首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
S. Losada  M.T. Galceran 《Talanta》2009,80(2):839-91
A fast and simple method for the analysis of polybrominated diphenyl ethers (PBDEs) in fish samples was developed using a one-step extraction and clean-up by means of pressurized liquid extraction (PLE) combined with gas chromatography-ion trap tandem mass spectrometry (GC-ITMS-MS). The selective PLE method provided to obtain ready-to-analyse extracts without any additional clean-up step, using a sorbent as fat retainer inside the PLE cell. Several PLE operating conditions, such as solvent type, extraction temperature and time, number of cycles and type of fat retainer, were studied. Using Florisil as fat retainer, maximum recoveries of PBDEs (83-108%) with minimum presence of matrix-interfering compounds were obtained using a mixture of n-hexane:dichloromethane 90:10 (v/v) as solvent, an extraction temperature of 100 °C and a static extraction time of 5 min in combination with three static cycles. Quality parameters of the method were established using standards and fish samples. Limits of detection and quantification ranged from 10 to 34 pg g−1 wet weight and between 34 and 68 pg g−1 wet weight, respectively. In addition, good linearity (between 1 and 500 ng ml−1) and high precision (RSD % < 15%) were achieved. The method was validated using the standard reference material SRM-1945 (whale blubber) and was then applied to the analysis of PBDEs in fish samples.  相似文献   

2.
Isoflavone derivatives from freeze-dried soybeans were extracted by pressurized liquid extraction (PLE) and determined by reverse-phase high performance liquid chromatography (HPLC) with both photo diode array and mass spectrometry (MS) detection. Both real and spiked samples were used in the development of the method.Several extraction solvents (methanol (MeOH) and ethanol (EtOH), 30-80% in water and water), temperatures (60-200 °C), pressures (100-200 atm), as well as the sample size (0.5-0.05 g) and cycle length (5-10 min) were studied for the optimization of the extraction protocol. The optimized extraction conditions for quantitative recoveries were: 0.1 g of sample, 100 °C, three (7 min) static extraction cycles and ethanol 70% as extracting solvent. The stability of the isoflavones during the PLE was also determined. Under PLE conditions, degradation of malonyl glucoside forms of the isoflavones takes place using temperatures higher than 100 °C whereas degradation of glucosides takes place above 150 °C. Using the optimized protocol, isoflavones can be extracted from freeze-dried soybeans without degradation.  相似文献   

3.
Modern extraction technique-pressurized liquid extraction (PLE) was optimised for extraction of lycorine and galanthamine (Amaryllidaceae alkaloids) from Narcissus jonquilla ‘Pipit’. Crude extracts were purified on Oasis MCX cartridges, and the alkaloids eluted with 80-100% recoveries using methanol-10% ammonia solution (3:1, v/v). Quantitative results were obtained by both HPTLC-densitometry on silica gel plates and RP-HPLC with diode array (DAD) on XTerra C18 stationary phase. Both methods were fully validated in terms of specificity, precision (including intra- and inter-day measurements), LOD and LOQ values, correlation of UV spectra and linearity of calibration curves. The methods were also well correlated each other with correlation coefficients (r) 0.98823 and 0.99081, respectively, for the mean values of galanthamine and lycorine.Among the investigated solvents methanol and 1% tartaric acid methanolic solution at default conditions (120 °C, p = 60 bar, time: 10 min, one static cycle) permit the highest yields of the total sum of the alkaloids, whereas for toluene the lowest amounts were measured. Lycorine to galanthamine mean ratios were dependant on the type of solvent used, and in toluene galanthamine and related alkaloids were preferably extracted.In temperature experiments for galanthamine, the levels of this compound increased from the temperature of 20 till 150 °C in the investigated solvent systems, then decreased with slight increase from the temperature of 175 to 200 °C in 1% tartaric acid methanolic solution. When lycorine was analysed, similar trends were observed, however the maximum of the concentration was measured at a temperature about 125 °C. The ratios of the mean values of these two compounds differed in temperature-dependant experiments in both solvent systems.Further more, two TLC with bioautography approaches were used in screening for anticholinesterese properties of the extracts. No qualitative differences were found among the different solvent extracts, and AChE inhibition was correlated with galanthamine and related compounds.In conclusion, optimised PLE was much more effective than previously applied hot-solvent extraction, microwave-assisted extraction (MAE) or ultrasound-assisted extraction (USAE).  相似文献   

4.
In the present study, we have developed a method based on pressurized liquid extraction (PLE) and liquid chromatography with fluorescence detection (LC-FLD) for the determination of residues of fluoroquinolones (FQs) in infant food products. PLE extraction has been optimized by the application of experimental design methodologies. Initially, a fractional factorial design (FFD) was used to screen the significance of four extraction parameters: solvent composition, temperature, pressure and number of cycles. The most significant factors, identified by ANOVA analysis, were the solvent composition, temperature and pressure, which were further optimized with the aid of a face centred design (FCD) and the desirability function. The optimized operating PLE conditions were as follows: ACN/o-phosphoric acid 50 mM pH 3.0 (80:20, v/v), 80 °C, 2000 psi and three extraction cycles of 5 min. Under these conditions, recoveries of the target FQs varied between 69% and 107% with RSDs below 9%. The whole method was validated according to the Commission Decision 2002/657/EC guidelines. The proposed method has been successfully applied to the analysis of different infant food products bought in local supermarkets and pharmacies. The results showed the presence of residues of enrofloxacin in a non-compliant baby food sample corresponding to a chicken-based formulation, which were also confirmed and quantified by LC–MS/MS analysis.  相似文献   

5.
Pressurized liquid extraction (PLE) is a relatively new technique applicable for the extraction of persistent organic pollutants from various matrices. The main advantages of this method are short time and low consumption of extraction solvent. The effects of various operational parameters (i.e. temperature of extraction, number of static cycles and extraction solvent mixtures) on the PLE efficiency were investigated in this study. Fish muscle tissue containing 3.2% (w/w) lipids and native polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and other related compounds was used for testing. Purification of crude extracts was carried out by gel permeation chromatography employing Bio-Beads S-X3. Identification and quantitation of target indicator PCBs and OCPs was performed by high-resolution gas chromatography (HRGC) with two parallel electron-capture detectors (ECDs). Results obtained by the optimized PLE procedure were compared with conventional Soxhlet extraction (the same extraction solvent mixtures hexane–dichloromethane (1:1 v/v) and hexane–acetone (4:1 v/v) were used). The recoveries obtained by PLE operated at 90–120 °C were either comparable to “classic” Soxhlet extraction (for higher-chlorinated PCB congeners and DDT group) or even better (for lower chlorinated analytes). The highest recoveries were obtained for three static 5 min extraction cycles.  相似文献   

6.
Pressurized liquid extraction (PLE), commonly used for organic compounds extraction, has been applied for trace element leaching from marine biological material in order to determine major and trace elements (Al, As, Cd, Co, Cu, Fe, Hg, Li, Mn, Pb, Se, Sr, V and Zn). The released elements by formic acid PLE have been evaluated by inductively coupled plasma-optical emission spectrometry (ICP-OES). Different variables, such as formic acid concentration, extraction temperature, static time, extraction steps, pressure, mean particle size and diatomaceous earth (DE) mass/sample mass ratio were simultaneously studied by applying an experimental design approach (Plackett-Burman design (PBD) and central composite design (CCD)). Results showed that the extraction temperature was statistically significant (confidence interval of 95%) for most of the elements (high metal releasing was achieved at high temperatures). In addition, formic acid concentration was also statistically significant (confidence interval of 95%) for metals such as Cd and Cu. Most of the metals can be extracted using the same PLE operating conditions (formic acid concentration of 1.0 M, extraction temperature at 125 °C, static time of 5 min, one extraction step, extraction pressure at 500 psi and DE mass/sample mass ratio of 2). Taking in mind PLE requirements at the optimised operating conditions (125 °C), a time of 6 min is needed to pre-heat the cell. Therefore, the PLE assisted multi-element leaching is completed after 12 min. Analytical performances, such as limits of detection and quantification, repeatability of the over-all procedure and accuracy, by analysing GBW-08571, DORM-2, DOLT-3 and TORT-2 certified reference materials, were finally assessed.  相似文献   

7.
In this study the extraction efficiency of pressurized liquid extraction (PLE), employing different extraction solvent mixtures under different extraction conditions, was compared with extraction efficiencies of commonly used procedures, Soxhlet extraction and extraction enhanced by sonication. Spruce needles and fish tissue were selected as test samples. Purification of obtained extracts was carried out by gel permeation chromatography (GPC) employing gel Bio-Beads S-X3. Identification and quantitation of target PAHs was performed by high-performance liquid chromatography with fluorescence detection (HPLC–FLD).

Within optimisation of PLE conditions, temperature of extraction, type of solvent, duration and number of static cycles as well as the influence of sample pre-treatment (drying, homogenisation, etc.) were tested. Comparison of the extraction efficiency of PLE with the efficiencies of the other techniques was done under the optimised conditions, i.e. sample slurry obtained by desiccation with anhydrous sodium sulphate, extracted at 100 °C in 1 cycle lasting 5 min. Hexane:acetone (1:1, v/v) was chosen as the most suitable extraction solvent for isolation of analytes from test samples.

Comparison of mentioned isolation techniques with respect to the amount of co-extracts, procedure blank levels and time and solvent volume demands was also done.  相似文献   


8.
Microwave-assisted extraction using 1 M KOH/methanol (alkaline-MAE) in combination with solid-phase extraction treatment was developed and applied to polycyclic aromatic hydrocarbons (PAHs) in a sediment sample. Although various conditions were examined (100 or 150 °C for 10 or 30 min), comparable concentrations of PAHs to those obtained by conventional extraction with 1 M KOH/methanol at 70 °C for 4 h were obtained, even at 100 °C for 10 min. The concentrations obtained by using MeOH at 150 °C for 30 min without KOH were lower (by 1.3-37%) than those obtained by alkaline-MAE at 150 °C for 30 min. Since the developed technique can introduce higher concentration of benzo[ghi]perylene relative to those using pressurized liquid extraction (toluene, 150 °C, 15 MPa, 10 min, two cycles), the developed alkaline-MAE is a effective technique.  相似文献   

9.
A method for the determination of 11 UV-filter compounds in sludge has been developed and evaluated. The procedure includes the use of non-porous polymeric membranes in combination with pressurised liquid extraction (PLE). Firstly, the solid sample, wetted with the extraction solvent, was enclosed into tailor-made bags prepared with low density polyethylene. Secondly, these packages were submitted to a conventional PLE (70 °C, 4 cycles of 5 min static time). Finally, the analytes were determined by liquid chromatography–atmospheric pressure photoionisation–tandem mass spectrometry. The main advantage of this procedure is the reduction of time, solvent and labour effort ought to the combination of extraction and clean-up in a single step. Although the extraction is not quantitative (thus, standard addition is recommended for quantification) selectivity is clearly gained using the membrane as a consequence of the differences of permeation and transport through the membrane between the analytes and other sample matrix components. The optimised protocol provides limits of detection ranging from 0.3 ng g−1 (ethylhexyl dimethyl p-aminobenzoate (OD-PABA)) to 25 ng g−1 (ethylhexyl triazone (EHT)) with only 0.5 g of sludge sample. All the studied UV filters were found in the samples at concentration levels between 1.4 and 2479 ng g−1, emphasising the high adsorption potential of this kind of environmental pollutants onto solid samples such as sludge. Also, this method has permitted the determination of seven of the studied UV filters in sludge samples for the first time.  相似文献   

10.
The study proposes an analytical method to quantify 10 alkylphenols and 12 pesticides at ultra-trace levels by liquid chromatography in reverse mode coupled to positive electrospray ionisation–tandem mass spectrometry. The extraction procedure from environmental solids was optimised by pressurised liquid extraction using acetonitrile:isopropanol (1:1, v/v). The influence of several extraction experimental factors, temperature, pressure, duration and number of cycles, related to the PLE was investigated by an original and efficient chemometric approach. The optimised extraction method (80 °C, 40 bar, 10 min, 1 cycle) exhibited recoveries between 67 and 127% with RSD mostly under 13%. The whole method was applied to real samples: sludge, suspended materials, atmospheric fallouts and roof deposit. Pollutant levels were between 1 μg kg−1 and 5.9 mg kg−1.  相似文献   

11.
P. Canosa  J.P. Lamas  I. Orriols 《Talanta》2009,79(3):598-24
A novel method for the determination of the miticide bis[tris(2-methyl-2-phenylpropyl)tin] oxide, also known as fenbutatin oxide (FBTO), in agricultural soils is presented. Pressurized liquid extraction (PLE) followed by analyte derivatization and extraction into isooctane was the used sample preparation approach. Selective determination was achieved by gas chromatography with atomic emission detection (GC-AED). Influence of different parameters on the performance of the extraction process is thoroughly discussed; moreover, some relevant aspects related to derivatization, determination and quantification steps are also presented. As regards PLE, the type of solvent and the temperature were the most relevant variables. Under optimized conditions, acetone, without any acidic modifier, was employed as extractant at 80 °C. Cells were pressurized at 1500 psi, and 2 static cycles of 1 min each were applied. Acetone extracts (ca. 25 mL) were concentrated to 1 mL, derivatized with sodium tetraethyl borate (NaBEt4) and the FBTO derivative, resulting from cleavage of the Sn-O-Sn bond followed by ethylation of the hydroxyl fragments, extracted into isooctane and determined by GC-AED. Under final working conditions, the proposed method provided recoveries from 76 to 99% for spiked soil samples, a limit of quantification of 2 ng g−1 and an acceptable precision. Analysis of samples from vineyards sprayed with FBTO, confirmed the persistence of the miticide in soil for more than 1 year after being applied.  相似文献   

12.
Beauvericin (BEA), a supercritical fluid extraction with supercritical carbon dioxide from maize was investigated. Extraction efficiencies under several different extraction conditions were examined. Pressure, temperature, extraction time, organic modifier and water matrix content (10%) were investigated. The best extraction conditions were at a temperature of 60 °C, 3200 psi, for 30 min static extraction time and methanol as modifier solvent. Extraction recovery of 36% without modifier by adding water to the matrix in the extraction vessel (reproducibility relative standard deviations (R.S.D.)=3-5%) were recorded. Extraction recovery of 76.9% with methanol as co-solvent (reproducibility R.S.D.=3-5%) was obtained. Data shows that SFE gives a lower BEA recovery compared to conventional extraction protocol with organic solvents while SFE with modifier and conventional extraction yields are comparable. BEA extract contents were determined by high pressure liquid chromatography (HPLC) with a diode array detector (DAD) at 205 nm and BEA peak confirmed by LC-MS. Acetonitrile-water as mobile phase and column C-18 were both tested. Instrumental and analytical parameters were optimized in the range linear interval from 1 to 500 mg kg−1 and reached a detection limit of 2 ng.  相似文献   

13.
A novel and sensitive method for the determination of five benzotriazole compounds (commonly used as light stabilizers) in indoor dust is presented. Pressurized liquid extraction (PLE) and gas chromatography followed by tandem in time mass spectrometry (GC–MS/MS) were used as sample preparation and determination techniques, respectively. Extraction and clean-up were integrated on-line and, after an evaporative concentration step, the extract provided by the PLE instrument was injected directly in the GC–MS/MS system. Parameters affecting the performance of the sample preparation process were evaluated using experimental factorial designs. Under optimized conditions, analytes were recovered from 0.5 g samples in 3 static extraction cycles of 10 min, using a hexane:dichloromethane (7:3) mixture, at 90 °C. Silica (1 g) was placed in the bottom of the extraction cells as clean-up sorbent. The recoveries of the method varied from 82 to 122%, with standard deviations below 13. The inter-day precision ranged from 9 to 12%, and the limits of quantification (LOQs) remained below 10 ng g−1 for all species. For the first time, four of the five investigated species were found in dust from indoor environments. Their mean concentrations ranged from 71 to 780 ng g−1.  相似文献   

14.
A rapid analytical method including pressurized liquid extraction (PLE) and liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) has been developed for the determination of tocopherols and tocotrienols in cereals. The pressurized liquid extraction parameters were optimized in order to maximize the extraction efficiency. The use of methanol as extraction solvent at a temperature of 50 °C and a pressure of 110 bar, using one cycle of extraction with a static time of 5 min, provided the best results. A good LC separation was achieved using a C18 column and a solution of 6.0 mM ammonia in methanol/water (97:3, v/v) as the mobile phase at a flow rate of 0.2 mL min−1. MS coupling with an ESI interface in the negative ion mode was used as the detection technique. In the present work, it is shown that the addition of a base to the mobile phase is required to enhance the ionization of tocopherols and tocotrienols in negative ion mode electrospray ionization. The applicability of the method to cereal samples was confirmed. The reproducibility of the procedure was good, with relative standard deviations in the 6-10% range. The recoveries of added tocopherols from cereal samples ranged from 91 to 109%.  相似文献   

15.
Sun C  Liu H 《Analytica chimica acta》2008,612(2):160-164
The feasibility of employing non-ionic surfactant oligoethylene glycol monoalkyl ether (Genapol X-080) as an alternative and effective solvent for the microwave-assisted extraction of alkaloids from Rhizoma Coptidis was demonstrated. When compared with commonly used solvents, 5% Genapol X-080 enhanced the extraction efficiency. Under optimal conditions, i.e. 5% acidified Genapol X-080 (v/v), microwave-assisted extraction for 10 min at 100 °C, the extraction recovery of alkaloids reached 92.8% in a one-step extraction. The efficiency of cloud-point preconcentration of three alkaloids was in the range 93.6-94.7% with relative standard deviation lower than 3.3% by the proposed procedure. Furthermore, the combination of microwave-assisted extraction and cloud-point extraction was shown to be a green, rapid and effective approach for alkaloids preconcentration of Rhizoma Coptidis samples.  相似文献   

16.
A pressurized liquid extraction (PLE) method has been optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples and it was compared with ultrasonic extraction. The extraction step was followed by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS/MS) analysis. Parameters such as type of solvent, extraction time, extraction temperature and number of extractions were optimized. There were no significant differences among the two extraction methods although better extraction efficiencies were obtained when PLE was used, minimizing extraction time and solvent consumption. PLE procedure was validated, obtaining limits of detection (LODs) ranging from 0.02 to 0.75 μg kg−1 and limits of quantification (LOQs) ranging from 0.07 to 2.50 μg kg−1 for the selected PAHs. Recoveries were in the range of 59-110%, except for naphthalene, which was the most volatile PAH. Finally, the method was applied to real soil samples from Southeast of Spain. PAHs concentrations were low, and phenanthrene, pyrene, fluorene, benzo[a]pyrene and chrysene were the most frequently detected analytes in the samples.  相似文献   

17.
Chen J  Li W  Yang B  Guo X  Lee FS  Wang X 《Analytica chimica acta》2007,596(2):273-280
A new method based on accelerated solvent extraction (ASE) followed by a reliable high-performance liquid chromatography-diode array detector (HPLC-DAD) and positive ion electrospray-time of flight mass spectrometry (ESI-TOF/MS) analysis has been developed for the characterization and quantification of four major saponins in extracts of the seeds of Aesculus chinensis Bunge (Semen Aesculi). The saponins escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted from seeds of A. chinesis Bunge via ASE, and the operational parameters of ASE were optimized, such as extraction solvent, extraction temperature, static extraction time and extraction cycles. The optimized procedure employed 70% MeOH as extraction solvent, 120 °C of extraction temperature, 7 min of static extraction time, 60% flush volume and the extraction recoveries of the four compounds were nearly to 100% for two cycles. The HPLC conditions are as follows: SinoChrom ODS BP C18 (4.6 mm × 200 mm, 5 μm) column, acetonitrile and 0.10% phosphoric acid solution as mobile phase, flow rate is 1.0 mL min−1, detection length of UV is 203 nm, injection volume is 10 μL. The results indicated that the developed HPLC method is simple, sensitive and reliable for the determination of four major saponins in seeds of A. chinesis Bunge with a good linearity (r2 > 0.9994), precision (relative standard deviation (R.S.D.) <1.5%) and the recovery ranges of 95.2-97.3%. The limits of detection (LOD) of the four compounds were in the range of 0.40-0.75 μg mL−1. This assay can be readily utilized as a quality control method for Semen Aesculi and other related medicinal plants.  相似文献   

18.
The objective of this work is to investigate the influence of process parameters on the pressurized liquid extraction (PLE) of Ilex paraguariensis leaves. A factorial 26−2 experimental design was employed using responses as the extraction yield and the chromatographic profile of the extracts. The extraction time, polarity of solvent, amount of sample, numbers of PLE cycles, flushing volume and extraction temperature were selected as independent variables (factors). Results obtained indicated that the solvent polarity was the most significant variable in the study, while the amount of sample and extraction temperature also showed significant effect. The other variables did not present significant influence in the yield of extraction. GC/MS analysis of the extract enabled the identification of saturated hydrocarbons, fatty acids, fatty acid methyl esters, phytosterols and theobromine in the extracts. Quantitative analysis of four compounds presented in the extracts (caffeine, phytol, vitamin E and squalene) was performed by the GC/MS in the SIM mode.  相似文献   

19.
A pressurised liquid extraction (PLE) procedure, by using methanol/water mixture, was developed for extracting arsenical species from marine biological material (mussel and fish) and standard reference materials (CRMs). A Plackett-Burman 28 × 3/64 designs (PBD) was used as a multivariate strategy for the evaluation of the effects of several variables (MeOH/H2O solvent mixture, temperature, static time, extraction steps, pressure, mean particle size and diatomaceous earth (DE) mass/sample mass ratio) on the extracting procedure. Electrothermal atomic absorption spectrometry (ETAAS) was used to determine the total As concentration on the methanolic extracts. The accuracy of the optimised extraction procedure was verified by analysing several CRMs (GBW-08751, BCR-278R and DORM-2). The precision obtained (between 4.5 and 6.2%) was adequate. The extracted arsenic species (mainly arsenobetaine (AsB)) were analysed by high performance liquid chromatography coupled to ultraviolet cracking and hydride generation-atomic fluorescence spectrometry (HPLC-UV-HG-AFS). The analytical performances obtained were adequate for the arsenic speciation in marine biological samples; LOD between 10 and 35 ng g−1. The accuracy was verified for AsB using DORM-2. Finally, the proposed method (PLE followed by HPLC-UV-HG-AFS) was applied to mussel and fish samples.  相似文献   

20.
Quantification of polycyclic aromatic hydrocarbons (PAHs) in smoked fish products often requires multiple clean-up steps to remove fat and other compounds that may interfere with the chemical analysis. We present a novel pressurized liquid extraction (PLE) method that integrates exhaustive extraction with fat retention in one single analytical step. The PLE parameters: type of fat retainer, flush volume, solvent composition, fat-to-fat retainer ratio (FFR), and the dimensions of the extraction cells were the most important factors for obtaining fat-free extracts with high recoveries of PAHs. A 100 mL extraction cell filled with 18 g activated silica gel, dichloromethane:hexane (15:85, v/v) as extraction solvent, FFR of 0.025 and 100% flush volume was the best analytical setup for integrated extraction and fat retention.The one-step procedure provided a more rapid and cost-efficient alternative with minimization of waste generation compared to the standard reference method that is based on a multi-step procedure. Furthermore, the analytical quality of the two methods are comparable, while the new integrated approach for extraction and cleanup is less prone to analytical errors (random and systematic) because of fewer analytical steps.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号