首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
A novel kinetic chemiluminescent method using the stopped-flow mixing technique has been investigated for the rapid and sensitive determination of citrate and pyruvate. The method is based on a tris(2,2′-bipyridiyl)ruthenium(III) (Ru(bpy)33+) chemiluminescence (CL) reaction. Ru(bpy)33+ was generated in the mixing chamber by oxidising tris(2,2′-bipyridyl)ruthenium(II) with cerium(IV). After selecting the best operating parameters, calibration graphs were obtained over the concentration ranges 0.38-38 μg ml−1 and 8.7-1300 ng ml−1 for citrate and pyruvate, respectively. The limits of detection were 0.1 μg ml−1 for citrate and 0.3 ng ml−1 for pyruvate. Based on the differential rate of the chemiluminescent reaction corresponding to citrate and pyruvate, a very simple kinetic procedure was developed for the simultaneous determination of both compounds. Mixtures of citrate and pyruvate in ratios between 15:1 and 1.5:1 were satisfactorily resolved. The proposed method was successfully applied to the determination of citrate in pharmaceutical formulations, pyruvate in animal blood serum and both compounds in human urine.  相似文献   

2.
A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the oxidation of methylene blue (MB) with hydrogen peroxide in a strongly acidic solution. Large amounts of chloride could enhance the sensitivity of the method as an activator. The decolorisation of the blue color of MB was used for the spectrophotometric determination of bromide at 746 nm. A stopped-flow approach was used to improve the sensitivity of the measurement and provide good linearity of the calibration over the range of 0-3.2 μg ml−1 of bromide. The relative standard deviation was 0.74% for the determination of 2.4 μg ml−1 bromide (n = 5). The detection limit (3σ) was 0.1 μg ml−1 with a sampling frequency of 12 h−1. The influence of potential interfering ions was studied. The proposed method was applied to the determination of bromide in seawater samples and provided satisfactory results.  相似文献   

3.
Highly sensitive catalytic determination of molybdenum   总被引:1,自引:0,他引:1  
A novel, highly sensitive, selective, and simple kinetic method was developed for the determination of Mo(VI) based on its catalytic effect on the oxidation of 1-amino-2-naphthol-4-sulfonic acid (ANSA) with H2O2. The reaction was followed spectrophotometrically by tracing the oxidized product at 465 nm after 30 min of mixing the reagents. The optimum reaction conditions were: 10 mmol l−1 ANSA, 50 mmol l−1 H2O2, 100 mmol l−1 acetate buffer of pH 5.0 ± 0.05 and at 40 °C. Addition of 200 μg ml−1 diethylenetriaminepentaacetic acid (DTPA) conferred high selectivity for the proposed method. Following the recommended procedure, Mo(VI) could be determined with a linear calibration graph up to 2.5 ng ml−1 and a detection limit, based on the 3Sb-criterion, of 0.027 ng ml−1. The unique sensitivity and selectivity of the implemented method allowed its direct application to the determination of Mo(VI) in natural and industrial waste water. The method was validated by comparison with the standard ETAAS method. Moreover, published catalytic-spectrophotometric methods for the determination of molybdenum were reviewed.  相似文献   

4.

Background  

Organophosphorous pesticides are the most popular pesticides used in agriculture. As acetylcholinesterase inhibitors, organophosphorous pesticides are toxic organic chemicals. The control and detection of organophosphorous pesticide residue in food, water, and environment therefore plays a very important role in maintaining physical health. A sensitive, rapid, simple chemiluminescence(CL) method has been developed for the determination of quinalphos based on the reaction of quinalphos with luminol-H2O2 in an alkaline medium. The method has been applied to detection of quinalphos in vegetable samples with satisfactory results.  相似文献   

5.
A simple and rapid method for the determination of DNA, involving the interaction between a surfactant, a long-wavelength fluorophor (LWF) and the nucleic acid, is presented. Different chemical systems based on the local effective charge of the surfactant/LWF system with DNA were tested, choosing cetyltrimethyl ammonium bromide (CTAB) and indocyanine green (ICG) for the development of the method. The fluorescence of ICG increases in the presence of CTAB, but it rapidly decreases in the presence of deoxyribonucleic acid. The initial reaction-rate (v0) and signal at a prefixed-time (ΔIF20) are monitored at 780 and 802 nm as excitation and emission wavelengths, respectively, using stopped-flow mixing technique, which makes the method applicable to automate routine analysis. Each measurement was obtained in about 30 s, being the integration time 0.1 s. The dynamic range of the calibration graph was 10-1500 ng mL−1, with a detection limit of 5 ng mL−1. The precision of the method, expressed as relative standard deviation, ranged between 2.1% and 4.5%. After a sample treatment consisting on a conventional extraction, the method was applied to the determination of DNA in several samples from different biological materials.  相似文献   

6.
A novel alternative for the simultaneous determination of compounds with similar structure is described, using the whole chemiluminescence-time profiles, acquired by the stopped-flow technique, in combination with mathematical treatments of multivariate calibration. The proposed method is based on the chemiluminescent oxidation of morphine and naloxone by their reaction with potassium permanganate in an acidic medium, using formaldehyde as co-factor. The whole chemiluminescence-time profiles, acquired using the stopped-flow technique in a continuous-flow system, allowed the use of the time-resolved chemiluminescence (CL) data in combination with multivariate calibration techniques, as partial least squares (PLS), for the quantitative determination of both opiate narcotics in binary mixtures.In order to achieve overcoat the additivity of the CL profiles and beside to obtain CL profiles for each drug the most separated as possible in the time, the optimum chemical conditions for the CL emission were investigated. The effect of common emission enhancers on the CL emission obtained in the oxidation reaction of these compounds in different acidic media was studied. The parameters selected were sulphuric acid 1.0 mol L−1, permanganate 0.2 mmol L−1 and formaldehyde 0.8 mol L−1. A calibration set of standard samples was designed by combination of a factorial design, with three levels for each factor and a central composite design. Finally, with the aim of validating the chemometric proposed method, a prediction set of binary samples was prepared. Using the multivariate calibration method proposed, the analytes were determined in synthetic samples, obtaining recoveries of 97-109%.  相似文献   

7.
Two vibrational spectrometry-based methodologies were developed for Metamitron determination in pesticide formulations. Fourier transform-middle infrared (FT-MIR) procedure was based on the extraction of Metamitron by CHCl3 and latter determination by peak area measurement between 1556 and 1533 cm−1, corrected with a two points baseline established from 1572 to 1514 cm−1. Fourier transform-near infrared (FT-NIR) determination was made after the extraction of Metamitron in acetonitrile and measuring the peak area between 6434 and 6394 cm−1 corrected using a two points baseline defined between 6555 and 6228 cm−1. Repeatability, as relative standard deviation, of 5 independent measurements at mg g−1 concentration level, of 0.16% and 0.07% for MIR and NIR and a limit of detection of 0.03 and 0.004 mg g−1 were obtained for MIR and NIR, respectively.NIR determination provides a sample frequency of 120 h−1, higher than that found by MIR and liquid chromatographic methods (60 and 15 h−1, respectively). On the other hand, the NIR method reduces the solvent consumption and waste generation, to only 1 ml acetonitrile per sample as compared with 3.4 ml chloroform required for the MIR determination and 60 ml acetonitrile used in the chromatographic reference procedure. So, vibrational procedures can be considered serious alternatives to long and time consuming chromatographic methods usually recommended for quality control of commercially available pesticide formulations.  相似文献   

8.
A simple and rapid homogeneous enzyme immunoassay involving the use of the malic dehydrogenase enzyme and a long-wavelength fluorophor, the oxazine Cresyl Violet, is proposed for the determination of the antibiotic amikacin in water samples. An enzymatic tracer has been synthesized by covalent binding of amikacin to malic dehydrogenase via a carbodiimide derivative. Free tracer catalyses the reaction between Cresyl Violet and malic acid giving rise to a decrease in the fluorescence of the fluorophor. Kinetic curves for this reaction have been monitored at λex 585 and λem 624 nm using the stopped-flow mixing technique, being the initial rate measured in only 2-3 s. The dynamic range of the method is 1-15 ng mL−1 and the detection limit is 0.3 ng mL−1, using aqueous standard solutions or water samples. The precision, obtained at 1 and 5 ng mL−1 and expressed as relative standard deviation, was 6.0 and 9.6%, respectively. The method has been applied to the analysis of drinking, river and wastewater samples. The sample pre-treatment involved a solid-phase extraction step for the clean-up of the samples. A recovery study was carried out to validate the method, being the values obtained in the range 80-114%, with a mean value of 96.7%.  相似文献   

9.
A new method is proposed for the chemiluminescent determination of the pesticide 3-indolyl acetic acid by means of an flow injection analysis system. The chemiluminescence emission is obtained by oxidation of the analyte with Ce (IV) in nitric acid and presence of β-cyclodextrine.The continuous-flow method allows the determination of 159 samples h−1 of 3-indolyl acetic acid in an interval of concentrations over the range 0.5-15.0 mg l−1. The limit of detection was 0.1 μg l−1 and the R.S.D. (n, 17) at 2.0 mg l−1 of the pesticide level was 2.7%. The method was applied to water samples.  相似文献   

10.
Xu J  Wu X  Yan W  Cai R  Lin Z 《Talanta》2006,70(2):323-329
In this work, a new kinetic method was proposed for quantification phenoxyl radicals generated in enzyme reaction. Instead of direct detecting the spectral signals of phenoxyl radicals, a molecular probe, the reduced form of nicotinamide adenine dinucleotide (NADH), was employed to indicate the formation of phenoxyl free radicals. It was found that the reactions of NADH and phenoxyl radicals are very fast, but can be followed by using stopped-flow fast scanning spectrophotometric technique. The initial rate of accelerated-oxidation of NADH represents the reactivity of phenoxyl free radical, which is proportional in a certain range to the initial concentration of the parent chlorophenols of the radicals. With this method, the phenoxyl radicals generated in oxidation reaction of chlorophenols (2-CP; 4-CP; 2,4-DCP; 2,4,6-TCP and 2,3,4,6-Tetra-CP) with hydrogen peroxide, catalyzed by horseradish peroxidase, were investigated. The method is highly sensitive. Phenoxyl radicals generated from as low as 1 × 10−8 M 2,4-DCP, for example, can be readily detected with the proposed method. The results show that the reactivity of various phenoxyl radicals are in the following order: 2,4-DCP > 4-CP > 2-CP > 2,4,6-TCP > 2,3,4,6-Tetra-CP. A mechanism is proposed to explain the possible pathway of the probe reaction. The feasibility of this method was assessed by the determination of enzymatic generation of phenoxyl radicals in lake water samples.  相似文献   

11.
Fan J  Wang A  Feng S  Wang J 《Talanta》2005,66(1):236-243
A new sequential injection spectrophotometric method was proposed for the determination of metoclopramide and tetracaine hydrochloride. The method was based on the detection of an unstable red intermediate compound resulting from the reaction of metoclopramide or tetracaine hydrochloride with potassium dichromate, in the presence of sodium oxalate, in sulfuric acid solution. The related reaction mechanisms of this new method have been studied. The experimental conditions were optimized for the stopped-flow and continuous-flow sequential injection models. For continuous flow, the linear range for determination of metoclopramide, the detection limit and the sampling frequency were 13-130 μg ml−1, 9.4 μg ml−1 and 40 samples per hour, respectively. For stopped flow, they were 3-42 μg ml−1, 1.0 μg ml−1 and 18 h−1, respectively. Adopting the continuous-flow model for tetracaine hydrochloride, the linear range was 25-300 μg ml−1, and the detection limit was 18.0 μg ml−1 with sampling frequency of 40 h−1. This method has been used to determine metoclopramide and tetracaine hydrochloride in pharmaceutical preparations, and the results are compared with those determined by the pharmacopoeia method. Statistical analysis reveals that there was no evidence of significant difference between the methods.  相似文献   

12.
A novel and high throughput chemiluminescence (CL) method for determination of chemical oxygen demand (COD) in water sample was originally developed based on potassium permanganate-glutaraldehyde CL system. With this method, dissolved organic matter in water samples was digested by excess acid potassium permanganate, the reacted mixture solutions containing surplus KMnO4 were added in wells of a 96-well plate, followed by injection of glutaraldehyde in the wells, and CL was then produced along with the reaction of the added glutaraldehyde with the surplus KMnO4 and detected by a photomultiplier tube (PMT). The difference (ΔI) between the CL intensity for distilled water and that for sample water was proportional to the COD value of water sample. The calibration graph was linear in the range of 0.16-19.24 mg L−1 with a detection limit of 0.1 mg L−1. A complete analysis could be performed in 40 min including digestion and detection, giving a very high throughput of 3 × 96 samples in about 60 min. Compared with the conventional methods, this method is simple and sensitive and consumes very limited and cheap reagents. Owing to its rapid, automatic, high throughput and low cost characteristics, the presented CL method has been applied successfully to the determination of COD in real water samples (n = 32) with satisfactory results.  相似文献   

13.
A very sensitive flow injection method with spectrophotometric detection has been developed for the on-line determination of copper in natural waters. The method exhibits a limit of detection three times lower than the most sensitive direct spectrophotometric method previously described and then allows the direct and simple in situ determination of copper in most natural waters.The method was based on the measurement of the absorbance of the coloured complex formed by copper with the chromogenic reagent di-2-pyridyl ketone benzoylhydrazone (dPKBH) in an alkaline medium. This complex presents stoichiometry 1:2 (Cu:dPKBH), and exhibits maximum absorbance at 370 nm. The manifold used was very simple, and consisted of two channels. The first one contained the sample while the second one contained the colorimetric reagent (3.3×10−4 M dPKBH in 10% ethanol), in a 1.6×10−2 M phosphate buffer solution at pH 8. The performance of the system was optimised by using both univariate and modified simplex methodologies. When modified simplex was used, the best signal was obtained for a sample injection volume of 529 μl, a reaction coil length of 1.29 m, and a reagent flow rate of 4.8 ml min−1. Under optimum conditions, the response was linear up to 3 mg l−1 copper, the equation of the straight line being y=0.314x+5.2×10−4 (r2=0.998). The method allowed a sampling frequency of 40 samples per hour and exhibited a precision of 2.11% (as R.S.D., n=11). The limit of detection was 4.6 μg l−1 (calculated as 3sb/m, where sb is the standard deviation of the y-intercept and m represents the slope of the straight line), and was therefore more sensitive than all the direct continuous methods reported previously.The method was successfully applied to the analysis of real water samples, with an average relative error of 5.32%.  相似文献   

14.
Spectrophotometric flow injection methods were developed for the individual determination of nitrite or nitrate, and for the simultaneous determination of nitrite and nitrate, in soil samples. Nitrite was determined directly using a modified version of the Griess-Ilosvay diazo-coupling reaction, measuring at 543 nm the absorbance of the azo-dye complex formed. Simultaneous nitrite and nitrate determinations were based on on-line nitrate reduction in a micro column containing copperised cadmium. A single chromogenic reagent containing all the necessary reactants was used in both methods. For determinations, the chemical and instrumental variables were optimised by univariate analysis and simplex chemometric method. The optimised conditions gave a linear calibration range between 0.05 and 1.6 µg m L− 1 for N-NO2 and between 0.05 and 7.0 µg m L− 1 for N-NO3. The detection limits for nitrite and nitrate were 22 µg L− 1 and 44 µg L− 1 respectively. The proposed methods allowed up to 35-40 samples per hour to be analysed with good precision. The simultaneous method was successfully used for the determination of nitrite and nitrate in soil samples (the results obtained were validated against those obtained by reference methods). The proposed methods are simpler and faster than conventional methods and could be routinely used in environmental monitoring laboratories.  相似文献   

15.
The simultaneous determination of levodopa (LD) and propranolol (PRO) using fluorescence spectrometric technique is described. The method involves measuring the natural fluorescence of these drugs in the micellar media of sodium dodecyl sulfate (SDS) using principal component analysis-feed-forward neural networks (PC-FFNNs). Experimental conditions such as effect of pH and SDS concentration were optimized. Under the optimum conditions, the linear determination ranges of LD and PRO are 2.0 × 10−8 to 1.0 × 10−5 mol L−1 and 3.6 × 10−9 to 1.8 × 10−6 mol L−1, respectively. A set of synthetic binary mixtures of LD and PRO was prepared and their concentrations were predicted by the proposed method. Satisfactory results were obtained by the combination of fluorescence technique with chemometrics methods. The method was successfully applied to the determination of LD and PRO in tap water and in urine samples.  相似文献   

16.
In this work a novel method for the fast monitoring of lidocaine in flow-injection systems has been developed. The fast Fourier transform continuous cyclic voltammetry (FFTCV) at gold microelectrode in flowing solution system was used for determination of lidocaine in its pharmaceutical formulation. The presented technique was very simple, precise, accurate, time saving and economical, compared with all of the previously reported methods. The recommended technique demonstrated some advantages over other reported methods. Firstly, there was no need for the oxygen removal from the test solution. Secondly, a picomolar detection limit was achieved, and additionally, the method was fast enough for the determination of any such compound, in a wide variety of chromatographic methods. The method was linear across the concentration range of 240-1.1 × 105 pg mL−1 (r = 0.996) with a limit of detection and quantitation 117.3 and 240 pg mL−1, respectively. As a conclusion this system offers the requisite accuracy, sensitivity, precision and selectivity to assay lidocaine in injections.  相似文献   

17.
The partial least squares (PLS-1) calibration model based on spectrophotometric measurement, for the simultaneous determination of CN and SCN ions is described. The method is based on the difference in the rate of the reaction between CN and SCN ions with chloramine-T in a pH 4.0 buffer solution and at 30 °C. The produced cyanogen chloride (CNCl) reacts with pyridine and the product condenses with barbituric acid and forms a final colored product. The absorption kinetic profiles of the solutions were monitored by measuring absorbance at 578 nm in the time range 20-180 s after initiation of the reaction with 2 s intervals. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 31 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 10.0-900.0 and 50.0-1200.0 ng mL−1 for CN and SCN ions, respectively. The proposed method was successfully applied to the simultaneous determination of cyanide and thiocyanate in water samples.  相似文献   

18.
The chemiluminescent behaviour of captopril when reacted with a common oxidant, potassium permanganate in different acidic media is described, using the stopped-flow technique in a continuous-flow system. A 22 bit analogue-to-digital converter that acquires analogue signals at −10 and +10 V and allows the power supply to the peristaltic pump to be interrupted is used in the time-resolved chemiluminescence manifold to ensure rapid, efficient mixing of chemiluminescent reagent and sample immediately before reaching the detector; this results in high precision and detectability, particularly with fast, short-lived emissions.The optimum chemical conditions for the chemiluminescence emission were investigated. It was found that a weak CL emission was emitted during the oxidation of this drug with potassium permanganate in acidic solution. The effect of common emission enhancers such as formic acid, formaldehyde, glutaraldehyde, acetaldehyde, quinine, fluorescein, rhodamine B and rhodamine 6G was studied. The parameters selected were 4.0 mol L−1 sulphuric acid, 0.25 mmol L−1 permanganate and 0.75 mol L−1 formaldehyde.Four quantitative parameters adjustable via software settings, two of them typically kinetic parameters, such as rate of the light-development reaction and rate of the light-decay reaction, and the other conventional parameters, such as maximum emission intensity and total emission area, were used to obtain linear calibration graphs with each measurement parameter. The detection limits ranged from 0.011 to 0.026 μg mL−1 and R.S.D. values (n = 10) of 1.21-3.93 at a 0.50 μg mL−1 and 2.01-3.41 at a 1.60 μg mL−1 concentration levels were obtained. The method was satisfactorily applied to the determination of captopril in pharmaceutical preparations.  相似文献   

19.
The quantitative determination of boldine alkaloid in boldo leaf extracts by employing cyclic voltammetry, at a liquid/liquid interface as well as the validation of this methodology against the reference method, high performance liquid chromatography (HPLC), are reported in the present paper. The voltammetric analysis was performed successfully and economically using two kinds of liquid/liquid interfaces: water/1,2-dicholoroethane and water/PVC (polyvinyl chloride)-gelled 1,2-dichloroethane. Linear calibration curves in the concentration range of 1.04 × 10−5 mol L−1 to 5.19 × 10−4 mol L−1 were obtained with a detection limit equal to (6.1 ± 0.7) × 10−5 mol L−1 and the quantitative determination of this alkaloid, in complex matrixes such as boldo leaf extracts, by the electrochemical technique proposed was found to be equal to the values obtained using the standard HPLC method. The validation analysis of this methodology against HPLC demonstrated that accuracy, linearity, limit of detection (LOD), limit of quantification (LOQ), specificity and precision are acceptable. The electroanalytical technique proposed is economical and selective, involves simple equipment and can be applied for the quantitative determination of boldine alkaloid in complex matrixes such as leaf extracts without special drug separation. Moreover, cyclic voltammetry (CV) experiments applied at the liquid/liquid interface under different experimental conditions allowed us to study the transfer mechanism of boldine, and determine a value of pKaw = 6.90 for protonated boldine, from the variation of voltammetric peak current with pH.  相似文献   

20.
Conversion of nitrate into a nitro-phenol derivative by reaction with 2-methylphenol or 2,6-dimethylphenol allowed at least 100-fold enrichment of the derivative on Lichrolut EN polymeric cartridge, and it is stable for up to 1 month on the cartridge. The derivative could be eluted with ammonia-methanol mixture. This reaction for nitrate determination has permitted a choice of final measurement by UV-Vis spectrophotometry, liquid chromatography or gas chromatography-mass spectrometry when the limits of detection were 10, 6 and 3 μg l−1, respectively, and the calibration range 20 μg to 10 mg l−1 nitrate. The method has been validated by spiking natural water samples, when the recovery of nitrate was 98.5-108.4% (relative standard deviation 2.5-6.1%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏