. The ion balance was defined as the concentration ratio of BGE between the sample and the acceptor solution. For the most polar drugs (log P <1), EME was accomplished with an ion balance of 0.01 and with di-(2-ethylhexyl) phosphate (DEHP) added to the SLM, but in spite of this, recoveries were in the range of only 4-17%.  相似文献   

7.
Electromembrane extraction (EME) of model analytes was carried out using a virtually rotating supported liquid membrane (SLM). The virtual (nonmechanical) rotating of the SLM was achieved using a novel electrode assembly including a central electrode immersed inside the lumen of the SLM and five counter electrodes surrounding the SLM. A particular electronic circuit was designed to distribute the potential among five counter electrodes in a rotating pattern. The effect of the experimental parameters on the recovery of the extraction was investigated for verapamil (VPL), trimipramine (TRP), and clomipramine (CLP) as the model analytes and 2‐ethyl hexanol as the SLM solvent. The results showed that the recovery of the extraction is a function of the angular velocity of the virtual rotation. The best results were obtained at an angular velocity of 1.83 RadS?1 (or a rotation frequency of 0.29 Hz).The optimization of the parameters gave higher recoveries up to 50% greater than those of a conventional EME method. The rotating also allowed the extraction to be carried out at shorter time (15 min) and lower voltage (200 V) with respect to the conventional extraction. The model analytes were successfully extracted from wastewater and human urine samples with recoveries ranging from 38 to 85%. The RSD of the determinations was in the range of 12.6 to 14.8%.  相似文献   

8.
Msagati TA  Nindi MM 《Talanta》2006,69(1):243-250
Supported liquid membrane (SLM) and solid phase extraction (SPE) have been applied as clean-up and/or enrichment techniques for a mixture of five benzimidazole anthelmintics compounds, namely albendazole, fenbendazole, mebendazole, oxibendazole, and thiabendazole. Two biological matrices, mainly urine and milk, and ultra high purity (UHP) water were spiked with a mixture of these five compounds. Waters Oasis® MCX and International Sorbent Technology (IST) HCX SPE sorbents were used. The liquid membrane used for clean-up and/or enrichment of these compounds was 5% tri-n-octylphosphine oxide (TOPO) dissolved in n-undecane/di-n-hexyl ether (1:1). The SLM extraction efficiencies and SPE percentage recoveries ranged between 60 and 100%. The detection limits (DLs) for different benzimidazole compounds by SPE/LC-ES-MS for thiabendazole, oxibendazole, and albendazole was 0.1 ng/L, for fenbendazole and mebendazole was 1 and 10 ng/L, respectively. Similarly, the detection limits of SLM/LC-ES-MS for thiabendazole, oxibendazole, and albendazole was 0.1 ng/L and for fenbendazole and mebendazole was 1 ng/L. The results of optimization of various parameters of the SLM method are reported.  相似文献   

9.
Pressurised hot water extraction-microporous membrane liquid-liquid extraction was coupled on-line with gas chromatography-mass spectrometry (PHWE-MMLLE-GC-MS) for the analysis of pesticides in grapes. MMLLE serves as a trapping step after PHWE. Water from PHWE is directed to the donor side of the membrane unit and the analytes are extracted to the acceptor solution on the other side. The role of MMLLE is to clean and concentrate the extract before on-line transfer to the GC via a sample loop and an on-column interface using partially concurrent solvent evaporation. The extraction conditions were investigated, and then the quantitative features such as linearity, limit of quantification (LOQ), extraction yield and enrichment factors. LOQs in the range 0.3-1.8 microg kg(-1) were achieved. Procymidone and tetradifon were found in the skins of the grapes. The results were in good agreement with those obtained by liquid-solid and ultrasonic extractions.  相似文献   

10.
This paper proposes a novel strategy to enhance selectivity and sensitivity in CE, using supported liquid membrane (SLM) and off-line SPE simultaneously. The determination of ochratoxin A (OA) in wine has been used to demonstrate the potential of this methodology. In the SLM step, the donor phase (either a 20 mL volume of a standard solution at pH 1 or a wine sample at pH 8) was placed in a vial, where a micromembrane extraction unit accommodating the acceptor phase (1 mL water, pH 11) in its lumen was immersed. The SLM was constructed by impregnating a porous Fluoropore Teflon (PTFE) membrane with a water-immiscible organic solvent (octanol). In the off-line SPE step, the nonpolar sorbent (C-18, 4 mg) selectively retained the target ochratoxin, enabling small volumes of acceptor phase (1 mL) to be introduced. The captured analytes were eluted in a small volume of methanol (0.1 mL). This procedure resulted in sample cleanup and concentration enhancement. The method was evaluated for accuracy and precision, and its RSD found to be 5%. The LODs for OA in the standard solutions and wine samples were 0.5 and 30 microg/L, respectively. The results obtained demonstrate that SLM combined with off-line is a good alternative to the use of immunoaffinity columns prior to CE analysis.  相似文献   

11.
Mulugeta M  Megersa N 《Talanta》2004,64(1):101-108
Supported liquid membrane (SLM) method for preconcentration and enrichment of the two bipyridilium herbicides, namely diquat and paraquat, from environmental water samples has been developed. The permanently charged cationic herbicides were extracted from a flowing aqueous solution to a stagnant acidic acceptor solution across a liquid membrane containing 40% (v/v) di-(2-ethylhexyl) phosphoric acid dissolved in di-n-hexyl ether. The mass transfer of analytes is driven by the counter-coupled transport of hydrogen ions from the acceptor to the donor phase. The efficiency of the extraction process depends on the donor solution pH, the amount of the mobile carrier added to the liquid membrane and the concentration of the counter ion in the acceptor solution. The applicability of the method for extraction of these quaternary ammonium herbicides from environmental waters was also investigated by spiking analyte sample solutions in river water. With 24 h sample enrichment concentrations of diquat and paraquat down to ca. 10 ng/L could be detected in environmental waters.  相似文献   

12.
An electro membrane extraction (EME) methodology was utilized to study the isolation of some environmentally important pollutants, such as chlorophenols, from aquatic media based upon the electrokinetic migration process. The analytes were transported by application of an electrical potential difference over a supported liquid membrane (SLM). A driving force of 10 V was applied to extract the analytes through 1-octanol, used as the SLM, into a strongly alkaline solution. The alkaline acceptor solution was subsequently analyzed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The parameters influencing electromigration, including volumes and pH of the donor and acceptor phases, the organic solvent used as the SLM, and the applied voltage and its duration, were investigated to find the most suitable extraction conditions. Since the developed method showed a rather high degree of selectivity towards pentachlorophenol (PCP), validation of the method was performed using this compound. An enrichment factor of 23 along with acceptable sample clean-up was obtained for PCP. The calibration curve showed linearity in the range of 0.5–1000 ng/mL with a coefficient of estimation corresponding to 0.999. Limits of detection and quantification, based on signal-to-noise ratios of 3 and 10, were 0.1 and 0.4 ng/mL, respectively. The relative standard deviation of the analysis at a PCP concentration of 0.5 ng/mL was found to be 6.8% (n = 6). The method was also applied to the extraction of this contaminant from seawater and an acceptable relative recovery of 74% was achieved at a concentration level of 1.0 ng/mL.  相似文献   

13.
Msagati TA  Nindi MM 《Talanta》2004,64(1):87-100
A high performance liquid chromatography (HPLC) coupled to a mass spectrometer (MS) was used for a simultaneous determination of 16 sulfonamide compounds spiked in water, urine, milk, and bovine liver and kidney tissues. Supported liquid membrane (SLM) made up of 5% tri-n-octylphosphine oxide (TOPO) dissolved in hexyl amine was used as a sample clean-up and/or enrichment technique. The sulfonamides mixture was made up of 5-sulfaminouracil, sulfaguanidine, sulfamethoxazole, sulfamerazine, sulfamethizole, sulfamethazine (sulfadimidine), sulfacetamide, sulfapyridine, sulfabenzamide, sulfamethoxypyridazine, sulfamonomethoxine, sulfadimethoxine sulfasalazine, sulfaquinoxaline, sulfadiazine, and sulfathiazole. Some of these compounds, such as, sulfaquinoxaline, sulfadiazine, sulfabenzamide, sulfathiazole and sulfapyridine failed to be trapped efficiently by the same liquid membrane (5% TOPO in hexylamine). The detection limits (DL) obtained were 1.8 ppb for sulfaguanidine and sulfamerazine and between 3.3 and 10 ppb in bovine liver and kidney tissues for the other sulfonamides that were successfully enriched with SLM; 2.1 ppb for sulfaguanidine and sulfamerazine and between 7.5 and 15 ppb in cow’s urine, whereas the DL values in milk were 12.4 ppb for sulfaguanidine and sulfamerazine and between 16.8 and 24.3 for the other compounds that were successfully enriched by the membrane. Several factors affecting the extraction efficiency during SLM enrichment, such as donor pH, acceptor pH, enrichment time and the membrane solvent were studied.  相似文献   

14.
This fundamental work illustrates for the first time the possibility of exhaustive extraction of peptides using electromembrane extraction (EME) under low system-current conditions (<50 μA). Bradykinin acetate, angiotensin II antipeptide, angiotensin II acetate, neurotensin, angiotensin I trifluoroacetate, and leu-enkephalin were extracted from 600 μL of 25 mM phosphate buffer (pH 3.5), through a supported liquid membrane (SLM) containing di-(2-ethylhexyl)-phosphate (DEHP) dissolved in an organic solvent, and into 600 μL of an acidified aqueous acceptor solution using a thin flat membrane-based EME device. Mass transfer of peptides across the SLM was enhanced by complex formation with the negatively charged DEHP. The composition of the SLM and the extraction voltage were important factors influencing recoveries and current with the EME system. 1-nonanol diluted with 2-decanone (1:1 v/v) containing 15% (v/v) DEHP was selected as a suitable SLM for exhaustive extraction of peptides under low system-current conditions. Interestingly, increasing the SLM volume from 5 to 10 μL was found to be beneficial for stable and efficient EME. The pH of the sample strongly affected the EME process, and pH 3.5 was found to be optimal. The EME efficiency was also dependent on the acceptor solution composition, and the extraction time was found to be an important element for exhaustive extraction. When EME was carried out for 25 min with an extraction voltage of 15 V, the system-current across the SLM was less than 50 μA, and extraction recoveries for the model peptides were in the range of 77–94%, with RSD values less than 10%.  相似文献   

15.
A supported liquid membrane (SLM) technique was investigated to extract and preconcentrate Mn(II) from water, milk and blood serum. Di-2-ethylhexyl phosphoric acid (DEHPA) with kerosene as diluent was used as a carrier in the membrane to transport Mn(II) from the donor side to acceptor side. The membrane was modified with tri-n-octylphosphine oxide (TOPO) to increase its polarity. Various parameters were investigated to optimise the extraction efficiency: pH of the donor and acceptor phase, dilution factor, donor flow rate. Scanning electron microscope images of the membranes revealed that some matrix compounds were deposited on the surface, thus limiting the extraction process. The optimum conditions found were: pH 3 in the donor phase, 0.2 M nitric acid in the acceptor phase, donor flow rate between 1.0 and 0.3 ml min−1, 15% (w/v) DEPHA and 10% TOPO in kerosene as a carrier in membrane, and dilution factors of 20 times for blood serum and 30 times for milk. The extraction efficiencies were found to be low but constant and highly reproducible showing, strong dependence on sample matrix. The new SLM extraction probe was developed and optimised for Mn(II) extraction. Compared to traditional SLM configurations, this is the simplest configuration. The use of stirring allows the same sample to be extracted many times giving higher extraction efficiency and to minimise the sample size. Adsorptive stripping voltammetry (AdSV) was applied to measure Mn(II) concentration. The optimised method was used to determine the concentration of Mn(II) in water, milk and blood serum samples.  相似文献   

16.
The present work has for the first time described nano-electromembrane extraction (nano-EME). In nano-EME, five basic drugs substances were extracted as model analytes from 200 μL acidified sample solution, through a supported liquid membrane (SLM) of 2-nitrophenyl octyl ether (NPOE), and into approximately 8 nL phosphate buffer (pH 2.7) as acceptor phase. The driving force for the extraction was an electrical potential sustained over the SLM. The acceptor phase was located inside a fused silica capillary, and this capillary was also used for the final analysis of the acceptor phase by capillary electrophoresis (CE). In that way the sample preparation performed by nano-EME was coupled directly with a CE separation. Separation performance of 42,000–193,000 theoretical plates could easily be obtained by this direct sample preparation and injection technique that both provided enrichment as well as extraction selectivity. Compared with conventional EME, the acceptor phase volume in nano-EME was down-scaled by a factor of more than 1000. This resulted in a very high enrichment capacity. With loperamide as an example, an enrichment factor exceeding 500 was obtained in only 5 min of extraction. This corresponded to 100-times enrichment per minute of nano-EME. Nano-EME was found to be a very soft extraction technique, and about 99.2–99.9% of the analytes remained in the sample volume of 200 μL. The SLM could be reused for more than 200 nano-EME extractions, and memory effects in the membrane were avoided by effective electro-assisted cleaning, where the electrical potential was actively used to clean the membrane.  相似文献   

17.
Pressurised hot water extraction (PHWE) was coupled on-line via hollow fibre microporous membrane liquid-liquid extraction (HF-MMLLE) to gas chromatography (GC) and applied in the analysis of polycyclic aromatic hydrocarbons (PAHs) in soil and sediment. In this combination, the MMLLE unit serves as a trapping device for the extracted compounds. Simultaneously it cleans and concentrates the extract, which is then transferred on-line to the GC. No extra clean-up steps are required between the trapping and the transfer to GC. The on-line system gives excellent sensitivity while allowing small sample size. The method was linear, with limits of detection in the range 50-890 pg and limits of quantification 0.11-1.22 microg g(-1). The concentration enrichment factors obtained with the method ranged from 9 to 55. Comparison of the results with those obtained by other techniques confirmed the good performance.  相似文献   

18.
Planar polyamide 6 nanofibrous membrane was for the first time used in direct coupling of supported liquid membrane (SLM) extraction to CE analysis. Disposable microextraction device with the nanofibrous membrane was preassembled and stored for immediate use. The membrane in the device was impregnated with 1 µL of 1‐ethyl‐2‐nitrobenzene and the device was subsequently filled with 10 µL of acceptor solution (10 mM HCl) and 15 µL of donor solution (sample). The device was in‐line coupled to CE system for selective extraction and direct injection, separation and quantification of model basic drugs (nortriptyline, haloperidol, loperamide and papaverine) from standard saline solutions (150 mM NaCl) and from undiluted human body fluids (urine and blood plasma). Compared to standard polypropylene supporting material, the nanofibrous membrane demonstrated superior characteristics in terms of lower consumption of organic solvents, constant volumes of operational solutions, full transparency and possibility to preassemble the devices. Extraction parameters were better or comparable for the nanofibrous vs. the polypropylene membrane and the hyphenated SLM‐CE method with the nanofibrous membrane was characterized by good repeatability (RSD ≤ 11.3%), linearity (r2 ≥ 0.9953; 0.5–20 mg/L), sensitivity (LOD ≤ 0.4 mg/L) and transfer (27–126%) of the basic drugs.  相似文献   

19.
In the present work, a new supported liquid membrane (SLM) has been developed for on‐chip electromembrane extraction of acidic drugs combined with HPLC or CE, providing significantly higher stability than those reported up to date. The target analytes are five widely used non‐steroidal anti‐inflammatory drugs (NSAIDs): ibuprofen (IBU), diclofenac (DIC), naproxen (NAX), ketoprofen (KTP) and salicylic acid (SAL). Two different microchip devices were used, both consisted basically of two poly(methyl methacrylate) (PMMA) plates with individual channels for acceptor and sample solutions, respectively, and a 25 µm thick porous polypropylene membrane impregnated with the organic solvent in between. The SLM consisting of a mixture of 1‐undecanol and 2‐nitrophenyl octyl ether (NPOE) in a ratio 1:3 was found to be the most suitable liquid membrane for the extraction of these acidic drugs under dynamic conditions. It showed a long‐term stability of at least 8 hours, a low system current around 20 µA, and recoveries over 94% for the target analytes. NPOE was included in the SLM to significantly decrease the extraction current compared to pure 1‐undecanol, while the extraction properties was almost unaffected. Moreover, it has been successfully applied to the determination of the target analytes in human urine samples, providing high extraction efficiency.  相似文献   

20.
In the present study, electro membrane isolation (EMI) of four nerve agent degradation products has been successfully explored. In the procedure, a polypropylene sheet membrane folded into an envelope with an open end with its wall pores impregnated with 1-octanol was employed as the artificial supported liquid membrane (SLM). The envelope containing the extractant or aqueous acceptor phase (at pH 6.8) was immersed in the sample or donor phase (also aqueous at a pH of 6.8) for extraction. This ensured that the target analytes were fully ionized. A voltage was then applied, with the negative electrode placed in the donor phase with agitation, and the positive electrode in the acceptor phase. The ionized analytes were thus driven to migrate from the donor phase across the SLM to the acceptor phase. The factors influential to extraction: type of organic solvent, voltage, agitation speed, extraction time, pH of the donor and acceptor phase and concentration of humic acids were investigated in detail. After extraction, the acceptor phase was collected and directly injected for capillary electrophoretic (CE) analysis. Combined with capacitively coupled contactless conductivity detection (C(4)D), the direct detection of these compounds could be achieved. Moreover, large-volume sample injection was employed to further enhance the sensitivity of this method. Limits of detection (LODs) as low as ng/mL were reached for the studied analytes, with overall LOD enhancements of four orders of magnitude.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号