首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 699 毫秒
1.
Cui H  Dutta P  Ivory CF 《Electrophoresis》2007,28(7):1138-1145
This paper reports both the experimental application and 2-D simulation of ITP of proteins in a networked microfluidic chip. Experiments demonstrate that a mixture of three fluorescent proteins can be concentrated and stacked into adjacent zones of pure protein under a constant voltage of 100 V over a 2 cm long microchannel. Measurements of the isotachophoretic velocity of the moving zones demonstrates that, during ITP under a constant voltage, the zone velocity decreases as more of the channel is occupied by the terminating electrolyte. A 2-D ITP model based on the Nernst-Planck equations illustrates the stacking and separation features of ITP using simulations of three virtual proteins. The self-sharpening behavior of ITP zones dispersed by a T-junction is clearly demonstrated both by experiment and by simulation. Comparison of 2-D simulations of ITP and zone electrophoresis (ZE) confirms that ZE lacks the ability to resharpen protein zones after they pass through a T-junction.  相似文献   

2.
A new mimetic enzyme immunoassay (MEIA) method for α-1-fetoprotein (AFP) was developed using a mimetic enzyme Mn(III)-tetra(sulfophenyl)porphine (Mn-TPPS4) as a labelling reagent to catalyze the fluorescence reaction of 4-hydroxy-phenylacetic acid (HPA) and hydrogen peroxide. In the sandwich assay standard AFP solution or AFP containing umbilical blood serum first reacts with antibody (anti-AFP)coated on a 40-well plate (polystyrene), and then further reacts with Mn-TPPS4-labelled anti-AFP; the Mn-TPPS4 on the bound fraction, after removing the free fraction was determined by measuring the fluorescence intensity as a result of the reaction between HPA and H2O2, catalyzed by bound Mn-TPPS4 and anti-AFP conjugate, which was proportional to the concentration of AFP. AFP in the range 0.01–10 μg per well can be determined with a detection limit of 1 ng per well. The method has sufficient sensitivity to be applied to the determination of AFP in umbilical blood serum.  相似文献   

3.
Caifeng Ding  Fei Zhao  Jin-Ming Lin 《Talanta》2009,78(3):1148-4751
A novel and effective electrochemical immunosensor for the rapid determination of α-fetoprotein (AFP) based on carbon paste electrode (CPE) consisting of room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) and graphite. The surface of the CPE was modified with gold nanoparticles for the immobilization of the α-fetoprotein antibody (anti-AFP). By sandwiching the antigen between anti-AFP on the CPE modified with gold nanoparticles and the secondary antibody, polyclonal anti-human-AFP labeled with horseradish peroxidase (HRP-labeled anti-AFP), the immunoassay was established. The concentration of AFP was determined based on differential pulse voltammetry (DPV) signal, which was generated in the reaction between O-aminophenol (OAP) and H2O2 catalyzed by HRP labeled on the sandwich immunosensor. AFP concentration could be measured in a linear range of 0.50-80.00 ng mL−1 with a detection limit of 0.25 ng mL−1. The immunosensor exhibited high sensitivity and good stability, and would be valuable for clinical assay of AFP.  相似文献   

4.
A rapid microfluidic based capillary electrophoresis immunoassay (CEIA) was developed for on-line monitoring of glucagon secretion from pancreatic islets of Langerhans. In the device, a cell chamber containing living islets was perfused with buffers containing either high or low glucose concentration. Perfusate was continuously sampled by electroosmosis through a separate channel on the chip. The perfusate was mixed on-line with fluorescein isothiocyanate-labeled glucagon (FITC-glucagon) and monoclonal anti-glucagon antibody. To minimize sample dilution, the on-chip mixing ratio of sampled perfusate to reagents was maximized by allowing reagents to only be added by diffusion. Every 6 s, the reaction mixture was injected onto a 1.5-cm separation channel where free FITC-glucagon and the FITC-glucagon–antibody complex were separated under an electric field of 700 V cm−1. The immunoassay had a detection limit of 1 nM. Groups of islets were quantitatively monitored for changes in glucagon secretion as the glucose concentration was decreased from 15 to 1 mM in the perfusate revealing a pulse of glucagon secretion during a step change. The highly automated system should be enable studies of the regulation of glucagon and its potential role in diabetes and obesity. The method also further demonstrates the potential of rapid CEIA on microfluidic systems for monitoring cellular function.  相似文献   

5.
Liu Q  Han M  Bao J  Jiang X  Dai Z 《The Analyst》2011,136(24):5197-5203
A sensitive and specific immunoassay method for detecting α-fetoprotein (AFP) based on electrogenerated chemiluminescence (ECL) was described. ECL could perform detection for a series of different concentrations of AFP. CdSe quantum dots (QDs) were used as labels and were linked to AFP antibody (anti-AFP, the secondary antibody, Ab2*). Immunoassay was carried out on a modified electrode using a sandwich assay approach, where anti-AFP (Ab1) was covalently bound to the surface of an Au electrode to be allowed to capture AFP specifically. Afterwards, Ab2* was allowed to bind selectively to the captured AFP. The non-specific adsorption was negligible. In the presence of H(2)O(2), the ECL intensity increased with the increase of AFP, which indicated that an immunosensor for AFP was constructed. The detection of AFP based on measuring the ECL intensity of CdSe without the enzyme and mediator can promote the stability of the immunosensor. The linear range of the AFP assay was from 0.002 to 32 ng mL(-1). Furthermore, the immunosensor showed high sensitivity, good precision, stability, and reproducibility and could be used for the detection of real samples with consistent results in comparison with those obtained by the enzyme-linked immunosorbent assay (ELISA) method. The strategy was successfully demonstrated as a simple, cost-effective, specific, and potential method to detect AFP in practical samples.  相似文献   

6.
We present a new rapid and easy-to-use immunoassay chip which we have named the immuno-pillar chip. It has hydrogel pillars, fabricated inside a microchannel, with many antibody molecules immobilized onto 1 μm diameter polystyrene beads. To evaluate the chip performance, we applied it to the sandwich assay of C-reactive protein (CRP), α-fetoprotein (AFP) and prostate-specific antigen (PSA), a cardiac and inflammation marker, tumors and prostate cancer markers, respectively. For detection of disease markers, we confirmed the chip provides rapid analysis (total assay time of about 4 min) with high sensitivity, it is easy-to-use (no special skills are needed), and it uses small volumes of the sample and reagent (0.25 μL each). Moreover, multiplex assay for three biomarkers was also possible. Additionally, the immuno-pillar chip has a big advantage of having hardly any influence on the assay results even if the introduction quantities of the sample or reagents are different.  相似文献   

7.
A new fluorimetric immunoassay for alpha-fetoprotein (AFP) has been developed using a novel promising mimetic peroxidase, iron(III) tetrasulfonatophthalocyanine (FeTSPc), as a labeling reagent to catalyze the fluorescence reaction of P- hydroxyphenylacetic acid (P-HPA) and hydrogen peroxide (H2O2). In the competitive immunoassay, anti-AFP antibody was coated on a 96-well plate (polystyrene) and a constant amount of FeTSPc-labeled AFP and a known amount of test solution were added. Non-labeled and FeTSPc-labeled AFP compete for binding to the plate-bound antibody. After the immunoreaction, the immunochemically adsorbed FeTSPc-AFP conjugate moiety was determined by measuring the fluorescence produced in a solution containing P-HPA and H2O2. AFP can be determined in the concentration range of 1-300 ng mL(-1) with a detection limit of 0.5 ng mL(-1).  相似文献   

8.
This feasibility study deals with column switching in zone electrophoresis (ZE) separations on a column coupling (CC) chip. The column switching implemented into the ZE separations an on-chip sample clean up applicable for both the multicomponent and high salinity samples. In addition, complemented by different separation mechanisms in the coupled columns (channels), it provided benefits of two-dimensional separations. Properly timed column switching gave column-to-column transfers of the analytes, characterized by 99-102% recoveries, delivered to the second separation stage on the chip the analyte containing fractions contaminated only with minimum amounts of the matrix constituents. A diffusion driven transport of the matrix constituents to the second channel of the chip (due to direct contacts of the electrolyte solutions in the bifurcation region), representing 0.1-0.2% of the loaded sample constituents, was found to accompany the sample clean up performed on the CC chip. This source of potential disturbances to the separation in the second channel, however, is not detectable in a majority of practical situations. With respect to a 900 nl volume of the sample channel on the CC chip, the electric field and isotachophoresis (ITP) stackings were employed to minimize the injection dispersion in the separations and concentrate the analytes. Here, the column switching, removing a major part of the stacker from the separation system, provided a tool effective in a control of the destacking of analytes. Highly reproducible ZE separations as attained in this work also for the chip-to-chip and equipment-to-equipment frames can be ascribed, at least in part, to suppressions of electroosmotic and hydrodynamic flows of the solutions in which the separations were performed.  相似文献   

9.
A novel mimetic enzyme immunoassay to determine α-1-fetoprotein (AFP) in solution was developed. Hemin, a horseradish peroxidase substitute, was used as a labelling reagent to catalyze the reaction of p-hydroxyphenylacetic (HPA) and hydrogen peroxide in alkaline media. In the competitive immunoassay, monoclonal anti-AFP antibody was coated on a 96-well plate (polystyrene) and a constant amount of hemin-labelled AFP and a known volume of test solution were added. Non-labelled and hemin-labelled AFP compete for binding to the plate-bound antibody. After the immunoreaction, the immunochemically adsorbed hemin-AFP conjugate moiety was determined by measuring the fluorescence produced in a solution containing HPA and hydrogen peroxide. The calibration graph for AFP was linear over the range 0 ~ 380 ng/ well with a detection limit of 1.0 ng/well. The method has been applied to determine the AFP in human blood serum with satisfactory results.  相似文献   

10.
Sample pre-concentration by isotachophoresis in microfluidic devices   总被引:1,自引:0,他引:1  
We have designed microfluidic devices with the aim of coupling isotachophoresis (ITP) with zone electrophoresis (ZE) as a method to increase the concentration limit of detection in microfluidic devices. We used plastic multi-channel chips, designed with long sample injection channel segments, to increase the sample loading. The chip was designed to allow stacking of the sample into a narrow band by discontinuous ITP buffers and subsequent separation in the ZE mode. In the ITP-ZE mode, with a 2-cm long sample injection plug, sensitivity was increased by 400-fold over chip ZE and we found that the separation performance after the ITP stacking was comparable to that of regular chip ZE. We report sub-picomolar limits of detection of fluorescently labeled ACLARA eTag reporter molecules electrokinetically injected from cell lysate sample matrixes containing moderate salt concentrations. We evaluated sample injections from buffers with varied ionic strengths and found that efficient stacking and separations were obtained in both low and high conductivity buffers, including physiological buffer with at least 140 mM salt. We applied ITP-ZE to the analysis of a cell surface protease (ADAM 17) which used live intact cells in physiological buffers with detection limits below 10 cells/assay.  相似文献   

11.
利用芯片电泳方法考察瞬间等速电泳-筛分电泳偶联分析的结果,比较了自由溶液和筛分介质中DNA瞬间等速电泳的预浓缩效果.结果显示,相比较于筛分介质条件,自由溶液瞬间等速电泳有利于改善预浓缩和后续筛分电泳分离效果.对此结果的解释是:自由溶液条件下DNA迁移速度的提高可以延长瞬间等速电泳持续时间,有利于提高预浓缩效率.此外,样品压缩区带在自由溶液-筛分介质界面的二次富集也是预浓缩效果得到改善的原因之一.  相似文献   

12.
The use of capillary zone electrophoresis (CZE) on-line coupled with isotachophoresis (ITP) sample pretreatment (ITP-CZE) on a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to the determination of bromate in drinking water was investigated. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the ITP-CZE separations. A high sample load capacity, linked with the use of ITP in this combination, made possible loading of the samples by a 9.2 microL sample injection channel of the chip. In addition, bromate was concentrated by a factor of 10(3) or more in the ITP stage of the separation and, therefore, its transfer to the CZE stage characterized negligible injection dispersion. This, along with a favorable electric conductivity of the carrier electrolyte solution, contributed to a 20 nmol/L (2.5 ppb) limit of detection for bromate in the CZE stage. Sample cleanup, integrated into the ITP stage, effectively complemented such a detection sensitivity and bromate could be quantified in drinking water matrices when its concentration was 80 nmol/L (10 ppb) or slightly less while the concentrations of anionic macroconstituent (chloride, sulfate, nitrate) in the loaded sample corresponding to a 2 mmol/L (70 ppm) concentration of chloride were still tolerable. The samples containing macroconstituents at higher concentrations required appropriate dilutions and, consequently, bromate in these samples could be directly determined only at proportionally higher concentrations.  相似文献   

13.
Hirokawa T  Takayama Y  Arai A  Xu Z 《Electrophoresis》2008,29(9):1829-1835
Aiming to achieve high-performance analysis of DNA fragments using microchip electrophoresis, we developed a novel sample injection method, which was given the name of floating electrokinetic supercharging (FEKS). In the method, electrokinetic injection (EKI) and ITP preconcentration of samples was performed in a separation channel, connecting two reservoir ports (P3 and P4) on a cross-geometry microchip. At these two stages, side channels, crossing the separation channel, and their ports (P1 and P2) were electrically floated. After the ITP-stacked zones passed the cross-part, they were eluted for detection by using leading ions from P1 and P2 that enabled electrophoresis mode changing rapidly from ITP to zone electrophoresis (ZE). Possible sample leakage at the cross-part toward P1 and P2 was studied in detail on the basis of computer simulation using a CFD-ACE+ software and real experiments, through which it was validated that the analyte recovery to the separation channel was almost complete. The FEKS method successfully contributed to higher resolution and shorter analysis time of DNA fragments on the cross-microchip owing to more rapid switching from ITP status to ZE separation in comparison with our previous EKS procedure realized on a single-channel microchip. Without any degradation of resolution, the achieved LODs were on average ten times better than using conventional pinched injection.  相似文献   

14.
Huang H  Xu F  Dai Z  Lin B 《Electrophoresis》2005,26(11):2254-2260
A microchip for integrated isotachophoretic (ITP) preconcentration with gel electrophoretic (GE) separation to decrease the detectable concentration of sodium dodecyl sulfate (SDS)-proteins was developed. Each channel of the chip was designed with a long sample injection channel to increase the sample loading and allow stacking the sample into a narrow zone using discontinuous ITP buffers. The pre-concentrated sample was separated in GE mode in sieving polymer solutions. All the analysis steps including injection, preconcentration, and separation of the ITP-GE process were performed continuously, controlled by a high-voltage power source with sequential voltage switching between the analysis steps. Without deteriorating the peak resolution, four SDS-protein analyses with integrated ITP-GE system resulted in a decreased detectable concentration of approximately 40-fold compared to the GE mode only. A good calibration curve for molecular weights of SDS-proteins indicated that the integrated ITP-GE system can be used for qualitative analysis of unknown protein samples.  相似文献   

15.
A feasibility study was performed using zone electrophoresis (ZE) coupled on‐line with isotachophoresis (ITP) sample pretreatment on a poly(methyl methacrylate) column‐coupling chip with integrated conductivity detection for direct determination of drugs in serum. Valproic acid (an antiepileptic drug), having a therapeutic range of 0.35–0.69 mmol/L (50–100 mg/L), was a test analyte while reference serum samples served as proteinaceous matrices. ITP provided in the ITP‐ZE combination a multitask sample pretreatment: (1) separation of the analyte from the serum matrix and its concentration into a narrow ITP band, (2) removal of the matrix constituents migrating in the ITP stack from the separation compartment of the chip, (3) ITP stacking of the drug released on a continuous electrophoretic decomposition of the drug‐protein complex. A high sample loadability, closely linked with the use of ITP in the first separation stage, made it possible to inject diluted serum samples with the aid of a 0.95 μL sample channel of the chip. Consequently, a 1–2 μmol/L concentration limit of quantitation for valproate from the response of the conductivity detector in the ZE stage of the combination was reached. The drug could be reliably determined in less than 10 minutes also in instances when its concentration in serum was below the lower value of the therapeutic range. 90–94% recoveries of valproate from serum samples were obtained in its direct ITP‐ZE determination when the filtration of the diluted serum (a 0.45 μm pore size filter) was the only pre‐column sample handling operation. No disturbances attributable to the precipitation of proteins from the loaded samples in the chip channels were detected.  相似文献   

16.
A bead-bed immunoassay system suitable for simultaneous assay of multiple samples was constructed on a microchip. The chip had branching multichannels and four reaction and detection regions; the constructed system could process four samples at a time with only one pump unit. Interferon gamma was assayed by a 3-step sandwich immunoassay with the system coupled to a thermal lens microscope as a detector. The biases of the signal intensities obtained from each channel were within 10%, and coefficients of variation were almost the same level as the single straight channel assay. The assay time for four samples was 50 min instead of 35 min for one sample in the single-channel assay; hence higher throughput was realized with the branching structure chip.  相似文献   

17.
A new fluorimetric immunoassay for α-fetoprotein (AFP) has been developed using a novel promising mimetic peroxidase, iron(III) tetrasulfonatophthalocyanine (FeTSPc), as a labeling reagent to catalyze the fluorescence reaction of P- hydroxyphenylacetic acid (P-HPA) and hydrogen peroxide (H2O2). In the competitive immunoassay, anti-AFP antibody was coated on a 96-well plate (polystyrene) and a constant amount of FeTSPc-labeled AFP and a known amount of test solution were added. Non-labeled and FeTSPc-labeled AFP compete for binding to the plate-bound antibody. After the immunoreaction, the immunochemically adsorbed FeTSPc–AFP conjugate moiety was determined by measuring the fluorescence produced in a solution containing P-HPA and H2O2. AFP can be determined in the concentration range of 1–300 ng mL–1 with a detection limit of 0.5 ng mL–1. Received: 14 November 2000 / Revised: 29 December 2000 / Accepted: 15 January 2001  相似文献   

18.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

19.
This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.  相似文献   

20.
The precise design and operational control of the separation process of liquid matrices is key to the performance of on-chip liquid analysis. Present research attempts from the engineering point of view to investigate of the process occurring in the microfluidic channels for chip design with the best separation efficiency. An one-dimensional model of electrokinetic sample motion was developed to simulate the separation process of sample containing amino acids (tryptophan, tyrosine, proline, methionine) that migrate in a buffer solution through a straight separation channel made of poly(methyl methacrylate) within a microfluidic chip under different conditions. On the basis of the simulations by the finite-difference method the effects of the channel size, the chip material, the applied voltage difference and the test solution pH on separation rate are discussed. It was found that for the channel length of 2 cm the resolution of peaks is optimal and the fastest time of amino acids separation is 4 s.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号