首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper describes a bioanalytical method involving a simple liquid-liquid extraction for the simultaneous HPLC determination of the enantiomers of tramadol, the active metabolite O-desmethyltramadol (M1), and the other main metabolite N-desmethyltramadol (M2) in biological samples. Chromatography was performed at 5 degrees C on a Chiracel OD-R column containing cellulose tris(3,5-dimethylphenylcarbamate) as chiral selector, preceded by a achiral end-capped C8 column (LiChrospher 60-RP-selected B 5 microm, 250 mm x 4 mm). The mobile phase was a mixture of phosphate buffer containing sodium perchlorate (1 M) adjusted to pH 2.5-acetonitrile-N,N-dimethyloctylamine (74.8:25:0.2). The flow rate was 0.5 ml/min. Fluorescence detection (lambda(ex) 200 nm/lambda(em) 301 nm) was used. Fluconazol was selected as internal standard. The limit of quantitation of each enantiomer of tramadol and their metabolites was 0.5 ng/ml (sample size = 0.5 ml). The chiral conditions and the LC optimisation were investigated in order to select the most appropriate operating conditions. The method developed has also been validated. Mean recoveries above of 95% for each enantiomer were obtained. Calibration curves for tramadol enantiomers (range 1-500 ng/ml), M1 enantiomers (range 0.5-100 ng/ml), and M2 enantiomers (range 0.5-250 ng/ml) were linear with coefficients of correlation better than 0.996. Within-day variation determined on four different concentrations showed acceptable values. The relative standard deviation (R.S.D.) was determined to be less than 10%. This method was successfully used to investigate plasma concentration of enantiomers of tramadol, O-desmethyltramadol and N-desmethyltramadol in a pharmacokinetic study.  相似文献   

2.
Simultaneous HPLC determination of the analgetic agent tramadol, its major pharmacodynamically active metabolite (O-desmethyltramadol) in human plasma is described. Simple methods for the preparation of the standard of the above-mentioned tramadol metabolite and N1,N1-dimethylsulfanilamide (used as the internal standard) are also presented. The analytical procedure involved a simple liquid-liquid extraction of the analytes from the plasma under the conditions described previously. HPLC analysis was performed on a 250x4 mm chromatographic column with LiChrospher 60 RP-selectB 5-microm (Merck) and consists of an analytical period where the mobile phase acetonitrile-0.01 M phosphate buffer, pH 2.8 (3:7, v/v) was used, and of a subsequent wash-out period where the plasmatic ballast compounds were eluted from the column using acetonitrile-ultra-high-quality water (8:2, v/v). The whole analysis, including the equilibration preceding the initial analytical conditions lasted 19 min. Fluorescence detection (lambda(ex) 202 nm/lambda(em) 296 nm for tramadol and its metabolite, lambda(ex) 264 nm/lambda(em) 344 nm for N1,N1-dimethylsulfanilamide) was used. The validated analytical method was applied to pharmacokinetic studies of tramadol in human volunteers.  相似文献   

3.
An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.  相似文献   

4.
A simple, rapid and sensitive method was developed for the simultaneous quantification of chlorogenic acid (CGA) and caffeic acid (CA) in rat plasma using a high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile followed by centrifugation. The analytes and internal standard ferulic acid were separated on an Intersil C8-3 column (5 mm; 250 x 2.1 mm) with acetonitrile/0.05% triethylamine solution (70:30, v/v) as mobile phase at a flow rate of 0.2 mL/min with an operating temperature of 30 degrees C. Detection was performed on a quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operated in selected ion monitoring (SIM) mode. Negative ion ESI was used to form deprotonated molecules at m/z 353 for chlorogenic acid, m/z 179 for caffeic acid, and m/z 193 for the internal standard ferulic acid. Linear detection responses were obtained for CGA concentrations ranging from 0.005 to 2.0 microg/mL and for CA concentrations ranging from 0.010 to 2.0 microg/mL and the lower limits of quantitation (LLOQs) for CGA and CA were 0.005 and 0.01 microg/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.0% for both analytes. Deviation of the assay accuracies was within +/-10.0% for both analytes. Their average recoveries were greater than 88.0%. Both analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic study of CGA and CA following an intravenous dose of 5 mL/kg mailuoning injection to rats.  相似文献   

5.
《Analytical letters》2012,45(4):607-616
A selective, rapid, and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS/MS) method was developed and validated for the quantification of trospium chloride in human plasma. With tramadol chloride as the internal standard, sample pretreatment involved a simple liquid-liquid extraction with chloroform-isopropyl alcohol (40/2, v/v) of 0.5 ml plasma. The analysis was carried out on a Hypsil C18 column (150 mm × 2.1 mm, 5.0 μm) with a flow rate of 0.2 ml/min. The mobile phase was methanol-5% acetic acid-20 mM ammonium methylate (55/30/15, v/v/v). The detection was performed by a selected reaction monitoring (SRM) mode via electrospray ionization (ESI). Linear calibration curves were obtained in the concentration range of 0.2–50.0 ng/ml, with a lower limit of quantification of 0.2 ng/ml. The intra- and inter-day precision (RSD) values were below 15%. The method was successfully applied to a clinical bioequivalence study of trospium chloride in Chinese healthy volunteers following oral administration.  相似文献   

6.
A rapid and sensitive high‐performance LC‐MS/MS method was developed and validated for the simultaneous quantification of codeine and its metabolite morphine in human plasma using donepezil as an internal standard (IS). Following a single liquid‐liquid extraction with ethyl acetate, the analytes were separated using an isocratic mobile phase on a C18 column and analyzed by MS/MS in the selected reaction monitoring mode using the respective [M+H]+ ions, mass‐to‐charge ratio (m/z) 300/165 for codeine, m/z 286/165 for morphine and m/z 380/91 for IS. The method exhibited a linear dynamic range of 0.2–100/0.5–250 ng/mL for codeine/morphine in human plasma, respectively. The lower LOQs were 0.2 and 0.5 ng/mL for codeine and its metabolite morphine using 0.5 mL of human plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated LC‐MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 30 mg codeine phosphate.  相似文献   

7.
The aim of this study was to improve and validate a more stable and less time‐consuming method based on liquid chromatography and tandem mass spectrometry (LC‐ MS/MS) for the quantitative measurement of imatinib and its metabolite N‐ demethyl‐imatinib (NDI) in human plasma. Separation of analytes was performed on a Waters XTerra RP18 column (50 × 2.1 mm i.d., 3.5 μm) with a mobile phase consisting of methanol–acetonitrile–water (65:20:15, v /v/v) with 0.05% formic acid at a flow‐rate of 0.2 mL/min. The Quattro MicroTM triple quadruple mass spectrometer was operated in the multiple‐reaction‐monitoring mode via positive electrospray ionization interface using the transitions m /z 494.0 → 394.0 for imatinib, m /z 479.6 → 394.0 for NDI and m /z 488.2 → 394.0 for IS. The method was linear over 0.01–10 μg/mL for imatinib and NDI. The intra‐ and inter‐day precisions were all <15% in terms of relative standard deviation, and the accuracy was within ±15% in terms of relative error for both imatinib and NDI. The lower limit of quantification was identifiable and reproducible at 10 ng/mL. The method was sensitive, specific and less time‐consuming and it was successfully applied in gastrointestinal stromal tumor patients treated with imatinib.  相似文献   

8.
A simple and sensitive method was developed for the simultaneous quantification of harpagoside and cinnamic acid in rat plasma using high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile. The analytes were separated on an Intersil C8-3 column (2.1 mm i.d.x250 mm, 5 microm) with acetonitrile-5 mm ammonium formate aqueous solution (60:40, v/v) as mobile phase at a flow-rate of 0.2 mL/min. Detection was performed on a quadrupole mass spectrometer equipped with electrospray ionization (ESI) source operated under selected ion monitoring (SIM) mode. [M+HCOO]- at m/z 539 for harpagoside, [M-H]- at m/z 147 for cinnamic acid and [M-H]- at m/z 137 for salylic acid (internal standard) were selected as detecting ions, respectively. The method was validated over the concentration range 7-250 ng/mL for harpagoside and 5-500 ng/mL for cinnamic acid. The lower limits of quantitation for harpagoside and cinnamic acid were 7 and 5 ng/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.5% and the assay accuracies (RE%) ranged from -5.3 to 3.0% for both analytes. Their average recoveries were greater than 86%. Both analytes were proved to be stable during all sample storage, preparation and analysis procedures. The method was successfully applied to the pharmacokinetic study of harpagoside and cinnamic acid following oral administration of Radix Scrophulariae extract to rats.  相似文献   

9.
This method describes the simultaneous separation, identification, quantification and confirmation of betamethasone (BTM) and dexamethasone (DXM) in equine plasma by liquid chromatography (LC) integrated with multidimensional tandem mass spectrometry. Analytes were directly extracted from equine plasma by methyl tert-butyl ether (MTBE). The residues were reconstituted with sample solvent. LC separation of the analytes was performed on a Hypercarb column using acetonitrile/water/formic acid (95:5:0.5, v/v/v) as the mobile phase. Sample screening, quantification and confirmation were performed in multiple reaction monitoring (MRM) mode. The method was linear over the concentration range of 0.1-75 ng/mL for both analytes. Limit of detection (LOD) was 50 pg/mL and that of quantification (LOQ) was 100 pg/mL for both analytes. The limit of confirmation (LOC) for the presence of BTM or DXM by MRM was 0.5 ng/mL. The intra-and inter-day precisions expressed as coefficient of variation (CV) for quantification of DXM and BTM from 0.1 to 50 ng/mL were less than 7% and the accuracy was in the range of 97-105%. This method is capable of distinguishing BTM from DXM when both analytes are simultaneously present in equine plasma. Measurement uncertainty for both analytes was estimated at less than 16%. The method is rapid, specific, selective, sensitive, simple and reliable. The importance of this method is its usefulness in directly identifying and differentiating BTM from DXM without derivatization.  相似文献   

10.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of risperidone (RSP) and its active metabolite 9-hydroxyrisperidone (9-OH-RSP) in human plasma. The analytes were extracted from human plasma by using the protein precipitation extraction technique. Methyl risperidone was used as internal standard for RSP and 9-OH-RSP. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 411.28 --> 191.15 for RSP and m/z 427.30 --> 207.10 for 9-OH-RSP. The method involves a simple extraction, isocratic chromatography conditions and mass spectrometric detection that enable detection at sub-nanogram levels. The proposed method has been validated with a linear range of 0.10-15.0 ng/mL for RSP and 9-OH-RSP. The intrarun and interrun precision and accuracy values were within 15%. The overall recoveries for RSP and 9-OH-RSP were 82.1% and 83.2%, respectively. The total analysis time was as low as 3.0 min only. The developed method was applied for the determination of the pharmacokinetic parameters of RSP and 9-OH-RSP following a single oral administration of a 1 mg RSP tablet in 24 healthy male volunteers.  相似文献   

11.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

12.
A sensitive high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS) method was developed and validated for the simultaneous quantification of trandolapril and its metabolite trandolaprilat in human plasma using ramipril as an internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 429/168 for trandolapril, m/z 401/168 for trandolaprilat and m/z 415/166 for the internal standard. The method exhibited a linear dynamic range of 20-10,000 pg/mL for both trandolapril and trandolaprilat in human plasma. The lower limit of quantification was 20 pg/mL for both trandolapril and its metabolite. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

13.
A rapid, sensitive, and simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method for the determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using sildenafil as an internal standard (IS) was developed and validated. Udenafil, DA-8164 and IS from a 100 microL aliquot of biological samples were extracted by protein precipitation using acetonitrile. Chromatographic separation was carried on an Acquity UPLC BEH C(18) column (50 x 2.1 mm, i.d., 1.7 microm) with an isocratic mobile phase consisting of acetonitrile and containing 0.1% formic acid (75:25, v/v) at flow rate of 0.4 mL/min, and total run time was within 1 min. Detection and quantification was performed by the mass spectrometer using multiple reaction-monitoring mode at m/z 517 --> 283 for udenafil, m/z 406 --> 364 for DA-8164 and m/z 475 --> 100 for IS. The assay was linear over a concentration range of 1-600 ng/mL with a lower limit of quantification of 1 ng/mL in both human plasma and urine. The coefficient of variation of this assay precision was less than 13.7%, and the accuracy exceeded 92.0%. This method was successfully applied for pharmacokinetic study after oral administration of udenafil 100 mg to healthy Korean male volunteers.  相似文献   

14.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

15.
Drug abuse is both an age-old and a constantly evolving problem in society. Trends in illicit drug use are highly fluid, with new formulations increasing in popularity. For this reason, methods for illicit drug detection and analysis need to be continually updated so they remain useful and relevant. A recent trend in street heroin production has seen it diluted with large amounts of tramadol in addition to the classical diluents such as acetaminophen and caffeine. This study describes a sensitive, simple and accurate high-performance liquid chromatographic method with ultraviolet detection for the simultaneous detection of heroin, 6-acetylmorphine, morphine, tramadol and O-desmethyltramadol in the blood of rats using a liquid-liquid back-extraction method. The separation was performed on LichroCART RP-18e with particle size of 5 μm (250 × 4.6 mm) with mobile phase acetonitrile-50 mM KH(2)PO(4) buffer, pH 7.1, using a gradient mode with a 1.0 mL/min flow rate. The calibration curves were linear in the concentration ranges 0.25-100 and 0.1-100 μg/mL for morphine and other analytes, respectively. Recovery values for the substances ranged between 59 and 83%. This technique was successfully used in pharmacokinetic studies measuring 6-acetylmorphine, morphine, tramadol and O-desmethyltramadol in the blood of rats intraperitoneally treated with a blend of 10 mg/kg heroin and 70 mg/kg tramadol. This technique shows promise for analysis of confiscated street heroin.  相似文献   

16.
A rapid tandem mass spectrometric (MS-MS) method for the quantification of Oxcarbazepine (OXB) in human plasma using imipramine as an internal standard (IS) has been developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 3.0 min, using a mobile phase of acetonitrile-10 mM ammonium formate (90 : 10 v/v) at a flow rate of 0.3 ml/min. Quantitation was achieved using multiple reaction monitoring (MRM) scan at MRM transitions m/z 253>208 and m/z 281>86 for OXB and the IS respectively. Calibration curves were linear over the concentration range of 0.2-16 mug/ml (r>0.999) with a limit of quantification of 0.2 mug/ml. Analytical recoveries of OXB from spiked human plasma were in the range of 74.9 to 76.3%. Plackett-Burman design was applied for screening of chromatographic and mass spectrometric factors; factorial design was applied for optimization of essential factors for the robustness study. A linear model was postulated and a 2(3) full factorial design was employed to estimate the model coefficients for intermediate precision. More specifically, experimental design helps the researcher to verify if changes in factor values produce a statistically significant variation of the observed response. The strategy is most effective if statistical design is used in most or all stages of the screening and optimizing process for future method validation of pharmacokinetic and bioequivalence studies.  相似文献   

17.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

18.
A simple, rapid and sensitive liquid chromatography–tandem mass spectroscopy (LC–MS/MS) method was developed and validated for the determination of ethyl gallate, a pharmacologically active constituent isolated from Lagerstroemia speciosa (Linn.) Pers. This method was used to examine the pharmacokinetics of ethyl gallate and its major metabolite gallic acid in rat plasma using propyl gallate as an internal standard. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a Zorbax SB‐C18 column (3.5 μm, 2.1 × 50 mm) with an isocratic mobile phase consisted of methanol–acetonitrile–10 mM ammonium acetate (10 : 25 : 65, v/v/v) containing 0.1% formic acid at a flow rate of 0.25 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple‐reaction monitoring mode using the electrospray ionization technique in negative mode. The lower limits of quantification of gallic acid and ethyl gallate of the method were 0.5 and 1.0 ng/mL. The intra‐day and inter‐day accuracy and precision of the assay were less than 8.0%. This method has been applied successfully to a pharmacokinetic study involving the intragastric administration of ethyl gallate to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
We have developed and validated a simple detection system with high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) for determining cimetropium levels in human plasma using scopolamine butyl bromide as an internal standard (I.S.). The acquisition was performed in the multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 357.9 > 103.1 for cimetropium and m/z 359.9 > 103.1 for butyl-scopolamine. The method involves a simple single-step liquid-liquid extraction with dichloromethane. The analyte was chromatographed on an YMC C18 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer-methanol (19:81, v/v; adjusted to pH 4.0 with formic acid). The results were linear over the studied range (0.2-100 ng ml(-1)), with r2 = 1.0000, and the total analysis time for each run was 2 min. Intra- and interassay precisions were 0.70-8.54% and 1.08-4.85%, respectively, and intra- and interassay accuracies were 97.56-108.23% and 97.48-103.91%, respectively. The lower limit of quantification (LLOQ) was 0.2 ng ml(-1). At this concentration, mean intra- and interassay precisions were 8.54% and 4.85%, respectively, and mean intra- and interassay accuracies were 97.56% and 98.91%, respectively. The mean recovery ranged from 62.71 +/- 4.06 to 64.23 +/- 2.32%. Cimetropium was found to be stable in plasma samples under typical storage and processing conditions. The devised assay was successfully applied to a pharmacokinetic study of cimetropium bromide administered as a single oral dose (150 mg) to healthy volunteers.  相似文献   

20.
Atractylenolide II (AII) and atractylenolide III (AIII) are the major active components in Atractylodes Macrocephala Rhizoma (AMR). In this study, a sensitive, rapid and selective liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the simultaneous determination of AII and AIII in rat plasma using loliolide as internal standard (IS). After protein precipitation with ethyl acetate, the analytes were injected into an LC‐MS/MS system for quantification. Chromatography was performed using a C18 column, eluting with water and acetonitrile (45:55, v/v) at 0.2 mL/min. All analytes including IS were monitored under positive ionization conditions by multiple reaction monitoring with an electrospray ionization source. The validated method was successfully applied to the pharmacokinetic study of AII and AIII in rat plasma after oral administration of AMR extract. The results provided a meaningful basis for evaluating the clinical applications of traditional Chinese medicine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号