首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A column, solid phase extraction (SPE), preconcentration method was developed for determination of silver by using alumina coated with 1-((5-nitrofuran-2-yl)methylene)thiosemicarbazide and determination by flame atomic absorption spectrometry. The separation/preconcentration conditions for the quantitative recovery were investigated. At pH 2, the maximum sorption capacity of Ag+ was 7.5?mg?g?1. The linearity was maintained in the concentration range of 0.02–11.0?µg?mL?1 in the final solution or 0.14–1.10?×?104?ng?mL?1 in the original solution for silver. The preconcentration factor of 140 and relative standard deviation of ±1.4% was obtained, under optimum conditions. The limit of detection (LOD) was calculated as 0.112?ng?mL?1, based on 3σbl/m (n?=?8) in the original solutions. The proposed method was successfully applied to the determination trace amounts of silver in the environmental samples such as tea, rice and wheat flour, mint, and real water samples.  相似文献   

2.
A simple, highly sensitive and environment-friendly method, combined with flame atomic absorption spectroscopy (FAAS) is developed to preconcentrate and determine trace amounts of thallium in aqueous solutions. In the preconcentration step, the thallium (I) from 30?mL of an aqueous solution was extracted into 350?µL of ionic liquid, 1-hexyl-3-methylimidazolium hexa?uorophosphate [Hmim][PF6], containing dicyclohexyl-18-crown-6 (DCH-18-crown-6) as complexing agent. Subsequently, the DCH-18-crown-6 complex was back-extracted into 300?µL of nitric acid (2?mol?L?1) solution, and analyzed by FAAS. Several parameters in?uencing the extraction and determination of thallium, such as pH, concentration of DCH-18-crown-6, sonication and centrifugation times, sample volume, ionic liquid amounts, ionic strength, and concentration of stripping acid solution, were optimized. Under optimum conditions, the calibration graph was linear in the range of 5 to 400?ng?mL?1, the detection limit was 0.64?ng?mL?1 (3Sb/m, n?=?7), the enhancement factor was 98.2 and the relative standard deviation was ±1.43%. The results for preconcentration and determination of trace amount of thallium in waste water, well water, tap water, sea water, human hair and nail demonstrated the accuracy, recovery and applicability of the presented method.  相似文献   

3.
A rapid method for the extraction and monitoring of nanogram level of Pb2+, Cu2+ and Zn2+ ions using uniform silanized mesopor (SBA-15) functionalized with diethylenetriamine groups and flame atomic absorption spectrometry (FAAS) is presented. The preconcentration factor of the method is 100 and detection limit of the technique is 5.5?ng?mL?1 and 1.4?ng?mL?1 and 0.1?ng?mL?1 for Pb2+, Cu2+ and Zn2+ respectively. The time and the optimum amount of the sorbent, pH and minimum amount of acid for stripping of ions from functionalized SBA-15 were tested. The maximum capacity the functionalized SBA-15 was found to be 183.0 (±1.9) µg, 156.0 (±1.5) µg and 80.0 (±1.6) µg of Pb2+, Cu2+ and Zn2+/mg functionalized SBA-15, respectively.  相似文献   

4.
A solid phase extraction method for simultaneous preconcentration and separation of trace amounts of copper, cobalt and silver in different samples, using a column packed with modified Amberlyst®15 resin is developed. Amberlyst®15 resin was modified with 5-(4-dimethylaminobenzylidene)rhodanine and then the modified resin was used as a support material for the solid phase extraction and preconcentration of Cu(II), Co(II) and Ag(I) ions from aqueous solution in the pH range 3.5–4.5. The adsorbed metal ions on the column were quantitatively eluted with a 7% thiourea solution prepared in 2?mol?L?1 HNO3, which were detected by flame atomic absorption spectrometry. The effects of analytical parameters including pH of the solution, eluent type, flow rate of samples, eluent and matrix ions were investigated for optimization of the presented procedure. The detection limits were 2.1, 0.9 and 0.9?ng?mL?1 for Cu(II), Co(II) and Ag(I) ions, respectively based on the three times the standard deviations of the blanks. The preconcentration factor was 112.5. The calibration graphs were obtained in the ranges of 0.05 to 10.0, 0.03 to 13.0 and 0.04 to 9.0?µg?mL?1 for Cu(II), Co(II) and Ag(I) ions concentrations, respectively. Relative standard deviations (n?=?7) for Cu(II), Co(II) and Ag(I) ions were found ±2.5 %, ±0.84% and ±3.8% respectively. The method was applied to the determination of mentioned ions in well water, waste water and lettuce sample.  相似文献   

5.
In the present work, a new SiO2/TiO2/Ce, nanoparticle was synthesed using sol-gel method and evaluated as an adsorbent for preconcentration trace amounts of Pd(II) ions. The characterization of the nanoparticles has been studied by transmission electron microscope and X-ray diffraction. The preconcentration method is based on palladium adsorption onto the surface of nanoparticle at pH 8.5. The main factors affecting Pd(II) adsorption, such as pH of sample solution, concentration and volume of eluent, sample volume, interfering of the coexisting ions and flow rate of sample and eluent were investigated and optimized. At optimum conditions, linearity was maintained between 4.0 to 1000.0 ng mL?1. Detection limit based on 3Sb/m was 2.3 ng mL?1. Seven replicate determinations of a solution containing of 12.5 µg palladium gave a relative standard deviation ±1.7%. According to the Langmuir linear model, the maximum adsorption capacity of palladium was found to be 34.5 mg g?1. Finally, the feasibility of the proposed method for Pd(II) determination was assessed by analysis of certified reference materials, anodic slime and wastewater samples and satisfactory results were obtained.   相似文献   

6.
A new, simple, fast and reliable solid-phase extraction method has been developed for separation/preconcentration of trace amounts of Pb(II) using dithizone/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles, and its determination by flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after eluting with 4.0?mol?L?1 HNO3. Optimal experimental conditions including pH, sample volume, eluent concentration and volume, and co-existing ions have been studied and established. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of Pb(II) using FAAS technique were 280 (for 560?mL of sample solution), 0.28?ng?mL?1, 1.4?C70?ng?mL?1 and 4.6% (for 10?ng?mL?1, n?=?10), respectively. These analytical parameters using GFAAS technique were 300 (for 600?mL of sample solution), 0.002?ng?mL?1, 0.006?C13.2?ng?mL?1 and 3.1% (for 5?ng?mL?1, n?=?10), respectively. The presented procedure was successfully applied for determination of Pb(II) content in opium, heroin, lipstick, plants and water samples.  相似文献   

7.
In the present study, the ?5-(4-dimethylaminobenzylidene)rhodanin-modified SBA-15? was applied as stable solid sorbent for the separation and preconcentration of trace amounts of cobalt ions in aqueous solution. SBA-15 was modified by ?5-(4-dimethylaminobenzylidene)rhodanin reagent. The sorption of Co2+ ions was done onto modified sorbent in the pH range of 6.8–7.9 and desorption occurred in 5.0 mL of 3.0 mol L?1 HNO3. The results exhibit a linear dynamic range from 0.01 to 6.0 mg L?1 for cobalt. Intra-day (repeatability) and inter-day (reproducibility) for 10 replicated determination of 0.06 mg L?1 of cobalt was ±1.82% and ?±1.97%?. Detection limit was 4.2 µg L?1 (3Sb, n = 5) and preconcentration factor was 80. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type and interference ions were studied for the preconcentration of Co2+. The proposed method was applied for the determination of cobalt in standard samples, water samples and agricultural products.  相似文献   

8.
A solid phase extraction procedure for the separation and preconcentration of trace amounts of Cd(II) and Pb(II) using the alizarin red S modified TiO2 nanoparticles prior to their determination by flame atomic absorption spectrometry has been proposed. The influences of some analytical parameters such as pH, flow rates of sample and eluent, type and concentration of the eluent, and interfering ions on the recovery of Cd(II) and Pb(II) by the sorbent were investigated. The analytes were quantitatively sorbed from the aqueous solution at pH 5.5 onto a microcolumn packed with the sorbent and recovered with 2.0?mL of 1.5?mol?L?1 hydrochloric acid. Under the optimum experimental conditions, the detection limits for Cd(II) and Pb(II) were 0.11 and 0.30?ng?mL?1 and the relative standard deviations for ten replicate measurements of 5.0 and 50.0?ng?mL?1 of Cd(II) and Pb(II) were 2.1 and 1.9%, respectively. A sample volume of 200?mL resulted in a preconcentration factor of 100. The method was successfully applied to the determination of Cd(II) and Pb(II) in water and biological samples, and accuracy was examined by the recovery experiments, independent analysis using electrothermal atomic absorption spectrometry, and analysis of a water standard reference material (SRM 1643e).  相似文献   

9.
An organo-nanoclay is used as a new, easily accessible, and stable solid sorbent for the preconcentration of trace amounts of rhodium ions from aqueous solution, this followed by its determination by flame atomic absorption spectrometry (FAAS). Rh(III) ion was first complexed with 2,3,5,6-tetra(2-pyridyl) pyrazine (TPPZ) at pH values between 3.0 and 4.7, and then the complex was then adsorbed onto the nanoclay. The rhodium ions were eluted from the sorbent with HCl. The rhodium in the effluent was determined by FAAS. The linear analytical range is between 0.14 ng mL?1 and 20.0 μg mL?1 in the initial solution, the relative standard deviation at 2.0 μg mL?1 of rhodium is 2.6% (n?=?8), the detection limit is 0.03 ng mL?1, and the preconcentration factor is 140. Experimental parameters including the pH, eluent type, interference by other ions and breakthrough volume were optimized. The method was applied to the determination of rhodium in water, road dust and synthetic samples.  相似文献   

10.
A new, simple, fast and reliable solid-phase extraction (SPE) method has been developed to separation/preconcentration of trace amounts of silver ion from environmental water samples using dithizone/sodium dodecyl sulfate immobilized on alumina-coated magnetite nanoparticles (DTZ/SDS-ACMNPs) and its determination by flame atomic absorption spectrometry. The coating of alumina on Fe3O4 NPs not only avoids the dissolving of Fe3O4 NPs in acidic solution, but also extends their application without sacrificing their unique magnetization characteristics. This method avoided the time-consuming column-passing process of loading large volume samples in traditional SPE through the rapid isolation of DTZ/SDS-ACMNPs with an adscititious magnet. Optimal experimental conditions including amount of DTZ/SDS, pH value, standing time, sample volume, type, volume and concentration of eluent and co-existing ions have been studied and established. Under the optimal experimental conditions, the detection limit for Ag(I) with enrichment factors of 100 was found to be 0.52?ng?mL?1 and its relative standard deviations (RSD) was 3.4% (n?=?10, C?=?5.0?µg?mL?1). The linear range of calibration curve for Ag(I) was 2–5000?ng?mL?1 with a correlation coefficient of 0.9991. The proposed method was successfully applied to the determination of target analyte in different water and wastewater samples. The validity of the method has been checked by applying it to study the recovery of silver ion in spiked water and wastewater samples.  相似文献   

11.
A solid-phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the retention of silver on sulfur modified with 2-mercaptobenzoxazole. The retained silver is eluted from the column with a thiourea solution and determined by flame atomic absorption spectrometry. The preconcentration conditions such as pH, amount of reagent loaded on sorbent, type of eluent and its volume, flow rate and interfering ions were investigated. The calibration graph was linear in the range of 3–200 ng mL?1 of Ag+ in the initial solution with r = 0.9985. The limit of detection based on 3Sb was 1.0 ng mL?1. The relative standard deviation for ten replicate measurements of 50 and 150 ng mL?1 of Ag+ was 4.1 and 1.4 %, respectively. The method was applied to the determination of silver in radiology film and water samples.  相似文献   

12.
A solid‐phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the adsorption of silver on naphthalene modified with dithizone in a column. The adsorbed silver is eluted from the column with a thiourea solution and determined by flame atomic absorption spectrometry. The adsorption conditions including pH, reagent concentration, eluent volume, flow rate and interfering ions were investigated. The calibration graph was linear in the range 10–1000 ng mL?1 of Ag in the initial solution with r = 0.9998. The limit of detection based on 3Sb was 3.9 ng mL?1. The relative standard deviation for ten replicate measurements of 40 and 600 ng mL?1 of Ag was 4.4% and 0.9%, respectively. The method was applied to the determination of silver in mineral, radiology film and wound dressing samples.  相似文献   

13.
The efficiencies and performances of silver nanoparticle loaded activated carbon modified with 2-(4-isopropylbenzylideneamino)thiophenol (IPBATP-Ag-NP-AC) and activated carbon modified with IPBATP (IPBATP-AC), as new sorbents, were evaluated for separation and preconcentration of Cu2+, Zn2+, Co2+, Cd2+ and Pb2+ ions from real environmental samples. The retained metals content was reversibly eluted using 5?mL of CH3COOH (6.0?mol?L?1) and/or 10?mL of 4.0?mol?L?1 HNO3 for IPBATP-Ag-NP-AC and IPBATP-AC, respectively. The experimental parameters influence the recoveries of metal ions including pH, amounts of ligand and supports, condition of eluents, sample and eluent flow rates of has been investigated. The preconcentration factors were found to be 100 for Zn2+, Cd2+, Co2+, Cu2+ and 50 for Pb2+ ions using IPBATP-Ag-NP-AC, and 50 for Zn2+, Cd2+, Co2+, Cu2+ and 25 for Pb2+ ions using IPBATP-AC. The detection limit of both SPE-based sorbents was between 1.6–2.5?ng?mL?1 for IPBATP-AC and 1.3–2.5?ng?mL?1 for IPBATP-Ag-NP-AC. The proposed methods have been successfully applied for the extraction and determination of the understudy metal ions content in some real samples with extraction efficiencies higher than 90% and relative standard deviations (RSD) lower than 2.4%.  相似文献   

14.
The possibility of using Thio-Michler's Ketone (TMK), 4,4′-bis(dimethylamino) thiobenzophenone, for palladium(II) concentrated by micellar extraction at the cloud-point temperature, and later spectrophotometric determination, was investigated. Under the optimum conditions, preconcentration of 50?mL of water samples in the presence of 0.1% (w/v) octylphenoxy polyethoxy ethanol (Triton X-114), 2?×?10?6?mol?L?1?TMK and 1?×?10–3?mol?L?1 buffer solution (pH?=?3.0) gave the limit of detection of 0.47?ng?mL?1, and the calibration graph was linear in the range of 2–50?ng?mL–1. The recovery under optimum working conditions was higher than 97%. The proposed method has been applied to the spectrophotometric determination of palladium(II) in natural water samples after cloud-point extraction with satisfactory results.  相似文献   

15.
A new highly sensitive, stable, and accurate fluorometric method for the determination of indium(III) has been established in cetyltrimethylammonium bromide(CTMAB) microemulsion media. The excellent color-forming reagent 2,6,7-trihydroxy-9-(3,5-dibromo-4-hydroxyphenyl) fluorone (DBH-PF) reacts with indium(III) to form a purple complex with a 3 : 1 (ligand to metal) ratio in HAc-NaAc buffer solution at pH 4.94. The emission peak occurs at 556 nm with excitation at 525 nm. Indium(III) can be determined in the linear range of 0.005–0.30 μg mL−1 with a detection limit of 0.0029 μg mL−1. Foreign ions are eliminated by preconcentration and separation with sulfhydryl dextranegel (SDG). The proposed method has been satisfactorily examined for the determination of indium(III) in ore and sludge samples. The relative standard deviations are in all instances less than 3.0%, and the recoveries are between 94.7, and 99.5%. __________ From Zhurnal Analiticheskoi Khimii, Vol. 60, No. 9, 2005, pp. 979–984. Original English Text Copyright ? 2005 by Wei Qin, Du Bin, Zhang Hui, Li Yan, Li Zaijun. The text was submitted by the authors in English.  相似文献   

16.
We have prepared a highly selective and efficient sorbent for the simultaneous separation and preconcentration of lead and cadmium ions from milk and water samples. An ionic liquid was deposited on the surface of magnetic nanoparticles (IL-MNPs) and used for solid phase extraction of these ions. The IL-MNPs carrying the target metals were then separated from the sample solution by applying an external magnetic field. Lead and cadmium were almost quantitatively retained by the IL-MNPs, and then eluted with nitric acid. The effect of different variables on solid phase extraction was investigated. The calibration curve is linear in the range from 0.3 to 20?ng mL?1 of Cd(II), and from 5 to 330?ng mL?1 of Pb(II) in the initial solution. Under optimum conditions, the detection limits are 1.61 and 0.122?μg?L-1 for Pb(II) and Cd(II) respectively. Relative standard deviations (n?=?10) were 2.87?% and 1.45?% for 0.05?μg?mL-1 and 0.2?μg?mL-1 of Cd (II) and Pb (II) respectively. The preconcentration factor is 200 for both of ions.
Figure
A novel, highly selective and efficient sorbent, was prepared and applied for separation and preconcentration of lead and cadmium from real samples. Lead and cadmium could be quantitatively retained by ionic liquid-modified magnetite nanoparticles and then easily separated from the aqueous solution by applying an external magnetic field; so, no filtration or centrifugation was necessary.  相似文献   

17.
《Analytical letters》2012,45(16):2996-3005
Abstract

A effective and simple determination of poisonous trace element thallium(I) by means of kinetic catalytic reaction is proposed. The method is based on a catalytic effect of thallium(I) on a luminol-hydrogen peroxide system. Three different kinds of surfactants, cetrimonium bromide (CTMAB), sodium dodecyl sulphate (SDS), and Tween-80, are also investigated to improve the detection sensitivity. In optimum conditions, a highly selective and sensitive method for detecting trace thallium(I) has been established. The detection limit is 0.0073 µg · mL?1, the relative standard deviation for six determinations of 0.04 µg · mL?1 thallium(I) is less than 4.0%, and the linear range of determination is 0.02–0.1 µg · mL?1.  相似文献   

18.
A sensitive and simple solid‐phase preconcentration procedure for the determination of trace amount of lead by flame atomic absorption spectrometry (FAAS) is developed. The method is based on the adsorption of Pb2+ on the column of fine grinded eucalyptus stem adsorbent, elution of the column by nitric acid and subsequent determination by FAAS. The effect of different variables such as pH, eluent type, flow rate and interfering ions on the recovery of the analyte was investigated and optimum conditions were established. The adsorption of lead onto fine grinded eucalyptus stem can formally be described by a Langmuir equation with a maximum adsorption capacity of 4.49 mg g?1. A preconcentration factor of 50 was achieved using the optimum conditions. The calibration graph was linear in the range 10–125 ng mL?1 of lead in the initial solution with r = 0.9982. The limit of detection based on 3Sb criterion was 4.5 ng mL?1 and the relative standard deviation for eight replicate measurements of 30 and 80 ng mL?1 of iron was 3.6 and 2.8%, respectively. The method was successfully applied to the determination of lead added to well, tap and wastewater samples.  相似文献   

19.
A differential pulse polarographic method for the determination of the herbicide thiazopyr has been developed. The polarographic study of thiazopyr exhibited two well-defined cathodic peaks within the pH range of 1.0 to 8.0. The variation of pH and polarographic parameters indicated that the optimum conditions under which thiazopyr could be reduced were a pH 7.0 BR buffer solution, a reduction peak potential of ?1270 mV (vs. SCE), scan rate of 5 mV s?1, pulse amplitude of 50 mV with pulse duration of 50 ms at an ambient temperature of 25 ± 3°C. The main reduction peak was characterised by cyclic voltammetry as being irreversible and diffusion-controlled. A linear relationship between the peak current and the concentration of thiazopyr was obtained in the range of 0.43–38.6 µg mL?1, with a detection limit of 0.127 µg mL?1. The proposed method was successfully applied to the determination of thiazopyr in spiked fruit juice and soil samples. The mean recoveries of the 19.8 µg g?1 and 3.96 µg mL?1 thiazopyr spiked to soil and orange juice were 20.2 ± 1.0 µg g?1 and 3.84 ± 0.12 µg mL?1, at 95% confidence level, respectively. The sufficiently good recoveries and low relative standard deviation (RSD) data confirm the high accuracy and precision of the proposed method. The interferences effects of several commonly used pesticides and inorganic species were also studied. Interfering effects were eliminated either by providing selectivity with pH, or using EDTA as complexing agent.  相似文献   

20.
Multiwalled carbon nanotubes chemically functionalized with 2-((3-silylpropylimino) methyl) phenol (SPIMP-MWCNT) and successfully applied for the solid phase extraction (SPE) of some metal ions in food samples. The influences of the analytical parameters including pH, amounts of solid phase, eluent conditions (type, volume and concentrations), sample volume and interference of some metal ions on the recoveries of ions Cu2+, Pb2+, Fe2+, Ni2+ and Zn2+ ion were investigated. The metal ions retained on SPIMP-MWCNT was eluted using 6?mL of 4?mol?L?1 HNO3 solution and their content was determined by flame atomic absorption spectrometry (FAAS) with recoveries more than 95% and relative standard deviations (n?=?5) between 2.4–3.4% for both reproducibility and repeatability. The detection limit of this metal ions was between 1.0–2.6?ng?mL?1 (3S b , n?=?10) and their preconcentration factor was 100, while their loading capacity was above 32.9?mg?g?1 of SPIMP-MWCNT. The proposed method was successfully applied for the preconcentration and determination of analytes in different samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号