首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Improving techniques for portable trace analyte collection and pretreatment is of critical concern for security, medical, food and environmental applications. The trend has been to employ MEMS technologies to meet this need as these microfabricated devices offer advantages such as small dead volumes, low power consumption, capacity for large scale manufacture and a commensurate savings with economies of scale. In this work a prototype trace sampling system intended for use with ion mobility spectrometers is presented. The system utilizes a stack of microfabricated preconcentrator plates capable of collecting samples in a sorbent polymer at flow rates up to 30 LPM. The plates are thermally desorbed after an integration period to produce a concentrated vapor plug that is transferred to the detector for analysis. A real-time controller, FPGA and custom electronics are used to manage independent heating of up to 4 of these devices in either constant voltage or temperature modes. The preconcentrators were tested with a commercial Vapor Tracer II IMS against TNT and RDX vapors ranging in concentration from 2.6 PPT to 620 PPT under a variety of conditions. Results are presented on performance of single preconcentrators with RDX, multiple cascaded devices vs. TNT and RDX, with and without a PDMS detector inlet membrane, and to compare sorbent coated and bare devices. The system demonstrated preconcentration factors of 38 with 2.6 PPT RDX and 30 with 13 PPT TNT.  相似文献   

2.
Lee JH  Song YA  Han J 《Lab on a chip》2008,8(4):596-601
In this paper, we report a new method of fabricating a high-throughput protein preconcentrator in poly(dimethylsiloxane) (PDMS) microfluidic chip format. We print a submicron thick ion-selective membrane on the glass substrate by using standard patterning techniques. By simply plasma-bonding a PDMS microfluidic device on top of the printed glass substrate, we can integrate the ion-selective membrane into the device and rapidly prototype a PDMS preconcentrator without complicated microfabrication and cumbersome integration processes. The PDMS preconcentrator shows a concentration factor as high as approximately 10(4) in 5 min. This printing method even allows fabricating a parallel array of preconcentrators to increase the concentrated sample volume, which can facilitate an integration of our microfluidic preconcentrator chip as a signal enhancing tool to various detectors such as a mass spectrometer.  相似文献   

3.
This paper presents the optimization of a micro gas preconcentrator based on a micro-channel in porous and non-porous silicon filled with an adequate adsorbent. This micro gas preconcentrator is both applicable in the fields of atmospheric pollution monitoring (Volatil organic compounds—VOCs) and explosives detection (nitroaromatic compounds). Different designs of micro-devices and adsorbent materials have been investigated since these two parameters are of importance in the performances of the micro-device. The optimization of the device and its operation were driven by its future application in outdoor environments. Parameters such as the preconcentration factor, cycle time and the influence of the humidity were considered along the optimization process. As a result of this study, a preconcentrator with a total cycle time of 10 min and the use of single wall carbon nanotubes (SWCNTs) as adsorbent exhibits a good preconcentration factor for VOCs with a limited influence of the humidity. The benefits of using porous silicon to modify the gas desorption kinetics are also investigated.  相似文献   

4.
Sukaew T  Chang H  Serrano G  Zellers ET 《The Analyst》2011,136(8):1664-1674
This article describes the development and characterization of a multi-stage preconcentrator/focuser (PCF) module designed to be integrated with a microfabricated gas chromatograph (μGC) for autonomous, in situ determinations of volatile organic compounds. The PCF module has been optimized specifically for the determination of trichloroethylene (TCE) vapors at low- or sub-parts-per-billion concentrations in the presence of common indoor air co-contaminants in residences at risk of vapor intrusion (VI) from surrounding TCE-contaminated soil. It consists of three adsorbent-packed devices arranged in series: a pre-trap of conventional (tubular metal) design for capturing interferences with vapor pressures <3 torr; a high-volume sampler, also of conventional design, for capturing (and transferring) TCE and other compounds with vapor pressures within the range of ~3 to 95 torr; and a microfocuser (μF) consisting of a micromachined Si chamber with an integrated microheater for focusing and injecting samples into the separation module. The adsorbent masses, sampling and desorption flow rates, and heating profiles required for selective, quantitative capture and transfer/injection of TCE are determined for each of the devices, and the assembled PCF module is used to analyze a test atmosphere containing 200 parts-per-trillion of TCE and 27 relevant co-contaminants with a conventional downstream capillary column and electron-capture detector. An average TCE transfer efficiency of 107% is achieved for a 20 L air sample, with a preconcentration factor of ~800,000.  相似文献   

5.
A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.  相似文献   

6.
Ma H  Zhang H  Tian Y  Wang L  Chen J 《色谱》2011,29(9):912-917
以饮用水中痕量挥发性有机物(VOCs)非目标筛查为目的,构建了一种新型的大体积水样高倍富集装置。对其精馏管长度、回收冷凝液体积、吸收介质等影响富集效果的关键因素进行了优化。该装置以水蒸气为吹扫气,同时以水作为吸收剂,将1 L水样富集浓缩至5 mL后,可使原有吹扫捕集-气相色谱-质谱法(P&;T-GC-MS)分析VOCs的灵敏度提高1~2个数量级。用该方法对某净水厂的源水与出厂水进行了痕量VOCs的定性分析与比较。与传统P&;T-GC-MS方法相比,本方法对两种水样的污染物检出数目由原来的无检出和5种分别提高至16种和35种。分析结果表明饮用水消毒前后污染物的种类及含量存在显著差异。  相似文献   

7.
This paper describes the development and calibration of a portable air sampler for detecting chemical vapors. The air sampler is equipped with a preconcentrator, a battery operated mini-pump, a three-way valve, capacitive sensors housed in a sensing chamber, and a data acquisition and control circuit board. The preconcentrator is used to adsorb trace level chemicals and to thermally desorb them into the sensing chamber. The air sampler was calibrated using known concentrations of ethylbenzene vapor generated by an Environics gas mixing system. The air sampler was also tested using low concentration toluene and ethanol vapors generated by diffusion based vapor generation device. The concentration factor of the preconcentrator was experimentally determined.  相似文献   

8.
Multidimensional gas chromatography (2D GC) is demonstrated as a way to improve limits of detectability of spectrophotometric detectors. UV and IR detectors are generally less sensitive than mass spectrometers or other GC detectors. This has placed some limitations on the useful capabilities provided by spectrophotometric detectors, such as the ability to provide structure‐related information for a particular analyte. In this paper, we report results from interfacing a 2D GC instrument to a UV detector. Symmetry factor and the ratio of retention time divided by peak width did not show deterioration of the quality of chromatography when a megabore column was used with this detector. Furthermore, an increase in the limits of detectability over that attainable in a single‐column system was realized by using the 2D GC system. However, the low flow (1 mL/min) imposed by the use of a microbore column (250 μm ID) caused significant tailing when the UV detector was used.  相似文献   

9.
Hobson ST  Cemalovic S  Patel SV 《The Analyst》2012,137(5):1284-1289
Remote and automated detection of organic compounds in subsurface aquifers is crucial to superfund monitoring and environmental remediation. Current monitoring techniques use expensive laboratory instruments and trained personnel. The use of a filled tubular preconcentrator combined with a chemicapacitive detector array presents an attractive option for the unattended monitoring of these compounds. Five preconcentrator materials were exposed to common target compounds of subsurface remediation projects (1,1,2-trichloroethane, trichloroethylene, t-1,2-dichloroethylene, benzene, and perchloroethylene). Rapid heating of the tube caused the collected, concentrated effluent to pass over the surface of a chemicapacitive detector array coated with four different sorbent polymers. A system containing a porous ladder polymer and the sensor array was subsequently used to sample the analytes injected onto sand in a laboratory test, simulating a subsurface environment. With extended collection times, effective detection limits of 5 ± 3 ppbV for 1,1,2-trichloroethane and 145 ± 60 ppbV for benzene were achieved. Effects of the preconcentrator material structure, the collection time, and sensor material on the system performance were observed. The resultant system presents a solution for remote, periodic monitoring of chlorinated organic compounds and other volatile organic compounds in a soil matrix.  相似文献   

10.
This paper explores the response of a novel fiber optics sensor allowing real-time determination of the migration rate of vapor zones in capillary gas chromatography. The sensitivity is related to the gradient of the vapor zone distribution in the capillary and it is highest when vapor zones show steep variations in concentration. The expected linearity between the height of the velocity peaks and the response of a thermal conductivity detector is demonstrated experimentally. The sensor can be used to infer an approximate value of the analyte diffusion coefficient from the time response. Finally, the time evolution of the envelope of the optical signal is explained with experimental evidences.  相似文献   

11.
We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95 × 95 mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4 m long, 320 μm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10–200 °C was achieved with peak power demand of approximately 25 W. The 7.5 m capillary column was static coated with a 2 μm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100 mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics.  相似文献   

12.
Park J  Zellers ET 《The Analyst》2000,125(10):1775-1782
Accounting for changes in temperature and ambient humidity is critical to the development of practical field vapor-monitoring instrumentation employing microfabricated sensor arrays. In this study, responses to six organic vapors were collected from two prototype field instruments over a range of ambient temperatures and relative humidities (RH). Each instrument contains an array of three unthermostated polymer-coated surface acoustic wave (SAW) resonators, a thermally desorbed adsorbent preconcentrator bed, a reversible pump and a small scrubber cartridge. Negligible changes in the vapor sensitivities with atmospheric RH were observed owing, in large part, to the temporal separation of co-adsorbed water from the organic vapor analytes upon thermal desorption of preconcentrated air samples. As a result, calibrations performed at one RH level could be used to determine vapors at any other RH without corrections using standard pattern recognition methods. Negative exponential temperature dependences that agreed reasonably well with those predicted from theory were observed for many of the vapor-sensor combinations. It was possible to select a subset of sensors with structurally diverse polymer coatings whose sensitivities to all six test vapors and selected binary vapor mixtures had similar temperature dependences. Thus, vapor recognition could be rendered independent of temperature and vapor quantification could be corrected for temperature with sufficient accuracy for most applications. The results indicate that active temperature control is not necessary and that temperature and RH compensation is achievable with a relatively simple microsensor system.  相似文献   

13.
The performance characteristics of a portable GC instrument requiring no compressed gas supplies and using relatively lightweight transportable components for the analysis of volatile organic components in large-volume air samples are described. To avoid the need for compressed gas tanks, ambient air is used as the carrier gas, and a vacuum pump is used to pull the carrier gas and injected samples through the wall-coated capillary column and a photoionization detector (PID). At-column heating is used eliminating the need for a conventional oven. The fused silica column is wrapped with heater wire and sensor wire so that heating is provided directly at the column. A PID is used since it requires no external gas supplies and has high sensitivity for many compounds of interest in environmental air monitoring. In order to achieve detection limits in the ppb range, an online multibed preconcentrator containing beds of graphitized carbons and carbon molecular sieves is used. After sample collection, the flow direction through the preconcentrator is reversed, and the sample is thermally desorbed directly into the column. Decomposition of sensitive compounds during desorption is greater with air as the carrier gas than with hydrogen.  相似文献   

14.
Use of electron-beam induced crosslinking to pattern films of monolayer-protected gold nanoparticles (MPNs) onto a chemiresistor (CR) sensor array is described. Each of the four CRs comprises a 100 μm(2) set of interdigital electrodes (IDEs) with 100 nm widths and spaces, separated from adjacent devices by 4 μm. Films of four MPNs, each with a different thiolate monolayer, were successively patterned on the IDEs. Vapor exposures yield rapid, reversible changes in CR resistances and differential vapor sensitivities comparable to those reported for larger CRs with unpatterned MPN films. The array response patterns facilitate vapor discrimination. This is the smallest MPN-coated CR array yet reported. The advantages of using such an array as the detector in microfabricated gas chromatographic analyzers are considered.  相似文献   

15.
The gas sensing behaviors of cobalt phthalocyanine (CoPc) and metal-free phthalocyanine (H2Pc) thin films were investigated with respect to analyte basicity. Chemiresistive sensors were fabricated by deposition of 50 nm thick films on interdigitated gold electrodes via organic molecular beam epitaxy (OMBE). Time-dependent current responses of the films were measured at constant voltage during exposure to analyte vapor doses. The analytes spanned a range of electron donor and hydrogen-bonding strengths. It was found that, when the analyte exceeded a critical base strength, the device responses for CoPc correlated with Lewis basicity, and device responses for H2Pc correlated with hydrogen-bond basicity. This suggests that the analyte-phthalocyanine interaction is dominated by binding to the central cavity of the phthalocyanine with analyte coordination strength governing CoPc sensor responses and analyte hydrogen-bonding ability governing H2Pc sensor responses. The interactions between the phthalocyanine films and analytes were found to follow first-order kinetics. The influence of O2 on the film response was found to significantly affect sensor response and recovery. The increase of resistance generally observed for analyte binding can be attributed to hole destruction in the semiconductor film by oxygen displacement, as well as hole trapping by electron donor ligands.  相似文献   

16.
Explosives in solution were determined as mixtures containing highly volatile improvised explosives such as peroxides and conventional military grade explosives such as PETN, RDX, and Tetryl using a high speed gas chromatograph with differential mobility detector in a single measurement. Instrument parameters were evaluated and adjusted to permit detection of nanogram amounts of explosives with this broad range of vapor pressures in times under 3 min for HMTD to TNT or under 16 min for HMTD to Tetryl. As in prior studies of response to explosives with mobility spectrometers, pre-separation of sample by gas chromatography improved response in the differential mobility detector; however, unlike prior configurations, the supporting gas atmosphere did not contain modifiers to adjust selectivity in mobility and selectivity was provided only by characteristic stability of product ions in negative and positive polarities. Field dependence of product ions in purified air was determined for each explosive and patterns were sufficiently distinct to suggest the addition of selectivity through the use of several differential mobility detectors operated in parallel or series with characteristic separation voltages.  相似文献   

17.
The ion mobility detector is a device that can be used for the selective, ultratrace detection of organic compounds after capillary gas chromatography. It is the only gas chromatographic detector which does not require heteroatomic compounds for selective response, yet concern is often expressed over its quantitative capabilities. Being a secondary ionization device, competitive charge transfer reactions from unseparated compounds or detector gas contamination may decrease the accuracy of measurement. This paper investigates the effects of both electronegative and electro-positive contaminants on the detector's response. In general, it was found that contamination of the detector did affect response but no more severely than in conventional detectors such as the electron-capture detector or the flame ionization detector.  相似文献   

18.
Atmospheric humidity causes the major problem using ion mobility spectrometers (IMS) under ambient conditions. Significant changes of the spectra are decreasing sensitivity as well as selectivity. Therefore, the influence of humidity on the IMS signal was investigated in case of direct introduction of the analyte into the ionisation chamber and in case of pre-separation by help of a multi-capillary column (MCC). For direct analyte introduction, a significant decrease of the total number of ions in the range of 28-42% with increasing relative humidity was found. Simultaneously additional peaks in the spectra were formed, thus complicating the identification of the analytes. In case of pre-separation of the analyte, the spectra do not change with increasing relative humidity, due to the successive appearance of the analyte and the water molecules in the ionisation chamber. Detection limits were found in the range of 5 μg/m3 (about 1 ppbv) for selected terpenes and—with pre-separation—independent on relative humidity of the analyte. Without pre-separation, detection limits are in the same range for dry air as carrier gas but in the range of 200-600 μg/m3 when relative humidity reaches 100%. Thus, MCC-UV ion mobility spectrometry is optimally capable for the detection of trace substances in ambient air (e.g. indoor air quality control, process control, odour detection) without further elaborate treatment of the carrier gas containing the analyte and independent on relative humidity.  相似文献   

19.
The effect of gas-phase proton transfer reactions on the mass spectral response of solvents and analytes with known gas-phase proton affinities was evaluated. Methanol, ethanol, propanol and water mixtures were employed to probe the effect of gas-phase proton transfer reactions on the abundance of protonated solvent ions. Ion-molecule reactions were carried out either in an atmospheric pressure electrospray ionization source or in the central quadrupole of a triple-quadrupole mass spectrometer. The introduction of solvent vapor with higher gas-phase proton affinity than the solvent being electrosprayed caused protons to transfer to the gas-phase solvent molecules. In mixed solvents, protonated solvent clusters of the solvent with higher gas-phase proton affinity dominated the resulting mass spectra. The effect of solvent gas-phase proton affinity on analyte response was also investigated, and the analyte response was suppressed or eliminated in solvents with gas-phase proton affinities higher than that of the analyte.  相似文献   

20.
This article reports on an integrated explosive-preconcentration/electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor. The challenges involved in such system integration are discussed. A hydrogel-coated screen-printed electrode is used for the detection of the thermally desorbed TNT from a preconcentration device using rapid square wave voltammetry. Optimization of the preconcentration system for desorption of TNT and subsequent electrochemical detection was conducted yielding a desorption temperature of 120 °C under a flow rate of 500 mL min−1. Such conditions resulted in a characteristic electrochemical signal for TNT representing the multi-step reduction process. Quantitative measurements produced a linear signal dependence on TNT quantity exposed to the preconcentrator from 0.25 to 10 μg. Finally, the integrated device was successfully demonstrated using a sample of solid TNT located upstream of the preconcentrator.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号