首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07–0.92 µg mL?1 and 0.21–2.77 µg mL?1 respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 µg L?1), tetracycline (146 µg L?1) and doxycycline (110 µg L?1). In effluent waste water samples no target antibiotics were detected.   相似文献   

2.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

3.
A gas chromatography–tandem mass spectrometry (GC–MS/MS) method has been developed for the determination of selected pharmaceutical residues (carbamazepine, salicylic acid, clofibric acid, ibuprofen, 2-hydroxy-ibuprofen, fenoprofen, naproxen, ketoprofen, diclofenac, and triclosan) in sewage influent and roughly primary-treated effluent. The method involved solid-phase extraction (SPE) with polymeric sorbents, and two SPE cartridges were compared for the extraction and elution of the targeted compounds in complex matrices. A successful chemical derivatization of carbamazepine and acidic compounds using N,O-bis(trimethylsilyl) trifluoroacetamide +10% trimethylchlorosilane is also described. The quantification limits of the analytical procedure ranged from 30 to 60?ng?L?1 for 500?mL of wastewater. The best recovery rates (72–102%) in spiked effluent samples were obtained with Phenomenex Strata-X? cartridges. Detection limits (S/N?=?3) were estimated at between 1 and 18?ng?L?1. The reported GC–MS/MS method significantly reduces the strong matrix effects encountered with more expensive LC-MS/MS techniques. Application of the developed method showed that most selected analytes were detected at concentrations ranging from low µg?L?1 to trace level ng?L?1 in Montreal's wastewater treatment plant effluent and influent, as well as in the receiving waters at more than 8?km downstream of the effluent outfall. The rugged alternative analytical method is suitable for the simultaneous analysis of carbamazepine and pharmaceutical acidic residues in wastewater samples from influents and effluents that have undergone rough primary treatment.  相似文献   

4.
Chemical sensors relying on graphene-based materials have been widely used for electrochemical determination of metal ions and have demonstrated excellent signal amplification. This study reports an electrochemically reduced graphene oxide (ERGO)/mercury film (HgF) nanocomposite-modified pencil graphite electrode (PGE) prepared through successive electrochemical reduction of graphene oxide (GO) sheets and an in situ plated HgF. The ERGO-PG-HgFE, in combination with dimethylglyoxime (DMG) and square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV), was evaluated for the determination of Ni2+ in tap and natural river water samples. A single-step electrode pre-concentration approach was employed for the in situ Hg-film electroplating, metal-chelate complex formation, and non-electrolytic adsorption at –0.7 V. The current response due to nickel-dimethylglyoxime [Ni(II)-DMG2] complex reduction was studied as a function of experimental paratmeters including the accumulation potential, accumulation time, rotation speed, frequency and amplitude, and carefully optimized for the determination of Ni2+ at low concentration levels (μg?L?1) in pH 9.4 of 0.1 M NH3–NH4Cl buffer. The reduction peak currents were linear with the Ni2+ concentration between 2 and 16?μg?L?1. The limits of detection and quantitation were 0.120?±?0.002?µg?L?1 and 0.401?±?0.007?µg?L?1 respectively, for the determination of Ni2+ at an accumulation time of 120?s. The ERGO-PG-HgFE further demonstrated a highly selective stripping response toward Ni2+ determination compared to Co2+. The electrode was found to be sufficiently sensitive to determine metal ions in water samples at 0.1?µg?L?1, well below the World Health Organization standards.  相似文献   

5.
A sensitive and robust method using solid-phase extraction and ultrasonic extraction for preconcentration followed by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS–MS) has been developed for determination of 19 biocides: eight azole fungicides (climbazole, clotrimazole, ketoconazole, miconazole, fluconazole, itraconazole, thiabendazole, and carbendazim), two insect repellents (N,N-diethyl-3-methylbenzamide (DEET), and icaridin (also known as picaridin)), three isothiazolinone antifouling agents (1,2-benzisothiazolinone (BIT), 2-n-octyl-4-isothiazolinone (OIT), and 4,5-dichloro-2-n-octyl-isothiazolinone (DCOIT)), four paraben preservatives (methylparaben, ethylparaben, propylparaben, and butylparaben), and two disinfectants (triclosan and triclocarban) in surface water, wastewater, sediment, sludge, and soil. Recovery of the target compounds from surface water, influent, effluent, sediment, sludge, and soil was mostly in the range 70–120?%, with corresponding method quantification limits ranging from 0.01 to 0.31?ng?L?1, 0.07 to 7.48?ng?L?1, 0.01 to 3.90?ng?L?1, 0.01 to 0.45?ng?g?1, 0.01 to 6.37?ng?g?1, and 0.01 to 0.73?ng?g?1, respectively. Carbendazim, climbazole, clotrimazole, methylparaben, miconazole, triclocarban, and triclosan were detected at low ng?L?1 (or ng?g?1) levels in surface water, sediment, and sludge-amended soil. Fifteen target compounds were found in influent samples, at concentrations ranging between 0.4 (thiabendazole) and 372?ng?L?1 (methylparaben). Fifteen target compounds were found in effluent samples, at concentrations ranging between 0.4 (thiabendazole) and 114?ng?L?1 (carbendazim). Ten target compounds were found in dewatered sludge samples, at concentrations ranging between 1.1 (DEET) and 887?ng?g?1 (triclocarban).  相似文献   

6.
A fully automated method has been developed for determining eight macrocyclic musk fragrances in wastewater samples. The method is based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography–mass spectrometry (GC-MS). Five different fibres (PDMS 7 μm, PDMS 30 μm, PDMS 100 μm, PDMS/DVB 65 μm and PA 85 μm) were tested. The best conditions were achieved when a PDMS/DVB 65 μm fibre was exposed for 45 min in the headspace of 10 mL water samples at 100 °C. Method detection limits were found in the low ng L?1 range between 0.75 and 5 ng L?1 depending on the target analytes. Moreover, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in wastewater samples with relative standard deviations (n?=?5, 1,000 ng L?1) less than 9 and 14 %, respectively. The applicability of the method was tested with influent and effluent urban wastewater samples from different wastewater treatment plants (WWTPs). The analysis of influent urban wastewater revealed the presence of most of the target macrocyclic musks with, most notably, the maximum concentration of ambrettolide being obtained in WWTP A (4.36 μg L?1) and WWTP B (12.29 μg L?1), respectively. The analysis of effluent urban wastewater showed a decrease in target analyte concentrations, with exaltone and ambrettolide being the most abundant compounds with concentrations varying between below method quantification limit (<MQL) and 2.46 μg L?1.
Figure
Scheme of a HS-SPME followed by GC-MS to determine macrocyclic musk fragrances in wastewater samples  相似文献   

7.
A reliable multiclass method has been developed and validated for the determination of eight antibiotics from distinct classes (sulfonamides, macrolides, fluoroquinolones, tetracyclines, cephalosporins and dihydrofolate reductase inhibitors) in wastewater – influent and effluent – and surface water from Porto Alegre, Brazil. The pre-concentration and clean-up was conducted with a simple and fast protocol using solid-phase extraction allowing a 100-fold concentration factor. The proposed method was validated by using spiked blank wastewater samples in terms of linearity, repeatability, reproducibility, recovery, matrix effects and limits of detection and quantification. Recovery was obtained in the range of 66–149%. Method limit of quantification ranged between 1.6 and 61.7 ng L?1. Samples (n = 16) were taken from January to August 2011 in one wastewater treatment plant, which uses conventional biological treatment. Sulfamethoxazole and trimethoprim show higher concentration, ranging from >10 to <6500 ng L?1, whereas erythromycin presented the lower amount. Differences between influent and effluent profiles were discussed. Surface water samples (n = 8) were collected in Arroio Diluvio, in four sampling points, in February 2012. From the eight antibiotics analysed, five were detected: sulfamethoxazole, trimethoprim, azythromicyn, ciprofloxacin and norfloxacin, in a concentration range of 376–572 ng L?1, 27–94 ng L?1, 24–40 ng L?1, 16–66ng L?1 and 30–54 ng L?1, respectively.  相似文献   

8.
Electromembrane extraction (EME) is a powerful extraction and preconcentration technique for ionizable species. However, the ionic contents in the sample can influence the extraction efficiency and system stability due to electrolysis. In this work, the electromembrane extraction of chromium(VI) was developed using various levels of ionic samples. 2-Nitrophenyl octyl ether was the most suitable supported liquid membrane that delayed the electrolytic occurrence of air bubbles at the electrodes due to its high viscosity and high dielectric constant properties. The electromembrane extraction method was optimized using 5?mM NaCl (630?µS?cm?1); the applied potential was 100?V and the extraction time was 15?min. The enrichment factor of 80 was obtained over a linear working range of 10.0–80.0?µg?L?1. The method performance was tested using mineral water, drinking water, tap water, and surface water. The method recoveries based on matrix-matched calibration were 95–125% with standard deviations within 15%.  相似文献   

9.
In this study, a practicable and effective analytical method based on solid-phase-extraction and reversed-phase liquid chromatography with fluorescence detection (SPE-LC-FLD) was developed and partially validated for routine analysis of eight FQs in wastewater at the trace level. Different SPE materials, pH conditions and eluents were modified to find an economic and effective SPE conditions. In our work, it is the first time that well-known commercially available SPE sorbent are compared to ‘generic’ cheap SPE sorbent. Aqueous samples (pH 2–3) were extracted using Anpel? MEP cartridges where they were subsequently eluted by 6?mL of 2% formic acid in MeOH. The aqueous extracts were analysed by gradient elution LC-FLD, whose initial mobile phase was composed of ACN and 10?mmol?L?1 tetrabutyl ammonium bromide (4/96, v/v, pH 3). The LODs and LOQs of the wastewater were as low as 0.32–2.12?ng?L?1 and 1.07–7.07?ng?L?1, respectively. The precisions of the overall method (RSD, n?=?3) using wastewater were below 10%. The method was used to quantify FQs in influents and effluents of several typical sewage treatment plants (STPs) in Shanghai. The extraction recoveries of 100?mL influent, 500?mL effluent and 500?mL of river water samples were between 88.6 and 102.6%, 79.2 and 109.2%, 80.0 and 105.5% and 87.4 and 99.4%, respectively. FQs of interest except sarafloxacin were identified in the influents, effluents and river waters with concentrations varying from 0.012–1.163?µg?L?1, 0.003–0.291?µg?L?1, and 0.002–0.040?µg?L?1, respectively. The method can serve as a tool to obtain detailed information on occurrence, behaviour and fate of FQs in the aquatic environment. Occurrence of FQs detected in summer is higher than in spring at STPs, and those detected in the suburban area are less than those in the urban area. Complete removal of FQs is not achieved from the STPs, indicating domestic wastewater and STP discharge is the source of FQs in the surface water.  相似文献   

10.
This study presents the atmospheric pressure photoionization (APPI) of high‐chlorinated (five or more chlorine atoms) polychlorinated biphenyls (PCBs) using toluene as dopant, after liquid chromatographic separation. Mass spectra of PCB 101, 118, 138, 153, 180, 199, 206 and 209 were recorded by using liquid chromatography‐APPI‐tandem mass spectrometry (LC‐APPI‐MS/MS) in negative ion full scan mode. Intense peaks appeared at m/z that correspond to [M ? Cl + O]? ions, where M is the analyte molecule. Furthermore, a detailed strategy, which includes designs of experiments, for the development and optimization of LC‐APPI‐MS/MS methods is described. Following this strategy, a sensitive and accurate method with low instrumental limits of detection, ranging from 0.29 pg for PCB 209 to 8.3 pg for PCB 101 on column, was developed. For the separation of the analytes, a Waters XSELECT HSS T3 (100 mm × 2.1 mm, 2.5 µm) column was used with methanol/water as elution system. This method was applied for the determination of the above PCBs in water samples (surface water, tap water and treated wastewater). For the extraction of PCBs from water samples, a simple liquid–liquid extraction with dichloromethane was used. Method limits of quantification, ranged from 4.8 ng l?1, for PCB 199, to 9.4 ng l?1, for PCB 180, and the recoveries ranged from 73%, for PCB 101, to 96%, for PCB 199. The estimated analytical figures were appropriate for trace analysis of high‐chlorinated PCBs in real samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
A simple and efficient method known as dispersive liquid-liquid microextraction (DLLME) was demonstrated for the extraction of triadimefon, uniconazole and tebuconazole in real water samples prior to high performance liquid chromatography-ultraviolet detection (HPLC-UV). Several related parameters that could affect the extraction efficiencies were also investigated and optimised. Under the optimum conditions, a linear range was obtained between the peak area and the concentration of the interested analytes over the concentration range of 1.5–100?µg?L?1 for triadimefon, 2.0–100?µg?L?1 for uniconazole and tebuconazole, respectively. The limits of detection (LODs) (S/N?=?3) values were in the range of 0.9–1.2?µg?L?1. The intra-day and inter-day precisions for the analysis ranged from 2.8 to 7.6%. The relative recoveries of the three analytes in tap, well and lake water samples were in the range of 90.6–105.3%. Finally, a comparison of the sensitivity between the proposed DLLME and the improved single-drop microextraction was also evaluated.  相似文献   

12.
In the present study, room-temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafluorophosphate was used as extraction solvent in a liquid–liquid microextraction (LLME) procedure followed by liquid chromatography for determining 4-nonylphenol (4-NP) and 4-tert-octylphenol (4-t-OP) in environmental water samples. RTIL-based LLME was a simple, inexpensive, and fast sample preparation method, and its parameters such as extraction time, addition of salt, selection of phase ratio, and pH value were optimized. The optimized method had acceptable limits of detection (LOD) and a precision of 2?µg?L?1 and 8.1% for 4-NP and 0.6?µg?L?1 and 3.7% for 4-t-OP, respectively. The proposed method was successfully applied in river water and effluent from a sewage-treatment plant, and the recoveries spiked at 6?µg?L?1 and 25?µg?L?1 levels were in the range of 82–113%.  相似文献   

13.
A sensitive and reliable method using capillary HPLC with UV-diode array detection (DAD) has been developed and validated for trace determination of carbamate pesticides in cucumber and environmental water samples. The analytes, including carbofuran, carbaryl, methiocarb, promecarb, benthiocarb and fenoxycarb, present legal residue levels regulated by the EU Council Directive 98/83/EC on drinking water and by the Regulation (EC) No. 396/2005 on vegetables. A previous off-line solid-phase extraction (SPE) procedure was required for preconcentration and sample clean-up. The separation was achieved using a C18 column (150?mm?×?0.5?mm I.D, 5?µm particle size) and a mobile phase consisting of ACN?:?water using gradient mode, with a flow rate of 10?µl min?1. Taking advantages of the characteristics of capillary HPLC, low volume of sample and solvents were required, achieving limits of detection for the studied compounds ranged from 10.0–29.6?ng l?1 for water samples and 1.8–5.6?µg kg?1 for cucumber, using UV-detection. Recoveries studies for fortified samples, at three different concentration levels, were carried out obtaining recoveries ranging from 70.0 to 111.1% and relative standard deviations (RSDs) lower than 10.6%.  相似文献   

14.
15.
A simple, rapid and low cost method for determination of phthalic acid esters (PAEs) including Dimethyl phthalate (DMP), Diethyl phthalate (DEP), Di-n-butyl phthalate (DBP) and Butylbenzyl phthalate (BBP) in water samples was investigated. The method is based on the extraction of PAEs with coacervate made up of decanoic acid reverse micelles and the subsequent determination by HPLC-UV. Effect of parameters such as concentration of tetrahydrofuran (THF) (2?C40% v/v) and decanoic acid (20?C400 mg in 40 ml total volume), ionic strength (0.0?C0.1 M NaCl), pH (1?C4) and stirring time (2?C60 min) on recoveries (Rs) and enrichment factors (EFs) were investigated and optimized. The optimum condition for extraction was the stirring of 36 ml of water sample with 4 ml of THF containing 100 mg of decanoic acid for 10 min and its centrifugation (10 min, 3500 rpm). Recoveries and enrichment factors of PAEs mainly depended on the amount of decanoic acid and THF making up the coacervate and were not affected by ionic strength of the sample solution (up to 0.1 M of NaCl), pH (1?C4), and stirring time (2?C60 min). Recoveries, enrichment factors, LODs and relative standard deviations (RSD%) for PAEs were between 87?C94%, 187?C202, 0.22?C0.30 ??g l?1 and 2?C5%, respectively. This method was applied to determine PAEs in tap water, river water, and sea water samples. No PAEs were found in tap water. The amount of DMP and DEP in the Babolrood River was 0.87 and 0.67 ??g l?1, while in the Caspian Sea was 0.49 and 0.52 ??g l?1, respectively.  相似文献   

16.
This study features the simultaneous extraction and quantification of 18 pharmaceuticals and personal care products (PPCPs). This is a pioneering method for the quantification of acetaminophen, sulfamethoxazole, diclofenac, atenolol, metoprolol, diethyltoluamide and oxybenzone in atmospheric pressure chemical ionisation mode. The method was validated for high repeatability and reproducibility with relative standard deviations less than 10%. Instrument quantification limits for PPCPs were within the range of 0.05–1.0 µg L?1, and the method quantification limits (MQLs) for ultrapure water were within the range of 0.3–15 ng L?1. All samples were extracted using Oasis© hydrophilic–lipophilic balanced cartridges with optimised sample size and extraction conditions. Good accuracy was demonstrated, with solid-phase extraction recoveries above 80% for most PPCPs. In environmental matrices, the MQLs for river water, sewage treatment plant (STP) effluent and STP influent were 4–25, 10–153 and 38–386.5, respectively. The method was successfully applied to investigate occurrences of persistent PPCPs in Malaysian river and sewage samples.  相似文献   

17.
A simple and fast voltammetric method based on a new electrode composed of carbon paste electrode/bifunctional hybrid ion imprinted polymer (CPE/IIP) was developed for the quantification of Cd2+ in water samples. The voltammetric measurements by Differential Pulse Voltammetry were performed by using CPE containing 11.0 mg of IIP under phosphate buffer solution at concentration 0.1 mol L?1 and pH 6.5. The electrochemical method was carried out by Cd2+ preconcentration at ?1.2 V during 210 s, followed by anodic stripping. The performance of IIP towards Cd2+ determination was evaluated by comparison to non-imprinted polymer, whose detectability of IIP was much higher (45%). The sensitivity of the sensor was found to be 0.0105 µA/µg L?1. The limits of detection and limits of quantification were found to be 4.95 μg L?1 and 16.4 μg L?1, respectively. The developed method was successfully applied to Cd2+ determination in mineral, tap and lake water samples, whose results are in agreement with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) used as reference analytical technique. According to achieved results, the developed method can be used for routine analysis of quality control of water samples from different sources.  相似文献   

18.
A hexagonal mesoporous silica (HMS) functionalized with a 5-mercapto-1-methyltetrazole derivative was employed to prepare a chemically modified carbon paste electrode for Pb(II) detection in aqueous solution by square wave adsorptive stripping voltammetry. The optimal operating conditions were 5 min preconcentration time at pH 6.5, and 120 s electrolysis time in 0.2 mol L?1 HCl. Under these conditions, the voltammetric signal increased linearly with the preconcentration time in the range 1 to 10 min and with the Pb(II) concentration in the range 1 to 100?µg L?1. The electrode was reproducible and sensitive. Simultaneous determination of Pb, Cd and Cu was also carried out with the electrode. The accuracy of the method was validated by analysing Pb(II) in tap water and groundwater samples.  相似文献   

19.
Microwave plasma torch (MPT), traditionally used as the light source for atomic emission spectrophotometry, has been employed as the ambient ionization source for sensitive detection of uranium in various ground water samples with widely available ion trap mass spectrometer. In the full‐scan mass spectra obtained in the negative ion detection mode, uranium signal was featured by the uranyl nitrate complexes (e.g. [UO2(NO3)3]?), which yielded characteristic fragments in the tandem mass spectrometry experiments, allowing confident detection of trace uranium in water samples without sample pretreatment. Under the optimal experimental conditions, the calibration curves were linearly responded within the concentration levels ranged in 10–1000 µg·l?1, with the limit of detection (LOD) of 31.03 ng·l?1. The relative standard deviations (RSD) values were 2.1–5.8% for the given samples at 100 µg·l?1. The newly established method has been applied to direct detection of uranium in practical mine water samples, providing reasonable recoveries 90.94–112.36% for all the samples tested. The analysis of a single sample was completed within 30 s, showing a promising potential of the method for sensitive detection of trace uranium with improved throughput. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
This study describes the utilisation of a glassy carbon electrode modified with a composite of multi-walled carbon nanotube and Cr-based metal-organic framework (MIL-101, Cr-BDC, BDC = 1,4-benzenedicarboxylate) for the sensitive, simple and fast voltammetric determination of picloram in environmental samples. Under optimum conditions, additions of picloram using square wave voltammetry showed linear ranges of picloram concentrations from 24.15 to 3018 µg?L?1 (0.1–12.5 μM) and from 3018 to 9658 µg?L?1 (12.5–40 μM) with a detection limit of 14.49 µg?L?1 (0.06 µM). The method was successfully applied to the determination of picloram in tap and river water samples spiked with picloram without any purification step by the standard addition method. The good recovery values obtained ranging from 97.5% to 105.0% revealed the reliability and accuracy of the method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号