首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
In this article, we demonstrate a novel approach to implementing multiplex enzyme-linked immunosorbent assay (ELISA) in a single microfluidic channel by exploiting the slow diffusion of the soluble enzyme reaction product across the different assay segments. The functionality of the reported device is realized by creating an array of ELISA regions within a straight conduit that are selectively patterned with chosen antibodies/antigens via a flow-based method. The different analytes are then captured in their respective assay segments by incubating a 5-μL aliquot of sample in the analysis channel for an hour under flow conditions. Once the ELISA surfaces have been prepared and the enzyme substrate introduced into the analysis channel, it is observed that the concentration of the soluble enzyme reaction product (resorufin) at the center of each assay region grows linearly with time. Further, the rate of resorufin generation at these locations is found to be proportional to the concentration of the analyte being assayed in that segment provided that the ELISA reaction time in the system (τ R ) is kept much shorter than that required by the resorufin molecules to diffuse across an assay segment (τ D ). Under the operating condition τ R  << τ D , the reported device has been shown to have a 35% lower limit of detection for the target analyte concentration compared with that on a commercial microtiter plate using only a twentieth of the sample volume.  相似文献   

2.
3.
In this article, we report the design of a microchip based hydraulic pump that employs a sodium silicate derived sol–gel structure for generating pressure-driven flow within a microfluidic network. The reported sol–gel structure was fabricated in a chosen location of our device by selectively retaining sodium silicate solution within a sub-micrometer deep segment via capillary forces, and then providing the precursor material appropriate thermal treatment. It was shown that while the molecular weight cut-off for these membranes is at least an order of magnitude smaller than their photo-polymerized counterparts, their electrical conductance is significant. Moreover, unlike their polymeric counterparts these structures were found to be capable of blocking electroosmotic flow, thereby generating a pressure-gradient around their interface with an open microchannel upon application of an electric field across the microchannel–membrane junction. In this work, a fraction of the resulting hydrodynamic flow was successfully guided to an electric field-free analysis channel to implement a pressure-driven assay. Our experiments show that the pressure-driven velocity produced in the analysis channel of our device varied linearly with the voltage applied across the sol–gel membrane and was nearly independent of the cross-sectional dimensions of the membrane and the microfluidic channels. With our current design pressure-driven velocities up to 1.7 mm/s were generated for an applied voltage of 2 kV, which easily covers the range of flow speeds that can minimize the plate height in most microfluidic separations. Finally, the functionality of our device was demonstrated by implementing a reverse phase chromatographic separation in the analysis channel of our device using the pressure-driven flow generated on-chip.  相似文献   

4.
Fluorescence polarization (FP) assays incorporated with fluorophore-labeled aptamers have attracted great interest in recent years. However, detecting small molecules through the use of FP assays still remains a challenge because small-molecule binding only results in negligible changes in the molecular weight of the fluorophore-labeled aptamer. To address this issue, we herein report a fluorescence polarization (FP) aptamer assay that incorporates a novel signal amplification strategy for highly sensitive detection of small molecules. In the absence of adenosine, our model target, free FAM-labeled aptamer can be digested by nuclease, resulting in the release of FAM-labeled nucleotide segments from the dT-biotin/streptavidin complex with weak background signal. However, in the presence of target, the FAM-labeled aptamer–target complex protects the FAM-labeled aptamer from nuclease cleavage, allowing streptavidin to act as a molar mass amplifier. The resulting increase in molecular mass and FP intensity of the aptamer–target complex provides improved sensitivity for concentration measurement. The probe could detect adenosine from 0.5 μM to 1000 μM, with a detection limit of 500 nM, showing that the sensitivity of the probe is superior to aptamer-based FP approaches previously reported for adenosine. Importantly, FP could resist environmental interferences, making it useful for complex biological samples without any tedious sample pretreatments. Our results demonstrate that this dual-amplified, aptamer-based strategy can be used to design fluorescence polarization probes for rapid, sensitive, and selective measurement of small molecules in complicated biological environment.  相似文献   

5.
In this work, we report Escherichia coli O157:H7 detection using antibody-immobilized capillary reactors, enzyme-linked immunosorbent assay (ELISA), and a biochip system. ELISA selective immunological method to detect pathogenic bacteria. ELISA is also directly adaptable to a miniature biochip system that utilizes conventional sample platforms such as polymer membranes and glass. The antibody-immobilized capillary reactor is a very attractive sample platform for ELISA because of its low cost, compactness, reuse, and ease of regeneration. Moreover, an array of capillary reactors can provide high-throughput ELISA. In this report, we describe the use of an array of antibody-immobilized capillary reactors for multiplex detection of E. coli O157:H7 in our miniature biochip system. Side-entry laser beam irradiation to an array of capillary reactors contributes significantly to miniaturized optical configuration for this biochip system. The detection limits of E. coli O157:H7 using the ELISA and Cy5 label-based immunoassays were determined to be 3 and 230 cells, respectively. This system shows capability to simultaneously monitor multifunctional immunoassay and high sensitive detection of E. coli O157:H7.  相似文献   

6.
Lao AI  Hsing IM 《Lab on a chip》2005,5(6):687-690
DNA separation is typically done by gel electrophoresis based on its charge property. In our previous work, we reported that dielectrophoresis could be used to manipulate polystyrene nanoparticles' motion by using a miniaturized electrical field flow fractionation device (micro-EFFF) with a segmented electrode operated under a pulsed voltage (PV). In this work, we report the manipulation and separation of DNA molecules using the micro-EFFF. DNA motion was in situ visualized inside the device. Results revealed that dielectrophoresis governed DNA motion, which was strongly correlated with the pulse frequency but not the duty cycle of a PV. A longer retention time of DNA molecules was measured under a PV. The retention time increased with the length of DNA molecules. As the micro-EFFF is flow-based and sieving-matrix-free, it has a potential to be applied to sample preparation in a micrototal analysis system or when fractionated molecules are needed for downstream analysis.  相似文献   

7.
In this article, we demonstrate a novel approach to enhancing the sensitivity of enzyme-linked immunosorbent assays (ELISA) through pre-concentration of the enzyme reaction product (resorufin/4-methylumbelliferone) in free solution. The reported pre-concentration was accomplished by transporting the resorufin/4-methylumbelliferone molecules produced in the ELISA process towards a high ionic-strength buffer stream in a microfluidic channel while applying a voltage drop across this merging region. A sharp change in the electric field around the junction of the two liquid streams was observed to abruptly slow down the negatively charged resorufin/4-methylumbelliferone species leading to the reported pre-concentration effect based on the field amplified stacking (FAS) technique. It has been shown that the resulting enhancement in the detectability of the enzyme reaction product significantly improves the signal-to-noise ratio in the system thereby reducing the smallest detectable analyte concentration in the ELISA method. Applying the above-described approach, we were able to detect mouse anti-BSA and human TNF-α at concentrations nearly 60-fold smaller than that possible on commercial microwell plates. For the human TNF-α sample, this improvement in assay sensitivity corresponded to a limit of detection (LOD) of 0.102 pg mL−1 using the FAS based microfluidic ELISA method as compared to 7.03 pg mL−1 obtained with the traditional microwell plate based approach. Moreover, because our ELISAs were performed in micrometer sized channels, they required sample volumes about two orders of magnitude smaller than that consumed in the latter case (1 μL versus 100 μL).  相似文献   

8.
Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 μm polystyrene particles, 5 μm polystyrene particles, 5 μm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.  相似文献   

9.
In this study, we report the design of a microchip‐based hydraulic pump that comprises three glass conduits arranged in a T‐geometry, one of which has a 2 mm long segment shallower (0.5–3 μm in depth) than the remaining 15 μm deep microfluidic network. Upon application of an electric field across this microchannel junction, a mismatch in EOF rate is introduced due to a differential in the fluid conductivity across the deep and shallow segments. Using the reported micropump, pressure‐driven velocities up to 3.2 mm/s have been generated in a 15 μm deep separation channel for an applied voltage of 1.75 kV allowing us to operate under separation conditions that yield the minimum plate height. Moreover, we have shown that this flow velocity can be maximized by optimizing the depth in the shallow region of the T‐geometry. Interestingly however, a simple theory accounting for fluid conductivity differences across microchannels of different depths significantly underestimates the pressure‐driven velocities observed in our experiments. The Taylor dispersion coefficient in our system on the other hand compares well with the theoretical predictions reported in the literature. Finally, the functionality of our device has been demonstrated by implementing a reverse‐phase chromatographic separation that was driven by the pressure‐driven flow generated on‐chip.  相似文献   

10.
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4–6 for the analyte peaks in a 3 cm long analysis channel.  相似文献   

11.
A number of life-saving drugs require therapeutic drug monitoring (TDM) for safe and effective use. Currently, however, TDM is performed using sophisticated analytical techniques relegated to central labs, increasing the cost per test and time to answer. Here, using a novel vertical flow membrane system with inkjet-printed surface enhanced Raman sensors, along with a portable spectrometer, we demonstrate a low cost and easy to use device to quantify levels of flucytosine, an antifungal that requires TDM for effective patient care, from undiluted human serum. To our knowledge, this work represents the first report of a passive vertical flow sample cleanup method with surface enhanced Raman detection. We first investigated and optimized the parameters of the vertical flow system for the detection of flucytosine in spiked serum samples. Then, using an optimized vertical-flow system utilizing nitrocellulose membranes and a paper SERS sensor, we achieved detection of down to 10 μg mL−1 flucytosine in undiluted serum, with quantitative detection across the entire therapeutic range. This system reduces the assay time to about 15 min, far quicker than the current gold standards. We anticipate that this novel system will enable near-patient therapeutic drug monitoring, leading to the safe and effective administration of a number of life-saving drugs. Furthermore, it will spawn the development of SERS detection systems capable of separating target analytes from real-world biological matrices.  相似文献   

12.
The olive fruit fly pheromone avidin-biotin ELISA immunoassay, based on the use of polyclonal G antibodies derived from rabbits (reported previously) and a newer assay, based on the use of polyclonal Y antibodies isolated from the eggs of laying hens (reported in this paper), were applied successfully for the analysis of natural pheromone in virgin adult female olive fruit flies. According to the results obtained, the pheromone content in the glands of adult female olive fruit flies increases from the third to the ninth day of their age. During the calling period, the female olive fruit flies seem to emit approximately 1.1microg pheromone/insect/day at least. The immunoassay, based on the Y antibodies, is slightly more sensitive (detection limit 40ng/mL) than the assay based on polyclonal anti-pheromone rabbit antiserum (detection limit 80ng/mL). As revealed by thorough cross-reactivity studies, including 14 structurally similar to the olive fruit fly pheromone molecules, the newer immunoassay is less selective than the previous one and seems to cross react with few molecules bearing the spiroketal moiety.  相似文献   

13.
Zhou F  Wang M  Yuan L  Cheng Z  Wu Z  Chen H 《The Analyst》2012,137(8):1779-1784
The availability of techniques for the sensitive detection of early stage cancer is crucial for patient survival. Our previous research (Langmuir, 2011, 27, 2155-2158) showed that gold nanoparticle layers (GNPL) used in indirect format ELISA amplified the signal, and gave a lower limit of detection (LOD) compared with commercial ELISA plates. However, due to its intrinsic limitations, indirect ELISA is not suitable for samples of complex composition, such as serum, plasma, etc., thus limiting the clinical performance of this kind of ELISA. In the work reported here, a GNPL-based sandwich format ELISA was developed, which showed superiority in terms of detection limit and sensitivity in the determination of rabbit IgG in buffer. More importantly, experiments using plasma spiked with carcinoembryonic antigen (CEA) as a representative biomarker showed that our GNPL-based ELISA assay amplified the signal and lowered the LOD compared to other assays, including commercialized CEA ELISA kits. This simple and cost-effective GNPL-based sandwich ELISA holds promise in clinical applications.  相似文献   

14.
We propose a strategy for optimizing distribution of flow in a microfluidic chamber for microreactor, lateral flow assay and immunocapture applications. It is aimed at maximizing flow throughput, while keeping footprint, cell thickness, and shear stress in the distribution channels at a minimum, and offering a uniform flow field along the whole analysis chamber. In order to minimize footprint, the traditional tree-like or "rhombus" design, in which distribution microchannels undergo a series of splittings into two subchannels with equal lengths and widths, was replaced by a design in which subchannel lengths are unequal, and widths are analytically adapted within the Hele-Shaw approximation, in order to keep the flow resistance uniform along all flow paths. The design was validated by hydrodynamic flow simulation using COMSOL finite element software. Simulations show that, if the channel is too narrow, the Hele-Shaw approximation loses accuracy, and the flow velocity in the chamber can fluctuate by up to 20%. We thus used COMSOL simulation to fine-tune the channel parameters, and obtained a fluctuation of flow velocity across the whole chamber below 10%. The design was then implemented into a PDMS device, and flow profiles were measured experimentally using particle tracking. Finally, we show that this system can be applied to cell sorting in self-assembling magnetic arrays, increasing flow throughput by a factor 100 as compared to earlier reported designs.  相似文献   

15.
Molecular transport under the conditions of single-file diffusion was investigated near the channel boundaries by using dynamic Monte Carlo and molecular dynamics simulations of tracer exchange between single-file channels and their surroundings. The boundary effect reported in our recent papers (Vasenkov S.; K?rger, J. Phys. Rev. E 2002, 66, 052601. Schüring, A.; Vasenkov S.; Fritzsche, S. J. Phys. Chem. B 2005, 109, 16711) was studied in detail. This boundary effect is characterized by deviations of the intrachannel concentration profiles of tracer molecules observed in the case of single-file diffusion near the channel boundaries from the corresponding profiles typical for normal diffusion. It has been shown in our previous studies that these deviations occur under the conditions when the potential-energy difference inside and outside of single-file channels was both comparable and much larger than the activation energy of intrachannel diffusion. Here, we report a quantitative model describing the boundary effect. According to this model, an occurrence of the boundary effect is related to a complex character of diffusion in finite single-file systems. Such diffusion can be described by the following two types of movements occurring in parallel: (i) correlated displacements of all molecules in any particular channel and (ii) fast displacements of single molecules, which are uncorrelated with the displacements of all other molecules in the same channel. The latter displacements are restricted to a certain length interval that depends on the channel length and the channel occupancy. This length interval is shown to determine the extensions of the channel margins where the boundary effect is observed.  相似文献   

16.
Sample pre-concentration by isotachophoresis in microfluidic devices   总被引:1,自引:0,他引:1  
We have designed microfluidic devices with the aim of coupling isotachophoresis (ITP) with zone electrophoresis (ZE) as a method to increase the concentration limit of detection in microfluidic devices. We used plastic multi-channel chips, designed with long sample injection channel segments, to increase the sample loading. The chip was designed to allow stacking of the sample into a narrow band by discontinuous ITP buffers and subsequent separation in the ZE mode. In the ITP-ZE mode, with a 2-cm long sample injection plug, sensitivity was increased by 400-fold over chip ZE and we found that the separation performance after the ITP stacking was comparable to that of regular chip ZE. We report sub-picomolar limits of detection of fluorescently labeled ACLARA eTag reporter molecules electrokinetically injected from cell lysate sample matrixes containing moderate salt concentrations. We evaluated sample injections from buffers with varied ionic strengths and found that efficient stacking and separations were obtained in both low and high conductivity buffers, including physiological buffer with at least 140 mM salt. We applied ITP-ZE to the analysis of a cell surface protease (ADAM 17) which used live intact cells in physiological buffers with detection limits below 10 cells/assay.  相似文献   

17.
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05–50 μg/L. The analytical performance and figure of merits were compared to liquid chromatography–tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 μg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.   相似文献   

18.
Detection of pollutants is of significant importance for environmental protection. However, conventional monitoring methods are often time-consuming, and require expensive equipments. Biosensors based on enzyme linked immunosorbent assay (ELISA) provide an alternative method to conventional ones. In this research, the reduction in the size of ELISA utilizing micro-chemical reaction is described in a micro-flow immunosensor chip. The immunosensor chips were fabricated by micro-electromechanical system (MEMS) technology. The quantitative determination of coplanar polychlorinated biphenyls (Co-PCBs) was performed by using a micro-flow immunosensor chip. Polystyrene beads were used as the solid substrate for the immobilization of Co-PCB antibody. The antibody-immobilized beads were introduced into the flow channel. As a competitive ELISA, sample solution mixed with horseradish peroxidase (HRP) conjugated antigen, and non-HRP conjugated antigen was allowed to react in the flow channel. After the antigen-antibody reaction, addition of phosphate buffer solution containing hydrogen peroxide and the fluorogenic substrate produced a fluorescent dye, which was monitored with the resulting change in the fluorescence intensity. By using our micro-flow immunosensor chip, it was possible to determine the sensing range of Co-PCB derivatives up to 0.1 ppt in 30 s. This immunosensor chip had a wide linear range for Co-PCB detection from 0.1 pg/ml to 1.0 μg/ml. The regression analysis provided the correlation coefficients of r = 0.982−0.964 with good reproducibility and precision. In a series of five measurements with immunosensor chips prepared with a new batch of antibody-immobilized polystyrene beads, a relative standard deviation of 21.3% was obtained. Our immunosensor chip design reported here has the potential to be implemented to several different detection methodologies for numerous analytes.  相似文献   

19.
Matrix components are known to significantly alter the ionization of a target analyte in ESI-based measurements particularly when working with complex biological samples. This issue however may be alleviated by extracting the analyte of interest from the original sample into a relatively simple matrix compatible with ESI mass-spectrometric analysis. In this article, we report a microfluidic device that enables such extraction of small peptide molecules into an ESI-compatible solvent stream significantly improving both the sensitivity and reproducibility of the measurements. The reported device realizes this analyte extraction capability based on the free-flow zone electrophoretic fractionation process using a set of internal electrodes placed across the width of the analysis channel. Employing lateral electric fields and separation distances of 75 V/cm and 600 µm, respectively, efficient extraction of the model peptide human angiotensin II was demonstrated allowing a reduction in its detection limit by one to three orders of magnitude using the ESI-MS method. The noted result was obtained in our experiments both for a relatively simple specimen comprising DNA strands and angiotensin II as well as for human serum samples spiked with the same model peptide.  相似文献   

20.
《中国化学快报》2023,34(4):107715
Liquid chromatography tandem mass spectrometry (LC-MS/MS) plays an important role in clinical diagnostics. Although LC-MS/MS is superior in terms of accurately quantifying molecules in complex matrices, instrument footprint, operation and maintenance complexity also hinder its expansion as the analytical technique of choice. In this study, a compact LC-MS instrument was developed, in which an assembled liquid chromatograph was coupled with a miniature ion trap mass spectrometer. The overall instrument has a footprint of 69 cm × 31 cm × 31 cm, and it requires no gas supply as well as minimum maintenance. Furthermore, the use of LC-MS is in accord with conventional clinical diagnostic protocols, and the choice of ion trap offers tandem MS performance. The results showed that the use of LC could improve both mixture analysis capability and detection sensitivity of the miniature mass spectrometer. After optimization, feasibility of this instrument in clinical practice was demonstrated by the quantitation of four widely used immunosuppressants in blood samples. Relatively good linearities were obtained, which spanned the reference ranges of effective therapeutic concentrations of each immunosuppressant. Intra-day and inter-day accuracy and precision of analytical method were also assessed. This work showed that a compact LC-MS instrument could be used in clinical diagnosis, either to replace conventional lab-scale instruments or to be used in POCT applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号