首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
Monoacylglycerols (MAGs) are lipids found in trace amounts in plants and animal tissues. While they are widely used in various industrial applications, accurate determination of the regio-specific distribution is hindered by the lack of stable, commercially available standards. Indeed, unsaturated β-MAG (or Sn-2 MAG) readily undergoes isomerization into α-MAG (acyl chain is attached to the Sn-1 or the Sn-3 position). In the present study, we describe structural elucidation of α- and β-regio-isomers of monopalmitoyl-glycerol (MAG C16:0) as model compounds in their silylated forms using gas chromatography–mass spectrometry (GC–MS) with electronic impact (EI) ionization. MS fragmentation of α-MAG C16:0 is characterized by the loss of methylene(trimethylsilyl)oxonium (103 amu) and the consecutive loss of acyl chain yielding a fragment ion at m/z 205. The fragmentation pattern of β-MAG C16:0 shows a series of diagnostic fragments at m/z 218, 203, 191 and 103 that are not formed from the α-isomer and hereby enable reliable distinction of these regio-isomers. Possible fragmentation scenarios are postulated to explain the formation of these marker ions, which were also applied to characterize the regio-isomer composition of a complex mixture of MAG sample containing n-3 long-chain polyunsaturated fatty acids.  相似文献   

2.
Pyrolysis gas chromatography–mass spectrometry (PyGC-MS) was used as a rapid method for the characterization of permanent marker ink. Twenty-four samples of various colours purchased from different manufacturers were characterised. Four main typologies of polymer-binding medium could be distinguished on the basis of the pyrolysis products, and differentiation between permanent markers of different manufacturers could be accomplished. For some permanent marker samples, PyGC-MS analysis allowed pigment identification as well.  相似文献   

3.
4.
Bacteria communicate with each other by a process termed “quorum sensing” (QS), and diffusible, low-molecular-weight chemicals, called signal molecules, are used as the communication languages. In cell-free Burkholderia cepacia CF-66 culture supernatants, five compounds suspected of being signal molecules were identified. The gene (cepI) related with AHLs synthesis were not detected by polymerase chain reaction (PCR) using specific primers. Gas chromatography–mass spectrometry (GC–MS) revealed that these compounds were not AHLs but the diketopiperazines (DKPs) cyclo(Pro–Phe), cyclo(Pro–Tyr), cyclo(Ala–Val), cyclo(Pro–Leu), and cyclo(Pro–Val), all of which were both d and l-type. Four kinds of DKPs had been isolated from other Gram-negative bacteria, but the other was a novel kind discovered in CF-66, and l-cyclo (Pro–Phe) was quantified by GC–MS. It was found that exogenous DKPs had a negative effect on the candidacidal activity of the culture supernatant extracts.  相似文献   

5.
This article reports on the chemical analysis of molecular profiles of tarsal secretions of the desert locust Schistocerca gregaria (Forsskål, 1775) by gas chromatography hyphenated with quadrupol mass spectrometry (GC–MS) as well as 1H-nuclear magnetic resonance (1H NMR) spectroscopy. Special focus of this study was to elaborate on sampling methods which enable selective microscale extraction of insect secretions in a spatially controlled manner, in particular tarsal adhesive secretions and secretions located on cuticle surfaces at the tibia. Various solvent sampling procedures and contact solid-phase microextraction (SPME) methods were compared in terms of comprehensiveness and extraction efficiencies as measured by signal intensities in GC–MS. Solvent sampling with water as extraction solvent gave access to the elucidation of chemical profiles of polar compound classes such as amino acids and carbohydrates, but is extremely tedious. Contact SPME on the other hand can be regarded as a simplified and more elegant alternative, in particular for the lipophilic compound fraction. Many proteinogenic amino acids and ornithine as well as carbohydrate monomers arabinose, xylose, glucose, and galactose were detected in tarsal secretions after acid hydrolysis of aqueous extracts. Qualitatively similar but quantitatively significantly different molecular profiles were found for the lipid fraction which contained mainly n-alkanes and internally branched monomethyl-, dimethyl-, and trimethyl-alkanes in the C23–C49 range as well as long chain fatty acids and aldehydes. Especially, hydrocarbons with >C40 carbon numbers have previously been rarely reported for insect secretions. The results suggest that the investigated insect secretions are complex emulsions which allow the attachment of tarsi on various otherwise incompatible materials of smooth and rough surfaces. The solid consistence of the established alkanes at ambient temperatures might contribute to a semi-solid consistence of the adhesive, amalgamating partly opposing functions such as slip resistance, tarsal release, desiccation resistance, and mechanical compliance. The methods developed can be extended to other similar applications of studying compositions of insect secretions of other species.  相似文献   

6.
Gas chromatography (GC) data (linear retention indices and relative areas) and mass spectra (most representative m/z fragments) of 12 reducing trisaccharides as trimethylsilyl oximes (TMSO) and four non-reducing as trimethylsilyl (TMS) ethers have been described for the first time and related to their structural features. Some trends have been observed: earlier elution of non-reducing compounds and fructotrioses; aldotrioses bearing the reducing end with link in position 6 showing the highest retention. Abundance of several fragment ions and their ratios were useful for trisaccharide characterization; some of these features seem to be useful for the characterization of new trisaccharides.  相似文献   

7.
A method based on gas chromatography-mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and (13)C-labeled analogues were used for identification and quantitative analysis. Excellent chromatographic separation of the monosaccharide derivatives was found and identification of the anomeric configuration was feasible through a prepared and identified pure methyl 2,3,4,6-tetra-O-acetyl-β-D-glucopyranoside. The electron ionization mass spectrum and fragmentation path was studied for each monosaccharide derivative. Fragment ion pairs of labeled and unlabeled monosaccharides were used for quantification; m/z 243/248 for glucose, 128/132 for xylose, and 217/218 for arabinose. Using the intensity ratios obtained from the extracted ion chromatograms, accurate quantification of monosaccharide constituents of selected hemicelluloses was demonstrated.  相似文献   

8.
A preliminary investigation using gas chromatography–mass spectrometry (GC–MS) to analyze the nicotine contained in tobacco leaves was carried out. Nicotine is an alkaloid and tobacco leaves was extracted with methanol and determined by GC–MS. The detection limit for nicotine was at the ppm level for non selective monitoring and the nanogram level for selective detection. This is a simple chromatography–mass spectrometry method for the analysis of nicotine in tobacco leave. Compared to other currently utilized methods for the detection of nicotine in tobacco leaves, the GC–MS provided advantages of high sensitivity, nicotine specific detection and lower instrumentation cost.  相似文献   

9.
Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis–gas chromatography–mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL?1 is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time.
Figure
SEC/-/Py-GC-MS (reconstructed, chromatograms) of dissolved polymer in ACN/THF%.  相似文献   

10.
n-Butyl benzyl phthalate (BBP) is an endocrine-disrupting chemical. A bacterium species capable of using BBP as the sole source of carbon and energy was isolated from mangrove sediment. Effects of BBP concentration, pH, temperature, and salinity on BBP biodegradation were studied. The optimum pH, temperature, and salinity for the BBP biodegradation were 7.0, 37°C, and 15 g L−1, respectively. BBP was completely degraded within 6 days under optimum conditions, and the biodegradation of BBP could be fitted to a first-order kinetic model. The major metabolites of BBP biodegradation were identified as mono-butyl phthalate, mono-benzyl phthalate, phthalic acid, and benzoic acid by using high-performance liquid chromatography and gas chromatography–mass spectrometry. A preliminary metabolic pathway was proposed for the biodegradation of BBP.   相似文献   

11.
Pyrolysis gas chromatography–mass spectroscopy (PGC–MS) has been proved to be a powerful method to analyze both the volatile additives and the macromolecular structure of polymer materials. In this paper, flash evaporation technique was used to analyze the volatile degradation products of polymer materials during natural and artificial aging. In high density polyethylene (HDPE) composites, mainly n-alkanes with carbon number from 14 to 29 were detected after natural aging, while no oxidative product was found. Different composites have different n-alkane distributions. In contrast, various oxidative products including ketones, alcohols, esters and unsaturated species could be found in aged polypropylene (PP) nanocomposites. Nanoparticles accelerated the chain scission of PP and increased the formation of oxidative products significantly. During thermal oxidation of nitrile rubber (NBR) seal rubbers, heat/oxidation-induced extra crosslinking predominated and no volatile degradation products was detected. The main change happened in the volatiles is the decrease of additives, especially paraffins, antioxidant RD and hindered phenol. This resulted in the hardening of the rubber and the weakening of the protection from oxidation. Furthermore, the additive distribution along the depth was investigated, showing different migration speeds of different additives. From the additive levels remained in the NBR rubber, it is possible to predict the degradation status. In summary, PGC–MS can supply abundant information of polymer degradation and is helpful for mechanism research.  相似文献   

12.
A headspace solid-phase microextraction (HS-SPME) method in combination with gas chromatography–mass spectrometry (GC–MS) has been used for extraction and identification of components of the volatile fraction of Provola dei Nebrodi, a typical semi-hard Sicilian cheese. Cheese samples from different producers and at different ripening stages have been examined. The effects of various conditions (e.g. sample volume, sample headspace volume, sample heating temperature, extraction time, etc.) on extraction efficiency were studied in order to optimise the technique. The technique used made it possible to identify 61 components: fatty acids from C2 to C14 and their esters, aldehydes, alcohols, methyl ketones, -lactones, aromatic compounds, hydrocarbons and terpenes. The main components were butanoic, hexanoic and octanoic acids. The linear free fatty acids (FFA) from C2 to C10 were quantified by using the standard addition method. Calibration curves constructed for the FFA spiked into cheese were highly linear with a correlation coefficient R2>0.998. Significant statistical differences (P0.05) were evident for the even-carbon-number fatty acids during ripening.  相似文献   

13.
Gas chromatography–combustion–isotope mass spectrometry was employed for the assessment of the Carbon isotope ratios of volatiles in Italian mandarin and lemon petitgrain oils. In addition, the composition of the whole oil and the enantiomeric distribution of selected chiral compounds were determined for all the samples by using gas chromatography and by multidimensional and conventional enantioselective gas chromatography. The composition of the oils was compared with previous studies. The enantiomeric distribution of lemon petitgrain oils is here reported for the first time. On the composition of mandarin petitgrain oil, the information available in literature, to date, is relative only to one sample from Egypt. Carbon isotope ratio of several terpene hydrocarbons and of their oxygenated derivatives contained in petitgrains was compared with the δ 13CVPDB values of the same compounds present in the corresponding genuine Italian Citrus peel oil. The results prove that the isotopic values obtained for lemon and mandarin petitgrain oils are very close to those relative to the corresponding peel oils determined in previous studies.  相似文献   

14.
A new and simple APPI interface employing commercially available hardware is used to combine GC to MS. The feasibility of the method is demonstrated in the analysis of urine samples for neurosteroids as their trimethylsilyl (TMS) derivatives. The effect of different dopants (chlorobenzene, toluene, anisole) on the ionization of the TMS derivatives was investigated. With chlorobenzene, the TMS derivatives produced intense molecular ions with minimal fragmentation, and chlorobenzene was selected as best dopant. Protonated molecules in addition to intense molecular ions were produced with toluene and anisole. The performance of the method was verified in the analysis of human urine samples. Chromatographic performance was good with peak half-widths of 3.6–4.3 s, linearity (r2 > 0.990) was acceptable, limits of detection (LODs) were in the range of 0.01–10 ng mL−1, and repeatability was good with relative standard deviations (rsd%) below 22%. The results show that the method is well suited for the determination of neurosteroids in biological samples.  相似文献   

15.
A derivatization procedure for the qualitative gas chromatography–mass spectrometry (GC-MS) analysis of pinacolyl alcohol (PA) that employs phenyldimethylchlorosilane (PhDMClS) and the promoter N-methylimidazole is described. While PA, underivatized, can be detected using conventional gas chromatographic methods, its polarity and low boiling point make its detection in complex matrices challenging. The silylation procedure described herein generates a PA-derivative exhibiting an increased on-column retention time, thus shifting its GC-MS signal away from commonly encountered, volatile, interfering analytes. Derivatized PA could be distinguished from other PhDMClS-derivatized isomeric alcohols by its unique retention time and mass spectrum. The derivatization was demonstrated to perform well in the GC-MS analysis and identification of PA in samples from Proficiency Tests administered by the Organisation for the Prohibition of Chemical Weapons (OPCW).
Figure
NMI-Accelerated Silylation of Pinacolyl Alcohol for GC-MS Analysis  相似文献   

16.
An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography–mass spectrometry (LC–MS). With this set-up strong improvement of sensitivity in the LC–MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(–)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.  相似文献   

17.
A method for the determination of 19 chlorophenols in industrial effluents samples using solid-phase microextraction (SPME) coupled to gas chromatography–mass spectrometry has been developed. Four kinds of different SPME fibres have been studied. Among them, the polyacrylate and carbowax®-divinylbenzene fibres were the most adequate. The extraction process was optimized by means of the experimental design, which allows the study of a large number of factors with a reasonable number of experiments. The optimized method allows the determination of the studied chlorophenols in complex matrices with a high organic content with detection limits down to 0.07?ng?mL?1 and RSD ranging from 4.4% to 13.8%. The recovery studies with spiked real effluent samples at low levels of chlorophenols ranged from 59.8% to 142.1% for the lowest level (0.5?ng?mL?1) and from 79.6% to 115.8% for the highest spiked level (2?ng?mL?1). These results show the suitability of the proposed method to monitor chlorophenols in complex samples. 2,4,5-TCP was detected at concentrations close to its limits of detection in effluents coming from an oil refinery.  相似文献   

18.
Due to the toxicity of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F), efforts are made to quantify their emission into the environment. Typically, this quantification is done using gas chromatography–high-resolution mass spectrometry (GC–HRMS). However, GC–HRMS is extremely expensive and time consuming, and GC–HRMS facilities are overly requested. In order to decrease the workload on GC–HRMS, another alternative is to use an enzyme-linked immunosorbent assay (ELISA) as a semi-quantitative screening tool. One problem of this solution is that ELISA measures the total PCDD/F content of a sample differently than GC–HRMS; a disparity exists between the two techniques. This paper introduces a congener correction factor that adjusts ELISA results for this incompatibility. The importance of the correction factor is explored by examining the congener profiles of 27 different dioxin sources. The congener profiles for many of these sources are such that large incompatibilities in predicted PCDD/F content would likely exist between uncorrected ELISA and GC–HRMS. The effect that the correction factor has on the correlation between ELISA and GC–HRMS for samples from a test site with dioxin-contaminated soils was also examined. The congener profile at this site was such that the inconsistencies between uncorrected ELISA and GC–HRMS results were relatively small. However, application of the congener correction factor still improved the correlation between ELISA and GC–HRMS by 11% when using sample-specific correction factors and by 5% when using an average site-wide correction factor. The findings of this paper suggest that application of the correction factor is necessary to remove incompatibilities between ELISA and GC–HRMS—particularly when the congener profile at a site would lead to incompatibilities that are large.  相似文献   

19.
In this study, a simple and efficient large volume injection gas chromatography–mass spectrometry (GC-MS) method, via a programmable-temperature vaporizer (PTV) inlet, has been developed and applied in the determination of estrogens in environmental water samples without a prior derivatization process. Three commonly used estrogens estrone, 17 β-estradiol and 17 α-ethynylestradiol were selected as target compounds for this study. It has been demonstrated that the type of gas chromatograph liner and the initial inlet temperature can greatly affect the response intensity of estrogens. Three different types of PTV liners have been studied; the multibaffle liner generated the strongest response intensities towards the estrogen analytes. The results showed that the response intensities of estrogens reduced sharply while the initial inlet temperature increased. Various instrument conditions and sample preparation methods were studied in detail. The optimized method has been validated with good linearity, precision and accuracy. The method detection limit of each estrogen was found to be 0.041 ng/L for estrone, 0.046 ng/L for 17 β-estradiol and 0.031 ng/L for 17 α-ethynylestradiol. To the best of our knowledge, these results represent the best sensitivities achieved for estrogens analyzed in water samples via traditional GC-MS method without a derivatization process. This method has been successfully applied in the analyses of different water samples.  相似文献   

20.
This paper reports a multiresidue analysis procedure which permits the identification and quantification of sixty-three water-soluble pollutants. Subsequent to their solid-phase extraction (SPE) enrichment, analyses of species have been carried out from one solution, by a single injection, as their trimethylsilyl-oxime ether/ester derivatives, by gas chromatography–mass spectrometry, within 31 min. Based on our optimized extraction, derivatization and mass fragmentation studies separation have been performed in the total ion current mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Including various pharmaceuticals, benzoic acid, its substituted species, different aromatic carboxylic acids, cholic acids, unsaturated and saturated fatty acids, aliphatic dicarboxylic acids, as well as synthetic pollutants of various origins (2,4-di-tert-butylphenol, different phthalates). Standard compounds were added to 500 mL effluent wastewater samples, at three concentrations (1–5 μg/L, 5–10 μg/L and 10–20 μg/L). Recoveries, using the Waters Oasis cartridges performing extractions at pH 2, pH 4 and pH 7 proved to be the optimum at pH 4 (average recoveries (94.5%), except for cholesterol (10%), paracetamol (18%) and 2,5-dihydroxybenzoic acid (25%). Carbamazepine could be recovered at pH 7, only. Responses, obtained with derivatized standards proved to be linear in the range of 4–80 μg/L levels. Limit of quantitation values varied between 0.92 ng/L (4-hydroxyphenylacetic acid) and 600 ng/L (dehydrocholic acid) concentrations. One of the most important messages of this work is the confirmation of the origin of blank values. It was shown that contaminants, mainly 2,4-di-tert-butylphenol, different phthalates and fatty acids, are sourced both from the reagents and mainly from the SPE procedure, independent on the cartridge applied. Reproducibilities, characterized with the relative standard deviations (RSDs) of measurements, varied between 0.71% and 10%, with an average of 4.38% RSD. The practical utility of the method was shown by the identification and quantification of the pollutant contents of Hungarian influent and effluent wastewaters (for six consecutive months and that of the Danube River for 2 months).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号