首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 672 毫秒
1.
A method is described for automating the regulation of cold jet flow of a comprehensive two-dimensional gas chromatograph (GCxGC) configured with flame ionization detection. This new capability enables the routine automated separation, identification, and quantitation of hydrocarbon types in petroleum fractions extending into the vacuum gas oil (VGO) range (IBP-540 degrees C). Chromatographic data acquisition software is programmed to precisely change the rate of flow from the cold jet of a nitrogen cooled loop modulator of a GCxGC instrument during sample analysis. This provides for the proper modulation of sample compounds across a wider boiling range. The boiling point distribution of the GCxGC separation is shown to be consistent with high temperature simulated distillation results indicating recovery of higher boiling semi-volatile VGO sample components. GCxGC configured with time-of-flight mass spectrometry is used to determine the molecular identity of individual sample components and boundaries of different molecular types.  相似文献   

2.
Metrics for evaluation of separation performance of comprehensive two-dimensional gas chromatography (GCxGC) and for quantitative comparison of that performance with similar performance of its 1D (one-dimensional) counterparts are described. The performance improvement can be expressed via reduction in the saturation of a chromatogram or-in the case of the uniform distribution of peaks along the second dimension--via the peak capacity gain due to GCxGC. An order of magnitude peak capacity gain due to the comprehensive GCxGC is possible under optimal conditions. Optimal parameters of the second dimension column as well as the optimal operational conditions for that column and for the modulator in a comprehensive GCxGC are also presented.  相似文献   

3.
A flow-switching two-dimensional gas chromatography (GCxGC) apparatus has been constructed that can operate at temperatures as high as 340 degrees C. This system is employed to analyze complex hydrocarbon mixtures such as diesel fuel, gas-oil, motor oil, and petroleum contaminated environmental samples. The GCxGC system generates two-dimensional chromatograms with minimal overlap between the aliphatic and aromatic regions This allows these compound classes to be independently quantitated without prior fractionation. The GCxGC system is used to analyze extracts of spiked water samples, wastewater, and soil. The accuracy of the method is compared to that of the Massachusetts Extractable Petroleum Hydrocarbons (MA EPH) method. The GCxGC system generates a quantitative accuracy similar to the MA EPH method for the analysis of spiked water samples. The GCxGC method and the MA EPH method generate comparable levels of total hydrocarbons when wastewater is analyzed, but the GCxGC method detects a significantly higher aromatic content and lower aliphatic content. Both the GCxGC method and MA EPH method measure comparable levels of aromatics in the soil samples.  相似文献   

4.
The detailed characterization of middle distillates is essential for a better understanding of reactions involved in refining processes. Owing to a higher resolution power and an enhanced sensitivity, but especially to a group-type ordering in the chromatographic plane, comprehensive two-dimensional gas chromatography (GCxGC) offers unsurpassed characterization possibilities for petroleum samples. However, GCxGC fails to totally discriminate naphthenes from unsaturates occurring in hydrotreated diesel samples. This article aims at promoting the implementation of LC-GCxGC for the quantitative determination of hydrocarbon distribution in middle distillates, including naphthenes. In this configuration, liquid chromatography (LC) enables the separation of hydrocarbons into two fractions (viz., saturated and unsaturated) before the subsequent analysis of each fraction by GCxGC. In this paper, the choice of GCxGC conditions in order to achieve the separation and identification of hydrocarbons by chemical class is discussed; under these conditions, naphthenes are separated according to the number of saturated rings. For the first time, the presence of di-, tri-, and tetra-naphthenes resulting from the hydroconversion of aromatics can clearly be evidenced. A quantitative procedure for the determination of the distribution of hydrocarbons, including the distribution of naphthenes according to the number of saturated rings, is also proposed and discussed in detail. LC-GCxGC is found to provide an unequalled degree of information that will widely contribute to a better understanding of hydroconversion processes.  相似文献   

5.
Sulfur-containing compounds in diesel have been speciated by comprehensive two-dimensional gas chromatography (GCxGC) with a sulfur chemiluminescence detector (SCD). The advantages of GCxGC technique are higher resolution and greater sensitivity. GCxGC-SCD can achieve the class separation of sulfur-containing compounds with an appropriate separation column combination. The major classes of sulfur-containing compounds in diesel are benzothiophenes and dibenzothiophenes. Relative concentration of each class as well as each carbon number family can be quantitated by the summation of the integrated areas corresponding to the individual group(s) in the GCxGC space. In practical applications, GCxGC-SCD can be used to characterize different diesels and to reflect desulfurization process efficiency. In this study, GCxGC-SCD has demonstrated its value in speciation of sulfur-containing compounds classes, which is difficult to accomplish by any other single technique.  相似文献   

6.
In general, petrochemical products contain only a limited number of chemical classes of compounds (sample dimensionality). The enormous number of individual components within these classes, however, soon puts limitations upon a single chromatographic technique when it comes to adequate characterization of these products. Comprehensive two-dimensional gas chromatography (GC×GC) clearly opens the possibility of estimating the composition of hydrocarbon mixtures in a far more detailed fashion than hitherto possible. Although the emphasis of papers of GCxGC thus far almost exclusively applies to the unsurpassed peak-capacity, in the oil industry there is a need for characterization, rather than for analyzing all the individual compounds. In principle a GCxGC system can provide an almost perfect match between its intrinsic properties and the dimensionality of oil samples. To establish the applicability of GCxGC towards petrochemical analytical challenges, a commercially aavailable prototype instrument was subjected to an exhaustive characterization of a typical hydrocarbon precess stream and a fast characterization of a light gas oil. Although there are no fundamental limitations towards the quantitative aspects of a GCxGC system, this paper confines itself to qualitative results only. Quantitative aspects of GCxGC will be published in a forthcoming paper.  相似文献   

7.
A comprehensive GCxGC-TOFMS method was optimized for multiresidue analysis of pesticides using a combination of a non-polar (RTX-5MS, 10 m x 0.18 mm x 0.2 microm) and a polar capillary column (TR-50MS, 1 m x 0.1 mm x 0.1 microm), connected in series through a dual stage thermal modulator. The method resolved the co-elution problems as observed in full scan one-dimensional GC-MS analysis and allowed chromatographic separation of 51 pesticides within 24 min run time with library-searchable mass spectrometric confirmation. Four pesticides, viz. chlorpyrifos-methyl, vinclozoline, parathion-methyl and heptachlor could be baseline separated on GCxGC, which were otherwise closely eluting and interfering each other's detection in 1D GC-MS run. Similarly, it could be possible to separate myclobutanil, buprofezin, flusilazole and oxyfluorfen on GCxGC. Although in 1D GC-MS, these closely eluting compounds could be identified through deconvolution algorithm and 'peak-find' option of the Chromatof software but the spectral purity significantly improved on GCxGC analysis. Thorough optimization was accomplished for the oven temperature programming, ion source temperature and GCxGC parameters like modulation period, duration of hot pulses, modulation-offset temperature, acquisition rate, etc. to achieve best possible separation of the test compounds. The limit of detection significantly improved by 2-12 times on GCxGC-TOFMS against GC-TOFMS because of sharper and narrower peak shapes. The method was tested for grape matrix after preparing the samples using previously described method and recoveries of the entire test pesticides were within 70-110% at 10 ng/g level of fortification. GCxGC-TOFMS was found to be an excellent technique for library-based screening of pesticides with high accuracy and sensitivity.  相似文献   

8.
Comprehensive two-dimensional gas chromatography (GCxGC) has proven to be an extremely powerful separation technique for the analysis of complex volatile mixtures. This separation power can be used to discriminate between highly similar samples. In this article we will describe the use of GCxGC for the discrimination of crude oils from different reservoirs within one oil field. These highly complex chromatograms contain about 6000 individual, quantified components. Unfortunately, small differences in most of these 6000 components characterize the difference between these reservoirs. For this reason, multivariate-analysis (MVA) techniques are required for finding chemical profiles describing the differences between the reservoirs. Unfortunately, such methods cannot discern between 'informative variables', or peaks describing differences between samples, and 'uninformative variables', or peaks not describing relevant differences. For this reason, variable selection techniques are required. A selection based on information between duplicate measurements was used. With this information, 292 peaks were used for building a discrimination model. Validation was performed using the ratio of the sum of distances between groups and the sum of distances within groups. This step resulted in the detection of an outlier, which could be traced to a production problem, which could be explained retrospectively.  相似文献   

9.
Successful remediation of oil-contaminated soils relies on a sound preceding characterization of the oil chemical composition and physicochemical properties. Comprehensive two-dimensional gas chromatography with flame ionization detection (GCxGC/FID) is known to be very suitable for the analysis of complex samples such as petroleum hydrocarbons. However, in spite of the high-separation power offered by GCxGC, it fails to completely separate certain hydrocarbon groups in petroleum hydrocarbon mixtures. This hampers a detailed chemical composition assessment which can lead to wrong conclusions on the behaviour of the oil in soil systems, e.g. biological degradability and water solubility. This paper describes a high-performance liquid chromatography (HPLC) system with a silver-modified column as a prefractionation step to GCxGC to improve chemical identification. With HPLC, the petroleum hydrocarbons were baseline separated into a saturated fraction (including alkanes and cycloalkanes) and an unsaturated fraction (including alkenes, aromatic hydrocarbons and heterocyclic components). Each fraction eluted in a small time window limiting the dilution caused by HPLC. The two fractions were collected and quantitatively analyzed with GCxGC/FID. Cold splitless injection of 4 microl was adopted to compensate the dilution caused by the prefractionation step. With oil-spiked soil samples, a good reproducibility was obtained (RSD=3.5%; n=7) and the recovery was satisfactory (87.7%).  相似文献   

10.
李海静  刘国柱  张香文 《色谱》2018,36(8):780-785
采用全二维气相色谱-质谱联用(GC×GC-MS)考察了色谱柱系统、程序升温条件和调制周期3个主要因素对样品组分分离结果的影响,建立了煤油基吸热型碳氢燃料烃族组成的定性分析方法,并利用GC×GC-FID通过有效碳数校正因子对烃族组成进行定量。对选取的9种燃料的分析结果表明,该方法对链烷烃和环烷烃的定量结果与标准方法ASTM D2425的结果高度一致,相对误差基本均在±10%以内。利用该方法计算的碳含量结果与元素分析法相比误差均在0.5%以下。该方法无需复杂的前处理,稀释后可直接进样分析,操作简单,而且可直观地看出不同样品之间的差异,为改进燃料的性能提供了必要的分析手段。  相似文献   

11.
As a basic metric of separation for comparing isothermal and temperature-programmed GC (gas chromatography), we used the separation measure. S (defined elsewhere). We used this metric as both a measure of separation of any two peaks, and a measure of separation capacity of arbitrary intervals where peaks can potentially exist. We derived several formulae for calculation of S for any pair of peaks regardless of their shape and the distance from each other in isothermal and temperature-programmed GC. The formulae for isothermal GC can be viewed as generalizations of previously known expressions while, in the case of temperature-programmed GC, no equivalents for the new formulae were previously known from the literature. In all formulae for S. we identified similar key component-metrics (solute separability, intrinsic efficiency of separation, specific separation measure, separation power) that helped us to identify and better understand the key factors affecting the separation process. These metrics also facilitated the quantitative comparison of separation capacities and analysis times in isothermal and temperature-programmed GC. Some of these metrics can be useful beyond GC. In the case of GC, we have shown that, if the same complex mixture was analyzed by the same column, and the same separation requirements were used then isothermal analysis can separate more peaks than its temperature-programmed counterpart can. Unfortunately, this advantage comes at the cost of prohibitively longer isothermal analysis time. The latter is a well know fact. Here, however, we provided a quantitative comparison. In a specific example, we have shown that a single-ramp temperature program with a typical heating rate yields about 25% fewer peaks than the number of peaks available from isothermal analysis of the same mixture using the same column. However, that isothermal analysis would last 1000 times longer than its temperature-programmed counterpart. Using twice as longer column in the case of a temperature-programmed analysis, allows one to recover the 25% disadvantage in the number of separated peaks, while still retaining a 500-fold advantage in the speed of analysis.  相似文献   

12.
The use of gas chromatography (GC)-mass spectrometry (MS), GC-time-of-flight MS (TOFMS), comprehensive two-dimensional GC (GCxGC)-flame ionization detection (FID), and GCxGC-TOFMS is discussed for the characterization of the eight important representative components, including Z-alpha-santalol, epi-alpha-bisabolol, Z-alpha-trans-bergamotol, epi-beta-santalol, Z-beta-santalol, E,E-farnesol, Z-nuciferol, and Z-lanceol, in the oil of west Australian sandalwood (Santalum spicatum). Single-column GC-MS lacks the resolving power to separate all of the listed components as pure peaks and allow precise analytical measurement of individual component abundances. With enhanced peak resolution capabilities in GCxGC, these components are sufficiently well resolved to be quantitated using flame ionization detection, following initial characterization of components by using GCxGC-TOFMS.  相似文献   

13.
Gas chromatography-mass spectrometry (GC-MS) suffers from a major limitation in that an expanding number of thermally labile or low volatility compounds of interest are not amenable for analysis. We found that the elution temperatures of compounds from GC can be significantly lowered by reducing the column length, increasing the carrier gas flow rate, reducing the capillary column film thickness and lowering the temperature programming rate. Pyrene is eluted at 287 degrees C in standard GC-MS with a 30 m x 0.25 mm I.D. column with 1-microm DB5ms film and 1-ml/min He column flow rate. In contrast, pyrene is eluted at 79 degrees C in our "Supersonic GC-MS" system using a 1 m x 0.25 mm I.D. column with 0.1-microm DB5ms film and 100-ml/min He column flow rate. A simple model has been invoked to explain the significantly (up to 208 degrees C) lower elution temperatures observed. According to this model, every halving of the temperature programming rate, or number of separation plates (either through increased flow rate or due to reduced column length), results in approximately 20 degrees C lower elution temperature. These considerably lower elution temperatures enable the analysis of an extended range of thermally labile and low volatility compounds, that otherwise could not be analyzed by standard GC-MS. We demonstrate the analysis of large polycyclic aromatic hydrocarbons (PAHs) such as decacyclene with ten fused rings, well above the current GC limit of PAHs with six rings. Even a metalloporphirin such as magnesiumoctaethylporphin was easily analyzed with elution temperatures below 300 degrees C. Furthermore, a range of thermally labile compounds were analyzed including carbamates such as methomyl, aldicarb, aldicarbsulfone and oxamyl, explosives such as pentaerythritol tetranitrate, Tetryl and HMX, and drugs such as reserpine (608 a.m.u.). Supersonic GC-MS was used, based on the coupling of a supersonic molecular beam (SMB) inlet and ion sources with a bench-top Agilent 6890 GC plus 5972 MSD. The Supersonic GC-MS provides enhanced molecular ion without any ion source related peak tailing. Thus, the lower GC separation power involved in the analysis of thermally labile and low volatility compounds is compensated by increased separation power of the MS gained from the enhanced molecular ion. Several implications of these findings are discussed, including our conclusion that slower chromatography leads to better analysis of thermally labile compounds.  相似文献   

14.
A high-temperature configuration for a diaphragm valve-based gas chromatography (GCXGC) instrument is demonstrated. GCxGC is a powerful instrumental tool often used to analyze complex mixtures. Previously, the temperature limitations of valve-based GCxGC instruments were set by the maximum operating temperature of the valve, typically 175 degrees C. Thus, valve-based GCxGC was constrained to the analysis of mainly volatile components; however, many complex mixtures contain semi-volatile components as well. A new configuration is described that extends the working temperature range of diaphragm valve-based GCxGC instruments to significantly higher temperatures, so both volatile and semi-volatile compounds can be readily separated. In the current investigation, separations at temperatures up to 250 degrees C are demonstrated. This new design features both chromatographic columns in the same oven with the valve interfacing the two columns mounted in the side of the oven wall so the valve is both partially inside as well as outside the oven. The diaphragm and the sample ports in the valve are located inside the oven while the temperature-restrictive portion of the valve (containing the O-rings) is outside the oven. Temperature measurements on the surface of the valve indicate that even after a sustained oven temperature of 240 degrees C, the portions of the valve directly involved with the sampling from the first column to the second column track the oven temperature to within 1.2% while the portions of the valve that are temperature-restrictive remain well below the maximum temperature of 175 degrees C. A 26-component mixture of alkanes, ketones, and alcohols whose boiling points range from 65 degrees C (n-hexane) to 270 degrees C (n-pentadecane) is used to test the new design. Peak shapes along the first column axis suggest that sample condensation or carry-over in the valve is not a problem. Chemometric data analysis is performed to demonstrate that the resulting data have a bilinear structure. After over 6 months of use and temperature conditions up to 265 degrees C, no deterioration of the valve or its performance has been observed.  相似文献   

15.
This paper describes a new technique for removing the background level from digital images produced in comprehensive two-dimensional gas chromatography (GCxGC). Background removal is an important first step in the larger problem of quantitative analysis. The approach estimates the background level across the chromatographic image based on structural and statistical properties of GCxGC data. Then, the background level is subtracted from the image, producing a chromatogram in which the peaks rise above a near-zero mean background. After the background level is removed, further analysis is required to determine the quantitative relationship between the peaks and chemicals in the sample. The algorithm is demonstrated experimentally to be effective at determining and removing the background level from GCxGC images. The algorithm has several parametric controls and is incorporated into an interactive program with graphical interface for rapid and accurate detection of GCxGC peaks.  相似文献   

16.
An on-line coupling of size-exclusion Chromatography (SEC), normal-phase liquid Chromatography (NPLC), and gas Chromatography (GC) for the characterization of complex hydrocarbon mixtures is described. The hyphenated system separates according to size, polarity, and boiling point. The use of size exclusion as the first separation step allows for the direct injection of complex (“dirty”) samples withont prior clean-up. SEC-NPLC coupling was realized using an on-line solvent evaporator based on fully concurrent solvent evaporation (FCSE) using a modified loop-type interface, vapor exit and co-solvent trapping. Complete reconcentration of the analytes was realized by the introduction of a cryogenic cold trap. For the subsequent hydrocarbon group-type separation an ammo-silica column with n-heptane as eluent was used. The NPLC-GC coupling was based on an on-column interface using partially concurrent solvent evaporation (PCSE) and an early vapor exit. Initial results obtained on the analysis of a residue from the atmospheric crude-oil distillation (a so-called long residue) are presented as an example of the enormous separation power of the SEC-NPLC-GC system. The application of the system for quantitative analysis has not yet been studied.  相似文献   

17.
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has been applied for the quantitative speciation of sulfur containing compounds in gas oil (GO). For this purpose, ionization and mass spectrometric parameters have been studied and optimized with a set of standard compounds and GO samples. Comprehensive two-dimensional gas chromatography (GCxGC) was used as the reference method. To allow a quantitative comparison between FT-ICR MS and GCxGC results for GO samples, FT-ICR MS parameters were optimized and data obtained by both techniques were standardized. Response factors were established for two ionization modes: atmospheric pressure photo ionization (APPI) and electrospray after selective derivatization of sulfur compounds (MeESI). To test the validity of the developed MS methods, a third GO was analyzed and response factors were applied. Comparison with GCxGC results showed good agreement for sulfur families (deviation within 5% and 15% for MeESI and APPI data, respectively). Abundances of individual isomer groups match within 40% in most cases. These results principally demonstrate the suitability of FT-ICR MS for a quantitative analysis of sulfur compounds (by DBE and carbon number distribution pattern) in petroleum middle distillates. This approach has the potential to be extended to higher- and non-boiling petroleum fractions where quantitative speciation is presently not available.  相似文献   

18.
Fast screening of wash oils is demonstrated using comprehensive two-dimensional gas chromatography (GCxGC). Wash oils are used in ethylene production plants to minimize compressor fouling. The composition of a wash oil determines its effectiveness in solubilizing heavy hydrocarbons. In particular, the relative amount of 1- and 2-ring aromatics is important. The presence of oxygenates is undesirable because of adverse effects to the process. It is shown that GCxGC is well suited for this application. Species in wash oils are separated and grouped into three bands: a nonpolar aliphatics band, 1- and 2-ring aromatics band, and polyaromatics band. For a given polar secondary column, the spacing between bands in the second dimension can be adjusted in a broad range by selecting a primary column and an oven-temperature-programming rate. Integration of GCxGC peaks is evaluated using a standard GC integration program and a new GCxGC integration program. Consistent results are obtained using both programs for well-separated GCxGC peaks with relative differences for individual peak ranging from 0.04% to 1.6%. Peak responses are integrated by the GCxGC software, and the relative amounts of aromatics content and aliphatics content are estimated by peak response percent with relative standard deviations ranging from 0.15% to 2.8% (n = 3).  相似文献   

19.
汤娟  费晓庆  周佳  钱凯  董绍伟  曹丽华  丁友超 《色谱》2021,39(3):324-330
建立了同时测定化妆品中18种氯代烃类有机溶剂的气相色谱-质谱(GC-MS)检测方法。样品在饱和氯化钠溶液中由正十四烷振荡提取后,以Agilent J&W DB-624超高惰性毛细管柱(30 m×0.25 mm×1.4 μm)为分离色谱柱进行分析,以电子轰击(EI)源、SIM模式进行质谱监测,外标法定量。结果表明,18种化合物在19 min内完成色谱分离分析,检出限(LOD, S/N=3)和定量限(LOQ, S/N=10)分别为0.033~0.049 mg/L和0.10~0.15 mg/L, 18种氯代烃类有机溶剂在0.2~100 mg/L线性范围内线性关系良好,相关系数(R2)均不小于0.9992。以阴性样品口红(固体)和漱口水(液体)为样品基质,在不同添加水平下,18种氯代烃类有机溶剂的平均回收率分别为92.4%~103.1%和93.3%~102.4%,相对标准偏差(RSD, n=6)分别为3.1%~5.3%和2.8%~5.4%。采用该方法对115个化妆品样品进行测定,3个指甲油样品均检测出四氯乙烯,测定值为11.4~42.0 g/kg。研究建立的方法采用高沸点溶剂作为进样溶剂,取消溶剂延迟时间,使只能在溶剂延迟时间出峰的化合物得到有效色谱分离,分析时间短,且重复性好,灵敏度高,可同时检测各种化妆品中多种氯代烃类有机溶剂。该方法的建立为我国化妆品中氯代烃类有机溶剂检测标准的制订和质量安全监控提供了参考。  相似文献   

20.
The monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis. Different samples of middle distillates have been analyzed to demonstrate the high potential and important advantages of GCxGC-SCD for innovative and quantitative analysis of sulfur-containing compounds. More accurate and detailed results for benzothiophenes and dibenzothiophenes are presented, showing that GCxGC-SCD should become, in the future, an essential tool for sulfur speciation analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号