首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
We report on a high-performance diode-laser spectrometer operating near 657 nm with narrow linewidth (<0.6kHz) , enhanced power (as much as 40 mW), and low drift (<10Hz/s) . The spectrometer comprised an extended-cavity diode-laser frequency stabilized to a high-finesse optical resonator and a broad-area antireflection coated laser diode as an amplifier with a single-lobe emission pattern of good spatial purity. The spectrometer was used to record time-domain optical Ramsey spectra of laser-cooled Ca atoms with a resolution of 0.6 kHz.  相似文献   

2.
王文丛  梁静秋  梁中翥  吕金光  秦余欣  田超  王维彪 《物理学报》2014,63(10):100701-100701
为满足红外成像光谱仪大光通量、高稳定性的应用需求,提出了一种基于多级阶梯微反射镜的静态化、无狭缝式、新型红外时空联合调制型傅里叶变换成像光谱仪结构.对其工作原理和光程差的产生方式进行了分析.作为该成像光谱仪的重要部件,前置成像系统决定了光程差的分布,其性能直接影响到目标物体的图像质量.根据系统光程差的产生方式,分析和设计了像方远心光路结构的前置成像系统.利用被动光学消热差方法对前置成像系统进行了消热差研究.结果表明:当温度在-20—60?C的范围内时,各个视场的调制传递函数均达到衍射极限,在多级阶梯微反射镜的总阶梯高度范围内成像质量良好;在不同的温度下,各视场处主光线在像面上的最大入射角小于0.02?.  相似文献   

3.
便携式空间外差拉曼光谱仪集成了光学功能镜头、干涉仪组件,以及探测器和激光器等热辐射器件,因此仪器在使用过程中存在着较为复杂的热环境,环境温度变化导致光学系统性能下降。采用光机热集成分析方法,重点研究了环境温度及热辐射器件对关键器件成像镜头的性能影响。在便携式空间外差拉曼光谱仪光学和结构方案设计的基础上,建立热-结构耦合模型;仿真得到成像功能镜头内镜片的间距和面形的变化,并利用Zernike多项式拟合其变化;将拟合结果代入光学设计软件中进行成像质量评估和分析。结果表明,在使用环境温度(-10℃~40℃)范围内,调制传递函数在光谱仪截止频率76.9 lp/mm处对比度均优于0.38,满足便携式空间外差拉曼光谱仪的使用要求。  相似文献   

4.
编码孔径成像光谱仪光学系统设计   总被引:1,自引:0,他引:1       下载免费PDF全文
裴琳琳  吕群波  王建威  刘扬阳 《物理学报》2014,63(21):210702-210702
本文设计了一种以双Amici棱镜为分光元件的成像光谱系统,该系统主要包括前置望远物镜、编码板、双Amici棱镜、准直镜和成像镜.此类光学系统可以获得很高的衍射效率,相比于狭缝结构的成像光谱系统,该光谱仪为两维空间扩展的视场,无疑增加了设计难度.后期的数据反演算法对一次像面编码板的成像效果过于依赖,基于此,对光学系统的像差校正提出了更高的要求.本文设计、分析了基于双Amici棱镜的成像光谱仪的原理及特点,设计了一套完整的成像光谱系统.前置望远物镜的设计为像方远心,MTF在39线对处,达到0.8,成像质量良好.创新性的将前置望远物镜倒置用做准直系统.全系统各个波长在39线对处的MTF值均在0.65以上.对室外目标景物进行推扫成像,从获得的成像数据判断,本文设计的编码孔径成像光谱仪原理可行,衍射效率高,全视场成像质量良好,全谱段光谱数据可信.  相似文献   

5.
为了探究Czerny-Turner(CT)光路结构在装配过程中各个光学元件偏离理论光学设计参量时对光谱仪光学性能的影响,建立数学物理模型还原Zemax设计的非对称CT结构光路,在不影响光谱仪分辨率的条件下,调节CT结构中的各元件,得到各元件的可调节冗余量.结果表明,准直镜和衍射光栅偏转角度可调节范围分别为±0.19°和±0.17°;聚光镜和CCD的位置可调节范围都为±0.12mm.以上四个变量的可调节冗余量最小,对光谱仪最终分辨率影响较大.该研究对CT结构中各光学元件机械调节机构的设计具有参考意义.  相似文献   

6.
微型光谱仪光学结构研究   总被引:6,自引:2,他引:4  
王晗  李水峰  刘秀英 《应用光学》2008,29(2):230-233
光谱仪是光谱学和光谱技术中最基本的分析仪器之一,仪器的小型化对于扩展仪器使用范围有很大的帮助。设计一种微型可见光CCD摄像光谱仪的光学结构,通过理论计算,选用合适的光纤、平面定向光栅和凹面反射镜,并将它们合理组合,采用聚焦反射和分光的方法,将待测光进行色散,直接投射到CCD接收器件的表面。最后对设计的仪器性能进行了分析。结果表明:仪器的光学结构大大简化,整体尺寸减小,且精度有一定程度的提高。  相似文献   

7.
The feasibility of using a mass spectrometer for monitoring the carbon dioxide and inhalational anesthetic concentrations in the breathing circuit of an apparatus for inhalational anesthesia are demonstrated. Mass-spectrometric data for the CO2 and inhalational anesthetic concentrations are compared with related optical data. The advantages of the mass spectrometer as a capnograph over the optical spectrometer are indicated. The variation of the inhalational anesthetic content in expired air is shown to depend on the muscle relaxation efficiency.  相似文献   

8.
ARL3520型ICP顺序扫描光谱仪的改造技术   总被引:1,自引:0,他引:1  
在仔细研究了ARL3520型ICP顺序扫描光谱仪的整体结构及控制电路的基础上,根据被改造仪器的实际情况,保留其分光系统、驱动电路和执行部件,用一台新型通用替换原有的专用计算机系统;通过一块接口板,实现由微机直接实时控制ICP光谱仪的顺序扫描,重新设计了光电测量电路;重新开发了基于Windows95操作平台的ICP实时分析软件。  相似文献   

9.
针对传统光谱仪体积大、成本高、检测速度慢、需样品前处理等不足,提出了利用数字微镜面阵(DMD)实现光谱谱面分割分时选通的近红外光谱仪光学系统.首先,对比传统光路介绍单探测器微型光谱仪系统测量原理|然后结合DMD特性提出光路方案,根据几何光学原理进行初步光学元件选型和光路结构设计,利用ZEMAX光学软件对光路进行仿真,确定结构参数|最后,搭建实验平台,进行光路测试.实验结果表明:该系统光路尺寸为70 mm×130 mm,测量波段为(900~1 500 nm),分辨率可达19 nm|在能量损失较小的情况下,减小狭缝尺寸可提高光学分辨率,狭缝的极限尺寸为200 μm|减小狭缝子午面高度可减小谱面内弯曲现象.本系统基本满足近红外分光,实现单点探测器光谱测量的要求.  相似文献   

10.
刘日龙  刘木华 《应用光学》2015,36(3):460-462
摆镜扫描傅里叶变换光谱仪利用摆动扫描方式产生光程差,减小了因动镜倾斜带来的误差影响。从摆扫干涉光谱技术原理出发,对摆镜扫描傅里叶变换光谱仪的光程差进行理论分析,给出了光程差计算表达式,实验结果表明:该光谱仪光程差近似正比于摆动角度。分析了轴外光线因不同入射角所产生的附加光程差,为傅里叶变换光谱仪的指标确定和优化设计提供了理论依据。  相似文献   

11.
近红外微型光谱仪光学系统设计与模拟   总被引:3,自引:0,他引:3  
基于光谱仪基本工作原理和光学设计理论,以系统微型化、且能满足一定光谱范围和分辨率要求为具体设计目标,提出了基于平面衍射光栅分光的交叉式C-T结构的近红外微型光谱仪光学系统结构方案。采用ZEMAX软件对近红外微型光谱仪的分光系统、成像系统进行了优化设计与模拟分析。最终设计与模拟分析结果表明,该光学系统光谱范围为900~1 700 nm,分辨率<10 nm,谱面展宽为12.74 mm,F数为8.128 388,系统体积为51.26 mm×41.81 mm×22 mm。  相似文献   

12.
This paper presents a 900-1700 nm hyper-spectral imaging spectrometer which offers low distortions, a low F-number, a compact size, an easily-fabricated design and a low cost (is presented in this paper). The starting point for its optical design is discussed according to the geometrical aberration theory and Rowland circle condition. It is shown that these methods are useful in designing a push-broom hyper-spectral imaging spectrometer that has an aperture of f/2.4, modulation transfer functions of less than 0.8 at 25 cycles/mm, and spot sizes less than 10 μm. A prototype of the optimized hyper-spectral imaging spectrometer has been fabricated using a high precision machine and the experimental demonstration with the fabricated hyper-spectral imaging spectrometer is presented.  相似文献   

13.
吴彤  孙帅帅  王绪晖  王吉明  赫崇君  顾晓蓉  刘友文 《物理学报》2018,67(10):104208-104208
相比传统光谱仪,基于线性波数光谱仪的谱域光学相干层析(OCT)无需对非线性波数干涉光谱数据进行重采样和插值,可大大减少数据计算量并提高成像灵敏度.通过模拟计算干涉光谱信号和点扩散函数,以点扩散函数半峰全宽值的倒数作为评价准则,可以优化包括色散棱镜材料的折射率、顶角角度以及衍射光栅和色散棱镜之间旋转角角度的线性波数光谱仪的结构参数.根据优化结果,实验中选用F2玻璃等边色散棱镜,以光栅-棱镜间旋转角角度为21.8°搭建了最优化线性波数光谱仪,并引入谱域OCT成像系统.实验测得成像系统的轴向分辨率达到8.52μm,灵敏度达到91 dB,6 dB成像深度达到1.2 mm.结合具有通用并行计算能力的图形处理卡,在无需重采样和插值的情况下可实时处理和显示人手指指甲皮肤接缝处的横断面OCT图像,验证了基于最优化线性波数光谱仪的谱域OCT系统的成像性能.  相似文献   

14.
在时间调制傅里叶变换光谱仪中,直线运动型动镜很难精确驱动,容易引起倾斜和剪切的问题。旋转型动镜可以解决该类问题。介绍了一种转镜式傅里叶变换光谱仪方案,并对其进行了原理分析和光程差公式推导,提出了工程设计约束条件。该光谱仪由一个分束器,两个固定平面镜,两面平行固定在一个转轴上旋转的平面反射镜,前置镜,后置镜及探测器组成。通过原理介绍得出,该光谱仪结构简单,两条分光光线经同一平面镜反射后干涉,使仪器更容易装调;通过光程差推算得出,该光谱仪容易实现大光程差,光谱分辨率高;通过工程设计约束及仿真分析得出,该光谱仪需要在高速旋转的条件下实现高分辨率采样,容易实现精确运动控制,稳定性好,测量速度快。  相似文献   

15.
为实现红外光谱仪器的小型化,通过分析现有小型光谱仪,提出了一种基于平板波导的小型红外光栅光谱仪的设计方法。平板波导光谱仪的小型化原理与一般的微小型光谱仪不同。在平板波导光谱仪中,光束被限制在一层薄薄的平板波导介质中传播,看起来像是整个光学系统被压扁了。在垂直于平板波导的方向上光学元件的尺寸可以做到很小,从而显著减小光学系统的尺寸。该系统的设计可分为Czerny-Turner结构设计、波导结构设计。先根据像差理论设计Czerny-Turner结构,目标是保证光谱分辨率及校正像差;然后根据几何光学理论设计波导结构,包括平板波导和两个柱面透镜,目标是压缩光束并校正像散;最后将它们输入Zemax软件中进行综合优化,以获得最优的光学系统。据此方法设计了一个平板波导红外光栅光谱仪,工作波段为8~12 μm,数值孔径为0.22,采用线阵探测器。通过Zemax软件对结果进行分析和评价,表明仪器光学系统的尺寸为130 mm×125 mm×20 mm,工作波段内光谱分辨率达到80 nm,满足设计指标要求。证明了该优化设计方法是可行的,所得系统尺寸小、性能高。  相似文献   

16.
宽波段高分辨率小型紫外成像光谱仪光学系统研究   总被引:1,自引:0,他引:1  
结合小型紫外光谱仪器设计原理对紫外成像光谱仪进行了研究。以离轴抛物镜为望远镜,超环面光栅为成像光谱系统设计了系统方案;该光学系统的优化设计就是对超环面光栅的参数设计。分析了光栅的光程函数和像差方程,总结了单超环面光栅结构的完善聚焦条件和完善成像条件;这两种条件无法在代数计算下得到完善代数解,限制了光谱仪的工作波段和视场,引入遗传算法解决了这个问题。以一工作波段为200~280 nm的日盲紫外成像光谱仪为例对设计理论进行验证,根据优化理论计算了初始结构最优解并进行光线追迹模拟,成功得到了F数为5.7,焦距为102 mm,全视场全波段调制传递函数值在奈奎斯特频率(20 lp·mm-1)下大于0.65的高分辨率成像光谱仪光学系统。设计结果表明这种光学系统设计理论适用于小型宽波段高分辨率紫外成像光谱仪。  相似文献   

17.
基于二元光学的红外成像光谱仪离轴系统设计   总被引:7,自引:7,他引:0  
对Lyons采用二元光学元件的红外成像光谱仪的设计理论进行了分析,为消除其二元光学元件作为透射式成像元件导致的焦距随波长的变化而变化的缺陷.提出将离轴三反射镜系统与具有二元光学透镜的变焦距系统相结合的新技术方案,并从军事目标的红外热探测的基本要求出发,给出了具体的设计实例.设计结果表明,系统具有设计精巧、结构简单、光能接收率高、消像差特性好、对材料的要求低以及满意的红外焦平面凝视阵列探测器的配准精度和探测精度.  相似文献   

18.
交叉非对称型Czerny-Turner光谱仪光学系统设计   总被引:1,自引:0,他引:1  
根据Czerny-Turner结构光谱仪工作原理,以便携式微型光学系统为设计目标,设计了一种光谱范围为200900nm的交叉非对称型Czerny-Turner光谱仪光学系统.通过分辨率、光谱范围等设计要求确定光谱仪大致结构后,引入初级像差对初始结构进行进一步优化.首次提出将球差约束条件与光阑面选取相结合,设计流程确定准直镜通光口径、光栅初始尺寸及聚焦镜中心波长对应口径,继而结合彗差约束条件,确定球面镜离轴角,并基于几何光学确定聚焦镜初始通光口径的方法.利用ZEMAX软件对初始参量进行模拟优化,并采用自主研制的样机进行光谱测量,分析结果表明,该光学系统能够在狭缝宽度为25μm,光栅常数为1.667μm/line条件下,实现中心波长分辨率优于1nm,边缘波长分辨率优于1.5nm.  相似文献   

19.
一种光栅型成像光谱仪光学系统设计   总被引:3,自引:2,他引:1       下载免费PDF全文
 成像光谱仪是一种“图谱合一”的光学遥感仪器。从光栅型成像光谱仪的使用要求出发,利用Zemax软件设计了一种光栅型成像光谱仪光学系统。其中,前置望远物镜采用反射式结构,传统的卡塞格林结构在主次镜均采用非球面时校正像差的能力依然有限,设计时采用改进后的卡塞格林结构对像差进行校正,最终设计的望远镜头传函在50 lp/mm处达到0.5,场曲控制在0.078以内,且不存在畸变。针对光谱成像系统通常采用的基于平面光栅的Czerny-Turner结构由于像差校正能力有限、成像质量较差不能满足仪器的使用要求。采用基于凸面光栅的光谱成像系统,该系统结构紧凑、可实现宽波段内像差的同时校正。最终设计的光谱成像系统光谱分辨率<5 nm,MTF在50 lp/mm时升至0.75。将前置望远物镜与光谱成像系统根据匹配原则进行组合优化后光栅型成像光谱仪系统点列图RMS半径随波长的变化均小于0.2,波长的80%的能量集中在Φ6 μm范围内,波长各视场在特征频率50 lp/mm处的光学传递函数均大于0.5。整个光学系统具有结构简单、像差校正能力强、结构尺寸较小的优点。  相似文献   

20.
针对目前紫外光谱仪热工况优化研究缺乏的问题,该文设计出一款探测范围为200 nm~450 nm、全波段分辨率不低于0.2 nm的罗兰圆光谱仪,并耦合光、热、结构模拟对其光室热工况开展优化研究。热仿真结果表明:在无加热、无入口风速下光谱仪底座温度、温差随时间不断增加,难以达到热平衡;优化光室入口风速,发现当入口风速为0.8 m/s时,整体温度降至36.103℃~39.859℃;基于光学器件间的热变形量的计算,光学器件截距总热变形量为0.203 mm;优化加热方式,发现顶层式加热方式最佳,整体温度降至34.241℃~36.139℃,光学器件截距总热变形量降至0.122 mm。对此进行光学仿真,结果表明,优化工况后的罗兰圆光谱仪工作热变形后可清晰分辨出两束波长相差0.2 nm的光束。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏