首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fiber optic aided spectrophotometric technique has been developed for the determination of free acidity in nuclear fuel reprocessing streams. In this method, nitric acid forms yellow colour complex with chrome azurol s. The system obeys Lambert–Beer’s law at 542 nm in the range of acidity 4–14 M. The molar absorption coefficient (ε) and Sandell’s sensitivity (S) of complex are 5.23 × 103 L.mol?1.cm?1 and 1.91 × 10?4 µg/cm2 respectively. Relative standard deviation is less than 1 % and correlation coefficient is 0.999. Results of the present method are in good agreement with those obtained by the standard procedure.  相似文献   

2.
A spectrophotometric method for determination of copper, cobalt, rhodium and iridium ions from nitric acid media after extraction of these ions by 25, 26, 27, 28-tetrahydroxy-5, 11, 17, 23-tetra-[4-(N-hydroxyl-3-phenylprop-2-enimidamido) phenylazo] calix [4] arene (THPAC) has been developed and possible synergistic effect has been investigated. The maximum enhancement was obtained in the presence of 30% 1, 2-dichloroethane in DMF and 3M nitric acid. The trace amounts of the metal were determined spectrophotometrically. Beer’s law was obeyed in concentration range 5.0–10.0 μg, 6.0–120.0 μg, 12.0–100.0 μg, and 10.0–130.0 μg/10 mL of the final solution of copper, cobalt, rhodium and iridium, respectively. The molar absorptivities (l mol?1 cm?1) and Sandell’s sensitivities (μg cm?1) were calculated: Cu (II) = 0.96 × 104, 0.0066; Co (II) = 1.13 × 104, 0.0052; Rh (III) = 0.98 × 104, 0.012; and Ir (III) = 2.03 × 104, 0.0095, respectively. Seven replicate analyses containing of 20.0 μg of Cu (II), 24.0 μg of Co (II), 36.0 μg of Rh (III) and 25.0 μg of Ir (III) gave mean absorbance 0.302, 0.462, 0.344, 0.264; and relative standard deviation 0.65, 0.85, 1.10, 1.08%, respectively. The interference of various ions was studied and optimum conditions were developed for determination of metals in certain alloys, environmental, pharmaceutical and synthetic samples.  相似文献   

3.
A spectrophotometric method for the determination of palladium, iron and tellurium from nitric acid media after extraction of their p-[4-(3,5-dimethylisoxazolyl)azophenylazo]calix(4)arene [DMIAPAC] complexes has been developed and possible synergistic effects have been investigated. Chloroform, carbon tetrachloride, cyclohexane, 1,2-dichloroethane, toluene and xylene were used as the diluents. The maximum enhancement was obtained in the presence of 30% 1,2-dichloroethane. The trace amounts of metals were determined spectrophotometrically. Beer’s law obeyed in the concentration range of 5.0–95.0 μg, 8.0–120.0 μg and 10.0–140.0 μg/10 mL of the final solution of palladium, iron and tellurium, respectively. The molar absorptivities (l mol?1cm?1) and Sandell’s sensitivities (μg cm ?1) were calculated: Pd(II) = 1.73 × 104 and 0.0061; Fe(III) = 1.08 × 104 and 0.0052; Te(IV) = 1.67 × 104 and 0.0077. Ten replicate analyses containing 20 μg of Pd(II), 12.5 μg of Fe(III) and 32 μg of Te(IV) gave mean absorbance of 0.326, 0.242 and 0.418 with relative standard deviation of 0.36, 0.65 and 0.82% for Pd(II), Fe(III) and Te(IV), respectively. The interference of various ions was studied and optimum conditions were developed for the determination of these metals in certain alloys and synthetic mixtures.  相似文献   

4.
A selective extraction–spectrophotometric method has been developed for determination of selenium(IV) using O-methoxyphenyl thiourea (OMePT) as a chelating agent. The basis of the proposed method is the spectrophotometric determination of selenium(IV)–OMePT complex obtained after extraction of selenium(IV) from 3.5 M hydrochloric acid media using OMePT in chloroform solvent. The complex shows maximum absorbance at 350 nm against the reagent blank. The Beer’s law was obeyed over the concentration range 5–60 µg mL?1 of selenium(IV). The optimum concentration range was 20–50 µg mL?1 as evaluated from Ringbom’s plot. The molar absorptivity and Sandell’s sensitivity of the selenium(IV)–OMePT complex in chloroform were 3.312 × 102 L mol?1cm?1 and 0.2384 µg cm?2, respectively. The composition of selenium(IV)–OMePT complex was 1:2 established from slope ratio method, mole ratio method and Job’s continuous variation method. The complex was stable for more than 72 h. The interfering effect of various foreign ions was studied and suitable masking agents were used wherever necessary to enhance the selectivity of the developed method. The proposed method was successfully applied for the determination of selenium(IV) from real samples, viz. pharmaceutical formulations, shampoo, vegetable sample, synthetic mixtures and environmental samples. Repetition of the method was checked by finding the relative standard deviation (RSD) for 10 determinations which was 0.35%.  相似文献   

5.
A fast and effective preconcentration method for extraction of organochlorine pesticides (OCPs) was developed using a homogeneous liquid–liquid extraction based on phase separation phenomenon in a ternary solvent (water/methanol/chloroform) system. The phase separation phenomenon occurred by salt addition. After centrifugation, the extraction solvent was sedimented in the bottom of the conical test tube. The OCPs were transferred into the sedimented phase during the phase separation step. The extracted OCPs were determined using gas chromatography–electron capture detector. Several factors influencing the extraction efficiency were investigated and optimized. Optimal results were obtained at the following conditions: volume of the consolute solvent (methanol), 1.0 mL; volume of the extraction solvent (chloroform), 55 μL; volume of the sample, 5 mL; and concentration of NaCl, 5 % (w/v). Under optimal conditions, the preconcentration factors in the range of 486–1,090, the dynamic linear range of 0.01–100 μg L?1, and the limits of detection of 0.001–0.03 μg L?1 were obtained for the OCPs. Using internal standard, the relative standard deviations for 1 μg L?1 of the OCPs in the water samples were obtained in the range of 4.9–8.6 % (n = 5). Finally, the proposed method was successfully applied for extraction and determination of the OCPs in water and fruit samples.  相似文献   

6.
《Analytical letters》2012,45(12):1868-1881
Abstract

A rapid, simple, and sensitive method was developed for the determination of three imidazole derivatives based on their quenching effect on bis(2,4,6-tricholorophenyl) oxalate (TCPO)–H2O2 chemiluminescence (CL) in the presence of rhodamine 6 G. Conditions affecting CL intensity were studied. With sodium dodecyl sulfate (SDS) as the additional agent, the relative standard deviation (RSD) was more twice the RSD without SDS. Under optimal conditions, good linear ranges were obtained from 1.0 × 10?4 g/mL to 1.0 × 10?6 g/mL, 1.0 × 10?5 g/mL to 1.0 × 10?7 g/mL, and 1.0 × 10?5 g/mL to 7.0 × 10?7 g/mL, with detection limits of 8.0 × 10?7 g/mL, 7.0 × 10?8 g/mL, and 8.0 × 10?8 g/mL (S/N = 3) for hydrobenzole hydrochloride, thiamazole, and mizolastine, respectively. The RSDs for 13 consecutive injections of 1.0 × 10?6 g/mL hydrobenzole hydrochloride, thiamazole, and mizolastine were 1.89%, 1.47%, and 1.69%, respectively, and satisfied results were obtained with the method applied to their pharmaceutical preparations. The possible CL mechanism was simply discussed.  相似文献   

7.
《Analytical letters》2012,45(5):779-788
Abstract

A simple, fast, accurate, and sensitive spectrophotometric method was developed to determine zinc(II). This method is based on the reaction of Zn(II) with di‐2‐pyridyl ketone benzoylhydrazone (DPKBH), at pH=5.5 and 50% (v/v) ethanol. Bee?s law was obeyed in the range 0.020–1.82 µg mL?1 with a molar apsorptivity of 3.64×104 L mol?1 cm?1, and a detection limit (3δ) of 2.29 µg L?1. The action of some interfering ions was verified and the developed method applied to pharmaceutical and biological samples. The results were then compared with those obtained by using a flame atomic absorption technique.  相似文献   

8.
A simple and sensitive spectrophotometric method is developed for the determination of zinc in aqueous solutions. The metal ion forms a greenish-yellow colored complex with 2,4-dihydroxybenzaldehyde isonicotinoyl hydrazone (2,4-DHBINH) in the pH range of 4–10. The complex shows maximum absorbance at 390 nm and in the pH range of 6–8. Beer's law is obeyed in the range 0.10–1.50 μg/mL of Zn(II). The molar absorptivity and Sandell's sensitivity are 3.55 × 104 mol−1 cm−1 and 0.0016 μg/cm2, respectively. The composition of the complex is 1 : 1. The effect of interfering ions has been studied, and the method was applied to the determination of zinc(II) in potable water and pharmaceutical samples. A fast derivative spectrophotometry method is also proposed for the determination of zinc in the range 0.06–1.60 μg/mL, which is more sensitive than the zero order method. __________ Translated from Zhurnal Analiticheskoi Khimii, Vol. 60, No. 9, 2005, pp. 933–937. Original Russian Text Copyright ? 2005 by Sivaramaiah, Raveendra Reddy. The text was submitted by the authors in English.  相似文献   

9.
A new HPLC-DAD method was developed and validated for simultaneous determination of six main phenylethanoid glycosides (calceolarioside D, neocalceolarioside D, verbascoside, isoverbascoside, leucoseptoside A and martynoside) in the aerial parts of four Scutellaria L. taxa from flora of Turkey. All standard compounds showed a good linearity (R 2 > 0.999) in a relatively wide concentration range (1–120 μg/mL). The LOD of the compounds was in the range of 0.104–1.295 μg/mL and the LOQ was in the range of 0.450–2.536 μg/mL. The recoveries of the selected compounds were calculated in the range of 97.46–117.85%. The amounts of the phenylethanoid glycosides showed variation in the extracts. The developed method was found to be accurate, precise and reproducible, and successfully applied to identify and quantify the phenylethanoid glycoside composition of Scutellaria species.  相似文献   

10.
《Analytical letters》2012,45(11):1678-1692
Abstract

A highly selective, sensitive, and rapid method has been developed for the spectrophotometric determination of ruthenium with 5-chloro-2-hydroxythiobenzhydrazide after extraction into molten naphthalene. Ruthenium was determined in the range 1.2–4.5 ppm. The complex was stable for more than 12 h with molar absorptivity of 1.516 × 104 L mol?1 cm?1 and detection limit of 0.0066 ppm. The method was found to be selective for ruthenium in the presence of a large number of diverse ions. Ruthenium was determined in various synthetic mixtures. The method permits the sequential separation and determination of ruthenium, osmium, and platinum from their mixtures.  相似文献   

11.
The application of the recently introduced dispersive liquid–liquid microextraction (DLLME) for the separation and determination of an inorganic selenite [Se(IV)] derivative by means of a gas chromatography–electron-capture detection system has been studied. The selenium derivative was extracted with the DLLME technique using a mixture of ethanol (disperser solvent) and chlorobenzene (extraction solvent). The influences of the various analytical parameters on the derivatization reaction and microextraction procedure have been evaluated and optimized. Under the optimum conditions, an enrichment factor of 122 was obtained for only 5.00 mL of the water sample. The calibration graph was linear in the range of 0.015–10 μg L?1 with a detection limit of 0.005 μg L?1. The relative standard deviation for ten replicate measurements of 2 μg L?1 of selenium was 4.1%. The method was applied to the determination of selenium in environmental surface water samples with satisfactory recovery.  相似文献   

12.
The electrooxidation of dextromethorphan on a composite constructed with carbon nanotube–ionic liquid–carbon microparticles was investigated by cyclic voltammetry in a 100 mM phosphate buffer solution, pH 7.40. In the voltammograms, an irreversible diffusion-controlled anodic peak appeared. The diffusion coefficient of dextromethorphan, the electron-transfer coefficient, and the standard rate constant of the electrooxidation process were found to be 3.45?×?10?6 cm2 s?1, 0.65, and 1.67?×?10?3 cm s?1, respectively. A sensitive and timesaving determination procedure was developed for the analysis of dextromethorphan, and the corresponding analytical parameters were reported. Using this method, dextromethorphan was determined with an LOD and LOQ of 8.81 and 29.36 μM in a linear range of 2.5?×?10?4 to 3.3?×?10?3 M, respectively. The proposed amperometric method was successfully applied to the analysis of commercial pharmaceutical products (syrup and oral drop), and the results were in good agreement with the declared values.  相似文献   

13.
《Analytical letters》2012,45(4):823-833
Abstract

A simple, sensitive, and specific spectrophotometric method for the measurement of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. The azo dye, 4‐(1‐methyl‐1‐mesitylcylobutane‐3‐yl)‐2‐(p‐N,N‐dimethylazobenzene)‐1,3‐thiazole was synthesized with the reaction of 4‐(1‐methyl‐1‐mesitylcylobutane‐3‐yl)‐2‐aminothiazole and N,N‐dimethyl aniline in acidic medium. Obtained azo dye has been characterized by infrared (IR), 1H nuclear magnetic resonance (NMR), and microanalysis methods. The dye shows an absorption maximum at 482 nm. The method is optimized for acid concentration, pH, amount of reagents required, time, and interfering species. All the determinations were carried out at this wavelength throughout the work. At an analytical wavelength of 482 nm, Beer's law is obeyed over the concentration range 0.05 to 2.00 µg nitrite per mL analyte. The molar absorptivity, Sandell's sensitivity, and relative standard deviation are 2.03×104 L mol?1 cm?1±251.3 (95%), 2.28×10?3 µg cm?2, and 2.74% (n=10), respectively. The detection limit of the method is 0.012 µg ml?1 of nitrite ion. The method was succesfully applied to the determination of nitrite in tap water and lake water.  相似文献   

14.
A solid-phase extraction coupled with dispersive liquid–liquid microextraction (DLLME) method followed by graphite furnace atomic absorption spectrometry (GFAAS) was developed for the extraction, preconcentration, and determination of ultra trace amounts of lead in water samples. Variables affecting the performance of both steps were thoroughly investigated. Under optimized conditions, 100 mL of lead solution were first concentrated using a solid phase sorbent. The extracts were collected in 1.50 mL of THF and 18 μL of carbon tetrachloride was dissolved in the collecting solvent. Then 5.0 mL pure water was injected rapidly into the mixture of THF and carbon tetrachloride for DLLME, followed by GFAAS determination of lead. The analytical figures of merit of method developed were determined. With an enrichment factor of 1,800, a linear calibration of 3–60 ng L?1 and a limit of detection of 1.0 ng L?1 were obtained. The relative standard deviation for seven replicate measurements of 30 ng L?1 of lead was 5.2 %. The relative recoveries of lead in mineral, tap, well, and river water samples at spiking level of 10 and 20 ng L?1 are in the range 94–106 %.  相似文献   

15.
A simple sensitive extractive spectrophotometric method for determination of trichloroethylene is proposed. Trichloroethylene is treated with pyridine to form glutaconic aldehyde by heterolytic cleavage of the pyridine ring. Glutaconic aldehyde is further coupled with 4-aminoacetanilide to form an orange–red dye which is extractable in 3-methyl-1-butanol. The extracted dye shows absorption maximum at 520 nm. The system obeys Beer’s law in the range of 0.05–0.8 μg mL?1. Important analytical parameters such as time, temperature, reagent concentration, acidity etc. have been optimized for complete colour reaction. Sandell’s sensitivity and molar absorptivity for the system were found to be 0.001 μg cm?2 and 1.2 × 105 L mol?1 cm?1, respectively. The proposed method is satisfactorily applied to micro-level determination of trichloroethylene in various environmental and biological samples.  相似文献   

16.
This study reports on the development of a fast and efficient method based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography–tandem mass spectrometry (GC–MS/MS) for simultaneous analysis of 128 volatile or semi-volatile pesticide residues belonging to nine classes of pesticides. The important factors related to HS-SPME performance were optimized; these factors include fiber types, water volume, ion strength, extraction temperature, and extraction time. The best extraction conditions include a PDMS/DVB fiber, and analytes were extracted at 90 °C for 60 min from 1 g of tea added to 5 mL of 0.2 g mL?1 NaCl solution. The methodology was validated using tea samples spiked with pesticides at three concentration levels (10, 50, and 100 μg kg?1). In green tea, oolong tea, black tea, and puer tea, 82.8, 88.3, 79.7, and 84.3% of the targeted pesticides meet recoveries ranging from 70 to 120% with a relative standard deviation of?≤?20%, respectively, when spiked at a level of 10 μg kg?1. Limits of quantification in this method for most of the pesticides were 1 or 5 μg kg?1, which are far below their maximum residue limits prescribed by EU. The optimized method was employed to analyze 30 commercial samples obtained from local markets; 17 pesticide residues were detected at concentrations of 2–452 μg kg?1. Chlorpyrifos was the most detected pesticide in 80% of the samples, and the highest concentration of dicofol (452 μg kg?1) was found in a puer tea. This is the first time to find that the optimized extraction temperature for pesticide residues is 90 °C, which is much higher than other reported HS-SPME extraction conditions in tea samples. This developed method could be used to screen over one hundred volatile or semi-volatile pesticide residues which belong to multiple classes in tea samples, and it is an accurate and reliable technique.  相似文献   

17.
A rapid and simple method to determine methylmercury in natural crude medicine of animal origin was developed using gas chromatography electron capture detection (GC-ECD). Methylmercury, one of the forms of organomercury in nature, is much more toxic than inorganic and elemental mercury due to its lipid soluble property. The method is based on acidic digestion in hydrochloric acid solution following the extraction with toluene. The following parameters for the determination of methylmercury with GC-ECD were established: limit of detection 2 μg kg?1, limit of quantification 8 μg kg?1, linearity 10–300 ng mL?1, reproducibility as relative standard deviations 11.8%, 10.7% and 1.7% for 300, 150, and 20 ppb solutions, respectively, and recovery 87.1–112.4%. The results on animal-origin natural medicines using the method developed in this study were assured by comparison with those obtained by the method derived for measuring methylmercury in fish.  相似文献   

18.
A sensitive and simple method based on two-phase liquid-phase microextraction in porous hollow fiber followed by gas chromatography-flame ionization detection was developed for quantification and pharmacokinetic study of valproic acid (VPA, an antiepileptic drug) in rat plasma after oral administration of pure sodium valproate (25 mg kg?1). Some parameters such as type of organic solvent, pH of sample solution, stirring speed, salt addition, extraction time, and volume of sample that affected extraction efficiency of VPA were optimized. Under optimized microextraction conditions, VPA was extracted with 10 μL 1-octanol from 0.5 mL rat plasma previously diluted with 4.5 mL acidified and salinated water (pH 2) using 1-octanoic acid as internal standard. The limit of detection was 17 ng mL?1 with linear response over the concentration range of 50–10,000 ng mL?1 with correlation coefficient higher than 0.998. The developed method was successfully applied to determination of pharmacokinetic parameters such as t max (peak time in concentration–time profile), C max (peak concentration in concentration–time profile), t 1/2 (elimination half-life), AUC0–t (area under the curve for concentration versus time), clearance, and apparent distribution volume in rats following oral administration of VPA.  相似文献   

19.
Graphene, a novel class of carbon nanostructures, has great promise for use as sorbent materials because of its ultrahigh specific surface area. A new method using reduced graphene oxide (RGO) as sorbent was developed for the preconcentration of trace amounts of zinc (Zn) to its determination by flame atomic absorption spectrometry. Zinc could be adsorbed quantitatively on RGO in the pH range of 1–9, and then eluted completely with 0.5 mL of 0.1 mol L?1 HCl. Some effective parameters on the extraction were selected and optimized. Under optimum conditions, the calibration graph was linear in the concentration range of 0.2–15 μg L?1 with a detection limit of 0.14 μg L?1 with an enrichment factor of 100.12. The relative standard deviation for ten replicate measurements of 10 μg L?1 of Zn was 0.58 %, respectively. The proposed method was successfully applied in the analysis of rock and vegetable samples. Good spiked recoveries over the range of 99.9–100 % were obtained. This work not only proposes a useful method for sample preconcentration, but also reveals the great potential of graphene as an excellent sorbent material in analytical processes.  相似文献   

20.
A sensitive and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method has been developed and validated for the quantification of huperzine A in human plasma. After the addition of trimetazidine, the internal standard (IS) and sodium hydroxide, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on an Agilent Zorbax SB C18 column (100 mm × 2.1 mm ID, dp 3.5 μm) using an elution system of 10 mM ammonium acetate solution–methanol–formic acid (18:82:0.1, v/v) as the mobile phase. The quantification of target compounds was obtained by using multiple reaction monitoring (MRM) transitions: m/z 243.1, 210.1 and 267.2, 166.0 were measured in positive mode for huperzine A and IS. Linearity was established for the range of concentrations 0.01–4.0 ng mL?1 with a coefficient of correlation (r) of 0.9991. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.01 ng mL?1. The method has been successfully applied to study the pharmacokinetics of huperzine A in healthy male Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号