首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 576 毫秒
1.
Garg BS  Bist JS  Sharma RK  Bhojak N 《Talanta》1996,43(12):2093-2099
3-Hydroxy-2-methyl-1,4-naphthoquinone-immobilized silica gel has been used for the adsorption and estimation of copper, cobalt, iron and zinc by both batch and column techniques. The distribution coefficient D determined for each metal ion was as follows (ml g1): Fe, 3.6 × 102; Cu, 3.9 × 102; Co, 3.8 × 102; Zn, 4.1 × 102. Methods have been developed to estimate zinc, copper and cobalt in milk, steel and vitamin samples respectively.  相似文献   

2.
Puri BK  Balani S 《Talanta》1995,42(3):337-344
Iron, cobalt and copper form coloured water soluble anionic complexes with disodium 1-nitroso-2-naphthol-3-6-disulphonate (nitroso R-salt). The anionic complex is retained quantitatively as a water insoluble neutral ion associated complex (M-nitroso R-TDBA) on tetradecyldimethylbenzylammonium iodide on naphthalene (TDBA(+)I(-)-naphthalene) packed column in the pH range of: Fe(III): 3.1-6.5, Co: 3.4-8.5 and Cu 5.9-8.0 when their solutions are passed individually over this adsorbent at a flow rate of 0.5-5.0 ml/min. The solid mass consisting of an ion associated metal complex along with naphthalene is dissolved out of the column with 5 ml dimethylformamide/chloroform and metals are determined spectrophotometrically. The absorbance is measured at 710 nm for iron, 425 nm for cobalt and 480 nm for copper. Beers law is obeyed in the concentration range 9.2-82 mug of iron, 425 nm for cobalt cobalt and 3.0-62 mug of copper in 5 ml of final DMF/CHCl(3) solution. The molar absorptivities are calculated to be Fe: 7.58 x 10(3), Co: 1.33 x 10(4) and Cu: 4.92 x 10(4)M(-1)cm(-1). Ten replicate determinations containing 25 mug of iron, 9.96 mug of cobalt and 3.17 mug of copper gave mean absorbances 0.677, 0.450 and 0.490 with relative standard deviations of 0.88, 0.98 and 0.92%, respectively. The interference of large number of metals and anions on the estimations of these metals has been studied. The optimized conditions so developed have been employed for the trace determination of these metals in standard alloys, waste water and fly ash samples.  相似文献   

3.
Manganese, nickel, cobalt, and zinc are elements that appear together in many real samples. In this work, a simple, rapid, and sensitive method has been used for the simultaneous separation and preconcentration of trace amounts of these elements using water-soluble polyacrylic acid on alumina as a sorbent in a glass column system. A solution containing Mn, Ni, Co, and Zn was passed through the column at pH 7, and desorption was carried with 5.0 mL of 0.03 M nitric acid. Linearity was maintained between 0.25-5.0 x 10(3), 0.04-6.0 x 10(3), 0.10-8.0 x 10(3), and 0.028-1.0 x 10(3) ng/mL for Ni, Mn, Co, and Zn, respectively, in the original solution. Eight replicate determinations of a mixture containing 1.0 microg/mL of each of the elements in the final solution gave relative standard deviations of 1.4, 1.5, 2.4, and 1.2% for Ni, Mn, Co, and Zn, respectively. The sorption capacities for Mn (mg/g sorbent) obtained were 16.0 for Mn, 9.0 for Ni, 12.0 for Co, and 10.0 for Zn. By using 5.0 mL elution solution, preconcentration factors of 400, 500, 700, and 460 could be obtained for Ni, Mn, Zn, and Co, respectively.  相似文献   

4.
Bobrowski A 《Talanta》1994,41(5):725-729
The catalytic adsorptive stripping voltammetric method with alpha-benzil dioxime and nitrite affords numerous advantages in cobalt determination. The detailed conditions of the determination of the cobalt traces in metallic zinc by catalytic adsorptive stripping voltammetry have been investigated. Both the linear sweep and the differential pulse stripping modes can be used with similar sensitivity. Possible interferences by Mn, Pb, Cu, Ni and Fe are evaluated. In the presence of 5 x 10(5) fold excess of Zn the linear dependence of the cobalt CASV peak current on concentration ranged from 0.05 mug/l to 3 mug/l. Optimal conditions include the accumulation potential of -0.65 V and the accumulation time of 10 sec. The results of the determination of 10(-5)% level of Co in the metallic zinc showed good reproducibility (relative standard deviation, RSD = 0.07) and reliability.  相似文献   

5.
Weng YQ  Yue F  Zhong YR  Ye BH 《Inorganic chemistry》2007,46(19):7749-7755
A new copper(II) fluorescent sensor 5,10,15,20-tetra((p-N,N-bis(2-pyridyl)amino)phenyl)porphyrin zinc (1) has been designed and synthesized by the Ullmann-type condensation of bromoporphyrin zinc with 2,2'-dipyridylamine (dpa) under copper powder as a catalyst as well as with K2CO3 as the base in a DMF solution. It consists of two separately functional moieties: the zinc porphyrin performs as a fluorophore, and the dpa-linked-to-zinc porphyrin acts as a selected binding site for metal ions. It displays a high selectivity and antidisturbance for the Cu2+ ion among the metal ions examined (Na+, Mg2+, Cr3+, Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Ag+, Zn2+, Cd2+, Hg2+, and Fe3+) and exhibits fluorescence quenching upon the binding of the Cu2+ ion with an "on-off"-type fluoroionophoric switching property. The detection limit is found to be 3.3 x 10(-7) M (3s blank) for Cu2+ ion in methanol solution, and its fluorescence can be revived by the addition of EDTA disodium solution. The design strategy and remarkable photophysical properties of sensor 1 help to extend the development of fluorescent sensors for metal ions.  相似文献   

6.
对临床、病理、放射线或CT检查确诊的82名癌肿患者,在放疗前后和对42名健康人进行了微量元素铁、锌、铜、锰、硒,铬、钴、镍的分析。研究结果显示:1.癌肿患者血清铜、镍、锰、铬、钴的含量比健康人高,而血清锌、铁、硒的含量却比健康人低;2.血清Cu/Zn、Cr/Zn、Co/Zn、Ni/Zn的比值癌肿患者均比健康人高,而Fe、Zn、Se/Zn的比值却相反。因此,可根据血清铜升高、血清锌降低,血清铜/锌比值升高的特点。用于癌肿的早期诊断;3.癌肿患者放疔后血清铁、锌含量进一步下降,铜、锰、铬的含量也出现降低,唯有硒的含量有所上升。因此,放疗时应注意补充铁、锌、铜元素。  相似文献   

7.
Surfactant anion intercalated hydroxy salts of copper and cobalt of the formula M(OH)2- x (surf)x.mH2O [M = Cu, Co; surf = dodecyl sulfate, dodecyl benzene sulfonate, and x = 0.5 for Cu and 0.67 for Co] delaminate readily in 1-butanol to give translucent colloidal dispersions that are stable for months. The extent of delamination and the colloidal dispersion observed in these solids is higher than what had been observed for layered double hydroxides. The dispersions yield the corresponding nanoparticulate oxides on solvothermal decomposition. While the copper hydroxy salt forms approximately 300 nm dendrimer-like CuO nanostructures comprising nanorods of approximately 10 nm diameter, the cobalt analogue forms approximately 20 nm superparamagnetic particles of Co3O4.  相似文献   

8.
Hirata S 《Talanta》1981,28(11):809-815
The molecular-weight distributions of fulvic and humic acids in sediments and their complexes with metal ions (Cu(2+), Zn(2+), Mn(2+)) were investigated by gel filtration. In all cases, metal complexes were found in the fulvic and humic acids. In the complexes the metals were bound to the high molecular-weight fulvic and humic polymers. By use of gel filtration, stability constants for the complexes of copper, zinc and manganese with fulvic acids have been measured. Scatchard plots indicate the presence of two classes of binding site with stability constants of 2.3 x 10(7) and 1.4 x 10(6) for copper, 2.1 x 10(6) and 6.6 x 10(4) for zinc and 1.8 x 10(5) and 7.3 x 10(3) for manganese, respectively.  相似文献   

9.
Goswami A  Singh AK  Venkataramani B 《Talanta》2003,60(6):1141-1154
The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQx) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and Co(II) prior to their determination by flame atomic absorption spectrometry. The surface area of the modified silica gel has been found to be 227 m2 g−1 and the two pKa values as 3.8 and 8.0. The optimum pH ranges for quantitative sorption are 4.0–7.0, 4.5–7.0, 3.0–6.0, 5.0–8.0, 5.0–8.0, 5.0–8.0 and 4.0–7.0 for Cu, Pb, Fe, Zn, Co, Ni and Cd, respectively. All the metals can be desorbed with 2.5 mol l−1 HCl or HNO3. The sorption capacity for these metal ions is in range of 92–448.0 μmol g−1 and follows the order Cd3, NaCl, NaBr, Na2SO4 and Na3PO4, glycine, sodium citrate, EDTA, humic acid and cations Ca(II), Mg(II), Mn(II) and Cr(III) in the sorption of all the seven metal ions are reported. The preconcentration factors are 150, 250, 200, 300, 250, 300 and 200 for Cd, Co, Zn, Cu, Pb, Fe and Ni, respectively and t1/2 values <1 min except for Ni. The 95% extraction by batch method takes ≤25 min. The simultaneous enrichment and determination of all the metals are possible if the total load of the metal ions is less than sorption capacity. In river water samples all these metal ions were enriched with the present ligand anchored silica gel and determined with flame atomic absorption spectrometer (R.S.D.≤6.4%). Cobalt contents of pharmaceutical samples (vitamin tablet) were preconcentrated with the present chelating silica gel and estimated by flame AAS, with R.S.D.1.4%. The results are in the good agreement with the certified value, 1.99 μg g−1 of the tablets. Iron and copper in certified reference materials (synthetic) SLRS-4 and SLEW-3 have been enriched with the modified silica gel and estimated with R.S.D.<5%.  相似文献   

10.
Isothermal calorimetry was used to determine enthalpy changes for interaction of divalent cobalt, nickel, copper, and zinc chlorides with silica gel functionalized with vanillin, Sil-Van. The thermal effect, Q(int), and the corresponding amount of cation that interacts, n(int), were obtained in the same experiment. Langmuir expressions for adsorption isotherms were applied to determine the maximum adsorption capacity to form a monolayer, N(mon), and the energy of interaction for a saturated monolayer per gram of Sil-Van, Q(mon). From knowledge of N(mon) and Q(mon), the molar enthalpy of interaction for formation of a monolayer of anchored cations per gram of Sil-Van, Delta(mon)H(m), was determined. Interactions between the Lewis-acidic cations and the donor atom attached to silica are reflected by Delta(mon)Hm values in the order Ni2+ > Cu2+ > Zn2+ congruent with Co2+.  相似文献   

11.
Thin layer chromatography(TLC) of cobalt and nickel has been performed on silica gel layers induced with alkali mediated cellulose extract.A novel combination of 10% aqueous solutions of Tween-20 and potassium thiocyanate in 1∶1(v/v) was identified as the best mobile phase for the selective separation of Co2+from Ni2+on the impregnated Silica Gel G layers.The chromatographic characteristics of the cations were studied and the limits of detection as well as the limits of quantification for Co2+and Ni2+were determined.The quantitative estimation of the cations was achieved from the digital image analysis of respective chromatograms.The proposed quantitative method was successfully applied with 0-0.50% error for the determination of Co2+from Ni2+in spiked samples of bauxite,soil and rock containing common cations such as Al3+,Fe2+,Ti4+,Zn2+,Mn2+,Cu2+,Cr6+,Mg2+,etc.under the optimized chromatographic conditions.  相似文献   

12.
The distribution patterns and the organ-specific accumulation trends of 10 trace metals (iron, manganese, zinc, copper, chromium, nickel, cobalt, lead, cadmium and silver) and 4 major elements (sodium, potassium, calcium and magnesium) in 10 different tissues (heart, muscle, kidney, stomach, intestine, liver, gill, gonads, white skin and dark skin) of a benthic fish species (Solea senegalensis) from a densely populated coastal area affected by anthropogenic activities, the Bay of Cadiz (SW Spain), have been investigated. High variability of metal concentrations among tissues were found for Ca, Fe, Zn, Cu, Pb and Ag. Factor analysis was applied to study this variability. Five principal components were found explaining the 92.95% of the total variance and similarities in behavioural patterns of bioaccumulation were described. They associated Mg, Cr, Ni and Mn to intestine and stomach tissues (PC1), Ag, Cu and Cd to liver (PC2), Zn, K and Co to gonads (PC3), Na, Fe and Pb to gill, heart and kidney tissues (PC4) and Ca, Pb and Mn to gill and dark skin (PC5). The metallic concentration in the sediment and water was also studied. The pollution in this area was found moderate with outstanding values of Zn, Cu and Pb (average values of 139, 50.4 and 75.6?mg?kg?1, respectively) in sediment and dissolved Cu (average value of 2.5?µg?L?1). Metal bioconcentration trends followed the order Zn?>?Cu?>?Cd?>?Pb for dissolved metals in seawater, Cu?>?Zn?>?Cd?>?Pb?≈?Mn?>?Fe?≈?Ni?≈?Co for metals associated to particulate matter and Zn?≈?Cu?>?Cd?>?Mn?>?Co?≈?Fe?>?Ni?≈?Pb?>?Cr for metals in the sediment. Higher values were found for copper in liver, zinc in gonads and lead in gill, showing the relationship between biotic and abiotic environment. In addition, Cd bioconcentration factors were found high in liver and gill showing the sensitivity of sole to this metal even at low concentrations.  相似文献   

13.
A chelating matrix prepared by immobilizing 1,8-dihydroxyanthraquinone on silica gel modified with 3-aminopropyltriethoxysilane has been characterized by use of cross-polarization magic angle spinning (CPMAS) NMR, diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy, and thermogravimetric analysis and used to preconcentrate Fe(III), Co(II), Ni(II), and Cu(II) before their determination by flame atomic absorption spectrometry. The optimum pH ranges for quantitative sorption are 6.5-8.0, 6.0-7.0, 6.0-8.0, and 7.0-8.5 for Cu, Fe, Co, and Ni, respectively. All the metal ions can be desorbed with 2 mol L(-1) HCl or HNO3. The sorption capacity ( micromol g(-1) matrix) and preconcentration factor were 226.6, 250; 365.6, 300; 101.8, 150; and 109.0, 250 for Cu, Fe, Co, and Ni, respectively. The lowest concentration for quantitative recovery was 4.0, 3.3, 6.6, and 4.0 ng mL(-1), respectively for the four metal ions. The limits up to which electrolytes NaNO3, NaCl, NaBr, Na2SO4, and Na3PO4 and cations Ca(II) and Mg(II) can coexist with the four metal ions during their sorption without adverse effect are reported. The simultaneous enrichment and determination of all the four metals is possible if the total load of metal ions is less than the sorption capacity. Flame AAS was used to determine the metal ions in underground, tap, and river water samples (RSD相似文献   

14.
《Analytical letters》2012,45(9):1807-1820
ABSTRACT

5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g?1): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(II)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).  相似文献   

15.
A new method for the simultaneous determination of five transition metal ions in water and food by rapid high‐performance liquid chromatography was developed. The cobalt, nickel, copper, zinc and vanadium ions were pre‐column derivatized with 2‐(2‐quinolinylazo)‐4‐methyl‐1,3‐dihydroxidebenzene (QAMDHB) to form colored chelates, then the Co‐QAMDHB, Ni‐QAMDHB, Cu‐QAMDHB, Zn‐QAMDHB and V‐QAMDHB chelates were enriched by solid phase extraction with a C18 cartridge. The enrichment factor of 50 was achieved by eluting the retained chelates from the cartridge with tetrahydrofuran (THF). These chelates were separated on a ZORBAX Stable Bound rapid analysis column (4.6 × 50 mm, 1.8 um) with 68% methanol (containing 0.1% of acetic acid and 0.1% of CTMAB) as mobile phase at a flow rate of 2.0 mL/min and detected with a photodiode array detector from 450?600 nm. The Co‐QAMDHB, Ni‐QAMDHB, Cu‐QAMDHB, Zn‐QAMDHB and V‐QAMDHB chelates were separated completely within 2.0 min. The detection limits of cobalt, nickel, copper, zinc and vanadium are 2 ng/L, 1.5 ng/L, 2 ng/L, 3 ng/L, and 3 ng/L, respectively, in the original samples. This method was applied to the determination of the five transition metal ions in water and food samples with good results.  相似文献   

16.
Cefadroxil (CD) is an essential pharmaceutical drug used in curing many diseases. Due to its popular use in many pharmaceutical forms, attention is paid in this research to the synthesis and stereochemistry of new iron, cobalt, nickel, copper, and zinc complexes of this drug both in solution and the solid states. The spectra of these complexes in solution and the study of their stoichiometry refer to the formation of 1:1 and 1:2 ratios of metal (M) to ligand (L). The calculated stability constants (Kf) of these complexes (1.5x10(7) to 5x10(13)) and the change in free energy of formation (deltaGf=2.5-12.5 kcal mol(-1) degree(-1)) are indicative of their high stability. The stereo chemical structure of the solid complexes was studied on the basis of their analytical, spectroscopic, magnetic, and thermal data. Infrared spectra proved the presence of M-N and M-O bonds. Magnetic susceptibility and solid reflectance spectral measurements were used to infer the structure. The prepared complexes were found to have the general formulae [ML(OH)x(H2O)y](H2O)z-M: Fe(II), x=0, y=2, z=1; M: Fe(III) and Co(III), x=1, y=2, z=1; M: Co(II) and Zn(II), x=0, y=1, z=0; M: Ni(II) and Cu(II), x=1, y=0, z=1; L: CD. Octahedral and tetrahedral structures were proposed for these complexes depending upon the magnetic and reflectance data and were confirmed by detailed mass and thermal analyses comparative studies.  相似文献   

17.
痕量Fe^3 ,Mn^2 ,Cu^2 ,Zn^2 ,Co^2 ,Ni^2 与2-(5-溴-2-吡啶偶氮)-5-二乙氨基苯酚(5-Br-PADAP)和溴化十六烷基三甲基铵(CTMAB)在PH8.3时发生高灵敏显色反应,所形成的三元胶束络合的吸收光谱严重重叠,采用偏最小二乘法(PLS)辅助分光光度法测定了合成试样及饲料中上述6种痕量组分,结果表明,PLS法是化学计量学中一种可适用于基体较复杂的实际试样中痕量组分分光度同时测定的多元计算方法。  相似文献   

18.
A combined adsorption procedure for the analytical fractionation of humic/metal complexes in river water is described. It is based on an indium-loaded XAD-2 resin and a DEAE-Sephadex A-25 anion exchanger, respectively. After the separation of suspended particles, an aliquot of the water sample to be analysed is passed through an indium-loaded XAD-2 resin column to collect the metal-humic complexes. A second aliquot is directly passed through a DEAE-Sephadex A-25 anion exchanger column to collect humic complexes and other negatively charged metal species. Both column effluents are analysed by inductively coupled plasma-mass spectrometry or by graphite-furnace atomic absorption spectrometry for various trace metals (e.g., Al, Mn, Fe, Co, Ni, Cu, Zn, Sr, Ba). According to this fractionation procedure, significant amounts of iron, aluminium and copper in river water are found to be humic complexes, and less than 15% of nickel, cobalt and zinc are complexed with humic substances. Manganese, strontium and barium are hardly associated with humic substances.  相似文献   

19.
Sarkar AR  Datta PK  Sarkar M 《Talanta》1996,43(11):1857-1862
Trace metals in water were preconcentrated with silica gel modified with salicylaldoxime and determined by AAS. Optimum conditions for the maximum recovery of metal ions, viz. Cu(II), Ni(II), Co(II), Zn(II) and Fe(III), for both batch and column methods were developed. The efficiency of the adsorbent with respect to different experimental conditions was established.  相似文献   

20.
Watanesk S  Schilt AA 《Talanta》1986,33(11):895-899
A metal-ion extractant, prepared by chemical binding of 2-pyridinecarboxaldehyde phenylhydrazone on a silica support, is described and shown to be effective for use in separation and determination of trace amounts of iron, cobalt, nickel, and copper. Metal-ion sorption conforms to the Langmuir isotherm. The relative orders of the Langmuir constants K and the column retention-capacity factors k' for the four transition-metal ions are the same as the natural order of the stabilities predicted for their metal chelates: Fe(II) < Co(II) < Ni(II) < Cu(II).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号