首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A new sensor has been developed for the simultaneous detection of cadmium, lead, copper and mercury, using differential pulse and square wave anodic stripping voltammetry (DPASV and SWASV) at a graphite–polyurethane composite electrode with SBA‐15 silica organofunctionalized with 2‐benzothiazolethiol as bulk modifier. The heavy metal ions were preconcentrated on the surface of the modified electrode at ?1.1 V vs. SCE where they complex with 2‐benzothiazolethiol and are reduced to the metals, and are then reoxidized. Optimum SWASV conditions lead to nanomolar detection limits and simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ in natural waters was achieved.  相似文献   

2.
In the present work, a sensitive, facile and disposable sensing platform for trace analysis of heavy metal ions was developed at the Bi modified graphene‐poly(sodium 4‐styrenesulfonate) composite film screen printed electrode (GR/PSS/Bi/SPE). The GR/PSS/Bi/SPE improved sensitivity and linearity due to the functionalization of graphene with negatively charged PSS providing more absorbing sites. The detection limit of the GR/PSS/Bi/SPE is found to be 0.042 µg L?1 for Cd2+ and 0.089 µg L?1 for Pb2+ with linear responses of Cd2+ and Pb2+ in the range of 0.5–120 µg L?1. Finally, the practical application was confirmed in real water with satisfactory results.  相似文献   

3.
Carboxylated peptide‐functionalized gold nanoparticles (peptide‐GNPs) self‐assemble into two‐ and three‐dimensional nanostructures in the presence of various heavy metal ions (i.e. Pb2+, Cd2+, Cu2+, and Zn2+) in aqueous solution. The assembly process is monitored by following the changes in the surface plasmon resonance (SPR) band of gold nanoparticles in a UV/Vis spectrophotometer, which shows the development of a new SPR band in the higher‐wavelength region. The extent of assembly is dependent on the amount of metal ions present in the medium and also the time of assembly. TEM analysis clearly shows formation of two‐ and three‐dimensional nanostructures. The assembly process is completely reversible by addition of alkaline ethylenediaminetetraacetic acid (EDTA) solution. The driving force for the assembly of peptide‐GNPs is mainly metal ion/carboxylate coordination. The color and spectral changes due to this assembly can be used for detection of these heavy‐metal ions in solution.  相似文献   

4.
Stable ultra‐thin Langmuir monolayers of calix[4]resorcinarene derivatives, namely: C‐dec‐9‐enylcalix[4]resorcinarene‐O‐(R+)‐α‐methylbenzylamine (Ionophore I ), and C‐dec‐9‐enylcalix[4]resorcinarene‐O‐(S‐)‐α‐methylbenzylamine (Ionophore II ), were prepared at the air‐water interface. Their interactions with a series of heavy metals (HM) ions (Cu2+, Pb2+, Hg2+ and Cd2+) present in the aqueous subphase were investigated by measuring surface pressure‐area isotherms, at different concentrations. The surface pressure‐area (Π‐A) isotherms were stable and demonstrated the HM amounts influence on the limiting area (Alim) values, therefore confirming the examined macrocycles capability to host the metallic toxicants. Additionally, a HM concentration dependence was realized and interpreted by a selective tendency of both ionophores towards Cu2+ and Cd2+ ions over Pb2+ and Hg2+, especially at high concentrations. The HM ions interactions with the applied calix[4]resorcinarene Langmuir ultra‐thin monolayers were interpreted based on the Gibbs‐Shishkovsky adsorption equation. Moreover, quartz crystal microbalance with impedance measurement (QCM‐I), was applied for the detection of HM ions in solutions. The QCM‐I results showed the effectiveness of the coated QCM‐I crystals in detecting the ions at different concentrations. The detection limit values were in the order of 0.16, 0.3, 0.65, 1.1 ppm (Ionophore I), as well 0.11, 0.45, 0.2, 0.89 (Ionophore II) for the Cu2+, Pb2+, Hg2+ and Cd2+ cations, respectively. Additionally, a selective tendency of both ionophores towards copper ions was shown.  相似文献   

5.
Bishnu Prasad Joshi 《Talanta》2009,78(3):903-1129
A novel fluorescent peptide sensor containing tryptophan (donor) and dansyl fluorophore (acceptor) was synthesized for monitoring heavy and transition metal (HTM) ions on the basis of metal ion binding motif (Cys-X-X-X-Cys). The peptide probe successfully exhibited a turn on and ratiometric response for several heavy metal ions such as Hg2+, Cd2+, Pb2+, Zn2+, and Ag+ in aqueous solution. The enhancements of emission intensity were achieved in the presence of the HTM ions by fluorescent resonance energy transfer (FRET) and chelation enhanced fluorescence (CHEF) effects. The detection limits of the sensor for Cd2+, Pb2+, Zn2+, and Ag+ were lower than the EPA's drinking water maximum contaminant levels (MCL). We described the fluorescent enhancement, binding affinity, and detection limit of the peptide probe for HTM ions.  相似文献   

6.
This paper studied the electrochemical sensors based on C? C bonding of graphene oxide (GO) on π‐conjugated aromatic group modified gold electrodes for simultaneous detection of heavy metal ions. For comparison, another sensing interface Au‐Ph‐NH‐CO‐GO, in which GO was modified to Au‐Ph‐NH2 interfaces by amide bonding. On the basis of the principle of heavy metal ions complexation with oxygenated species on GO, the fabricated sensing interfaces were used for the simultaneous determination of Pb2+, Cu2+ and Hg2+. The performance of two sensing interfaces for simultaneous detection of three metal ions was compared. Au‐Ph‐GO sensing interface demonstrated higher sensitivity and better repeatability than Au‐Ph‐NH‐CO‐GO sensing interface.  相似文献   

7.
The competitive removal of Pb2+, Cu2+, and Cd2+ ions from aqueous solutions by the copolymer of 2‐acrylamido‐2‐methyl‐1‐propane sulfonic acid (AMPS) and itaconic acid (IA), P(AMPS‐co‐IA), was investigated. Homopolymer of AMPS (PAMPS) was also used to remove these ions from their aqueous solution. In the preparation of AMPS–IA copolymer, the molar percentages of AMPS and IA were 80 and 20, respectively. In order to observe the changes in the structures of polymers due to metal adsorption, FTIR spectra by attenuated total reflectancetechnique and scanning electron microscopy (SEM) pictures of the polymers were taken both before and after adsorption experiments. Total metal ion removal capacities of PAMPS and P(AMPS‐co‐IA) were 1.685 and 1.722 mmol Me2+/gpolymer, respectively. Experimental data were evaluated to determine the kinetic characteristics of the adsorption process. Competitive adsorption of Pb2+, Cu2+, and Cd2+ ions onto both PAMPS and P(AMPS‐co‐IA) was found to fit pseudo‐second‐order type kinetics. In addition, the removal orders in the competitive adsorption of these metal ions onto PAMPS and P(AMPS‐co‐IA) were found to be Cd2+ > Pb2+ > Cu2+ and Pb2+ > Cd2+ > Cu2+, respectively. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
In our study, the single‐use & eco‐friendly electrochemical sensor platform based on herbal silver nanoparticles (AgNPs) was developed for detection of mercury (II) ion (Hg2+). For this purpose, the surface of pencil graphite electrode (PGE) was modified with AgNPs and folic acid (FA), respectively. The concentrations of AgNPs and FA were firstly optimized by differential pulse voltammetry (DPV) to obtain an effective surface modification of PGE. Each step at the surface modification process was characterized by using cyclic voltammetry (CV) and electrochemical impedence spectroscopy (EIS). The limit of detection (LOD) for Hg2+ was estimated and found to be 8.43 μM by CV technique. The sensor presented an excellent selectivity for Hg2+ against to other heavy metal ions such as Ca2+, Cd2+, Cr3+, Cu2+, Mg2+, Ni2+, Pb2+, Zn2+, Co2+ and Mn2+. Moreover, a rapid, selective and sensitive detection of Hg2+ was successfully performed in the samples of tap water within 1 min.  相似文献   

9.
The availability of drinking water is of utmost importance for the world population. Anthropogenic pollutants of water, such as heavy‐metal ions, are major problems in water contamination. The toxicity assays used range from cell assays to animal tests. Herein, we replace biological toxicity assays, which use higher organisms, with artificial inorganic self‐propelled microtubular robots. The viability and activity of these robots are negatively influenced by heavy metals, such as Pb2+, in a similar manner to that of live fish models. This allows the establishment of a lethal dose (LD50) of heavy metal for artificial inorganic microfish robots. The self‐propelled microfish robots show specific response to Pb2+ compared to other heavy metals, such as Cd2+, and can be used for selective determination of Pb2+ in water. It is a first step towards replacing the biological toxicity assays with biomimetic inorganic autonomous robotic systems.  相似文献   

10.
Hui Xu  Xiwen Zeng  Huiling Dai 《中国化学》2011,29(10):2165-2168
A new fluorescent chemosensor based upon 1,8‐naphthalimide and 8‐hydroxyquinoline was synthesized, and its fluorescent properties in the presence of different metal cations (Hg2+, Ag+, Zn2+, Fe2+, Cd2+, Pb2+, Ca2+, Cu2+, Mg2+, and Ba2+) were investigated. It displayed fluorescence quenching with some heavy and transition metal (HTM) ions, and the quenching strongly depended on the nature of HTM ions.  相似文献   

11.
A green and facile method was developed to prepare a novel hybrid nanocomposite that consisted of one-dimensional multi-walled carbon nanotubes (MWCNTs) and two-dimensional graphene oxide (GO) sheets. The as-prepared three-dimensional GO–MWCNTs hybrid nanocomposites exhibit excellent water-solubility owing to the high hydrophilicity of GO components; meanwhile, a certain amount of MWCNTs loaded on the surface of GO sheets through π–π interaction seem to be “dissolved” in water. Moreover, the graphene(G)-MWCNTs nanocomposites with excellent conductivity were obtained conveniently by the direct electrochemical reduction of GO–MWCNTs nanocomposites. Seeing that there is a good synergistic effect between MWCNTs and graphene components in enhancing preconcentration efficiency of metal ions and accelerating electron transfer rate at G-MWCNTs/electrolyte interface, the G-MWCNTs nanocomposites possess fast, simultaneous and sensitive detection performance for trace amounts of heavy metal ions. The electrochemical results demonstrate that the G-MWCNTs nanocomposites can act as a kind of practical sensing material to simultaneously determine Pb2+ and Cd2+ ions in terms of anodic stripping voltammetry (ASV). The linear calibration plots for Pb2+ and Cd2+ ranged from 0.5 μg L−1 to 30 μg L−1. The detection limits were determined to be 0.2 μg L−1 (S/N = 3) for Pb2+ and 0.1 μg L−1 (S/N = 3) for Cd2+ in the case of a deposition time of 180 s. It is worth mentioning that the G-MWCNTs modified electrodes were successfully applied to the simultaneous detection of Cd2+ and Pb2+ ions in real electroplating effluent samples containing lots of surface active impurities, showing a good application prospect in the determination of trace amounts of heavy metals.  相似文献   

12.
A simple, low cost and sensitive voltammetric sensor was developed for the simultaneous detection of Pb2+, Cd2+, and Zn2+ based on a disposable carbon fiber rod (CFR). The important factors to enhance the sensing property were creation of a clean surface by dealing with CFR at a high potential and electrochemical deposition of Bi film to improve the accumulation of heavy metal ions.  相似文献   

13.
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb2+ and Cu2+ respectively. The technique was used for the detection of Pb2+ and Cu2+ in spiked lake water. The average recoveries of Pb2+ and Cu2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.  相似文献   

14.
The development of highly sensitive and selective methods for the detection of lead ion (Pb2+) is of great scientific importance. In this work, we develop a new surface‐enhanced Raman scattering (SERS)‐based sensor for the selective trace measurement of Pb2+. The SERS‐based sensor is assembled from gold nanoparticles (AuNPs) and graphene using cucurbit[7]uril (CB[7]) as a precise molecular glue and a local SERS reporter. Upon the addition of Pb2+, CB[7] forms stronger complexes with Pb2+ and desorbs from AuNPs, resulting in a sensitive “turn‐off” of SERS signals. This SERS‐based assay shows a limit of detection (LOD) of 0.3 nm and a linear detection range from 1 nm to 0.3 μm for Pb2+. The feasibility of the assay is further demonstrated by probing Pb2+ in real water samples. This SERS‐based analytical method is highly sensitive and selective, and therefore holds promising applications in environmental analysis.  相似文献   

15.
《Electroanalysis》2017,29(8):1903-1910
This paper describes the electrochemical behaviors of Cd2+ and Pb2+ on the proposed mesoporous carbon microspheres/mefenamic acid/nafion modified glassy carbon electrode (MC/MA/Nafion/GC) studied by square wave anodic stripping voltammetry (SWASV). The prepared material is characterized by XRD, SEM, FTIR, RAMAN and BET analysis. Experimental parameters, such as the deposition potential and time, the pH value of buffer solution were optimized. Under the optimized conditions, the electrode responded linearly to Cd2+ and Pb2+ in the concentration range from 50 to 300 nM, and the detection limits were 24.2 and 11.26 nM respectively. The sensitivity determined was 0.0623 μA/nM (Cd2+) and 0.192 μA/nM (Pb2+). Multiple metal ion detection with clear demarcation of peaks was produced by the electrode. Moreover, the modified electrode has possessed good selectivity and reproducibility of Cd2+ and Pb2+ detection. We also investigated the interference of various anions and surfactants for the detection of Cd2+ and Pb2+ ions. Finally the modified electrode was used to detect the presence of metal ions in practical samples and the results obtained are comparatively good with respect to AAS.  相似文献   

16.
ALI Moghimi 《中国化学》2007,25(5):640-644
A fast and simple method for preconcentration of Ni^2+, Cd^2+, Pb^2+, Zn^2+, Cu^2+ and Co^2+ from natural water samples was developed. The metal ions were complexed with sodium diethyldithiocarbamate (Na-DDTC), then adsorbed onto octadecyl silica membrane disk, recovered and determined by FAAS. Extraction efficiency, influence of sample volume and eluent flow rates, effects of pH, amount of Na-DDTC, nature and amount of eluent for elution of metal ions from membrane disk, break through volume and limit of detection have been evaluated. The effect of foreign ions on the percent recovery of heavy metal ions has also been studied. The limit of detection of the proposed method for Ni^2+, Cd^2+, Pb^2+, Zn^2+, Cu^2+ and Co^2+was found to be 2.03, 0.47, 3.13, 0.44, 1.24 and 2.05 ng·mL^-1, respectively. The proposed (DDTC) method has been successfully applied to the recovery and determination of heavy metal ions in different water samples.  相似文献   

17.
A water in soluble long‐chain crown ether alkyl (C18)‐benzo‐15‐crown‐5 was synthesized and applied as a coating material on quartz crystal membranes of a liquid flow piezo electric crystal sensor. The oscillating crown ether‐coated piezo electric (PZ) crystal with a home‐made computer inter face was prepared as a liquid chromato graphic (LC) detector for organic species and metal ions in aqueous solutions. The oscillating frequency of the quartz crystal decreased due to the adsorption of organic molecules or metal ions on crown ether molecules. Effects of functional group, molar mass, steric hindrance, and polarity of organic molecules on frequency responses of the crown ether coated PZ crystal detector were investigated. The frequency responses of the crown ether coated PZ crystal detector for various molecules were in the order: amines > carboxylic acids > alcohols > ketones. The crown ether PZ detector also exhibited good sensitivity for some heavy metal ions and the frequency shifts were in the order: Cr3+ » Pb2+ > Co2+ > Cd2+ > Ni2+ > Cu2+. The crown ether coated piezo electric crystal LC detector demonstrated low detection limits for various polar organic molecules, e.g., 6.0 × 10?5 M for propylamine, and metal ions, e.g., 2.9 × 10?5 M (1.8 ppm) for Cu2+; the crown ether PZ detector also gave good reproducibility when re used. A quite sensitive electrochemical quartz crystal microbalance (EQCM) detection system was also set‐up for detecting trace heavy metal ions in solutions. The variation in frequency of the PZ crystal and the diffusion current were observed simultaneously after the reduction in heavy metal ions such as Cu2+ and Ni2+. The EQCM detection system exhibited fairly good sensitivity, e.g., 112 Hz/ppm for Cu2+ and a good detection limit, e.g., 0.13 ppm for Cu2+ ions. Comparison between EQCM and PZ detection systems was made and discussed.  相似文献   

18.
《Electroanalysis》2018,30(3):533-542
A simple and highly sensitive electrochemical sensor COOH−C4 derived from dicarboxyl‐calix[4]arene modified on a screen printed gold electrode (Au) was developed for the determination of lead ions in water samples. A 3‐mercaptopropionic acid (MPA) monolayer was used as a template on the gold electrode for the surface modification with dicarboxyl‐calixarene. The modified electrodes were surface‐characterized using Fourier Transform infrared spectroscopy (FTIR). The data obtained proved the confirmation of each stage of the electrode modification. The electrochemical analyses of the COOH−C4 electrode showed an enhanced electrocatalytic activity and higher current towards Pb2+ ions as compared to the bare Au and MPA/Au electrodes. Under optimum conditions, the differential pulse voltammetry response of COOH−C4 displayed a wide linear response ranging from 280–2500 μg/L for Pb2+ with a detection limit of 6.2 μg/L. In addition, the fabricated electrode showed a high selectivity and stability towards the Pb2+ ions in presence of possible interfering species. The present method was successfully applied to determine Pb2+ ions in real samples with satisfactory precision, with a relative standard deviation of 3.12 % and an acceptable recovery of 92 %, which demonstrated the potential application of dicarboxyl‐calix[4]arene modified on electrodes for heavy‐metal sensing.  相似文献   

19.
Anodic stripping voltammetry (ASV) determination of Pb2+, Cd2+, and Zn2+ was done using metal catalyst free carbon nanotube (MCFCN) electrodes. Osteryoung square wave stripping voltammetry (OSWSV) was selected for detection. The MCFCNTs are synthesized via Carbo Thermal Carbide Conversion method which leads to residual transition metal free in the CNT structure. The new material shows very good results in detecting heavy metal ions, such as Pb2+, Cd2+, and Zn2+. The calculated limits of detection were 13 nM, 32 nM and 50 nM for Pb2+, Cd2+ and Zn2+, respectively with a deposition time of 150 s.  相似文献   

20.
A new chemically modified bismuth film electrode coated with an ionic liquid [(1‐ethyl‐3‐methylimidazolium tetracyanoborate (EMIM TCB)] and Nafion was developed for the simultaneous determination Pb2+ and Cd2+ by anodic stripping voltammetry. Compared with conventional bismuth film electrodes, this electrode exhibited greatly improved electrochemical activity for Pb2+ and Cd2+ detection due to the unique properties of Nafion polymer and ionic liquid. The key experimental parameters related to the fabrication of the electrode and the voltammetric measurements were optimized on the basis of the stripping signals, where the peak currents increased linearly with the metal concentrations in a range of 10–120 µg L?1 with a detect limit of 0.2 µg L?1 for Pb2+, and 0.5 µg L?1 for Cd2+ for 120s deposition. High reproducibility was indicated from the relative standard deviations (1.9 and 2.5 %) for nine repetitive measurements of 20 µg L?1 Pb2+ and Cd2+, respectively. In addition, the surface characteristics of the modified BiFE were investigated by scanning electron microscopy (SEM), and results showed that fibril‐like bismuth nanostructures were formed on the porous Nafion polymer matrix. Finally, the developed electrode was applied to determine Pb2+ and Cd2+ in water samples, indicating that this electrode was sensitive, reliable and effective for the simultaneous determination of Pb2+ and Cd2+.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号