首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Photorelease of caged Ca(2+) is a uniquely powerful tool to study the dynamics of Ca(2+)-triggered exocytosis from individual cells. Using photolithography and other microfabrication techniques, we have developed transparent microchip devices to enable photorelease of caged Ca(2+), together with electrochemical detection of quantal catecholamine secretion from individual cells or cell arrays as a step towards developing high-throughput experimental devices. A 100 nm thick transparent indium-tin-oxide (ITO) film was sputter-deposited onto glass coverslips, which were then patterned into 24 cell-sized working electrodes (approximately 20 microm by 20 microm). We loaded bovine chromaffin cells with acetoxymethyl (AM) ester derivatives of the Ca(2+) cage NP-EGTA and Ca(2+) indicator dye fura-4F, then transferred these cells onto the working ITO electrodes for amperometric recordings. Upon flash photorelease of caged Ca(2+), a uniform rise of [Ca(2+)](i) within the target cell leads to quantal release of oxidizable catecholamines measured amperometrically by the underlying ITO electrode. We observed a burst of amperometric spikes upon rapid elevation of [Ca(2+)](i) and a "priming" effect of sub-stimulatory [Ca(2+)](i) on the response of cells to subsequent [Ca(2+)](i) elevation, similar to previous reports using different techniques. We conclude that UV photolysis of caged Ca(2+) is a suitable stimulation technique for higher-throughput studies of Ca(2+)-dependent exocytosis on transparent electrochemical microelectrode arrays.  相似文献   

2.
This paper describes the fabrication and characterization of a microfluidic device that utilizes a reservoir-based approach for endothelial cell immobilization and integrated embedded carbon ink microelectrodes for the amperometric detection of extracellular nitric oxide (NO) release. The design utilizes a buffer channel to continuously introduce buffer or a plug of stimulant to the reservoir as well as a separate sampling channel that constantly withdraws buffer from the reservoir and over the microelectrode. A steel pin is used for both the fluidic connection to the sampling channel and to provide a quasi-reference electrode for the carbon ink microelectrode. Characterization of the device was performed using NO standards produced from a NONOate salt. Finally, NO release from a layer of immobilized endothelial cells was monitored and quantified using the system. This system holds promise as a means to electrochemically detect extracellular NO release from endothelial cells in either an array of reservoirs or concurrently with fluorescence-based intracellular NO measurements.  相似文献   

3.
There is an increasing interest in new strategies to detect neurotransmitters released from nerve cells in real time for brain science, drug assessment, and so on. Previously we reported real-time monitoring of dopamine release from nerve model cells by enzyme-catalyzed luminescence measurement with tyramine oxidase and peroxidase. In the present study, the system was modified with glutamate oxidase instead of tyramine oxidase to detect L-glutamate sensitively (≈ 10 nM) and rapidly with high temporal resolution (<1 s). We applied this modified method successfully to perform real-time monitoring of L-glutamate release from brain model cell (C6 glioma cell) using a luminescence plate reader upon stimulation with high concentration of KCl (>10 mM) or 5-hydroxytryptamine (>1 μM). The measurement solution was not toxic and therefore the L-glutamate release from the cell was measured by the second stimulation after exchanging the measurement solution. We conclude that the developed monitoring system is suitable for real-time detection of dynamic L-glutamate release from nerve cells in vitro and will be suitable for application in assessment of drugs acting on the nervous system. Figure Enzyme luminescence detection of L-glutamate released from cells  相似文献   

4.
Pyrrole-functionalised tetracarboxyphenyl porphyrin and trimethoxyphenylcarboxy-phenyl porphyrin containing Ni, Mn and Pd as the central metal ion were used to modify Pt-disk microelectrodes (∅ 50 μm) (by repetitive cyclic voltammetry, dip-dry and pulse-amperometry methods) for the detection of nitric oxide (NO). Electrodes modified with Mn(II) trimethoxyphenylcarboxyphenyl porphyrin using the pulse amperomery approach, were found to be sensitive, stable and fast in response towards the oxidation of NO. Thus, they were used for the detection of NO release from a population of transformed human umbilical vein endothelial cells (T-HUVEC) into a droplet of electrolyte solution following stimulation with vascular endothelial growth factor (VEGF). The electrode surface was covered with an additional layer of Nafion® to prevent interference from anionic molecules such as nitrite.  相似文献   

5.
A lab-on-a-chip device that enables positioning of single or small ensembles of cells on an aperture in close proximity to a mercaptopropionic acid (MPA) modified sensing electrode has been developed and characterized. The microchip was used for the detection of Ca(2+)-dependent quantal catecholamine exocytosis from single as well as small assemblies of rat pheochromocytoma (PC12) cells. The frequency of events increased considerably upon depolarization of the PC12 cell membrane using a high extracelluar concentration of potassium. The number of recorded events could be correlated with the number of cells immobilized on the electrode. Quantal characteristics, such as the number of released molecules per recorded event, are equivalent to data obtained using conventional carbon fiber microelectrodes. The detection sensitivity of the device allows for the detection of less than 10 000 dopamine molecules in a quantal release. The distribution of peak rise-time and full width at half maximum was constant during measurement periods of several minutes demonstrating the stability of the MPA modified surface.  相似文献   

6.
A planar ultramicroelectrode nitric oxide (NO) sensor was fabricated to measure the local NO surface concentrations from NO-releasing microarrays of varying geometries. The sensor consisted of platinized Pt (25 microm) working electrode and a silver paint reference electrode coated with a thin silicone rubber gas permeable membrane. An internal hydrogel layer separated the Pt working electrode and gas permeable membrane. The total diameter of the sensor was 相似文献   

7.
Mecker LC  Martin RS 《Electrophoresis》2006,27(24):5032-5042
The fabrication and evaluation of micromolded dual carbon ink electrodes and their integration with a fabricated palladium decoupler for use in microchip electrophoresis is described. As opposed to previous work involving carbon-based dual electrodes with microchip electrophoresis, this approach results in electrodes that are amenable to mass production in a manner where the decoupler/electrode alignment is fixed and reproducible. In this work, electrode sizes and spacings were optimized to result in dual carbon electrodes that are 1 microm in height and separated by 100 microm. Fluorescence microscopy was used to investigate leakage around the electrode/channel interface as well as to investigate what effect the dual electrodes have on band broadening phenomena. The performance of the microelectrodes was demonstrated by the separation and selective dual electrode detection of neurotransmitters in the presence of ascorbic acid. It was also found that addition of SDS to the buffer system improved both the LODs and collection efficiencies. This approach, which is the first involving carbon-based dual electrodes with an on-chip palladium decoupler, will be useful for separating and detecting neurotransmitters that are either collected by in vivo sampling or released from cells on-chip.  相似文献   

8.
In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use of a polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated species that releases NO through a proton-driven mechanism. An Elast-Eon E2As polyurethane coating is used to both moderate NO release from the sensor surface and increase the sensor''s linear detection range toward glucose. These sensors were evaluated for thromboresistance and in vivo glucose performance through implantation in rabbit veins. By maintaining NO flux on a similar scale to endogenous endothelial cells, implanted glucose sensors exhibited reduced surface clot formation which enables more accurate quantitative glucose measurements continuously. An in vivo time trace of implanted venous sensors demonstrated glucose values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. The raw measured currents from the implanted glucose sensors over 7 h time periods were converted to glucose concentration through use of both a one-point in vivo calibration and a calibration curve obtained in vitro within a bovine serum solution. Control sensors, assembled without NO release functionality, exhibit distinctive surface clotting over the 7 h in vivo implantation period.  相似文献   

9.
A simple method for immobilizing a confluent layer of bovine pulmonary artery endothelial cells (bPAECs) in microchip-based channels is described. The microchips are prepared from poly(dimethylsiloxane) and have channel dimensions that approximate resistance vessels in vivo. The reversibly sealed channels were coated with fibronectin (100 microg ml(-1)) by aspiration. The bPAECs, which were introduced in the same manner, became attached to the fibronectin coating in about 2 h. The microchip could then be resealed over a micromolded carbon ink electrode (24 microm width x 6 microm height). Coating the carbon microelectrode with a 0.05% Nafion solution selectively blocked nitrite (10 microM) from being transported to the electrode surface while nitric oxide (NO, 10 microM) was amperometrically measured. Upon stimulation with adenosine triphosphate (ATP, 100 microM) the immobilized bPAECs produced and released micromolar amounts of NO. This NO production was effectively inhibited when the immobilized cells were incubated with L-nitro-arginine methyl ester (L-NAME), a competitive inhibitor for nitric oxide synthase. Moreover, once the immobilized bPAECs were no longer able to produce NO, incubation with L-arginine allowed for further ATP-stimulated NO production.  相似文献   

10.
Fluorescence resonance energy transfer (FRET)-based genetically encoded metal-ion sensors are important tools for studying metal-ion dynamics in live cells. We present a time-resolved microfluidic flow cytometer capable of characterizing the FRET-based dynamic response of metal-ion sensors in mammalian cells at a throughput of 15 cells/s with a time window encompassing a few milliseconds to a few seconds after mixing of cells with exogenous ligands. We have used the instrument to examine the cellular heterogeneity of Zn(2+) and Ca(2+) sensor FRET response amplitudes and demonstrated that the cluster maps of the Zn(2+) sensor FRET changes resolve multiple subpopulations. We have also measured the in vivo sensor response kinetics induced by changes in Zn(2+) and Ca(2+) concentrations. We observed an ~30 fold difference between the extracellular and intracellular sensors.  相似文献   

11.
Nitric oxide (NO) produced by endothelial NO synthase (eNOS) plays an important role in vascular functions, including vasorelaxation. We here investigated the pharmacological effect of the natural product syringaresinol on vascular relaxation and eNOS-mediated NO production as well as its underlying biochemical mechanism in endothelial cells. Treatment of aortic rings from wild type, but not eNOS(-/-) mice, with syringaresinol induced endothelium-dependent relaxation, which was abolished by addition of the NOS inhibitor N(G)-monomethyl-L-arginine. Treatment of human endothelial cells and mouse aortic rings with syringaresinol increased NO production, which was correlated with eNOS phosphorylation via the activation of Akt and AMP kinase (AMPK) as well as elevation of intracellular Ca(2+) levels. A phospholipase C (PLC) inhibitor blocked the increases in intracellular Ca(2+) levels, AMPK-dependent eNOS phosphorylation, and NO production, but not Akt activation, in syringaresinol- treated endothelial cells. Syringaresinol-induced AMPK activation was inhibited by co-treatment with PLC inhibitor, Ca(2+) chelator, calmodulin antagonist, and CaMKKβ siRNA. This compound also increased eNOS dimerization, which was inhibited by a PLC inhibitor and a Ca(2+)-chelator. The chemicals that inhibit eNOS phosphorylation and dimerization attenuated vasorelaxation and cGMP production. These results suggest that syringaresinol induces vasorelaxation by enhancing NO production in endothelial cells via two distinct mechanisms, phosphatidylinositol 3-kinase/Akt- and PLC/Ca(2+)/CaMKKβ-dependent eNOS phosphorylation and Ca(2+)-dependent eNOS dimerization.  相似文献   

12.
For the treatment of chronic inflammation in the oral cavity, we attempted to develop bioadhesive tablets of bovine lactoferrin (B-LF). Pectin was used as a bioadhesive polymer, and the influence of the degree of esterification and the molecular weight of pectins on the characteristics of B-LF tablets were investigated. Concerning bioadhesive force, a tendency increasing the value according to increase of the esterification of the pectin was confirmed. Sustained release of B-LF from the tablets was observed as the esterification increased, and a possibility for prediction of the time required to release 50% of B-LF by using the equation given by the degree of esterification and the logarithm of the molecular weight was suggested. Pectin cross-linked with Ca(2+) (Ca-PC) was also used for the preparation of the B-LF tablets. Prolonged release of B-LF from the tablets was observed as the Ca(2+) in Ca-PC increased. Our findings suggest that pectin with a high degree of esterification is suitable as a bioadhesive polymer since high bioadhesive force and sustained release are shown. Furthermore, a possibility that the B-LF release could be controlled by adjusting the Ca(2+) concentration in Ca-PC was suggested.  相似文献   

13.
14.
The efficient synthesis, physicochemical and photolytical properties of a photoactivable BAPTA-based Ca(2+) cage containing two photosensitive o-nitrobenzhydryl groups attached to the aromatic core are described. Ca(2+) release in living cells was evaluated. The double substitution with the chromophores caused a significant improvement of the Ca(2+) release properties of nitr-T versus singly substituted reported nitr-x derivatives without compromising Ca(2+)/Mg(2+) selectivity or pH insensitivity. Our results demonstrate a general strategy to improve light-triggered Ca(2+) release which may result in more efficient, selective, and pH-insensitive photolabile Ca(2+) chelators.  相似文献   

15.
The release of nitric oxide (NO) from polymers has proven to be highly effective at inhibiting platelet adhesion and thus enhancing the blood compatibility of medical implants. Micropatterning techniques were used to design surfaces that release NO while preserving the underlying substrate for other applications (e.g., sensors). Micropatterned NO-releasing substrates based on aminosilane-containing methyltrimethoxysilane sol-gels were prepared and characterized in terms of stability, NO surface flux, and resistance to in vitro platelet adhesion. We have found that surface-localized NO release from substrates modified with sol-gel micropatterns exhibit enhanced blood compatibility relative to controls.  相似文献   

16.
We describe a microfluidic device that can be used to detect interactions between red blood cells (RBCs) and endothelial cells using a gold pillar array (created by electrodeposition) and an integrated detection electrode. Endothelial cells can release nitric oxide (NO) via stimulation by RBC‐derived ATP. These studies incorporate on‐chip endothelial cell immobilization, direct RBC contact, and detection of NO in a single microfluidic device. In order to study the RBC‐EC interactions, this work used a microfluidic device made of a PDMS chip with two adjacent channels and a polystyrene base with embedded electrodes for creating a membrane (via gold pillars) and detecting NO (at a glassy carbon electrode coated with platinum‐black and Nafion). RBCs were pharmacologically treated with treprostinil in the absence and presence of glybenclamide, and ATP release was determined as was the resultant NO release from endothelial cells. Treprostinil treatment of RBCs resulted in ATP release that stimulated endothelial cells to release on average 1.8±0.2 nM NO per endothelial cell (average±SEM, n=8). Pretreatment of RBCs with glybenclamide inhibited treprostinil‐induced ATP release and, therefore, less NO was produced by the endothelial cells (0.92±0.1 nM NO per endothelial cell, n=7). In the future, this device can be used to study interactions between many other cell types (both adherent and non‐adherent cell lines) and incorporate other detection schemes.  相似文献   

17.
Chen Z  Adams MA 《Talanta》1998,47(3):779-786
A flow injection analysis of Ca(2+) and Mg(2+) using indirect potentiometric detection in natural waters is proposed, where Ca(2+) or Mg(2+) are injected into a buffer carrier containing phosphate, resulting in the formation of Ca(3)(PO(4))(2) or Mg(3)(PO(4))(2). The consequent reduction in free phosphate in the carrier solution is detected using a metallic cobalt wire electrode. Indirect electrode response was used and the experimental conditions affecting electrode response were optimized. Responses were linear in the concentration range 5x10(-4) to 5x10(-3) M with a detection limit of 1x10(-5) M in 20 mM phosphate buffer at pH 8.0. The relative standard derivation at 1 mM of Ca(2+) and Mg(2+) were 3.9 and 3.7% (n=10), respectively. EGTA and 8-hydroxyquinoline were used as the masking agents for Ca(2+) and Mg(2+), respectively. Concentrations of Ca(2+) and Mg(2+) in natural waters were successfully determined by the proposed method.  相似文献   

18.
Zn(2+) plays important roles in various biological systems; as a result, the development of tools that can visualize chelatable Zn(2+) has attracted much attention recently. We report here newly synthesized fluorescent sensors for Zn(2+), ZnAF-Rs, whose excitation maximum is shifted by Zn(2+) under physiological conditions. Thus, these sensors enable ratiometric imaging, which is a technique to reduce artifacts by minimizing the influence of extraneous factors on the fluorescence of a probe. Ratiometric measurement can provide precise data, and some probes allow quantitative detection. ZnAF-Rs are the first ratiometric fluorescent sensors for Zn(2+) that enable quantitative analysis under physiological conditions. ZnAF-Rs also possess suitable K(d) for applications, and high selectivity against other biologically relevant cations, especially Ca(2+). Using these probes, changes of intracellular Zn(2+) concentration in cultured cells were monitored successfully. We believe that these probes will be extremely useful in studies on the biological functions of Zn(2+).  相似文献   

19.
Zen JM  Kumar AS  Wang HF 《The Analyst》2000,125(12):2169-2172
Nafion/lead-ruthenate pyrochlore chemically modified electrode (NPyCME) showed a remarkable dual sensing activity toward NO2- oxidation and NO reduction as demonstrated by cyclic voltammetry (CV), ac-impedance spectroscopy and flow injection analysis (FIA). The mechanistic parameters of current function, charge transfer resistance and exchange current for the NPyCME, GCE and Nafion-coated GCE were evaluated and compared. The disproportionation reaction of NIIIO2- into NIVO3- + NIIO in acidic solution was used as a model system for testing the dual sensing ability of the NPyCME. The obtained crossover peak response for NO2- oxidation and NO reduction in pH 1.65 buffer solution gave the direct proof for the applicability of the NPyCME in the dual electrocatalytic action. By flow injection analysis, under optimized conditions, the calibration curve was linear in the range of 100 nM-100 microM and 800 nM-63.3 microM and the detection limit (S/N = 3) was 4.8 nM and 15.6 nM for NO2- and NO, respectively.  相似文献   

20.
Flowthrough enzyme electrodes are reported for determinations of alcohol, lactate and glutamate. Oxidoreductases mixed with immobilized NAD+ cofactor are held between a suitable platinum electrode and a semipermeable membrane. The coenzyme is readily regenerated either directly by electrochemical oxidation or by using phenazine methosulphate (PMS+) as intermediate. Continuous flow conditions are used. The sensitivity obtained with the alcohol dehydrogenase electrode was 50, 620 or 810 nA mol-1 of ethanol, respectively, when regeneration was done electrochemically or with 0.1 or 0.5 mM PMS+. The sensitivities for the lactate and glutamate sensors in the presence of 0.5 mM PMS+, were 14 and 50 nA mmol-1 for D,L-lactate and L-glutamate, respectively. The calibration curves were linear for concentrations up to 0.5, 1.5 and 100 mM of glutamate, lactate and ethanol, respectively. The sensitivity of the alcohol and lactate sensors decreased by 50–55% within 60 h and that of the glutamate sensor within 6 h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号