首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
The bismuth‐coated electrode is known to be prone to errors caused by copper(II). This study investigates copper(II) interference at bismuth film electrode for the detection of lead(II) and cadmium(II). It was conducted using glassy carbon electrode, while the bismuth film was plated in situ simultaneously with the target metal ions at ? 1200 mV. Copper(II) presented in solution significantly reduced the sensitivity of the electrode, for example there was an approximately 70 % and 90 % decrease in peak signals for lead(II) and cadmium(II), respectively, at a 10‐fold molar excess of copper(II). The decrease in sensitivity was ascribed to the competition between copper and bismuth or the metal ions for surface active sites. Scanning electron microscopy (SEM) and energy dispersive X‐ray (EDX) analysis suggested a large decrease in the amount of bismuth nanoparticles formed on the electrode surface in the presence of copper(II) occurred, validating the competition between copper and bismuth ions for surface active sites. Recovery of the stripping signal of lead(II) and cadmium(II) was obtained by adding ferrocyanide ion to the solution. Finally, the proposed method was successfully applied to determine lead(II) and cadmium(II) in water samples and the method was validated by ICP‐MS technique.  相似文献   

2.
The voltammetric performance of an in situ plated antimony film screen-printed carbon electrode in hydrochloric acid, acetate buffer, and tartrate buffer was evaluated for the detection of copper(II) with differential pulse anodic stripping voltammetry. The tartrate buffer was superior, providing high sensitivity and good separation of copper and antimony stripping peaks. The analytical conditions for the determination of copper(II) were optimized. The detection limit was estimated to be 0.14?µg?L?1 copper(II) and the relative standard deviation for 2.5?µg?L?1 copper(II) was 3%. The applicability of the method was illustrated by the analysis of soil conditioner samples.  相似文献   

3.
The key to remediative processes is the ability to measure toxic contaminants on-site using simple and cheap sensing devices, which are field-portable and can facilitate more rapid decision-making. A three-electrode configuration system has been fabricated using low-cost screen-printing (thick-film) technology and this coupled with a portable electrochemical instrument has provided a a relatively inexpensive on-site detector for trace levels of toxic metals. The carbon surface of the screen-printed working electrode is used as a substrate for in situ deposition of a metallic film of bismuth, which allows the electrochemical preconcentration of metal ions. Lead and cadmium were simultaneously detected using stripping chronopotentiometry at the bismuth film electrode. Detection limits of 8 and 10 ppb were obtained for cadmium(II) and lead(II), respectively, for a deposition time of 120 s. The developed method was applied to the determination of lead and cadmium in soils extracts and wastewaters obtained from polluted sites. For comparison purposes, a mercury film electrode and ICP-MS were also used for validation.  相似文献   

4.
Niu X  Zhao H  Lan M 《Analytical sciences》2011,27(12):1237-1241
Integrating the advantages of screen printing technology with the encouraging electroanalytical characteristic of metallic bismuth, we developed an ultrasensitive and disposable screen-printed bismuth electrode (SPBE) modified with multi-walled carbon nanotubes (MWCNTs) for electrochemical stripping measurements. Metallic bismuth powders and MWCNTs were homogeneously mixed with graphite-carbon ink to mass-prepare screen-printed bismuth electrode doped with multi-walled carbon nanotubes (SPBE/MWCNT). The electroanalytical performance of the prepared SPBE/MWCNT was intensively evaluated by measuring trace Hg(II) with square-wave anodic stripping voltammetry (SWASV). The results indicated that the SPBE modified with 2 wt% MWCNTs could offer a more sensitive response to trace Hg(II) than the bare SPBE. The stripping current obtained at SPBE/MWCNT was linear with Hg(II) concentration in the range from 0.2 to 40 μg/L (R(2) = 0.9976), with a detection limit of 0.09 μg/L (S/N = 3) under 180 s accumulation. The proposed "mercury-free" electrode, with extremely simple preparation and ultrahigh sensitivity, holds wide application prospects in both environmental and industrial monitoring.  相似文献   

5.
崔春国 《化学学报》1983,41(10):927-933
A method of simultaneous determination of copper (II), lead (II) and cadmium (II) in sulphuric acid-iocide ion medium was established by derivative anodic stripping voltammetry (DASV) on the gold electrode. The peak theights of lead and cadmium were increased by enhancement effect of iodide ion and the peaks of bismuth and copper were well formed and completely resolved on gold electrode in the presence of iodide ion, therefore peak of copper is not affected by bismuth. The sensitivities for copper, lead and cadmium were very high and their peak potentials in the stripping voltammogram were +0.25, -0.2 and -0.27 volt, respectively. The dependence of peak height of these elemets on their concentrations was linear. The detection limits for copper, lead and cadmium were 0.2 0.2 and 0.05 ppb, respectively. We have further studied the electrode process by means of triangle cyclic voltammetry and proved that he electrode reaction of copper is reversible, and that the reversibility of electrode reactions of lead and cadmium is not good.  相似文献   

6.
Hwang GH  Han WK  Park JS  Kang SG 《Talanta》2008,76(2):301-308
A bismuth-modified carbon nanotube electrode (Bi-CNT electrode) was employed for the determination of trace lead, cadmium and zinc. Bismuth film was prepared by in situ plating of bismuth onto the screen-printed CNT electrode. Operational parameters such as preconcentration potential, bismuth concentration, preconcentration time and rotation speed during preconcentration were optimized for the purpose of determining trace metals in 0.1M acetate buffer solution (pH 4.5). The simultaneous determination of lead, cadmium and zinc was performed by square wave anodic stripping voltammetry. The Bi-CNT electrode presented well-defined, reproducible and sharp stripping signals. The peak current response increased linearly with the metal concentration in a range of 2-100 microg/L. The limit of detection was 1.3 microg/L for lead, 0.7 microg/L for cadmium and 12 microg/L for zinc (S/N=3). The Bi-CNT electrode was successfully applicable to analysis of trace metals in real environments.  相似文献   

7.
An in-situ antimony film screen-printed carbon electrode (in-situ SbSPCE) was successfully used for the determination of Cu(II) simultaneously with Cd(II) and Pb(II) ions, by means of differential pulse anodic stripping voltammetry (DPASV), in a certified reference groundwater sample with a very high reproducibility and good trueness. This electrode is proposed as a valuable alternative to in-situ bismuth film electrodes, since no competition between the electrodeposited copper and antimony for surface sites was noticed. In-situ SbSPCE was microscopically characterized and experimental parameters such as deposition potential, accumulation time and pH were optimized. The best voltammetric response for the simultaneous determination of Cd(II), Pb(II) and Cu(II) ions was achieved when deposition potential was −1.2 V, accumulation time 120 s and pH 4.5. The detection and quantification limits at levels of μg L−1 suggest that the in-situ SbSPCE could be fully suitable for the determination of Cd(II), Pb(II) and Cu(II) ions in natural samples.  相似文献   

8.
For the first time, a solid lead electrode (PbE) was exploited for adsorptive stripping voltammetric determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent. The calibration graphs for Ni(II) and Co(II) were linear from 0.059 to 0.59 µg L?1 and from 0.029 to 0.29 µg L?1 (accumulation time 120 s), respectively. The analytical parameters such as the detection limit and separation of analytical signals obtained at the solid lead electrode were comparable with those obtained using a lead film electrode while better in comparison to those reported before for the bismuth film or solid bismuth electrodes. Co(II) could be determined in the presence of a large excess of Ni(II) and Zn(II). The proposed electrode was applied to determine Co(II) and Ni(II) traces in certified reference material and a natural water sample with satisfactory results.  相似文献   

9.
The differential pulse anodic stripping voltammetry of copper and lead at the mercury film glassy carbon electrode is discussed. The mercury film prevents the occurrence of a monolayer stripping peak for copper. The influence of antimony and bismuth on the anodic stripping voltammetric behaviour of copper and lead is discussed. An interaction between copper and antimony distorts the copper stripping peak and gives rise to an intermediate peak. The method described is suitable for determining copper and lead simultaneously in EDTA extracts of soils.  相似文献   

10.
A sensitive anodic stripping voltammetric procedure at the bismuth film electrode (BFE) for trace analysis of copper (II) in the presence of gallium is presented. The new protocol circumvents the problems of overlapping stripping signals between copper and bismuth that previously hampered the analysis of copper at the BFE. The results illustrate that the addition of gallium not only improves the reproducibility of the bismuth stripping signal but also facilitates much improved resolution between the stripping signals of bismuth and copper. Investigations into the effect of gallium on the stripping response of copper and bismuth were studied showing a 4:1 gallium:copper mole ratio produces optimum signals from bismuth and copper indicating a possible stoichiometric relationship. Optimisation of other key variables including electrolyte composition, accumulation parameters and appropriate waveform settings were studied and optimised. The optimised procedures show a range of linear calibration plots (R2 > 0.994) ranging from 2 to 500 μg L−1 and the relative standard deviation for a solution containing 100 μg L−1 copper was 3.7% (n = 10). Utilising an accumulation time of 300 s the limit of detection was 1.4 μg L−1 (S/N = 3). This technique was successfully applied to the analysis of copper in tap water representing the first successful copper determination in real samples using the BFE.  相似文献   

11.
This work presents a disposable bismuth‐antimony film electrode fabricated on screen‐printed electrode (SPE) substrates for lead(II) determination. This bismuth‐antimony film screen‐printed electrode (Bi‐SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi‐SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen‐printed electrodes (BiSPE), antimony film screen‐printed electrodes (SbSPE) and bismuth‐antimony film glassy carbon electrodes (Bi‐SbGC). Under optimized conditions, the Bi‐SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 µg/L. The Bi‐SbSPE has been demonstrated successfully to detect lead in river water sample.  相似文献   

12.
A lab-made prototype consisting of a potentiostat with a flow-batch system was designed and implemented under the commercial off the shelf paradigm. The prototype is light-weight and suitable for laboratory performance. Its performance was evaluated with linear sweep voltammetry (LSV) study of ferrocyanide/ferricyanide redox couple and the obtained results were comparable to that obtained with a commercial potentiostat. The system was applied in the determination of lead in propolis samples. For this purpose, bismuth film electrode by square wave anodic stripping voltammetry (SWASV) was employed. The obtained results were validated by atomic emission spectroscopy with inductively coupled plasma and very good agreement was obtained.  相似文献   

13.
《Analytical letters》2012,45(11):2273-2284
Abstract

A novel voltammetric method—anodic—using a bismuth/poly(aniline) film electrode has been developed for simultaneous measurement of Pb(II) and Cd(II) at low µg L?1 concentration levels by stripping voltammetry. The results confirmed that the bismuth/poly(aniline) film electrode offered high‐quality stripping performance compared with the bismuth film electrode. Well‐defined sharp stripping peaks were observed for Pb(II) and Cd(II), along with an extremely low baseline. The detection limits of Pb(II) and Cd(II) are 1.03 µg L?1 and 1.48 µg L?1, respectively. The bismuth/poly (aniline) electrode has been applied to the determination of Pb(II) in tap water samples with satisfactory results.  相似文献   

14.
A novel, sensitive and selective adsorptive stripping procedure for simultaneous determination of copper, bismuth and lead is presented. The method is based on the adsorptive accumulation of thymolphthalexone (TPN) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the simultaneous determination of copper, lead and bismuth were studied using the Derringer desirability function. The optimum analytical conditions were found to be TPN concentration of 4.0 microM, pH of 9.0, and accumulation potential at -800 mV vs. Ag/AgCl with an accumulation time of 80 s. The peak currents are proportional to the concentration of copper, bismuth and lead over the 0.4-300, 1-200 and 1-100 ng mL(-1) ranges with detection limits of 0.4, 0.8 and 0.7 ng mL(-1), respectively. The procedure was applied to the simultaneous determination of copper, bismuth and lead in the tap water and some synthetic samples with satisfactory results.  相似文献   

15.
Three different commercial carbon nanomaterial-modified screen-printed electrodes based on graphene, carbon nanotubes and carbon nanofibers were pioneeringly tested as electrode platforms for the plating with Sb film. They were microscopically and analytically compared to each other and to the most conventional unmodified carbon screen-printed electrode (SPCE). The obtained detection and quantification limits suggest that the in-situ antimony film electrode prepared from carbon nanofibers modified screen-printed electrode (SbSPCE-CNF) produces a better analytical performance as compared to the classical SPCE modified with antimony for Pb(II) and Cd(II) determination, approving its appropriateness for measuring low μg L−1 levels of the considered metals. In-situ SbSPCE-CNF was successfully used for the simultaneous determination of Pb(II) and Cd(II) ions, by means of differential pulse anodic stripping voltammetry, in a certified reference estuarine water sample with a very high reproducibility and good trueness.  相似文献   

16.
The potentiality of the ex situ deposited bismuth film electrode, allied to the rotation of a glassy carbon disk electrode (BiFE‐RDE), was exploited in trace metal analyses of lead(II) and cadmium(II) by stripping chronopotentiometry (SCP). A single BiFE (6.2 nm film thickness) can be used for a 1‐day term with no significant variation in the analytical signal. The limit of detection (3σ) for a deposition time of 40 s and an oxidation current of 15×10?9 A was 1.5×10?8 M for Pb(II) and 3.0×10?8 M for Cd(II). BiFE‐RDE was successfully applied to the direct SCP determination of lead(II) in a fresh water certified material.  相似文献   

17.
This work reports the optimisation of a new analytical method for lead ion detection in milk; the electrochemical detection scheme is based on the method that was described in Part I [1]. It features the use of a disposable, environmentally friendly bismuth film electrode to replace the traditionally used (toxic) mercury one while here we report an arduous development of sample treatment so that the simple device can be applied as a screening tool in many settings. For this purpose, a milk pre-treatment procedure by means of wet digestion with HCl, HClO4, and H2O2 combined with an ultrasonic treatment was developed. The detection of lead ions in treated milk was then carried out using a disposable screen-printed electrode modified with Nafion® and an “in situ” bismuth film, with the analysis being performed in anodic stripping voltammetry mode. The analytical method developed allows the detection of milk contaminated with lead ions at a concentration of 20 μg Kg−1 (legal limit) and it can be proposed as a screening method for routine analysis of lead ions in milk with the advantage of employing inexpensive and portable instrumentation. Moreover, dedicated software supported by a portable instrument introduces procedures that are essential to avoid distortion from ambient lead contamination and also makes it possible for an unskilled operator to carry out each step of the analysis.  相似文献   

18.
The new iridium oxide film electrode, applied for the determination of lead(II), cadmium(II) and copper(II) traces using differential pulse anodic stripping voltammetry (DP ASV) is presented. The electrode display an interesting stripping voltammetric performance which compares with electrodes commonly used in voltammetry. The deposited film is known as anodically electrodeposited iridium oxide film (AEIROF). The AEIROF electrode is characterized by long‐term stability (more than 40 days) and very good reproducibility of the analytical signals in this time (≤12% for 0.5 μM of lead). The regeneration of iridium film is very simple in a time shorter than 60 seconds. The effects of various factors such as: thickness of AEIROF film, preconcentration potential and time, supporting electrolyte composition, potential interferences are optimized. The detection limit for AEIROF film electrode based on glassy carbon for an accumulation time of 30 s is as low as 7 nM for lead(II). The repeatability of the method at a concentration level of the lead(II) as low as 0.5 μM, expressed as RSD is 2.5% (n=10). The proposed method was successfully applied and validated by studying certified reference material CTA‐OTL‐1. Such an attractive use of ‘mercury–free’ ‐ environmentally friendly electrodes offers great promise to measure trace metals.  相似文献   

19.
A stable film of poly(3‐octylthiophene)–dihydroxyanthraquinone sulfonate has been synthesized electrochemically in non‐aqueous solution. The incorporation of dihydroxyanthraquinone sulfonate as an anionic complexing ligand into poly(3‐octylthiophene) film during electropolymerization was achieved and copper ions were accumulated by reduction on the electrode surface. The presence of dihydroxyanthraquinone sulfonate during the electrochemical polymerization of 3‐octylthiophene is shown to impact the sensitivity and the stability of the organic conducting film electrode response. The electroanalysis of copper(II) ions using conducting polymer electrode was achieved by differential pulse anodic stripping voltammetry with remarkable selectivity. The analytical performance was evaluated and linear calibration graphs were obtained in the concentration range of 50–400 ng mL?1 copper(II) ion for 240 seconds accumulation time and the limit of detection was found to be 7.8 ng mL?1. To check the selectivity of the proposed stripping voltammetric method for copper(II) ion, various metal ions as potential interferents were tested. The developed method was applied to copper(II) determination in certified reference material, NWRI‐TMDA‐61, trace elements in fortified water.  相似文献   

20.
The authors report on a disposable sensor for the differential pulse anodic stripping voltammetric (DPASV) determination of the ions Zn(II), Pb(II) and Cu(II). Simultaneous detection is accomplished by using a screen-printed carbon electrode (SPCE) co-modified with an in-situ plated bismuth (Bi)) film and gold nanoparticles (AuNPs). The synergistic effect of the Bi film, and the large surface and good electrical conductivity of the AuNPs strongly assist in the co-deposition of the three ions. Four well-defined and fully separated anodic stripping peaks, at 540 mV for Zn(II), 50 mV for Pb(II), 140 mV for Bi(III) and 295 mV for Cu(II), all vs. Ag/AgCl, can be seen. The modified SPCE was characterized by scanning electron microscopy, X-ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the sensor has a good response to these ions. The detection limits (at an S/N ratio of 3) are 50 ng·L?1 for Zn(II), 20 ng·L?1 for Pb(II), and 30 ng·L?1 for Cu(II). The method was applied to the determination of the 3 ions in spiked lake water samples.
Graphical abstract Schematic of screen-printed carbon electrode (SPCE) co-modified with a bismuth film and gold nanoparticles for electrochemical simultaneous determination of Zn(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetric (DPASV).
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号