首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
The theory and proof of concept of a new mode of operation for comprehensive two-dimensional gas chromatography (GC x GC) is presented. In current GC x GC interface designs, the modulation period defines the separation time allowed in the second dimension. In the stop-flow GC x GC mode, flow in the primary column is periodically stopped for brief periods of time. Consequently, the modulation period for the primary column and the amount of time available for second dimension separation become independent variables. This allows the separations in both the primary and secondary dimensions of the GC x GC system to be carried out under more optimised conditions, allowing extended periods of time for second dimension separations without sacrificing the separation in the primary dimension. This new technique has the potential to offer increased separation power and overall resolution as it is further developed.  相似文献   

2.
Soft laser photo-ionization mass spectrometry is presented as a separation dimension hyphenated with gas chromatographic techniques. Single photon ionization (SPI) is a universal soft ionization method which ionizes organic molecules with an ionization potential below 10.5 eV if 118 nm laser radiation is used. The inherently soft ionization of photo ionization techniques can further be utilized together with gas chromatography as a comprehensive two-dimensional separation method (GC x MS), using the GC retention time as first separation dimension and the molecular mass as second separation dimension. Some GC x MS chromatograms of diesel petroleum samples using SPI are presented and discussed. Finally, it is demonstrated that the coupling of soft SPI mass spectrometry with comprehensive two-dimensional gas chromatography (GC x GC) provides a three-dimensional separation technique (GC x GC x SPI-MS).  相似文献   

3.
Comprehensive two-dimensional gas chromatography (GC x GC) analysis has the capability to resolve many more components of complex mixtures than traditional single column GC analysis. There is an increasing need to provide reliable identification of these separated components; time-of-flight mass spectrometry (TOFMS) is the most appropriate technology to achieve this task. Rather than require MS for all GC x GC separations, it is desirable to assign peak identities to specific peak positions in the GC x GC separation space, and this necessitates matching peak retentions in the two experiments - GC x GC-FID and GC x GC-TOFMS. The atmospheric vs. vacuum outlet conditions confound this task. It is shown here that by employing a supplementary gas supply, provided to a T-union between the column outlet and the MS interface, it is possible to generate 2D chromatograms for GC x GC-FID and GC x GC-TOFMS that are essentially exactly matched. There is no degradation in separation performance or efficiency in the second column in the system interfaced to the T-union. Since the GC x GC-FID experiment uses hydrogen for maximum efficiency, and GC x GC-TOFMS uses helium carrier, translation of (conditions/retentions) must account for the different viscosities of the carrier gases. Translation of conditions is based on well-known principles established in single column analysis. Tabulated data illustrate that retention reproducibility was of the order of better than 4 s for the average first dimension retention difference, and about 40 ms for the average second dimension retention difference when comparing GC x GC-FID and GC x GC-TOFMS results. This should provide considerable support for identification in routine GC x GC-FID analysis of specific sample types, once the peaks in 2D separation space have been assigned identities through GC x GC-TOFMS analysis.  相似文献   

4.
During each sampling period, an accumulating resampler (modulator) in comprehensive 2-D chromatography accumulates all eluite from the first-dimension column and reinjects the whole or a portion of the accumulated material into the second-dimension column. The detrimental effect of the resampling on peak capacity of a 2-D separation comes from the broadening of the peaks along the first-dimension due to the resampling itself and due to the subsequent peak reconstruction. Sampling density (rho(S)) of resampling is the number of sampling periods per standard deviation of a peak at the outlet of the first-dimension column. It is shown that a simple formula describes the peak broadening as a function of rho(S) at any (even practically too low or too high) rho(S), for the peaks of any (not necessarily Gaussian) shape, for a wide class of peak reconstruction techniques, and for any 2-D separation (GC x GC, LC x LC, etc.). In capillary GC x GC, optimal rho(S) (rho(S,Opt)) depends on the type of the peak reconstruction and on the degree of the gas decompression along the second-dimension column. When reconstructing using linear interpolation, rho(S,Opt) = 0.7 at large and rho(S,Opt) = 0.5 at small gas decompression. The choice of exact optimal conditions is not critical. Thus, two-fold departure of actual rho(S) from rho(S,Opt) in either direction (under- or oversampling) causes only 10% drop in the net peak capacity of GC x GC. The quantitative effect of a much greater undersampling is also evaluated.  相似文献   

5.
More than a decade after Phillips' first published work this article reviews recent developments in comprehensive two-dimensional gas chromatography (GC x GC). Special attention is devoted to the further development and diversity of modulation devices. These include heated sweepers, cryofocused modulators, and a variety of diaphragm valve-switching strategies. It is demonstrated that all modulation approaches can be very well suited to GC x GC, depending on the particular application. Diaphragm-valve modulation is very powerful for volatile organic compounds. Slotted heater and cryofocused modulation are preferred for samples that contain non-volatile components. Applications ranging from petroleum to environmental and biological samples are illustrated. Extension of the technique to GC x GC-mass spectrometry (MS) is also discussed and trends for future research activity are pointed out.  相似文献   

6.
The coupling of headspace solid-phase microextraction (HS-SPME) with comprehensive two-dimensional gas chromatography (GC x GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one-dimensional (1-D) GC, the improved analytical capabilities of GC x GC in terms of increased detection sensitivity and separation power were demonstrated by using HS-SPME/GC x GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2-D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2-D GC x GC plot.  相似文献   

7.
Lu X  Kong H  Li H  Ma C  Tian J  Xu G 《Journal of chromatography. A》2005,1086(1-2):175-184
A model is developed for predicting the resolution of interested component pair and calculating the optimum temperature programming condition in the comprehensive two-dimensional gas chromatography (GC x GC). Based on at least three isothermal runs, retention times and the peak widths at half-height on both dimensions are predicted for any kind of linear temperature-programmed run on the first dimension and isothermal runs on the second dimension. The calculation of the optimum temperature programming condition is based on the prediction of the resolution of "difficult-to-separate components" in a given mixture. The resolution of all the neighboring peaks on the first dimension is obtained by the predicted retention time and peak width on the first dimension, the resolution on the second dimension is calculated only for the adjacent components with un-enough resolution on the first dimension and eluted within a same modulation period on the second dimension. The optimum temperature programming condition is acquired when the resolutions of all components of interest by GC x GC separation meet the analytical requirement and the analysis time is the shortest. The validity of the model has been proven by using it to predict and optimize GC x GC temperature programming condition of an alkylpyridine mixture.  相似文献   

8.
A new method for performing comprehensive GC x GC in the stop-flow mode is presented. A device was used to pneumatically stop the flow in the first dimension ((1)D) (by applying pressure pulses at the junction between the two columns), while flow was maintained in the second dimension ((2)D). This allowed for better preservation of resolution in the (1)D of the GC x GC chromatograms, and the extension of the (2)D's separation space, reducing or eliminating the extent of wraparound. When increased flow rates in the (2)D were used, sensitivity enhancements were also observed.  相似文献   

9.
The present research is focused on the offline combination of normal-phase LC to double-oven GC x GC-quadrupole MS. Initially, a diesel sample was subjected to automated LC x GC in order to define the elution windows of four fractions, viz., saturated hydrocarbons, monocyclic aromatics, dicyclic aromatics, tri- + tetracyclic aromatics; each fraction was collected exploiting the LC system in a further analysis and subjected to large-volume-injection-GC x GC analysis using an apolar-polar column combination. The GC x GC operational conditions were tuned in relation to the specific separation requirements of each heart-cut. The main benefits of what can be defined as offline LC-GC x GC were: (i) the high first-dimension LC selectivity; (ii) the injection of high sample amounts in the GC x GC system, enabling the detection and quantification of a series of low-amount diesel constituents; (iii) improved GC x GC operational conditions for each heart-cut with respect to direct GC x GC.  相似文献   

10.
The study evaluates the influence of selectivity tuning of the stationary phase of the second dimension on the orthogonality of a comprehensive two-dimensional gas chromatography (GC x GC) system. Two different sets of columns, providing independent and semi-independent separation mechanisms were used. The first consisted of a first dimension separating analytes on a volatility basis (i.e. a non-polar polydimethylsiloxane (OV1) column) combined with a second dimension separating by polarity, using columns coated with 100% polyethylene glycol (CW20M), CW20M/OV1 mixtures in ratios of 25-75%, and polydimethylsiloxane, 7% phenyl, 7% cyanopropyl (OV1701). The second set consisted of a first dimension separating analytes on a polarity basis (100% CW20M column) combined with a second dimension separating by volatility, consisting of columns coated with 100% OV1, OV1/CW20M mixtures in ratios of 25-75%, and 100% OV1701. Medium-complexity mixtures of natural origin (i.e. peppermint essential oil and a standard mixture of suspected allergens) consisting of components in a relatively limited range of molecular weights (MW) and volatilities, but belonging to different classes of compounds in a wide range of polarity (mono- and sesquiterpenoids, hydrocarbons and oxygenated compounds) were analysed with the above sets of columns. Different approaches were used to evaluate peak spreading on the GC x GC separation plane and degree of orthogonality of the column sets, namely: (1) a Factor Analysis (FA) approach, estimating the correlation coefficients and spreading angles of the sample components in the two-dimensional chromatographic plane; (2) an Informational Theory (IT) approach, based on determining a group of parameters including: informational entropy, % synentropy and similarity (H); and (3) an approach based on estimating the amount of separation space used, i.e. a practical parameter that directly refers to the experimental separation plane of the GC x GC chromatogram. Results showed that peak spreading in the chromatographic plane, when CW20M and OV1 are combined in different ratios, can be predicted from retention mechanisms, and that the degree of orthogonality measured with different approaches, is consistent with the divergent nature, in terms of polarity of the stationary phases combined in the GC x GC system.  相似文献   

11.
The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis. Best features of GC x GC are demonstrated and compared to these techniques in terms of cost, time consumption and accuracy. In particular, a new approach of simulated distillation (SimDis-GC x GC) is proposed: compared to the standard method ASTM D2887 it gives unequal information for better understanding of conversion process.  相似文献   

12.
Comprehensive two-dimensional gas chromatography (GC x GC) is based on a coupling of two GC columns of different characteristics by means of a device that allows portions of the effluent from the primary column to be injected onto the second dimension column for an additional separation. The time available for the separation in the second-dimension column is very short. Thus, this separation should be very efficient. The vast majority of GC x GC practitioners use very narrow bore columns for the second dimension. While this approach is justified in principle, if peaks in the second dimension overload this column, its peak capacity is severely reduced. A series of second-dimension columns of varying internal diameters, but similar phase ratios, were used to study these effects. The results indicate that 250 microm columns often provide comparable second dimension peak widths to 100 microm columns, while at the same time being less prone to overloading, indicating that they may often be a better choice than smaller diameter columns in the second dimension of GC x GC systems.  相似文献   

13.
A simple, single-stage CO2 jet modulator has been designed, which cools only a single, ca. 10 mm long section of the front part of the second-dimension column of a comprehensive two-dimensional gas chromatographic (GC x GC) system. Direct heating by means of the GC oven air effects remobilization of the small fractions trapped upon eluting from the first-dimension column within a predetermined short period of time. Evaluation of the present modulator for the GC x GC separation of (very) polar flavour as well as non-polar compounds shows that the analytical performance of the single-stage modulator is closely similar to that of earlier reported, more complex, types of modulator.  相似文献   

14.
Comprehensive two-dimensional gas chromatography (GC x GC) offers new opportunities to develop relationships between molecular structure and retentions in the two dimensional (2D) separation space defined by the GC x GC retention in each dimension. Whereas single dimension GC provides only one retention property for a solute, and hence the specific relationship between retention and chemical property is not readily apparent or derivable, the 2D presentation of compounds in GC x GC provides a subtle and exquisite correlation of chemical property and retention unlike any other GC experiment. The 'orthogonality' of the two separation dimensions is intimately related to the manner in which different separation mechanisms, available through use of two dissimilar phases, are accessible to the different chemical compounds or classes in a sample mixture, and indeed the specific chemical classes present in the sample. The GC x GC experiment now permits various processes such as chemical decompositions, molecular interconversions, various non-linear chromatography effects, and processes such as slow reversible interactions that may arise with stationary phases or in the injector or column couplings, to be identified and further investigated. Here, we briefly review implementation of the GC x GC method, consider the molecular selectivity of GC x GC, and highlight a selection of molecular processes that can be probed by using GC x GC.  相似文献   

15.
全二维气相色谱技术及其进展   总被引:37,自引:2,他引:35  
许国旺  叶芬  孔宏伟  路鑫  赵欣捷 《色谱》2001,19(2):132-136
 许多分析问题的解决需要得到比一维色谱技术能提供的更高的分辨率。分离能力可通过使用多种分离技术或机理的组合来增强。此时 ,样品被分散在不同的时间维 ,最终的分辨率强烈地依赖于这些维间分离特性的差异。当它们之间没有关联 ,也即相互间正交时 ,系统可获得最高的分辨率。全二维气相色谱 (GC×GC)提供了一个真正的正交分离系统。它把分离机理不同而又互相独立的两支色谱柱以串联方式结合组成二维气相色谱。在这两支色谱柱之间装有的一个调制器起捕集再传送的作用。全二维色谱的峰容量为组成它的两支色谱柱各自峰容量的乘积。  相似文献   

16.
After a successful off-line feasibility study, the automation of comprehensively coupled liquid chromatography and gas chromatography (LC x GC) has been studied. Important aspects to consider when developing automated LG x GC include the relative speeds of the two dimensions, the compatibility of the LC eluent (type and flow rate) with the GC dimension, and the column loadabilities. Because the GC separation is relatively slow, the LC instrument has to be operated in the stop-flow mode. Two interfaces for transferring large numbers of subsequent LC fractions to the GC were constructed: one based on a six-port switching valve, and one which uses a dual side-port syringe. Both interfaces were found to perform fully acceptably. The actual transfer of the LC fraction to the GC was realised using a standard split injector to vaporise the compounds and LC eluent. Gas phase splitting was applied to match LC mass load and GC column loadability. The standard deviations of the peak areas obtained in this way were better than 7% (n = 6). The reliability of the system was demonstrated by the problem-free analysis of large series of oil and fat samples, with the focus on both intact triglycerides and their fatty acid methyl esters (FAMEs). Finally, the hyphenation of the automated LC x GC system to a sensitive and rapid-scanning time-of-flight mass spectrometer was realised. By using LC x GC-ToF MS, the information density of the chromatograms could be improved even further, which allowed easy identification of individual compounds as well as compound groups.  相似文献   

17.
This paper investigates the separation of moderately complex samples by comprehensive two‐dimensional gas chromatography (GC×GC). The analysis of peppermint (Mentha piperita) and spearmint (Mentha spicata) essential oil components, including acetates, alcohols, furans, ketones, sesquiterpenes, and terpenes, was achieved by one‐dimensional gas chromatography with quadrupole mass spectrometry detection (GC/MSD) and GC×GC with flame ionization detection. Peppermint essential oil was found to contain 89 identifiable peaks by GC×GC compared to 30 peaks in the GC/MSD chromatogram. Likewise, 68 peaks were found in the GC×GC chromatogram of spearmint (compared to 28 in GC/MSD). Plots of the first dimension versus second dimension retention times provided a fingerprint of the two essential oils, which revealed 52 similar compounds between the two essential oils as opposed to 18 matches by 1D GC.  相似文献   

18.
Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.  相似文献   

19.
The analysis of the cellular lipidic fraction of bacteria is described. After hydrolysis and methylation, the fatty acid methyl esters (FAMEs) are determined by 1-D GC using the Sherlock MIDI bacteria identification system, by comprehensive GC (GC x GC) and by GC-MS in electron impact (EI) and positive chemical ionisation (PCI) mode. With GC x GC, the enhanced selectivity and group type separation provides a more complete elucidation of the fatty acids in microorganisms. GC-EI-MS and GC-PCI-MS were helpful for confirmation. The bacteria selected in this study are Brevundimonas diminuta, Chryseobacterium gleum and Stenotrophomonas maltophilia.  相似文献   

20.
The present research is focused on the use of comprehensive 2-D GC (GC x GC) for the elucidation of the human plasma fatty acid (FA) profile. The enhanced sensitivity, increased separation power and the formation of group-type patterns provided by GC x GC enabled the identification and quantification of a high number of both well known and unexpected FAs, for a total of 65 components. Peak assignment was, in most cases, supported by using pure standard compounds. The results attained demonstrated the usefulness of the multidimensional GC method in this fundamental field of research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号