首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories).  相似文献   

2.
The development of analytical techniques that enable the use of hair as an alternative matrix for the analysis of drugs of abuse is useful for confirming the exposure in a larger time window (weeks to months, depending on the length of the hair shaft). In the present study a methodology aimed at the simultaneous quantification of cocaine and morphine in human hair was developed and validated. After decontamination, hair samples (20?mg) were incubated with a mixture of methanol/hydrochloric acid (2:1) at 65?°C overnight (~16?h) in order to extract the drugs of the matrix. Purification was performed by solid-phase extraction using mixed-mode extraction cartridges. After derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide, blank, standards and samples were analyzed by gas chromatography/electron impact-mass spectrometry (GC-EI/MS). The method proved to be selective, as there were no interferences of endogenous compounds with the same retention time as cocaine, morphine and ethylmorphine (internal standard). The regression analysis for both analytes showed linearity in the range 0.25-10.00?ng/mg with correlation coefficients ranging from 0.9989 to 0.9991. The coefficients of variation oscillated between 0.83 and 14.60%. The limits of detection were 0.01 and 0.02?ng/mg, and the limits of quantification were 0.03 and 0.06?ng/mg for cocaine and morphine, respectively. The proposed GC-EI/MS method provided an accurate and simple assay with adequate precision and recovery for the quantification of cocaine and morphine in hair samples. The proof of applicability was performed in hair samples obtained from drug addicts enrolled in a Regional Detoxification Treatment Center. The importance of hair samples is highlighted, since positives results were obtained when urine immunoassay analyses were negative. Copyright ? 2012 John Wiley & Sons, Ltd.  相似文献   

3.
The detection of steroid residues in hair is a powerful strategy to demonstrate long-term administration of these growth promoters in meat production animals. A fast and reliable method was developed for monitoring anabolic steroids and their esters in hair. A 100 mg hair sample was converted into powder and extracted at 50 °C with methanol (sebum fraction). The remaining hair was digested with 1 M NaOH for further extraction of bound steroids. The two fractions were separately purified onto an aminopropyle solid-phase extraction column and onto a silica SPE cartridge. Steroids were detected either by gas chromatography-tandem mass spectrometry after silylation using N-methyl-N-(trimethylsilyl)-trifluoroacetamide/trimethyliodosilane/dithiothreitol or liquid chromatography-tandem mass spectrometry. This method was applied to hair samples collected over a three months period after treatment of three cows respectively with 17α-methyltestosterone, medroxyprogesterone acetate and 17β-estradiol-3-benzoate. The fixation kinetic into hair of the three steroids have been deeply examined and discussed; relation in-between concentration and distance from the injection site, influence of hair colour and sample treatment consequences have been discussed.  相似文献   

4.
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.  相似文献   

5.
头发中内源性类固醇激素的气相色谱-串联质谱分析   总被引:3,自引:1,他引:2  
沈敏  向平  沈保华  王萌烨 《色谱》2008,26(4):454-459
建立了建康人头发中内源性类固醇兴奋剂睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的气相色谱-串联质谱(GC-MS/MS)分析方法。头发经碱水解后,以乙醚提取,经衍生化后采用GC-MS/MS的多反应监测模式(MRM)分析。方法的线性关系良好,检出限达0.1~0.2 pg/mg;提取回收率为74.6%~104.5%;日内测定的准确度为90.1%~113.7%,日内及日间测定的精密度均小于17.5%。应用所建立的方法测定了80例中国健康人头发中睾酮、表睾酮、雄酮、苯胆烷醇酮和脱氢表雄酮的生理水平,为内源性类固醇兴奋剂滥用的判断提供了方法和基础数据。  相似文献   

6.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

7.
Over recent years, hair has become the ideal matrix for retrospective investigation of chronic abuse, including for tramadol. However, in order to exclude the possibility of external contamination, it is also important to quantify simultaneously its main metabolite, O‐desmethyltramadol (M1), which presence in hair reflects systemic exposure. In the present study a methodology aimed at the simultaneous quantification of tramadol and M1 in human hair was developed and validated for the first time. After decontamination of hair samples (60 mg), tramadol and M1 were extracted with methanol in an ultrasonic bath (~5 h). Purification was performed by solid‐phase extraction using mixed‐mode extraction cartridges. Subsequently to derivatization, analysis was performed by gas chromatography–electron impact/mass spectrometry (GC‐EI/MS). The method proved to be selective. The regression analysis for both analytes was shown to be linear in the range of 0.1–20.0 ng/mg with correlation coefficients of 0.9995 and 0.9997 for tramadol and M1, respectively. The coefficients of variation oscillated between 3.85 and 13.24%. The limits of detection were 0.03 and 0.02 ng/mg, and the lower limits of quantification were 0.08 and 0.06 ng/mg for tramadol and M1, respectively. The proof of applicability was performed in hair samples from six patients undergoing tramadol therapy. All samples were positive for tramadol and M1. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
Two new standard reference materials (SRM) for drugs of abuse in human hair have been developed. SRM 2379 consists of hair spiked with cocaine, benzoylecgonine, cocaethylene, phencyclidine, amphetamine, and methamphetamine. SRM 2380 consists of hair spiked with codeine, morphine, monoacetylmorphine, and tetrahydrocannabinol (THC). The SRMs were prepared by soaking the hair in a solution of the target analytes in water-dimethylsulfoxide. The concentration of each analyte was determined using two methods, one based upon gas chromatography/mass spectrometry (GC/MS) and one based upon liquid chromatography/mass spectrometry (LC/MS). Both methods used 0.1 M HCl for extraction of all the analytes from the hair, except for THC, which was extracted with 1 M NaOH. For isolation of the analytes from the extracts, the GC/MS-based methods used different clean-up procedures from those used for the LC/MS-based methods. The results from the two methods were in good agreement with mean differences for the analytes ranging from 4% to 16%. These materials will enable laboratories performing analyses of hair for drugs of abuse to test the accuracy of their methods.  相似文献   

9.
A simple procedure combining headspace solid-phase microextraction (HS-SPME) and gas chromatography–mass spectrometry (GC/MS) to detect and quantify amphetamines, ketamine, methadone, cocaine, cocaethylene and ∆9-tetrahydrocannabinol (THC) in hair is described. This procedure allows, in a single sample, even scant, analysis of drugs requiring different analytical conditions. A hair sample (10 mg) is washed and subjected to acidic hydrolysis. Then the HS-SPME is carried out (10 min at 90 °C) for amphetamines, ketamine, methadone, cocaine and cocaethylene. For derivatization of analytes, the fibre is introduced into the headspace of another closed vial containing acetic anhydride. After a chromatographic run, an alkaline hydrolysis for THC analysis is carried out in the same vial containing the hair sample previously used. For adsorption, the solid-phase microextraction needle is inserted into the headspace of the vial and the fibre is exposed for 30 min at 150 °C. For derivatization of analytes, the fibre is introduced into the headspace of another closed vial containing N-methyl-N-(trimethylsilyl)trifluoroacetamide. The GC/MS parameters were the same for both chromatographic runs. The linearity was proved to be between 0.01 and 10.00 ng/mg. The repeatability (intra- and interday precision) was below 10% as the coefficient of variation for all compounds. The accuracy, as the relative recovery, was 96.2–103.5% (spiked samples) and 88.6–101.7% (quality control sample). The limit of detection ranged from 0.01 to 0.12 ng/mg, and the limit of quantification ranged from 0.02 to 0.37 ng/mg. Application of the procedure to real hair samples is described. To the best of our knowledge, the proposed procedure combining HS-SPME and GC/MS is the first one be to successfully applied to the simultaneous determination of most of the common recreational drugs, including THC, in a single hair sample.  相似文献   

10.
A sensitive, specific and selective multianalyte GC–MS/MS method has been developed for the determination of 11 anabolic hormones in bovine urine. After adjusting the urine pH to 4.8, the samples were spiked with deuterated internal standards and submitted to enzymatic hydrolysis with β-glucuronidase/arylsulfatase. Hormones were eluted with methanol through a C18 solid phase cartridge and submitted to a liquid–liquid extraction. Analytes were derivatized by adding N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane and GC–MS data were obtained in the positive electron impact tandem mass mode. Under these conditions, no matrix effects were observed and limit of detection values were in the range of 0.005 ng/mL (diethylstilbestrol) to 0.38 ng/mL (17α-methyltestosterone and 17α-ethynylestradiol). Recoveries from 81% (α-zeranol) to 149% (17α-methyltestosterone) were found under the selected conditions. These results were better than those found using heptafluorobutyric anhydride (HFBA) as derivative reagent and those measured in full scan and selective ion monitoring modes.  相似文献   

11.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples.  相似文献   

12.
The change of chemical structure of cocaine in the presence of hydrogen peroxide, a main component of hair dye and decolorant treatments, was studied. High-performance liquid chromatography/mass spectrometry (LC/MS) was used for the separation and identification of cocaine derivatives. After a mixture of cocaine and hydrogen peroxide solutions was incubated at 39 degrees C (this temperature is commonly used when the hair is treated with hair dye or decolorant) for 24 h, six reaction products were detected by LC/MS. Two of them were ecgonine methyl ester and benzoylecgonine, which are metabolites of cocaine. The other reaction products were assumed to be ortho-, meta- and para-hydroxycocaines and dihydroxycocaine, in each of which the benzene ring was hydroxylated by the reaction. These five reaction products (except for dihydroxycocaine) were found immediately after mixing cocaine and hydrogen peroxide. Therefore, the above reaction products might be present in the hair of cocaine users that had treated their hair with hair dye or decolorant.  相似文献   

13.
Complete GC–SIM/MS separation and identification of 19 steroids (including several steroid isomers) in a male urine sample, as their per-trimethylsilyl ethers, is described. Trimethylsilylation of their functional groups (hydroxyl and carbonyl) was achieved by a rapid, simplified and one-step derivatization method, using N -methyl- N -trimethylsilyl-2,2,2,-trifluoroacetamide as the silylating agent and the solvent as well, along with catalytic amounts of trimethylsilyl iodide and dithioerythritol. Furthermore, a GC/MS method for the analysis of a synthetic mixture of underivatized urinary steroids is proposed. © 1997 by John Wiley & Sons, Ltd.  相似文献   

14.
《Analytical letters》2012,45(7):1313-1322
ABSTRACT

A method to detect three anabolic steroids (boldenone, nandrolone and mesterolone) is presented. The anabolic steroids are isolated from equine plasma and urine by extraction with diethyl ether and C18 Sep-Pak cartridge adsorption, respectively. The extracts obtained were derivatized with trifluoroacetyl anhydride and analyzed by GC/SIM/MS. The selected ion monitoring (SIM) mode was applied to increase the sensitivity and, when possible, the higher m/z ions were selected to improve identification. Stability of derivatives was good and compounds having hydroxy and conjugated ketone groups produced trifluoroacetyl ester derivatives that were also stable. Repeatability of the chromatographic analysis was evaluated on the basis of area repeatability, and the coefficient of variation obtained was lower than 4.4. The detection limit was 1 and 5 ng/ml for all the anabolic steroids studied in equine plasma and urine, respectively.  相似文献   

15.
A fast and sensitive liquid chromatography/triple quadrupole tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of morphine, codeine, 6‐acetylmorphine (6‐AM), cocaine and benzoylecgonine (BE) in hair. Pulverized hair samples were extracted with methanol, and a 50 µL supernatant aliquot was injected into the LC/MS/MS system. Chromatography was performed with an XBridge? phenyl column (3.5 µm particle size, 4.6 × 150 mm), and the mobile phase was composed of methanol and 10 mM ammonium acetate adjusted to pH 4.00 with 99% formic acid (95:5, v/v). A separation run with isocratic elution was completed in 10 min at a flow rate of 500 µL/min. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification of each analyte. Deuterated analogues as internal standards were used for quantification and qualification. Linearity was established in the concentration range of 100–3000 pg/mg. The limits of detection were 10 pg/mg for morphine, codeine and 6‐AM; and 1 pg/mg for cocaine and BE. The precision and accuracy were determined by spiking hair samples at six concentration levels. For all analytes, the relative standard deviations of intra‐ and inter‐day precision were 0.1–6.3% and 1.5–10.6%, respectively. The accuracy ranged from 92.7 to 109.7%. The validated LC/MS/MS method was successfully applied to the analysis of 79 authentic hair samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A simple and sensitive procedure for the quantification of two commonly abused aryl-propionamide-derived selective androgen receptor modulators (SARMs), namely S-4 (GTx-007, andarine) and S-22 (GTx-024, MK-2866, ostarine, enobosarm), has been described. Urine samples were prepared for analysis by means of a dispersive liquid–liquid microextraction using methanol and chloroform as dispersive and extracting solvents, respectively. Factors that might influence the extraction process as well as their optimum conditions were evaluated by Box–Benken and central composite designs. After extraction, the analytes were quantified by UHPLC–MS/MS. The proposed procedure was validated on human urine samples. As a result, for both SARMs the detection limits were observed at 0.05 ng/mL and calibration curves were linear in the concentration range of 0.25–50 ng/mL with the coefficient of determination of 0.998.  相似文献   

17.
Abnormal production or metabolism of steroid hormones is responsible for the development of endocrine diseases. Thus, accurate quantification of steroid hormones is needed for both research into clinical conditions and diagnostic and monitoring purposes. An improved analytical method for profiling 39 steroids in urine using LC–MS/MS was developed. As a pre-treatment procedure prior to LC–tandem mass spectrometry (LC–MS/MS) analysis, hydrolysis using β-glucuronidase and solid-phase extraction for purifying the samples were performed. Steroids were separated using Waters ACQUITY BEH C18 column (2.1 × 100 mm, 1.7 μm) and a mobile phase consisting of eluent A (0.01% formic acid and 1 mm ammonium formate in water) and eluent B (0.01% formic acid and 1 mm ammonium formate in methanol) with a gradient program at a flow rate of 0.4 mL/min. Under the optimized method, the linearity of calibration curves was higher than 0.992. The limits of detection at signal-to-noise ratio of 3 were 0.03–90 ng/mL. The developed novel LC–MS/MS method can quantitatively profile 39 steroids in a single analytical run. Steroid profiling based on quantitative results could improve the diagnosis and monitoring of hormone-dependent diseases.  相似文献   

18.
综述了固相微萃取/气相色谱/质谱(SPME/GC/MS)在各种环境水、土壤等样品中农药残留分析中的应用和发展。SPME/GC/MS联用技术具有快速、简便、准确等优点。  相似文献   

19.
A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.  相似文献   

20.
The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号