1.
A sensitive method is described for the determination of trace bismuth based on the bismuth-bromopyrogallol red (BPR) adsorption at a carbon paste electrode (CPE). The overall analysis involved a three-step procedure: accumulation, reduction, and anodic stripping. Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, a 0.30 mol l−1 HCl solution containing 2.0×10−5 mol l−1 BPR as supporting medium; accumulation potential and time, −0.10 V, 3 min; reduction potential and time, −0.35 V, 60 s; scan rate 100 mV s−1; scan range from −0.35 to 0.15 V. It was found that the Bi(III)-BPR complex could be accumulated on the electrode surface during the accumulation period. Then the Bi(III) in the Bi(III)-BPR complex on the CPE surface was reduced to Bi(0) during reduction interval and finally reoxidized during the anodic stripping step for voltammetric quantification. Factors affecting the accumulation, reduction, and stripping steps were investigated. Interferences by other ions were studied as well. The detection limit was found to be 5×10−10 mol l−1 with a 3 min accumulation time. The linear range was from 1.0×10−9 to 5.0×10−7 mol l−1. Application of the procedure to the determination of bismuth in water and human hair samples gave good results.  相似文献   

2.
The polyamines, octyl-[2-(2-octylamino-ethylamino)-ethyl]-amine (L1) and octyl-{2-[2-(2-octylamino-ethylamino)-ethylamino]-ethyl}-amine (L2), have been used as anion ionophores in PVC-based membrane ion-selective electrodes. Different electrodes were prepared containing L1, or L2, and o-nitrophenyl octyl ether (NPOE) or bis(2-ethylhexyl)sebacate (DOS) as plasticizers. The response of the electrodes was tested in two different buffers, HEPES-KOH (pH 7) and MES-KOH (pH 5.6). Electrodes containing L1 and L2 with NPOE (E1 and E2, respectively) showed a Nernstian response for thiocyanate with a good response time. The detection limit, linear range and slope for electrode E1 were 3.8 × 10−6 mol dm−3, 1 × 10−5 to 1 × 10−1 mol dm−3 and −57.2 mV decade−1 at pH 5.6 and 4.47 × 10−6 mol dm−3, 1.95 × 10−5 to 1 × 10−1 mol dm−3 and −58.1 mV decade−1 at pH 7.0. For electrode E2 the detection limit, linear range and slope found were 2.63 × 10−6 mol dm−3, 7.94 × 10−6 to 1 × 10−1 mol dm−3 and −58.5 mV decade−1 at pH 5.6 and 1.23 × 10−5 mol dm−3, 7.95 × 10−5 to 1 × 10−1 mol dm−3 and −46.0 mV decade−1 at pH 7. In contrast, electrodes containing DOS as plasticizers gave only response at pH 5.6 (detection limit, linear range and slope at pH 5.6 were 3.16 × 10−5 mol dm−3, 1 × 10−4 to 1 × 10−1 mol dm−3 and −52.6 mV decade−1). Selectivity coefficients for different anions with respect to thiocyanate were calculated. The electrode E2 at pH 5.6 was also used for the determination of SCN by potentiometric titrations with Ag+ ions with good results. The electrode E2 was also used to determine concentrations of thiocyanate in biological samples.  相似文献   

3.
A procedure for the determination of gallium by differential pulse adsorptive stripping voltammetry (DPADSV), using different complexing agents (ammonium pyrrolidine dithiocarbamate (APDC), pyrocatechol violet (PCV) and diethyldithiocarbamate (DDTC)), has been optimized. The selection of the experimental conditions was made using experimental design methodology. Under these conditions, the calibration was made and the detection limit was determined for each gallium-ligand complex. A robust regression method was applied which allowed the elimination of anomalous points. The detection limit, with α=β=0.05, for gallium-APDC complex was 5.0×10−8 mol dm−3, for gallium-PCV complex was 9.9×10−9 mol dm−3, and the lowest detection limit (1.3×10−9 mol dm−3) was obtained with DDTC. For this reason, DDTC was selected for the determination of the gallium concentration in a certificate sample and in a spiked tap water sample. The linear dynamic range for gallium-APDC complex was from 5.0×10−8 to 2.7×10−7 mol dm−3, for gallium-PCV complex was from 5.0×10−9 to 4.8×10−7 mol dm−3, and for gallium-DDTC complex was from 1.0×10−9 to 2.1×10−7 mol dm−3.  相似文献   

4.
A supported liquid and a poly(vinyl chloride) (PVC)-based membrane selective for dodecylsulfate (DS) ion are described. The active element is a membrane containing a dissolved ion association complex of DS with cetylpyridinium (CP+) cation. The supported liquid membrane electrode (acetophenone as solvent) showed a Nernstian response towards the DS anion over the concentration range of sodium dodecylsulfate (SDS) from 8.3×10−3 to 1.0×10−6 mol dm−3 at 25 °C. The proposed electrode also showed a super-Nernstian potential response (108±2 mV decade−1) at low concentrations (1.0×10−9 to 1.0×10−6 mol dm−3). Moreover, this electrode showed good selectivity and precision (R.S.D.?2.0%), and was usable within the pH range 4.0-6.8. The proposed electrode revealed a lower limit of detection of 6.3×10−7 mol dm−3 and improved selectivity in comparison with the some previously reported DS ion selective electrodes. The isothermal temperature coefficient of this electrode amounted to −0.001 V °C−1. The liquid membrane electrode may find application in the direct determination of SDS by the standard addition method at pH 5.0, and in the physicochemical studies of surfactant solutions.  相似文献   

5.
Di J  Zhang F 《Talanta》2003,60(1):31-36
This paper described the determination of trace manganese using linear sweep voltammetry at a pretreatment glassy carbon electrode. The glassy carbon electrode pretreated by electrochemical method in the 0.1 mol l−1 NaOH solution greatly improved the electrode responsibility in the determination of manganese(II). The barrier to the detection of low manganese concentration was overcome by means of autocatalytic effect of manganese oxide deposited on the electrode in advance. Under the optimum experiments condition (0.04 mol l−1 NH3-NH4Cl buffer solution, pH 9.0), the linear range was 4×10−8 to 1×l0−6 mol l−1 Mn(II) for linear sweep voltammetry and 1×10−9 to 4×10−8 mol l−1 Mn(II) for convolution voltammetry. The relative standard deviation for 2×10−8 mol l−1 Mn(II) is 3.4%. The proposed method is simple, rapid, sensitive and selective. It had been applied to the determination of trace manganese in samples with satisfactory results.  相似文献   

6.
Yang P  Wei W  Tao C 《Analytica chimica acta》2007,585(2):331-336
Novel nano-silver coated multi-walled carbon nanotube composites were prepared and used to fabricate a modified electrode. The application of the nano-silver coated multi-walled carbon nanotube composites modified electrode for determination of trace thiocyanate is demonstrated for the first time. The influence of substrate, pH and interference of coexisting substances was investigated for response properties of the electrode. There was a linear relationship at the range 2.5 × 10−9 to 5 × 10−8 mol L−1 and 5 × 10−8 to 1 × 10−6 mol L−1 of thiocyanate with the decrement of anodic DPV peak currents. The limit of detection was 1 × 10−9 mol L−1(S/N = 3). The constructed electrode showed excellent reproducibility and stability. Actual urine and saliva samples of smoker and non-smoker were analyzed and satisfactory results were obtained. This method provides a new way to construct any electrode for biological and environmental analysis.  相似文献   

7.
Capillary zone electrophoresis (CZE) was employed for the determination of vincristine using electrochemical detection with a carbon fiber microdisk bundle electrode at a constant potential of 1.0 V versus saturated calomel electrode (SCE). The optimum conditions of separation and detection are 1.7×10−2 Na2HPO4− 3.2×10−3 mol/l NaH2PO4 (pH 7.5) for the buffer solution, 20 kV for the separation voltage. The limit of detection is 5.0×10−7 mol/l or 2.2 fmol (S/N=3) for the injection voltage of 5 kV and the injection time of 10 s. The recovery of the method is between 95 and 101% for the vincristine taken by human erythrocytes. The method was applied to investigate uptake and accumulation behavior of vincristine for human erythrocytes. The advantages of the method are the small sample volume of CZE and the high selectivity and sensitivity of electrochemical detection.  相似文献   

8.
The design and construction of a highly selective voltammetric sensor for metronidazole by using a molecularly imprinted polymer (MIP) as recognition element were introduced. A metronidazole selective MIP and a nonimprinted polymer (NIP) were synthesized and then incorporated in the carbon paste electrodes (CPEs). The sensor was applied for metronidazole determination using cathodic stripping voltammetric method. The MIP-CP electrode showed very high recognition ability in comparison to NIP-CPE. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. Two dynamic linear ranges of 5.64 × 10−5 to 2.63 × 10−3 mg L−1 and 2.63 × 10−3 to 7.69 × 10−2 mg L−1 were obtained. The detection limit of the sensor was calculated as 3.59 × 10−5 mg L−1. This sensor was used successfully for metronidazole determination in biological fluids.  相似文献   

9.
The use of selective pre-concentration and differential pulse anodic stripping voltammetry (DPASV) using a carbon paste electrode modified (CPEM) with spinel-type manganese oxide has been proposed for the determination of lithium ions content in natural waters. The new procedure is based on the effective pre-concentration of lithium ions on the electrode surface containing spinel-type Mn(IV) oxide with the reduction of Mn(IV) to Mn(III) and consequently the lithium ions intercalation (insertion) into the spinel structure. The best DPASV response was reached for an electrode composition of 25% (m/m) spinel-type MnO2 in the paste, 0.1 mol l−1 tris(hydroxymethyl)aminomethane (TRIS) buffer solution of pH 8.3, scan rate of 5 mV s−1, accumulation potential of 0.3 V versus saturated calomel reference electrode (SCE), pre-concentration time of 30 s and potential pulse amplitude of 50 mV. In these experimental conditions, the proposed methodology responds to lithium ions in the concentration range of 2.8×10−6 to 2.0×10−3 mol l−1 with a detection limit of 5.6×10−7 mol l−1. The determination of the lithium ions content in different samples of natural waters samples using the proposed methodology and atomic absorption spectrophotometry are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

10.
Tian L  Liu L  Chen L  Lu N  Xu H 《Talanta》2005,66(1):130-135
A vanadium oxide-modified glassy carbon electrode was simply and conveniently fabricated by casting vanadium tri(isoproxide) oxide (VO(OC3H7)3) and poly(propylene carbonate) (PPC) onto the glassy carbon electrode surface. The electrochemical properties of iodide at the VO(OC3H7)3-PPC film-modified glassy carbon electrode were investigated by cyclic voltammetry, and an anodic peak was observed at approximately +0.71 V (vs. SCE). Based on this, a sensitive and convenient electrochemical method was proposed for the determination of iodide. Flow injection amperometry (FIA) exhibited a good linear relationship with the concentration of iodide in the range of 5 × 10−7 mol L−1 and 1 × 10−3 mol L−1, and the detection limit was 1 × 10−7 mol L−1. Quantitative recovery of iodide in synthetic samples has been obtained and the interferences from different cations and anions have been studied. The method has been successfully applied to the determination of iodide in dry edible seaweed. The concentrations of iodide measured by this method are in good agreement with those obtained by spectrophotometric method.  相似文献   

11.
Titanium phosphate grafted on the surface of silica gel (devoted briefly as Si-TiPH) was synthesized and used as bulk modifier to fabricate a renewable three-dimensional chemically modified electrode. The Si-TiPH bulk modified carbon paste electrode was used for the selective determination of dopamine (DA) in the presence of ascorbic acid (AA). The modified electrode offers an excellent and stable response for the determination of DA in the presence of AA. The differential pulse voltammetry peak current was found to be linear with the DA concentration in the range 2 × 10−7 to 1 × 10−6 and 2 × 10−6 to 6 × 10−5 mol L−1. The detection limit of the proposed method in the presence of 2.0 × 10−5 M of AA was found to be 4.3 × 10−8 mol L−1 for DA determination. The proposed method was successfully applied for the determination of DA in injections.  相似文献   

12.
In this research, new electrodes were prepared by incorporating a new calix[4]arene derivative into a plasticized poly(vinyl chloride) matrix. Calibration plots with Nernstian slopes (29.9 ± 1.1 mV/decade) for vanadyl ion were observed over a linear range of about four decades of concentration (1.0 × 10−5 to 1.0 × 10−1 mol dm−3, at 25 °C). This electrode revealed a lower limit of detection of 3.9 × 10−6 mol dm−3. Conductometric data showed the relatively strong interaction between calix[4]arene and vanadyl ions. The results show that this electrode can be used in acetonitril and methanol media until 10% (v/v) concentration without interference. It has a short response time and can be used for more than two months without any considerable divergence in the potentials. The influence of membrane composition, the pH of the test solution, and the interfering ions on the electrode performance was investigated. The effect of temperature on the electrode response showed that the temperature higher than 50 °C deteriorates the electrode performance. The isothermal temperature coefficient of this electrode amounted to 0.0015 V °C−1. The results of application show that the electrode can be used successfully in present Cr3+ and Fe3+.  相似文献   

13.
Multi-walled carbon nanotube decorated with silver nanoparticles (AgNPs-MWCNT) is used as an effective strategy for modification of the surface of pyrolytic graphite electrode (PGE). This modification procedure improved colloidal dispersion of the decorated MWCNTs in water, affording uniform and stable thin films for altering the surface properties of the working electrode. Robust electrode for sensing applications is obtained in a simple solvent evaporation process. The electrochemical behavior of sumatriptan (Sum) at the bare PGE and AgNPs-MWCNT modified PGE is investigated. The results indicate that the AgNPs-MWCNT modified PGE significantly enhanced the oxidation peak current of Sum. A remarkable enhancement in microscopic area of the electrode together with strong adsorption of Sum on the surface of the modified electrode resulted in a considerable increase in the peak current of Sum. Experimental parameters, such as scan rate, pH, accumulation conditions and amount of the modifier used on the PGE surface are optimized by monitoring the CV responses toward Sum. It is found that a maximum current response can be obtained at pH 7.4 after accumulation at open circuit for 150 s. Further experiments demonstrated that the oxidative peak currents increased linearly with Sum concentration in the range of 8.0 × 10−8-1.0 × 10−4 mol L−1 with a detection limit of 4.0 × 10−8 mol L−1. The modified electrode showed high sensitivity, selectivity, long-term stability and remarkable voltammetric reproducibility in response to Sum. These excellent properties make the prepared sensor suitable for the analysis in pharmaceutical and clinical preparations. The modified electrode was successfully applied for the accurate determination of trace amounts of Sum in pharmaceutical preparations.  相似文献   

14.
An amperometric nicotine inhibition biosensor has been substantially simplified and used for determination of nicotine in tobacco sample. Besides the use of single enzyme choline oxidase to replace bienzyme, the use of 1,4-benzoquinone as an electron mediator makes it possible to avoid the use of oxygen or hydrogen peroxide sensor as the internal transducer. Choline oxidase was immobilized on the carbon paste electrode through cross-linking with bovine serum albumin (BSA) by glutaraldehyde. In the presence of choline oxidase and its endogenous cofactor flavin-ademine dinneleotide (FAD), choline was oxidized into betaine while FAD was reduced to FADH2 which subsequently reduced 1,4-benzoquinone into hydroquinone. The later was finally oxidized at a relatively low potential of +450 mV versus saturated calomel electrode (SCE). Nicotine inhibits the activity of enzyme with an effect of decreasing of oxidation current. The experimental conditions were optimized. The electrode has a linear response to choline within 1.25×10−4 to 1.25×10−3 mol l−1. The nicotine measurements were carried out in 0.067 mol l−1phosphate buffer of pH 7.4 at an applied potential of 450 mV versus SCE. The electrode provided a linear response to nicotine over a concentration range of 2.0×10−5 to 9.2×10−4 mol l−1 with a detection limit of 1.0×10−5 mol l−1. The system was applied to the determination of nicotine in tobacco samples.  相似文献   

15.
We report about the use of carbon paste electrode modified with kaolinite for analytical detection of trace lead(II) in domestic water by differential pulse voltammetry. Kaolinite clay was modified with tripolyphosphate (TPP) by impregnation method. The results show that TPP in kaolinite clay plays an important role in the accumulation process of Pb(II) on the modified electrode surface. The electroanalytical procedure for determination of Pb(II) comprised two steps: chemical accumulation of the analyte under open-circuit conditions, followed by electrochemical detection of the pre-concentrated species using differential pulse voltammetry. The analytical performance of this system has been explored by studying the effects of preconcentration time, carbon paste composition, pH, supporting electrolyte concentration, as well as interferences due to other ions. The calculated detection limit based on the variability of a blank solution (3sb criterion) for 10 measurements was 8.4 × 10−8 mol L−1, and the sensitivity determined from the slope of the calibration graph was 0.910 mol L−1. The reproducibility (RSD) for five replicate measurements at 1.0 mg L−1 lead level was 1.6%. The results indicate that this electrode is sensitive and effective for the determination of Pb2+.  相似文献   

16.
An adsorptive stripping voltammetric procedure for the determination of U(VI) at an in situ plated lead film electrode is described. The U(VI) complex with cupferron was accumulated from an acetate buffer solution of pH 4.2 at the potential −0.65 V. The measurements were carried out from undeaerated solutions. The calibration graph for an accumulation time of 180 s was linear from 5 × 10−10 to 2 × 10−8 mol L−1. The detection limit was 2 × 10−10 mol L−1, the relative standard deviation for 2 × 10−8 mol L−1 U(VI) was 4.3%. The proposed procedure was validated in the course of U(VI) determination in water certified reference materials.  相似文献   

17.
The thermal lens optical scheme-design was optimised for microscopic measurements in microchannels. The efficient pathlength of the sample, irradiated volume, and the diameter of the thermal lens were estimated. Experimental time curves of development of the thermal lens and periodical oscillations of the signal due to convectional heat transfer are in good agreement with the theoretically expected behaviour. Noise sources (laser noises, instrumental flicker noise, convection, and flow noise) were studied. The possible effect of probe laser power on transient and steady-state thermal lens measurements were estimated. The effect of solvent absorption on the performance characteristics is shown. Under the optimum optical scheme-design, the limits of detection of ferroin and Sunset Yellow FCF at 488.0 nm are 1×10−8 and 4×10−9 mol dm−3, respectively (corresponding quantities in the detection volume are 3×10−21 and 1×10−21 mol). The total linear calibration range is n×10−8 to n×10−4 mol dm−3, the repeatability R.S.D. for this range is 3-7%. The optimised instrument was also used for the determination of characteristic rate constants of formation and dissociation of ferroin at the level of n × 10−8 mol dm−3. Some analytical applications are discussed.  相似文献   

18.
Fei Wang  Xiaohan Wei  Shusheng Zhang 《Talanta》2010,80(3):1198-1204
The π-A isotherms and UV-vis spectra of the transferred films suggested that the monolayer of p-tert-butylthiacalix[4]arene can coordinate with Hg2+ at the air-water surface. From these observations, a glassy carbon electrode coated with Langmuir-Blodgett film of p-tert-butylthiacalix[4] arene as a new voltammetric sensor is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode and modified glassy carbon electrode using direct coating method, the Langmuir-Blodgett film-modified electrode can greatly improve the measuring sensitivity of Hg2+. Under the selected conditions, the Langmuir-Blodgett film-modified electrode in 0.1 mol L−1 H2SO4 + 0.01 mol L−1 KCl solution shows a linear voltammetric response for Hg2+ in the range of 5.0 × 10−10 to 1.5 × 10−7 mol L−1, with a detection limit of 2.0 × 10−10 mol L−1. The proposed method was also applied to determine Hg2+ in water samples (tap, lake and river water). In addition, the fabricated electrode exhibited a distinct advantage of simple preparation, non-toxicity, good reproducibility and good stability.  相似文献   

19.
An in situ plated lead film electrode has been applied for adsorptive stripping voltammetric determination of trace concentrations of molybdenum in the presence of Alizarin S. The procedure is based on the preconcentration of the molybdenum-Alizarin S complex at an in situ plated lead film electrode held at −0.6 V (versus Ag/AgCl), followed by a negatively sweeping square wave voltammetric scan. The peak current is proportional to the concentration of molybdenum over the range 2 × 10−9 to 5 × 10−8 mol L−1, with a 3σ detection limit of 9 × 10−10 mol L−1 with an accumulation time of 60 s. The measurements were carried out from underaerated solutions. The proposed procedure was validated in the course of Mo(VI) determination in water certified reference materials.  相似文献   

20.
El-Desoky HS  Ghoneim MM 《Talanta》2011,84(1):223-234
Silymarin is one of the most powerful natural substances that have the ability to protect and rebuild the liver cells damaged by alcohol and other toxic substances. Silymarin showed two irreversible anodic peaks in buffered solutions (pH 2.5-8.0) at either the bare carbon paste electrode or the montmorillonite-Ca modified carbon paste one. These two peaks have been attributed to oxidation of the two phenolic OH groups at positions C-20 and C-7 of silymarin molecule. A square-wave adsorptive anodic stripping voltammetry method was optimized for determination of silymarin utilizing the bare and the modified carbon paste electrodes. The method was fully validated and successfully applied for the determination of silymarin in commercial formulations and human serum without prior extraction utilizing both carbon paste electrodes. Limits of quantitation of 1 × 10−7 and 7 × 10−9 mol L−1 silymarin have been achieved in bulk form or in formulations while 2 × 10−7 and 8 × 10−9 mol L−1 silymarin were achieved in spiked human serum utilizing the bare carbon paste electrode and the modified one, respectively. The two electrodes exhibited excellent selectivity towards silymarin even in the presence of 102to 103-fold excess of its co-formulated drugs, common excipients, and common metal ions. The pharmacokinetic parameters of silymarin in plasma of healthy human volunteers were estimated following the administration of a single oral dose of 120 mg silymarin utilizing the modified carbon paste electrode. The estimated pharmacokinetic parameters were favorably compared with those reported in literature.  相似文献   