首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 513 毫秒
1.
We determined whether the accuracy of magnetic resonance angiography (MRA) in the peripheral run-off vessels can be improved by using contrast-enhanced (CE) three-dimensional (3D) technique in comparison to electrocardiograph (ECG)-triggered two-dimensional (2D) time-of-flight (TOF) technique. In a prospective study 20 patients with occlusions of the pelvic and/or femoral arteries underwent a CE 3D MRA (repetition time (TR): 5 ms, (TE) echo time: 2 ms, flip angle (FA): 30°) and an ECG-triggered 2D time-of-flight (TOF) technique (TR: 408 resp. 608 ms, TE: 7 ms, FA: 70°) of the run-off vessels on a 1.5 T MR system. Each patient received a contrast material volume of 0.15 mmol/kg of body weight of gadolinium (Gd)/DTPA using an automatic injector. The tube system to the patient was flushed by 50 mL of a saline solution applied with the same injection rate as the contrast material administration. The start of the 3D MR sequence was tailored individually to the applied contrast material after determination of circulation times by a prior bolus. All patients underwent each conventional or digital arteriography for comparison, as well. The visualization of the run-off vessels was ranked on a scale of 0–3 (0 = poor, 1 = fair, 2 = good, 3 = excellent) by three blinded reviewers. They also graded the vascular segments as either occluded or significantly altered (>50% reduction in diameter) or free of significant stenosis. CE 3D MRA was significantly faster in imaging the run-off vessels in comparison to the ECG-triggered 2D TOF technique. All 160 vascular segments were visualized with the 3D method, whereas only 142/160 segments were seen with 2D technique. The resulting image quality ranking of all vascular segments was significantly higher (p < 0.05) using CE 3D MRA (2.8) than with the 2D TOF technique (2.4). The detection of the stenoses was possible with both techniques. The grading of seven of seven stenoses was correct with 3D method and in five of seven cases with the 2D TOF technique. All vessel occlusions were detected by using both techniques. Small collaterals were visualized in more detail with the CE 3D MR angiography. These data demonstrate an improvement in image quality and accuracy of MRA of the peripheral arteries using a CE 3D technique in comparison to an ECG-triggered 2D TOF sequence.  相似文献   

2.
Demonstration of the initial results of breath-hold 3D MR coronary angiography with patients using a new intravascular contrast agent (feruglose). Contrast-enhanced 3D MR-coronary angiography was performed in 5 patients with coronary artery disease after administration of feruglose in three different doses (0.5 (n = 3), 2, 5 mg Fe/kg body weight for each patient). MR coronary angiography was performed with an ECG-triggered 3D-FLASH-sequence during breath-hold at 1.5 T (TR 6.8 ms, TE 2.5 ms, flip-angle 30 degrees ). To reduce data acquisition time, only the two anterior elements of the phased-array body coil were activated. The data acquisition window within the cardiac cycle ranged between 217-326 ms depending on the matrix. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of the coronary arteries were analyzed, and the results for the detection of coronary artery stenoses were compared with those obtained by conventional coronary angiography. SNR and CNR revealed an improved image quality at a dose of 2 mg Fe/kg compared with the lower dose, but no further improvement was obtained by rising the dose to 5 mg Fe/kg. Except for the left circumflex artery of one patient, at minimum the proximal parts of all four main coronary arteries could be imaged for all patients. Within the visible parts of the coronary arteries, six of eight significant coronary stenoses were identified correctly. Imaging of the proximal parts of the coronary arteries including detection of stenoses is possible during breath-hold using an intravascular contrast agent.  相似文献   

3.
The aim of this article was to obtain initial experiences with fluoroscopically triggered contrast-enhanced (CE) 3D MR DSA with elliptical centric k-space order and 3D time-of-flight (TOF) turbo MRA of the carotid arteries. In this prospective study we examined 16 consecutive patients with suspicion of atherosclerotic disease involving the carotid arteries. Ultrasound was available in all, x-ray angiography in 12, surgical correlation in 9, and intraoperative x-ray angiography in 4 patients. All examinations were done on a 1.5 T unit applying: transverse plain 3D TOF turbo MRA and coronal CE MRA with fluoroscopic triggering. Combining head and neck array coils allowed the visualization of supraaortic arteries from the aortic arch to the circle of Willis. MRA results (maximum intensity projections) were compared with x-ray angiography, ultrasound, and inspection of endarterectomy specimens. Volume rendering was performed in selected cases additionally. Agreement between CE MRA, 3D TOF turbo MRA and x-ray angiography regarding stenoses of the internal and external carotid artery was very good. CE MRA was able to detect correctly intracranial stenoses, but delineation of the aortic arch and proximal common carotid arteries was sometimes reduced. Volume rendering was suited for visualization of MRA images providing a realistic three-dimensional impression. In conclusion, high-resolution fluoroscopically triggered CE MRA as non-invasive technique is another important step on the way to replace invasive x-ray angiography for the evaluation of atherosclerotic carotid artery disease. High resolution 3D TOF turbo MRA might be a helpful adjunct to increase the diagnostic reliability for the carotid bifurcation.  相似文献   

4.

Background and Purpose

The use of magnetic resonance imaging (MRI) to assess the vascular nature of diseases such as multiple sclerosis (MS) is a growing field of research. This work reports on the application of MR angiographic (MRA) and venographic (MRV) techniques in assessing the extracranial vasculature in MS patients.

Materials and Methods

A standardized MRI protocol containing 2D TOF-MRV and dynamic 3D contrast-enhanced (CE) MRAV was run for 170 MS patients and 40 healthy controls (HC). The cross-sectional area (CSA) of the internal jugular veins (IJVs) was measured at three neck levels in all subjects for both MRV techniques to determine the presence of venous stenoses. All data were analyzed retrospectively.

Results

For the values where both methods showed signal, the 3D method showed larger CSA measurement values compared to 2D methods in both IJVs, in both MS and HC subjects which was confirmed with student paired t-tests. Of the 170 MS patients, 93 (55%) in CE-MRAV and 103 (61%) in TOF-MRV showed stenosis in at least one IJV. The corresponding numbers for the 40 HC subjects were 2 (5%) and 4 (10%), respectively. Carotid ectasias with IJV stenosis were seen in 26 cases (15%) with 3D CE-MRAV and were not observable with 2D TOF-MRV. Carotid ectasias were not seen in the HC group. In the 2D TOF-MRV data, banding of the IJVs related to slow flow was seen in 58 (34%) MS cases and in no HC cases. MS patients showed lower average CSAs than the HC subjects.

Conclusion

The 3D CE MRAV depicted the vascular anatomy more completely than the 2D TOF-MRV. However, the 3D CE MRAV does not provide any information about the flow characteristics which are indirectly available in the 2D TOF-MRV in those cases where there is slow flow.  相似文献   

5.
PURPOSE: The purpose of this study was to evaluate differences in the degrees of contrast enhancement effects of small hepatocellular carcinomas (HCCs) in patients with cirrhosis between helical computed tomography (CT) and magnetic resonance (MR) imaging during multiphasic contrast-enhanced dynamic imaging and to determine the diagnostic value of MR imaging especially in assessing hypovascular HCCs detected as hypoattenuating nodules on late-phase CT. SUBJECTS AND METHODS: This study included 64 small HCCs (<3 cm in diameter) in 40 patients with chronic hepatitis or cirrhosis who underwent multiphasic (arterial, portal and late phases) contrast-enhanced dynamic helical CT and MR imaging. The contrast enhancement patterns of each lesion in the arterial and late phases were evaluated by two radiologists experienced in liver MR imaging and categorized as one of five grades (1=hypoattenuated/hypointense; 2=slightly hypoattenuated/hypointense; 3=isoattenuated/isointense; 4=slightly hyperattenuated/hyperintense; 5=hyperattenuated/hyperintense), compared with the surrounding liver parenchyma. RESULT: Forty-three (67%) of 64 lesions showed Grade 4 (n=24) or Grade 5 (n=19) enhancement on arterial-phase CT, while 51 (80%) of 64 lesions showed Grade 4 (n=20) or Grade 5 (n=31) enhancement on arterial-phase MR imaging, indicating hypervascular HCCs. The grading score of hypervascular HCCs on arterial-phase MR imaging (mean: 4.61) was significantly (P<.01) higher than that for hypervascular HCCs on arterial-phase CT (mean: 4.20), showing better detection of the hypervascularity (arterial enhancement) of the lesion on arterial-phase MR imaging. Regarding hypovascular HCCs, all (100%) of 21 hypovascular HCCs on CT showed Grade 1 (n=10) or Grade 2 (n=11) enhancement on late-phase CT, seen as hypoattenuation. In contrast, 8 (62%) of 13 hypovascular HCCs on MR imaging showed Grade 1 (n=1) or Grade 2 (n=7) enhancement on late-phase MR imaging, seen as hypointensity. Grading scores of hypovascular HCCs on late-phase images were significantly (P<.001) lower on CT than on MR imaging (mean score: 1.52 vs. 2.31), indicating better washout effects for hypovascular HCCs on late-phase CT. CONCLUSION: The washout effects for small HCCs on late-phase MR imaging were inferior to those for small HCCs on late-phase CT. Especially, hypovascular HCCs demonstrated as hypoattenuating nodules on late-phase CT were often not seen on late-phase MR imaging, requiring careful evaluation of other sequences, including unenhanced T(1)-weighted and T(2)-weighted MR images.  相似文献   

6.
PurposeComputed tomography (CT) imaging is the standard to assess interstitial lung disease. Magnetic resonance (MR) is potentially advantageous due to superior tissue characterization and better assessment of blood flow dynamics. This study aimed to evaluate idiopathic pulmonary fibrosis (IPF) using prototype 4D Stack of Stars GRE (StarVIBE) MR and compare it to CT.MethodThis IRB-approved prospective study included 13 patients [5F:8M; average age 66 ± 8.1 years] with pulmonary fibrosis, and 12 healthy controls [3F:9M; average age 55 ± 3.6 years]. MR of the chest included noncontrast steady-state free precession imaging (SSFP) and free-breathing 4D StarVIBE sequence with intravenous contrast administration up to 160 s. The images were assessed for quality and artifacts. The image resolution was evaluated based on the visibility of the smallest bronchi, vessels, lymph nodes, and pleural fissures. Independent assessment of reticulation, ground-glass opacity, and traction bronchiectasis was performed and compared to CT.ResultsThe StarVIBE images had fewer artifacts and higher spatial resolution. The findings associated with IPF were significantly better seen with StarVIBE, with superior CT correlation.ConclusionContrast-enhanced free-breathing StarVIBE MR can generate high quality images with good correlation to CT in patients with IPF, and with high spatial and temporal resolution to generate rapid sequential dynamic images.  相似文献   

7.
A phantom with T1 and T2 relaxation times encompassing normal liver and liver lesions was constructed to evaluate fast magnetic resonance pulse sequences using TR from 21-100 milliseconds, TE 12-60 milliseconds and flip angles from 5 degrees-90 degrees. Ten of these fast MR sequences were then selected and compared with conventional spin-echo sequences in normal volunteers (n = 3) and in patients with liver lesions (n = 6). Subjectively, the fast MR sequences eliminated motion artefacts. Objectively, 8 of 10 fast sequences had signal-to-noise ratios comparable to spin-echo imaging whereas only 2 of 10 had contrast-to-noise ratios that were similar to spin-echo imaging. This preliminary study, performed at 1.5 Tesla, does not show any clear-cut advantage of fast imaging over spin-echo imaging in the detection of liver lesions. The use of a liver tissue equivalent phantom provides a rapid, practical approach in evaluation of fast scans.  相似文献   

8.
To determine whether differences exist between neurofibromatosis type 1 (NF1) patients with or without focal lesions and healthy normal volunteers in the metabolite ratios of normal appearing white matter, 27 patients with NF1 (with parenchymal lesion, MR positive, n: 17; without parenchymal lesions, MR negative, n: 10) and 20 healthy volunteers underwent MRI and short TE (31 ms) proton MR spectroscopy (MRS). In 17 patients with parenchymal lesions, 61 focal lesions were detected by MRI. MRS was performed from normal appearing frontal and posterior parietal white matter (FWM and PWM) in NF1 and from control groups. NAA/Cr, Cho/Cr and MI/Cr ratios were calculated. Significant increase in Cho/Cr and MI/Cr ratios were found in FWM and PWM in MR negative and positive groups when compared to control group. NAA/Cr ratio in MR positive group was significantly decreased in FWM compared to control group. There were no significant differences between FWM and PWM in all metabolite ratios of MR negative group. MI/Cr ratio in MR positive group was significantly elevated in PWM compared to FWM. Metabolite changes detected by MRS could indicate demyelination and gliosis in normal appearing white matter in all NF1 patients, and additionally neuroaxonal damage in the FWM of NF1 patients with focal lesions. For that reason, in the clinical evaluation and follow-up of these patients MRS features of normal appearing white matter should be considered in addition to focal lesions.  相似文献   

9.
In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semi-automatically in maximum intensity projections (MIPs) of contrast-enhanced T1-weighted 3D spoiled gradient-echo datasets, studied with digital subtraction techniques. In vivo, the complete peripheral arterial bed of six patients was studied, from the aorto-iliac bifurcation down to the distal run-off. By measuring the signal intensity (SI) over the lumen of a vessel in the MIP, an SI-plot was obtained. Next, the vessel boundaries were determined using a threshold algorithm; from these boundary points individual diameter values could be obtained along the trajectory of the vessel. In an in vitro study, an optimal threshold value of 30% of the range of SI-values between the background and the maximal SI in the vessel was obtained for accurate diameter measurement in Gd CE MRA (i.e., full-width 30%-maximum). Furthermore, the relationship between the accuracy of these measurements and the scan resolution was investigated. Accuracy was found to be acceptable (i.e., less than 10% over/underestimation) for vessel sizes covering at least 3 pixels. In six patients, diameters were measured in MIPs of the total datasets (i.e., D(T)) as well as in selective MIPs of the clipped datasets (i.e., D(S)) (n = 209). D(T) and D(S) were statistically significantly correlated (p < 0.01) with a Pearson correlation coefficient rP = 0.98. Measurements in the total MIPs yielded statistically significant (p < 0.01) smaller diameter values compared with measurements in selective MIPs, with a mean difference of 0.15 mm. Diameter values from the selective MIPs of the aorto-iliac arteries were also compared with diameter values measured at corresponding anatomic positions in X-ray angiograms of these patients (i.e., D(x)) (n = 70). D(X) and D(S) were statistically significantly correlated (p < 0.01) with a Pearson correlation coefficient rP = 0.92. Diameters measured in the selective MIPs were smaller than those measured in the X-ray angiograms (mean difference 0.49 mm) and this difference was statistically significant (p < 0.01). In conclusion, diameter values can be evaluated accurately in MIPs of vessels with at least 3 pixels in diameter, using the full-width 30%-maximum criterion.  相似文献   

10.
Previous echocardiographic and experimental animal studies have shown that cardiac function, structure, and metabolism change with age. The aim of this study was to evaluate the impact of age on left ventricular high-energy phosphate metabolism. Using a 1.5 Tesla whole-body MR scanner 31P 2D CSI (8 x 8 phase encoding steps, 320 mm field of view) was performed in 76 healthy male volunteers (41.7 +/- 13 years) without any history of coronary heart disease. Fourier interpolation, corrections for T1 saturation effects, the nucleus Overhauser effect, and the blood contamination were applied to the spectroscopic data. The volunteers were divided into two groups, younger (n = 37) and older (n = 39) than 41.7 years. In all volunteers, laboratory specimen were sampled, and transthoracal echocardiography was carried out. Significant differences in left ventricular phosphocreatine (PCr) to beta-adenosine-triphosphate (beta-ATP) ratios (2.16 vs. 1.83, p < 0.001), fasting serum glucose levels (83.3 vs. 98.7 mg/dl, p < 0.001), E/A (1.51 vs. 1.14 p < 0.001), and ejection fraction (EF, 65.3 vs. 59.9%, p = 0.005) were detected between the two groups of volunteers, younger and older than 41.7 years. Moreover, age correlated moderately to well with left ventricular PCr to beta-ATP ratios (r = -0.44), fasting serum glucose levels (r = 0.4), E/A (r = -0.7), left ventricular myocardial mass (r = -0.41), and EF (r = -0.55). In conclusion, our study shows that left ventricular PCr to beta-ATP ratios decrease moderately with age, as suggested by previous experimental animal studies. Additionally, age correlates negatively with E/A, left ventricular myocardial mass, and EF, as reported by previous echocardiography studies. The present study is the first to show the impact of age on left ventricular PCr to beta-ATP values in humans.  相似文献   

11.
PurposeTo investigate three MR pulse sequences under high-frequency noninvasive ventilation (HF-NIV) at 3 T and determine which one is better-suited to visualize the lung parenchyma.MethodsA 3D ultra-short echo time stack-of spirals Volumetric Interpolated Breath-hold Examination (UTE Spiral VIBE), without and with prospective gating, and a 3D double-echo UTE sequence with spiral phyllotaxis trajectory (3D radial UTE) were performed at 3 T in ten healthy volunteers under HF-NIV. Three experienced radiologists evaluated visibility and sharpness of normal anatomical structures, artifacts assessment, and signal and contrast ratio computation. The median of the three readers‘scores was used for comparison, p < .05 was considered statistically significant. Incidental findings were recorded and reported.ResultsThe 3D radial UTE resulted in less artifacts than the non-gated and gated UTE Spiral VIBE in inferior (score 3D radial UTE = 3, slight artifact without blurring vs. score UTE Spiral VIBE non-gated and gated = 2, moderate artifact with blurring of anatomical structure, p = .018 and p = .047, respectively) and superior lung regions (score 3D radial UTE = 3, vs. score UTE Spiral VIBE non-gated = 2.5, p = .48 and score UTE Spiral VIBE gated = 1, severe artifact with no normal structure recognizable, p = .014), and higher signal and contrast ratios (p = .002, p = .093). UTE Spiral VIBE sequences provided higher peripheral vasculature visibility than the 3D radial UTE (94.4% vs 80.6%, respectively, p < .001). The HF-NIV was well tolerated by healthy volunteers who reported on average minor discomfort. In three volunteers, 12 of 18 nodules confirmed with low-dose CT were identified with MRI (average size 2.6 ± 1.2 mm).ConclusionThe 3D radial UTE provided higher image quality than the UTE Spiral VIBE. Nevertheless, a better nodule assessment was noticed with the UTE Spiral VIBE that might be due to better peripheral vasculature visibility, and requires confirmation in a larger cohort.  相似文献   

12.
BACKGROUND: Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. OBJECTIVE: To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). METHODS: MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. RESULT: Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. CONCLUSION: Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.  相似文献   

13.
The purpose of this study was to examine if an unusual bilaminar pattern of lateral tibial condyle cartilage layer on the fat-suppressed three-dimensional (3D) spoiled gradient echo sequence is artifactual or correlates with structural and/or biochemical composition of cartilage. The laminar appearance of the lateral tibial condyle cartilage layer was studied on fat-suppressed 3D spoiled gradient echo MR images of the knee joint in 67 patients (mean age: 28y) performed at 1.0 Tesla. After i.v. administration of gadopentetate dimeglumine, diffusion of the contrast media into cartilage layer was qualitatively analysed over time on inversion recovery spin echo images of knee joints of five asymptomatic volunteers (mean age: 25y). In a patient with osteosarcoma and total knee replacement, MR examination of cartilage layer of lateral tibial plateau was compared with histologic specimens stained with Safranin-O, demonstrating proteoglycan distribution in cartilage. The retrospective analysis of 67 knee joints revealed a bilaminar appearance of lateral tibial condyle cartilage layer in the gradient echo images in the majority of cases (81%) with a statistically significant tendency to a trilaminar pattern in patients older than 20 years. With i.v. contrast administration, the contrast enhancement was only observed in the superficial zone of tibial cartilage layer. Histologic specimens in one patient demonstrated a good correlation between thickness of proteoglycan-free and proteoglycan-rich laminae of lateral tibial condyle on Safranin-O staining with hyperintense and hypointense zones, respectively, on corresponding fat-suppressed 3D spoiled gradient echo images (correlation coefficient of 0.87). Bilaminar pattern of tibial condyle cartilage layer on fat-suppressed 3D spoiled gradient echo images in younger subjects is not an artifact or an intrachondral lesion, but it may represent a regional difference in composition of extracellular cartilage matrix possibly produced by a highly-oriented collagen fiber structure associated with a high concentration of proteoglycans in the middle and deep portion of the cartilage layer.  相似文献   

14.
We conducted MR evaluations of acetabular and femoral cartilages in 27 hips of patients with osteoarthritis and 10 hips of normal volunteers by a fat-suppressed three-dimensional (3D) pulse sequence using a continuous leg traction method, and correlated the results with radiographic assessment. Normal condition of the acetabular and femoral cartilages was clearly demonstrated in the normal volunteers. Grading of abnormalities was possible for each cartilage in the patients with osteoarthritis. In early osteoarthritis graded by radiography, a high prevalence of abnormalities was detected in the acetabular cartilage as compared with the femoral cartilage. Despite the structural difficulty in evaluation of the hip joint cartilage, our MR imaging technique can provide information concerning a wide spectrum of cartilage abnormalities even in the identical radiographic stage, which will lead to improvement in the evaluation of disease progression and in surgical planning.  相似文献   

15.
Recent developments in high-resolution MR imaging techniques have opened up new perspectives for structural characterization of trabecular bone by non-invasive methods. In this study, 3-D MR imaging was performed on 17 healthy volunteers and 6 osteoporotic patients. Two different MR sequences were used to evaluate the impact on MR acquisition on texture analysis results. Images were analyzed with four automated methods of texture analysis (grey level histogram, cooccurrence, runlength and gradient matrices) enabling quantitative analysis of grey level intensity and distribution within three different regions of interest (ROI). Texture analysis is not very frequently used since the interpretation of the large number of calculated parameters is difficult. We applied multiparametric data analyses such as principal component analysis (CFA) and hierarchical ascending classification (HAC) to determine the relevant parameters to differentiate between three sets of images (healthy young volunteers, healthy postmenopaused and osteoporotic patients). The results suggest that relevant texture information (depending on the ROI localization in the calcaneus) can be extracted from calcaneus MR images to evaluate osteoporosis and age effects on trabecular bone structure if strictly the same acquisition sequences are used for all patients' examination.  相似文献   

16.
Magnetization transfer (MT) technique is a promising method in differential diagnosis of diseases in parenchymal tissues. Basic knowledge about circumstances and elementary factors that influence MT and its parameters is still insufficient, however. Having a meal before the magnetic resonance (MR) examination could change liver MT parameters compared to fasting state through alteration in liver perfusion, blood flow, and content of portal blood (proteins and other derivates from a meal). If MT parameters can be altered by a meal, then MR liver studies should always be performed after fasting. Before MRI examinations we examined three healthy volunteers after a high-fat meal with Doppler ultrasound technique to find out duration and magnitude of changes in portal blood flow. Duration of ≥50% increased peak-flow value compared to fasting state in portal vein was >90 min, which is enough for our MR examination. With a low-field 0.1-T MR imager we examined 10 healthy volunteers after a short (range from 3 h 45 min to 17 h 30 min) fast and also immediately after a high-fat meal. Magnetization transfer parameters, magnetization transfer ratio (MTR) and magnetization transfer rate Rwm of liver tissue were determined. MTR changed significantly (Student paired two-tailed t-test, p = .0044) after a meal, but Rwm did not (p = .0952). We recommend a 4 h fast before MR examination that aims to determine the MTR of liver tissue.  相似文献   

17.
In this work, we present the first triple quantum filtered (TQF) sodium MR images of the human knee joint in vivo. A 3D TQF data set of 16 slices was obtained in 20 min using a TQF pulse sequence preencoded to a twisted projection imaging readout. Images clearly demarcate patellar cartilage and also demonstrate fluid signal suppressed by the triple quantum filter. Biexponential transverse relaxation times were calculated by fitting the TQF free induction decay to a theoretical signal expression. The average values from three healthy volunteers were T(2fall)(*) = 9.59 +/- 0.35 ms and T(2rise)(*) = 0.84 +/- 0.06 ms. Application of TQF imaging in biological tissues is discussed.  相似文献   

18.
To improve vessel contrast in high-resolution susceptibility-based brain venography, an automatic phase contrast enhancing procedure is proposed, based on a new phase mask filter suitable for maximizing contrast of venous MR signals. The effectiveness of the new approach was assessed both on digital phantoms and on acquired MR human brain images, and then compared with venographic results of phase masking methods in recent literature. The digital phantom consisted of a simulated MR dataset with given signal-to-noise ratios (SNRs), while real human data were collected by scanning healthy volunteers with a 3.0-T MR system and a 3D gradient echo pulse sequence. The new phase mask (NM) was more effective than the conventional mask (CM) both on the digital phantoms and on the acquired MR images. A quantitative comparison based on phantom venograms indicates how this phase enhancement can lead to a significant increase in the contrast-to-noise ratio (CNR) for all considered phase values as well as for all vessel sizes of clinical interest. Likewise, the in vivo brain venograms reveal a better depiction of the smallest venous vessels and the enhancement of many details undetectable in conventional venograms.  相似文献   

19.
Soumen Saha 《Molecular physics》2015,113(19-20):3031-3041
The current study describes the development of a general equation of cooperativity energy (CE) for an n-mer system based on the difference between interaction energy of the system and the sum of interaction energy of its dimeric subunits. The counterpoise corrected generalised CE equation of n-mer system has also been developed. In order to validate these two generalised equations, we have considered four different kinds of water clusters, viz. W1D, W2D, W2D-H and W3D, ((H2O)n: n = 3–10), with the increasing cluster size as well as changing arrangements. The CE obtained from the two generalised equations follow the trend W3D > W2D-H > W2D > W1D. The deviation at n = 6 for W3D clusters in the plot of CE with cluster size has also been observed for O–H stretching frequencies, electron density and the Laplacian of the electron density plots. The contrastingly higher CE for cyclic pentamer compared to hexamer is in accordance with earlier observations as well as computed average hydrogen bond lengths. We have observed that the average charge value is more on oxygen atoms of pentamer than hexamer resulting in the shortening of hydrogen bond in pentamer and hence the CE values are more for pentamer than hexamer. We have shown that CE has the capability to quantify the cooperativity effect in water clusters.  相似文献   

20.
PURPOSE: The aim of this study was to evaluate the frequency and magnetic resonance imaging (MRI) features of clinically benign, small (<2 cm) hyperintense hepatic lesions in the cirrhotic liver on T1-weighted MR images seen at serial MRI. MATERIALS AND METHODS: This study included 189 patients with cirrhosis, who underwent hepatic MRI more than twice with an interval of at least 12 months. The initial MR images were reviewed for the presence of small hyperintense lesions on T1-weighted images. The size, location and signal intensity on T2-weighted images as well as enhancement patterns of the corresponding lesions were recorded. RESULTS: On the initial T1-weighted MR images, 43 small hyperintense hepatic lesions were detected in 23 (12%) of 189 patients. Twelve (28%) of 43 lesions showed early enhancement and were pathologically diagnosed as hepatocellular carcinoma (HCC) during the follow-up period. Thirty-one (72%) of 43 lesions showed no early enhancement with various signal intensity on T2-weighted images (hyperintensity=4, isointensity=20, hypointensity=7). Among these 31 lesions, 12 showed no interval change, while 11 disappeared (n=10) or decreased in size (n=1). In the remaining eight lesions, seven were diagnosed as HCC on the basis of pathologic confirmation or the interval growth. CONCLUSION: Small hyperintense hepatic lesions on T1-weighted magnetic resonance (MR) images without early enhancement on the arterial-phase contrast-enhanced dynamic studies in patients with cirrhosis usually showed no interval growth or disappeared during the serial MRI. These lesions with additional findings of iso- or hypointensity on the T2-weighted MR images without "washout effect" on the contrast-enhanced equilibrium-phase images may more frequently be clinically benign or hyperplastic nodules than HCCs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号